HomeMy WebLinkAboutR-417876NW 1/4 OF THE NW 1/4 AND THE NE 1/4 OF THE NW 1/4 SECTION 9, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M.
00
Hit
I
O
W
H
Q
LU
J
O
C7
k
MATERIAL LOCATION
DESCRIPTION
AASHTO MATERIAL
CLASSIFICATIONS
COMPACTION / DENSITY REQUIREMENT
ITNALFIL4 FILL MATERIAL FOR LAYER 'D'
STARTS FROM THE TOP OF THE 'C' LAYER
ANY SOIL/ROCK MATERIALS, NATIVE SOILS,
PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED
a
TO THE BOTTOM OF FLEXIBLE PAVEMENT
OR PER ENGINEER'S PLANS. CHECK PLANS
N/A
INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND
OR UNPAVED FINISHED GRADE ABOVE.
FOR PAVEMENT SUBGRADE REQUIREMENTS.
PREPARATION REQUIREMENTS.
NOTE THAT PAVEMENT SUBBASE MAY BE
PART OF THE V LAYER
INITIAL FILL FILL MATERIAL FOR LAYER
AASHTO M145'
BEGIN COMPACTIONS AFTER 12" (300 mm) OF
C' STARTS FROM THE TOP OF THE
GRANULAR WELL -GRADED SOIL/AGGREGATE
A-1, A-2-4, A-3
MATERIAL OVER THE CHAMBERS IS REACHED.
EMBEDMENT STONE ('B' LAYER) TO 18"
MIXTURES, <35% FINES OR PROCESSED
COMPACT ADDITIONAL LAYERS IN 6" (150 mm) MAX
c
AGGREGATE.
OR
UFTS TO A MIN. 95% PROCTOR DENSITY FOR WELL
(450 mm) ABOVE THE TOP OF THE
GRADED MATERIAL AND 95% RELATIVE DENSITY FOR
CHAMBER. NOTE THAT PAVEMENT
MOST PAVEMENT SUBBASE MATERIALS CAN
AASHTO M43
PROCESSED AGGREGATE MATERIALS. ROLLER GROSS
SUBBASE MAY BE A PART OF THE 'C'
BE USED IN UEU OF THIS LAYER.
3, 357, 4, 467, 56, 57,,
VEHICLE WEIGHT NOT TO EXCEED 12,000 Ibs (53 W).
LAYER.
8, 10
DYNAMIC FORCE NOT TO EXCEED 20,000 Ibs (89 M).
EMBEDMENT STONE: FILL SURROUNDING
B
THE CHAMBERS FROM THE FOUNDATION
'C'
CLEAN, CRUSHED, ANGULAR STONE
AASHTO M43'
NO COMPACTION REQUIRED.
STONE ('A' LAYER) TO THE LAYER
3, 3579 4, 467, 5, 56, 57
ABOVE.
FOUNDATION STONE: FILL BELOW
A
CHAMBERS FROM THE SUBGRADE UP TO
CLEAN, CRUSHED, ANGULAR STONE
AASHTO M43'
PLATE COMPACT OR ROLL TO ACHIEVE A FLAT
THE FOOT (BOTTOM) OF THE CHAMBER.
3, 357, 4, 467, 5, 56, 57
SURFACE. ' '
PLEASE NOTE:
1. THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4
STONE WOULD STATE: "CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE'.
2. WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING
OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR COMPACTION REQUIREMENTS.
Call 811
• twoC business days
before you dig
BEGIN/END LINER AT TOP OF STONE -�,
PERIMETER STONE
(SEE NOTE 6)
EXCAVATION WALL
(CAN BE SLOPED OR VERTICAL)
ADS GEOSYNTHETICS 601T NON -WOVEN
GEOTEXTILE ALL AROUND CLEAN, CRUSHED, 1 LAYER OF ADS GEOSYNTHETICS NON -WOVEN
ANGULAR STONE IN A & B LAYERS7I, / GEOTEXTILE BEWWEEN COVER STONE AND C LAYER.
n
6" MINEND3500 CAP S� ADE SOILS— J/ MIN
(SEE NOTE 4) PVC UNER
(SEE NOTE 8)
3
1. MC3500 CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418-16a, "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS"
CHAMBER CLASSIFICATION 451 DESIGNATION SS.
2. SC-310 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION
CHAMBERS".
3. "ACCEPTABLE FILL MATERIALS" TABLE ABOVE PROVIDES MATERIAL LOCATIONS, DESCRIPTIONS, GRADATIONS, AND COMPACTION REQUIREMENTS FOR FOUNDATION, EMBEDMENT, AND FILL MATERIALS.
4. THE GEOTECHNICAL ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH
CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS.
5. PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS.
6. ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL
REQUIREMENTS OF LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION.
7. MINIMUM COVER OF 18 INCHES REQUIRED TO BOTTOM OF PAVEMENT. FOR UNPAVED AND TEMPORARY INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR, COVER SHALL BE INCREASED TO
A MINIMUM OF 30 INCHES.
B. CHAMBER SYSTEM BOTTOM AND SIDES SHALL BE UNED WITH A NON —REINFORCED 30 MIL PVC LINER. LINER SHALL BE BETWEEN PERIMETER STONE/BOTTOM OF STONE AND SUBGRADE SOILS.
STORMTECH MC-3500 FILL MATERIALS
NTS (PER STORMTFDH - MOI)IFIFD BY KPFFI
CIVIL CONSTRUCTION PERMIT
CIVIL CONSTRUCTION PERMIT RESUBM17AL
CIVIL CONSTRUCTION PERMIT RESUBMITTAL
REVISION
BY I DATE I APPR
AS NOTED a':mow Nm9°°n°°,
DATUM
AT Eu
IF NOT ONE INCH
lcpff
36015th Avenue, Suite 1600
Seattle, WA 98101
2015.622.5822
www.kpff.com
= CITY OF
' FENTON
viav
Planning/Building/Public Works Dept.
R-417876
IN COMPLIANCE WITH CITY OF RENTON STANDARDS