HomeMy WebLinkAbout1545 - Avana Ridge - BP - 2012 Energy Code WorksheetInstructions for Electronic Forms, pg 1 Revised Jan 2014 Commercial Provision Chapters 1 - 5 of the 2012 Washington State Energy Code apply to all commercial occupancies, R-2 and R-3 occupancies greater than 3 stories above grade, and R-1 occupancy (all building heights). Intro This file, LTG12-v3.XLSM, has electronic compliance forms for electrical power and lighting system provisions as defined Section C405. This includes interior and exterior lighting systems, electric motors, and transformers. There are two companion files: ENV12-v3.XLSM (Sections C101, C303, C402 and Appendix A envelope requirements) and MECH12-v3.XLSM (Section C403 mechanical systems requirements). This form is a compliance aid and is not a substitute for the full energy code text or specific jurisdiction compliance requirements. Users should refer to the code text and contact the local jurisdiction for complete information. The full 2012 WSEC code text is available for download from the NEEC website: http:/www.neec.net/energy-codes Training Refer to the NEEC website for instruction on how to complete all of the 2012 WSEC Compliance Forms. Start-up Select this file from the NEEC website to download to your computer. When opening the file be sure to Enable Macros. This file is an Excel workbook that contains multiple compliance forms and resources in Excel worksheets. Each worksheet is indicated by a tab at the bottom of the screen. You may visit each worksheet by selecting it's tab. Most calculations are automated. Cells that display informational text and the results of calculations are write-protected and cannot be edited. Save Files This file is saved in the same manner as any standard Excel file. Getting Around Some forms have two pages. Both pages are available on screen when you select the tab for a form (worksheet). Use the scroll bars to find the second page located below the first page. All general project information and the date are entered once on LTG-SUM. This information is automatically replicated on all other LTG forms. The LTG-SUM form accompanies all other LTG forms except LTG-EXT, which is a stand alone form. Only input cells are accessible. If you try to edit a write-protected cell an error message will appear requesting a password. A password IS NOT required to complete these forms. You may use the TAB key to move to the next input cell. If the TAB doesn't take you where you want to go, use your mouse to move around the form. Avoid excessively long text strings when entering information. In some cases, text that extends beyond the available space will not be visible. In most cases the text will wrap within the cell. This may force part of the form onto a new page. To enter the date, use this format: mm/dd/yyyy. For example, you would enter 7/1/2013 or 12/21/2014. Check boxes can be checked or unchecked by clicking in the box with your mouse. Radio buttons (circles) allow only one in a set to be selected. Drop-down lists have an arrow at the right side of the cell. Click on the arrow with your mouse and select the appropriate option. Use the delete button on your computer to clear a drop-down ent When a form has a space for notes or explanation, click anywhere in the space to edit. Personalizing You can personalize the forms with your company name, address, phone, or any other information. This is done by editing the header or footer in Excel. Many tables, such as for listing proposed lighting fixture types, have a certain number of lines available for entering data. You may need more lines to enter all your information. Where this feature is available, you can add additional lines to the table by selecting the "+" button on the right hand side of the table with your mouse. To remove lines that you have added, select the "-" button with your mouse. This will delete the last line of the section. You cannot remove lines that were not added; an error message will appear if you try. If you add additional lines with this method, the pagination may be affected forcing the forms to carry additional lines over to other pages. Be sure to submit all pages to the plans examiner. Compliance Path You must select a Compliance Path on LTG-SUM (line 12). Interior LTG Power Allowance Method You must select a Lighting Power Allowance Method on LTG-SUM (line 14) to activate the required worksheets and automatically calculate interior lighting power allowances. Exterior LTG Zone You must select a Lighting Zone on LTG-EXT (line 12) to activate this worksheet to display the applicable base site allowance and automatically calculate the applicable exterior lighting power allowances. 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Energy Code Overview Input Cells Adding And Deleting Lines Instructions for Electronic Forms, pg 2 Revised Jan 2014 For projects complying via the Building Area Method, provide the total gross interior area for each Building Area Type in the Maximum Allowed Lighting Wattage table using the drop down menu. Assign a Building Area using the drop menu for each lighting fixture type defined in the Proposed Lighting Wattage table. The worksheet will total all fixtures assigned to each Building Area. Each Buidling Area shall comply independently. For projects complying via the Space-By-Space Method, provide total gross interior area for each Space Type in the Maximum Allowed Lighting Wattage table using the drop down menu. For Atriums, provide total gross interior area and ceiling height (above finished floor) in the Maximum Allowed Lighting Wattage table. All Retail Display lighting shall be entered in the LTG-INT-DISPLAY worksheet. Results from this worksheet automatically transfer to the LTG-INT-SPACE worksheet in the assigned locations under Maximum Allowed Lighting Wattage and Proposed Lighting Wattage tables. For projects with Retail Display lighting that is in addition to Retail Sales general area lighting, assign a Retail Display category (per Table C405.5.2(2) Footnote A) to each lighting fixture type defined in the Proposed Display Lighting Wattage table using the drop down menu. Provide the total gross interior area for each eligible Retail Display category in the Maximum Allowed Display Lighting Wattage table using the drop down menu. The total Retail Display gross interior area entered in the LTG-INT-DISPLAY worksheet may not exceed the total Retail Sales gross interior area entered in the LTG-INT-SPACE worksheet. Provide square-foot surface area, perimeter linear feet, or number of items for each Surface Type in the Tradable and Non- Tradable Maximum Allowed Lighting Wattage tables using the drop down menus. Assign a Surface using the drop menu for each exterior lighting fixture type defined in the Tradable and Non-Tradable Proposed Lighting Wattage tables. The forms should print on any printer supported by your operating system. You will need to have the following TrueType fonts installed under Windows: Arial, Times New Roman, Courier New and Wingdings. These are all standard Windows fonts. If you are losing form details when printing, you may have a shortage of printer memory. Try printing problem pages individually. By default, only the active worksheet is printed. To print more than one worksheet at a time, open your print set-up menu and select either the page range you wish to print or Entire Workbook. Forms (worksheets) in a workbook may not be deleted because the file is locked. To print blank forms to fill out by hand, delete all of the heading information at the beginning of LTG-SUM and select the desired Lighting Power Allowance Method. For each radio button group there is a button labeled "Clear." Clicking this button will clear the other buttons so that they will print as empty circles. The "Clear" button will not print. End of Instructions for Electronic Forms 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Exterior LTG Printing Blank Forms Interior LTG Retail Display Interior LTG Space-By- Space Method Interior LTG Building Area Method Interior Lighting Summary LTG-SUM 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Info Project Address 10616 SE 172nd Street, Renton, WA 98055 Date 12/29/2015 For Building Department Use Applicant Name:Avana Ridge, LLC Applicant Address:9675 SE 36th Street, Suite 105 Applicant Phone:Office: 206-588-1147 Project Description FALSE Interior Lighting System Description Briefly describe lighting system type and features. Additions and Change of Space Use (C101.4.3 & C101.4.4) Alterations, Renovations and Repairs (C101.4.3.1) Provide Building Area Method (LTG-INT-BLD) or Space-By-Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Provide Building Area Method (LTG-INT-BLD) or Space-By-Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofit and non-retrofit spaces shall be documented separately using multiple forms. Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. Provide a separate Space-By-Space Method (LTG-INT-SPACE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. Lighting Compliance Path Lighting Power Allowance Method Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 New Building Addition Alteration Building Area Method Space-By-Space Method Addition area or Change of Space Use area complies with all applicable provisions as stand alone project Addition area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions per C101.4.3 (If Total Building Performance then only LGT-CHK is Total Building PerformanceLighting Power Density Calculations new multifamily building - lighting at dwelling units and common areas 60% or more of luminaires in space replaced Less than 60% of luminaires in space replaced Lamp and/or ballast replacement within existing luminaires only – existing total interior building wattage not increased New wiring installed to serve added fixtures and/or fixtures relocated to new circuit New or moved lighting panel Space is reconfigured - luminaires unchanged or moved only No changes are being made to the interior lighting and space use not changed. Compliance forms do not require a password to use. Instructional and calculating cells are write- Selection required to enable LPA forms Plans Included Interior Lighting Summary - Space-By-Space LTG-INT-SPACE 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address 10616 SE 172nd Street, Renton, WA 98055 Date 12/29/2015 Lighting Alterations, Renovations & Building Additions For Building Department Use Total Building Performance - No lighting calcs required Location (plan #, room #) Space Type* Allowed Watts per ft2 Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) Retail Display Allowance from LTG-INT-DISPLAY Area Allowed Watts Total Total Building Performance - No lighting calcs required Location (plan #, room #) Fixture Description*** Number of Fixtures Watts/ Fixture Watts Proposed Retail Display Lighting from LTG-INT-DISPLAY Total Proposed Watts Interior Lighting Power Allowance *** Include existing to remain lighting fixtures and exempt lighting equipment per notes below. Notes: 1. Include ALL proposed lighting fixtures. 2. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 3. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. 4. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 5. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description. * Select Table C405.5.2(2) category from drop down menu. ** For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 W/ft. ht., above 40 feet is 0.02 W/ft. ht. Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Atrium** Enter Height:Existing Lighting Enter Exist. Watts: Addition combined Stand alone bldg. addition 60% or more fixtures Less than 60% fixtures replaced Notes: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. b. For retrofits and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall existing builidng, include all applicable existing Space Types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 60% of existing fixtures will be replaced, provide total existing lighting wattage (prior to retrofit) in the space provided in the Maximum Allowed Lighting table. Interior Display Lighting - Space-by-Space LTG-INT-DISPLAY 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Info Project Address 10616 SE 172nd Street, Renton, WA 98055 Date 12/29/2015 For Building Department Use Applicant Name:Avana Ridge, LLC Total Building Performance - No lighting calcs required Location (plan # room #) Allowed Watts per ft2 ** Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) Area Area Watts Total Display Lighting Base Allowance ++ Total Display Allowance Total Building Performance - No lighting calcs required Display Area* Location (plan # room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts Retail 1 Retail 2 Retail 3 Retail 4 Retail Display Area Type* Only separately controlled display fixtures independent of general area lighting per Table C405.5.2(2) footnote A may be entered here. Notes: 1. For proposed Display Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all display fixtures. * Only retail sales areas that meet the requirements defined in Table C405.5.2(2) footnote A may be entered here. Select retail sales areas form drop down menu. ** Wattages per Table C405.5.2(2) footnote A. ++ Display light allowance per footnote A calculation. * Select retail sales display area from drop down menu. Proposed Display Lighting Totals Interior Lighting Summary - Building Area Method LTG-INT-BLD 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address 10616 SE 172nd Street, Renton, WA 98055 Date 12/29/2015 For Building Department Use Total Building Performance - No lighting calcs required Building Area* Location (plan #, room #, or ALL)Area Description Allowed Watts per ft2 Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) Total Total Building Performance - No lighting calcs required Building Area* Location (plan #, room #) Fixture Description** Number of Fixtures Watts/ Fixture Watts Proposed Compliance by Building Area Building Area Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Total Lighting Alterations, Renovations & Building Additions Warnings * Select Table C405.5.2(1) Building Area from drop down menu. * Select Table C405.5.2(1) Building Area from drop down menu. ** Include existing to remain lightingand exempt lighting equipment per notes below. Addition combined Stand alone bldg. addition 60% or more fixtures Less than 60% fixtures replaced Notes: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. b. For retrofits and building additions, provide Building Area types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall existing builidng, include all applicable existing Building Area types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 60% of existing fixtures will be replaced, use LTG-INT-SPACE form. Notes: 1. Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between Building Area types is not allowed under the Building Area Method compliance path. 2. Proposed fixtures must be listed in the building area in which they occur. Include ALL proposed lighting fixtures. 3. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 4. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, Exterior Lighting Summary LTG-EXT 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Info 10616 SE 172nd Street, Renton, WA 98055 Date 12/29/2015 For Building Department Use Avana Ridge, LLC 9675 SE 36th Street, Suite 105 Office: 206-588-1147 Project Description Lighting Zone Compliance Option Building Grounds Applies to luminaires > 100 Watts Tradable Maximum Allowed Lighting Wattage Base Site Allowance:500 Tradable Surfaces Surface Description Allowed Watts per ft2 or per lf Area (ft2), perimeter (lf) or # of items Allowed Watts x ft2 (or x lf) Total Allowed Tradable Watts: Tradable Proposed Lighting Wattage (Use mfgr listed maximum input wattage for luminaire.) Tradable Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Tradable Watts: Non-Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: 500 Non-Tradable Surfaces Surface Description Allowed Watts per ft2 or per lf Area (ft2), perimeter (lf) or # of items Allowed Watts x ft2 (or x lf) Non-Tradable Proposed Lighting Wattage Non-Tradable Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total excess Non-Tradable watts:0 Site Allowance Balance:500 Exterior Lighting Exterior Lighting Alterations New Building Addition Alteration Zone 4 Efficacy > 60 lumens/W Exemption (list) No changes are being made to the existing exterior lighting Controlled by motion sensor Lighting Power Density Calculations Total Building Performance Zone 3Zone 2Zone 1 Non-tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non-tradable surfaces are less than the remaining site allowance. Total proposed tradable watts may not exceed the sum of total allowed tradable watts plus the base site allowance. Any base site allowance not needed to make tradable watts comply can be applied to individual non-tradable New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Plans Included Provide applicable exterior lighting controls per C405.2.4 and commissioning per As specified by jurisdiction. Zone selection required to enable LTG-EXT form Project Address: Applicant Name: Applicant Addr: Applicant Phone: Lighting, Motor, and Transformer Permit Documents Checklist LTG-CHK 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address 10616 SE 172nd Street, Renton, WA 98055 Date 12/29/2015 Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS (Section C405.2) Indicate on plans the manual control type & locations served;DEFERRED Indicate of plans the 50% lighting load reduction method provided or identify exception taken DEFERRED Indicate lighting system automatic shut-off capability - identify lighting zone areas served on plans;DEFERRED Indicate locations of override switches on plans and the areas served, include area sq. ft.;DEFERRED Indicate locations where automatic shutoff is provided by other methods (occupancy sensor, daylight controls, etc)DEFERRED C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors DEFERRED Indicate vertical fenestration primary and secondary daylight zone areas on plans, include sq. ft.;DEFERRED Indicate skylight daylight zone areas on plans, include sq. ft.DEFERRED Indicate on plans the locations served by daylight zone controls;DEFERRED Indicate in plans the lighting load reduction (dimming) method - stepped or continuous dimming DEFERRED Yes C405.2.3 Specific application lighting controls - General Indicate on plans the locations served by specific application lighting controls DEFERRED Indicate lighting control method for display and accent lighting, and display case lighting; Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space Provide a lighting control device at each guest room entry for all permanently installed fixtures in guest room; Indicated whether lighting control is manual or automatic No C405.2.3 - Item 4 Supplemental task lighting Provide automatic shut-off vacancy controls for supplemental task lighting, including under-shelf or under-cabinet lighting Identify eligible non-visual applications and method of lighting control; Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space Indicate lighting control method for lighting equipment for sale or demonstration; Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space If egress lighting power density is greater than 0.05W/ft2, indicate method of automatic shut-off during unoccupied periods; DEFERRED Identify on plans the egress fixtures that function as both normal and emergency means of egress illumination DEFERRED No C405.10 C405.11 Cooler and freezer lighting Provide vacancy device or timer to turn off fixtures within 15 minutes of unoccupancy for cooler and freezer lighting fixtures with lamp efficacy less than 40 lumens per watt DEFERRED Yes C405.2.4 Exterior lighting controls Indicate on exterior lighting plans the automatic lighting control method and locations served DEFERRED Yes C405.6.1 Exterior building grounds lighting controls Provide motion sensor controls for building grounds fixtures rated at greater than 100 watts with lamp efficacy less than 60 lumens, or identify exception taken DEFERRED Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception;DEFERRED Provide written procedures for functional testing of all automatic controls and describe the expected system response;DEFERRED Identify in construction documents the party responsible for functional testing of automatic lighting controls DEFERRED INTERIOR LIGHTING POWER & EFFICACY (Sections C405.5, C405.10, C405.11) Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture;DEFERRED No C405.2.3 - Item 6 Lighting equipment for sale or demonstration Yes C405.2.3 - Item 7 Means of egress lighting C40551 Yes C408.3 Lighting system functional testing No C405.2.3 - Item 3 Hotel/motel guest rooms No C405.2.3 - Item 5 Lighting for non- visual applications Yes C405.2.1.1 C405.2.1.2 Manual interior lighting controls Yes C405.2.2.1 Automatic time switch controls and override switching Yes C405.2.2.3 Daylight zones - Vertical fenestration and skylights Yes C405.2.2.3.2 Daylight zone controls No C405.2.3 - Items 1&2 Display and accent lighting The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Lighting, Motor, and Transformer Permit Documents Checklist LTG-CHK 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address 10616 SE 172nd Street, Renton, WA 98055 Date 12/29/2015 Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Identify spaces eligible for lighting power exemption on plans and in compliance forms;DEFERRED Identify lighting equipment eligible for exemption in fixture schedule and in compliance forms;DEFERRED Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently DEFERRED Yes C405.4 Exit signs Provide exit sign types and rated watts per fixture in fixture schedule (maximum 5 watts per fixture)DEFERRED No C405.10 C405.11 Cooler and freezer lighting For lighting in walk-in coolers and freezers, and refrigerated warehouse coolers and freezers, provide rated lamp efficacy (in lumens per watt) in fixture schedule DEFERRED Lighting Power Calculation - Indicate compliance path taken Yes C405.5.2 Building Area Method Complete required compliance forms – proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans DEFERRED No C405.5.2 Space-By-Space Method Complete required compliance forms – total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas as applicable EXTERIOR LIGHTING POWER & EFFICACY (Section C405.6) Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture;DEFERRED Identify exterior applications eligible for lighting power exemption on plans and in compliance forms;DEFERRED Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting DEFERRED Yes Table C405.6.2(1)Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ DEFERRED Yes C405.6.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts, provide rated lamp efficacy (in lumens per watt) in fixture schedule DEFERRED Yes C405.6.2 Exterior lighting power calculations Complete required compliance form – proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed DEFERRED MOTORS & TRANSFORMERS (Sections C405.8, C405.9) Yes C405.8 Electric Motors For motors not part of an HVAC system, provide electric motor schedule on electrical plans with hp, rpm, and rated efficiency DEFERRED Yes C405.9 Transformers Provide distribution transformer schedule on electrical plans with transformer size and efficiency DEFERRED If "no" is selected for any question, provide explanation: Yes No N.A. Yes C405.6.2 Total connected exterior lighting power Yes C405.5.1 C405.5.1.1 C405.5.1.2 C405.5.1.3 C405.5.1.4 Total connected interior lighting power