Loading...
HomeMy WebLinkAbout32 - C - Code Mod Request Email from Bob Mahn to Abdoul 21 Oct 2014From:Abdoul Gafour To:J. D. Wilson Subject:FW: RE: Pre-App for Highlands 435 Zone Reservoir Replacement Date:Tuesday, February 17, 2015 10:29:19 AM Attachments:City of Renton PW Transportation.pdf     From: Bob Mahn Sent: Tuesday, October 21, 2014 2:44 PMTo: Vicki GroverCc: Jim Seitz; Abdoul GafourSubject: RE: RE: Pre-App for Highlands 435 Zone Reservoir Replacement   I have discussed the NE 12th Street frontage improvements design concept today with Jim. Jim is  now planning on bike lanes on NE 12th rather than bikes sharing the roadway with other vehicular  traffic.  With that in mind, the roadway width between centerline of ROW to face of new curb on  the north side of the street should be a minimum of 16 feet to provide a 11-foot traffic lane, a 5- foot bike lane  and no parking.  No parking will allow the existing power poles to remain in their  existing location and be within the new planting strip. Therefore, we support the attached frontage  improvements design concept. The 18-foot dimension for location of the new curb may be  appropriate to assure that the power poles are in the planter strip with sufficient clearance from the  roadway.  Final determination of 16 versus 18 feet can be made once surveyed plans are available.   Bob Mahn Transportation Planning X-7322   From: Vicki Grover Sent: Tuesday, October 21, 2014 11:41 AMTo: Bob MahnSubject: FW: RE: Pre-App for Highlands 435 Zone Reservoir Replacement   Hi Bob, I found this email to you regarding the Reservoir project.  It does look like it fell through the cracks  but we are on it now!!   Vicki Grover, P.E. Civil Engineer II   Plan Review Section City of Renton 1055 - S. Grady Way    6th floor Renton, WA  98057 Phone: (425) 430-7291 E-mail: vgrover@rentonwa.gov   From: Vicki Grover Sent: Tuesday, September 23, 2014 12:52 PMTo: Bob MahnSubject: RE: Pre-App for Highlands 435 Zone Reservoir Replacement   Hi Bob, This is a COR project, and the address is 3410 NE 12th Street.  They will phase the project and the  end result will be all new reservoirs, booster pump station and new storm detention. My question to is do we need to do street frontage improvements on N. 12th Street?  According to  COR maps, N. 12th Street is a minor arterial. Thanks and let me know if you have questions.  Pre-app is this Thursday……   Vicki Grover, P.E. Civil Engineer II   Plan Review Section City of Renton 1055 - S. Grady Way    6th floor Renton, WA  98057 Phone: (425) 430-7291 E-mail: vgrover@rentonwa.gov