Loading...
HomeMy WebLinkAboutR-417859NW 1/4 OF THE NW 1/4 AND THE NE 1/4 OF THE NW 1/4 SECTION 9, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M. 00 r\ T Hit W I- Q LU J 0 in 375 370 k14111 360 355 00112 MIXED USE BUILDING A o . , O vIN + ON In ao MCI g R IV x N 2 W W � I't n 9+00 —SD SD _ yam[ S CF 2 a 0 x Q IN I 1 ON P _ D W L_ m� CB 136A o y os�y`RIM=365.35 TING CB ?� 8IE OUT=361.68 o ZEMAIN o0 y° 10+00 _ Pis o F 8" SO 0 10.00% was fs �O CB 136 ssy ICit� ,^,p P�yy 00 NE SUNSET BID EVARD (SR 900�s,° °� sins ;9 fy o ss� ✓ EXISTING CB TYPE 2-48" CB 6 TYPE —48" STA. 9+07.94, 24.03' LT STA. 9+54.24, 25.46' LT RIM=365.73 RIM=365.75 -.-- --. " 18" IE-IN=357.05 (NE). 18" IE IN=357.28.(NE)(EX) PROPOSED 18" IE OUT=357.00 (SW) 8" IE IN=359.53 (NW) CURB CURB 18" IE OUT-35Z28 (SW)(EX) EXISTING CURB CUT PROPOSED CURB '.. -. DRIVEWAY PROPOSED CURB TO REMAIN 6" WM XINGI EXISTING GRADE STAB 8+79.96� AT, ¢ OF ROAD EL=361.52 _. _. 46 LF 18" SD ®0.50% 6 ,....... 134 LF 18" SO -0 0.50% 88 LF 18" SO 01.02% LI Cq cq cq cq cq cq c M M M M M M M M M M M 8+40 8+80 9+20 9+60 10+00 Call 811 • two business days before you dig I) N0. 10+40 CNIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBM17AL CNIL CONSTRUCTION PERMIT RMUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL REVISION oz � y y 0 o p w- y SDI �o DI m ° 380 375 370 365 360 355 350 BY I DATE I APPR I 0 0 T 0 1 N a U KEY PLAN L* y NITS NOTES: LEGEND: o 1. ALL CATCH BASINS WITHIN THE RIGHT — — PROPERTY UNE/ROW UNE O OF WAY SHALL BE CONSTRUCTED WITH O VANED GRATE LOCKING UD, UNLESS ROW CENTERLINE O NOTED OTHERWISE. N ss ss ss- ASPHALT 0 ROADSIDE INFILTRATING BIORETENTION PLANTER PER CITY OF RENTON J so STANDARD DETAIL 262.00 ON SHEET o P CONCRETE C5.50 CONSTRUCTED 'NTH THROUGH —CURB INLET AT UPSTREAM SIDE OF PLANTER CONNECT OVERFLOW CURB VON TO CONVEYANCE IN ROW. CONTRACTOR s SHALL PROTECT BIORETENTION AREA —360— MAJOR FINISHED GRADE CONTOUR DURING CONSTRUCTION TO PREVENT COMPACTION OR SILTATION. 362 MINOR FINISHED GRADE CONTOUR M ICE) ON —SITE BIORETENTION PER CITY OF —�— STORM DRAIN LINE M s f RENTON STANDARD DETAIL 262.20 ON ® CATCH BASIN $� $b O —sD sD SD SHEET C5.52. CONTRACTOR SHALL C5.50 C5.50 PROTECT BIORETENTION AREA DURING 1 5 00 00 CONSTRUCTION TO PREVENT °y COMPACTION OR SILTATION. CLEANOUT C5.52 d ss ss 11 BIORETENTION ID ® CONNECT TO EXISTING STORM STRUCTURE. CONTRACTOR SHALL 1 O CONFIRM LOCATION AND ELEVATION OF CURB INLET C5.51 STRUCTURE AND CONNECTED PIPES AND NOTIFY ENGINEER OF ANY BIOPOD DISCREPANCIES. 5. PLACE ETHAFOAM PAD BETWEEN PIPE CROSSINGS WITHIN LESS THAN 18" CLEARANCE. 6. ALL STORM DRAINAGE PIPE 12" OR LARGER SHALL BE TYPE S, LINED CORRUGATED POLYETHYLENE (LCPE) PER WSDOT STANDARD SPECIFICATIONS 9-05.19 UNLESS INDICATED OTHERWISE. DUCTILE IRON STORM DRAIN PIPE NAF'cd 1cpff i4°M1� 0 10' zo' 40' Ii 1 1I = 20 % HORZ 47 16015th Avenue, Suite 1600 0 2.5' 5' 10' o RACISTSeattle, WA 98101 �9g(ONAL W6t'V 2W.622.5822 1 inch = 5 k. YIItT www.kpTf.cam 3/11/2022 M,. AS NOTED a4`°""'°'°"n°°' CITY OF Vaff' RENTON �� DATUM � caw,w Planning/Building/Public OF Dept. IF NOT ONE INCH R-417859 IN COMPLIANCE WITH CITY OF RENTON STANDARDS SURFACE WATER UTILITY DEVELOPMENT ENGINEERING JFarah04/01/2022 11 msipp004/07/2022 O SOLERA 2842 NE SUNSET BLVD RENTON, WA 98056 GRADING AND STORM DRAINAGE NE SUNSET BOULEVARD PLAN AND PROFILE DI NO C5.17 59 14z