HomeMy WebLinkAboutMFP22001689.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Major Franchise Permit: MFP22001689
IVR Number: 22001689
Permit Information
Permit Name: Puget Sound Energy - Electric
Address/Location:04/04/2022Application Date:3342103464Parcel Number: 1616 NE 30TH ST
Permit Type:04/21/2022Issue Date:Franchise
Permit Work Class:04/21/2023Expiration Date:Major Utility
Job Number: 101114032Franchise Type:Electric
Description: Puget Sound Energy Electric REPLACE EXPIRED PERMIT MFP18006587 CREW TO REPLACE
TERMINATIONS AND SPLICES ALONG WITH REPLACING (3) PRIMARY CABLES IN CONDUIT SPANNING ± 803'.
THIS PROJECT ALSO REQUIRES A WSDOT PERMIT WHICH WAS APPLIED FOR IN SEPTEMBER. WILL REQUIRE
CLOSURE OF ONE WESTBOUND LANE OF KENNEWICK PL NE APPROCHING I 405 AND ANOTHER CLOSURE
ON THE OTHER SIDE OF I 405 AT THE EASTBOUND NE 30TH ST RIGHT HAND TURN LANE ADJACENT TO
SOUTHBOUND I 405 ENTRANCE. PRE CONSTRUCTION MEETING REQUIRED. RESTORATION PER CITY OF
RENTON STANDARDS.
Contacts
Name Address PhoneTypeBilling
Corrie Rydberg
Puget Sound Energy
3702 71st Ave W
University Place, WA 98466
C: (253) 905-5031ApplicantX
Vicki Henson
Potelco Inc
8001 212th St S
Kent, WA 98032
B: (253) 863-0484Contractor
Business License Number: 5109Electrical Contractor: POTELI*344O4
Construction Contractor: POTELI*227PL
BARAKAH LLC 1616 NE 30TH ST
RENTON , WA 98056
Owner
Corrie Rydberg
Puget Sound Energy
3702 71st Ave W
University Place, WA 98466
C: (253) 905-5031Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF PUBLIC WORKS
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 1 of 2 | Published: 1ϭ/Ϯϱ/2019
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN (TCP) APPLICATION
Published: 1ϭ/Ϯϱ/2019
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and
obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
TO THE APPLICANT: Submit the TCP application form and required submittal documents to
TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address.
The following items, electronic copies preferred, are all required for submittal of the TCP Application:
1.܆ A copy of the Traffic Control Plan (TCP) Application form.
2.܆ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall:
܆ Include map(s) showing the location of the project and work area.
܆ Be legible lettering and clear, contrasting, symbols of viewing or printing.
܆ Must indicate street names, and north arrow and scale.
܆ All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State
Traffic Control Flagger Certification handbook, by the Evergreen Safety Council.
܆ Types of plans required:
܆ Work hour plan – show all mobility impacts during construction hours.
܆ Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
܆ Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
܆ Pedestrian access/detour plan, if applicable.
Project Name: ______________________________________________ Permit #: _____________________
Project Address: ____________________________________________________________________________
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Description of Work, Work Schedule, Equipment Used: _____________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
Construction Company: ________________________________________ Phone/Cell: (_____) _____-________
Applicant Name: _________________________________ Email: ______________________________________
Business Address: _________________________________ City/State: __________________ Zip: __________
Approved By: _______________________________________________ Date: ________________________
Transportation Operations Engineering
4
4
4
4
4
4
4
4
4
4
4
101114032
1616 NE 30TH ST
POTELCO, INC 425 892 0416
MIGUEL.REYNA@PSE.COM
6905 S. 228TH ST KENT, WA 98032
MFP22001689
Scott Warlick CED 4/20/2022
This work shall take place on Saturday or at night. Night work will
require a noise variance because we are within 300-feet of a
residential zone.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 2 | Published: 1ϭ/Ϯϱ/2019
APPLICANT AGREES TO ALL THE FOLLOWING:
x TCP must be approved prior to commencing the work, and all permit conditions shall be met.
x Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner
at a time, with the least possible inconvenience or delay to pedestrians.
x Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or
slippery road conditions during work and non-work hours.
x The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of
traffic. This includes set up within the traveled way or immediately adjacent to the roadway.
x Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures.
x Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including
public transit, to be affected by a temporary lane or road closure.
x TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on
Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT)
and all traffic regulations of the City of Renton and Revised Code of Washington (RCW).
x Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or
Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State
and City codes.
x Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles
and the acts of the Applicant’s agents and employees.
x The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and
in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s
reasonable attorney’s fees and litigation costs incurred resulting from such claim.
x In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay
for legal counsel chosen by the City to defend against same.
x Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
x Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
x Approved Temporary TCP must be at the work site during work hours.
x Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
x Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
x Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations
for vacate parking or curb lane usage.
x Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
x The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site.
x Temporary traffic control devices must be removed immediately when work is done or no construction
activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance
shop (3555 NE 2nd Street; 425-430-7423).
_______________________________ _______________________________ _______________________
Applicant’s Signature Print Name Date
CORRIE RYDBERG
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
03/08/2022
101114032
7
1616 NE 30TH ST, RENTON, 98056, WA
YURIY BASHTOVOY
(425) 424-6603
Yuriy.Bashtovoy@PSE.COM
1 OF 4
TEMPORARY TRAFFIC CONTROL PLAN
WSDOT NOTES & TABLES
Puget Sound Energy
Traffic Control Supervisor:
Yuriy S. Bashtovoy
Card No. 011687
Card Exp. 06/30/2022
Yuriy.Bashtovoy@pse.com
(425)424-6603
””
–
VICINITY MAP
NE 30TH STKENNEWICK PL NE11111121 BUSONLYPV2ARRW-BRD
BUSSTOPW4-2LRIGH
T
L
A
N
ECLOSE
D
AHEAD
W20-5R100'100'100'ROADWORKAHEAD
W20-1
SI
D
E
W
A
L
K
C
L
O
S
E
D
R9-9SIDEWALKCLOSEDR9-9ROADWORKAHEADW20-1
100'
R9-11SID
EWAL
KCLOSEDAHEA
DNE 29TH
STR9-11SIDEWALKCLOSEDAHEADDETOURM4-9bPARK AVE NPO1PV1INTERSTATE405INTERSTATE405 ROADWORKAHEADW20-1X'
111122 SPOTTER SHALLESCORT PEDESTRIANSAROUND WORK AREAROADWORKAHEADW20-1100'11
1111
11
ARCOGasStationChevronGas StationSW1PT1PT2OTHER SIDES/W CLOSEDOTHER SIDE
S/W CLOSED2121
1122 NE 30TH STONLYR3-5RONLYR3-5RONLYR3-5RONLYR3-5RONE WAY R3-6RONE WAY
ONE WAY
ONE WAY
LBIKE LANE
CLOSED
DATETIMEX DAYS
RAMP WILL BE R11-1501EXIT CLOS
E
D
INSTALL3 DAYSPRIOR TOCLOSURERAMP
CLOSEDAHEAD W20-3RAMPCLOSEDAHEADW20-3100'TEMPORARY TRAFFIC CONTROL PLAN28" TRAFFIC CONELEGENDWORK PITTRAFFIC FLOWSIGN LOCATIONFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPCHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYNotes:1. Notify WSDOT (206) 440-4467 at least 5 daysprior to scheduled projects.2. All advanced warning signs and spacing to conform to theMUTCD and WSDOT standards.3. Channelizing devices shall be traffic drums (barrels) withsteady burning Type C lights on all State Routes andHwys.4. All signs are 48" x 48", Black legend on Orange background.Use class B signs unless otherwise specified.5. Flaggers shall be in radio contact with each other at alltimes; flagger stations shall be illuminated during hoursof darkness with minimum 150w lights6. All lane closures shall not infringe upon adjacentlanes.7. Alert affected residents and businesses if existing onWSDOT roadways. All sidewalks, driveways, exits andegresses shall be completely clear unless otherwiseindicated.8. Work areas will be noted as per distances betweenState Route milepost markers.9. See sheet 1 for WSDOT Notes and Tables.0'90'45'PRINT ON11X17" SHEETS ONLYNProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REV03/08/2022 10111403271616 NE 30TH ST, RENTON, 98056, WA YURIY BASHTOVOY (425) 424-6603 Yuriy.Bashtovoy@PSE.COM2 OF 4Puget Sound EnergyTraffic Control Supervisor:Yuriy S. BashtovoyCard No. 011687Card Exp. 06/30/2022Yuriy.Bashtovoy@pse.com(425)424-6603TRAFFIC CAFETY DRUMSWITH TYPE C LIGHTSMATCHLINESHEET 3SHEET 2this traffic controlplan will requireWSDOT approval
12 12 12
12 12 12L/3500'SHOULDERWORKW21-5ROADWORKAHEADW20-1TYPE-3
R11-201
RAMPCLOSED
PLACE PCMS BOARDS 1 MILE
BEFORE WORK AREA.
TWO-SECOND SEQUENCE
2-LINE, 8 CHARACTER
MESSAGES WILL READ:
1)
2)
EXIT 6
CLOSED
USE
EXIT 5 1 MILEBEFOREWORK AREAPCMSTYPE-3
R11-201
RAMPCLOSED 100'100'100'SHOULDERCLOSEDW21-5ARAMPCLOSEDAHEADW20-3BIKE LANE
CLOSED
DATE
TIME
X DAYS
RAMP WILL B
E
R11-1501
INSTALL
3 DAYS
PRIOR TO
CLOSUR
E
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
03/08/2022
101114032
7
1616 NE 30TH ST, RENTON, 98056, WA
YURIY BASHTOVOY
(425) 424-6603
Yuriy.Bashtovoy@PSE.COM
3 OF 4
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound Energy
Traffic Control Supervisor:
Yuriy S. Bashtovoy
Card No. 011687Card Exp. 06/30/2022
Yuriy.Bashtovoy@pse.com
(425)424-6603
0'90'45'
PRINT ON
11X17" SHEETS ONLYN
MATCHLINE SHEET 3
SHEET 2
28" TRAFFIC CONE
LEGEND
WORK PIT
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
UNIFORMEDPOLICE OFFICERPOLICE
STOP
CHEVRONARROW BOARD
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
Notes:
1. Notify WSDOT (206) 440-4467 at least 5 days
prior to scheduled projects.
2. All advanced warning signs and spacing to conform to the
MUTCD and WSDOT standards.
3. Channelizing devices shall be traffic drums (barrels) with
steady burning Type C lights on all State Routes and
Hwys.
4. All signs are 48" x 48", Black legend on Orange background.
Use class B signs unless otherwise specified.
5. Flaggers shall be in radio contact with each other at all
times; flagger stations shall be illuminated during hours
of darkness with minimum 150w lights
6. All lane closures shall not infringe upon adjacent
lanes.
7. Alert affected residents and businesses if existing on
WSDOT roadways. All sidewalks, driveways, exits and
egresses shall be completely clear unless otherwise
indicated.
8. Work areas will be noted as per distances between
State Route milepost markers.
9. See sheet 1 for WSDOT Notes and Tables.
TRAFFIC CAFETY DRUMS
WITH TYPE C LIGHTS
this traffic control
plan will require
WSDOT approval
NE 30TH STKENNEWICK PL NE111111 2121 BUSONLYBUSSTOPPARK AVE N10SIDEWALKCLOSEDR9-9SIDEWALK
CLOSEDR9-9DETOURM4-9bR9-11SIDEWALKCLOSEDAHEADDETOURM4-9b1111
ROADWORKAHEAD W20-1100'ROADWORKAHEADW20-1100'INTERSTATE405INTERSTATE40511
11 11 1121SPOTTER SHALLESCORT PEDESTRIANSAROUND WORK AREAROADWORKAHEADW20-1X'X'X'RIGHT LANECLOSEDAHEADW20-5RM6-2ARCOGasStationChevronGas StationPV1P01PV221R3-6RONE WAY
ONE WAY
ONE WAY
ONE WAYNotes:1. Notify WSDOT (206) 440-4467 at least 5 daysprior to scheduled projects.2. All advanced warning signs and spacing to conform to theMUTCD and WSDOT standards.3. Channelizing devices shall be traffic drums (barrels) withsteady burning Type C lights on all State Routes and Hwys.4. All signs are 48" x 48", Black legend on Orange background.Use class B signs unless otherwise specified.5. Flaggers shall be in radio contact with each other at alltimes; flagger stations shall be illuminated during hours ofdarkness with minimum 150w lights6. All lane closures shall not infringe upon adjacent lanes.7. Alert affected residents and businesses if existing onWSDOT roadways. All sidewalks, driveways, exits andegresses shall be completely clear unless otherwiseindicated.8. Work areas will be noted as per distances between StateRoute milepost markers.9. See sheet 1 for WSDOT Notes and Tables.0'90'45'PRINT ON11X17" SHEETS ONLYNProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REV03/08/2022 10111403271616 NE 30TH ST, RENTON, 98056, WA YURIY BASHTOVOY (425) 424-6603 Yuriy.Bashtovoy@PSE.COM4 OF 4Puget Sound EnergyTraffic Control Supervisor:Yuriy S. BashtovoyCard No. 011687Card Exp. 06/30/2022Yuriy.Bashtovoy@pse.com(425)424-6603TEMPORARY TRAFFIC CONTROL PLAN28" TRAFFIC CONELEGENDWORK PITTRAFFIC FLOWSIGN LOCATIONFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPCHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYTRAFFIC CAFETY DRUMSWITH TYPE C LIGHTS
WORK SITE
319238-166345
NEW AØEHR874
NEW BØEHR875
NEW CØEHR876
319228-166270
X0607
R
HLWS
319230-166277 ROWROWROWROWROW ROW ROW ROW
R
O
W
ROW
ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW
ROWROWROWROWROWROWROWROW
319228-166270
X0607
R
HLWS
319235-166342
U0329
319230-166277
336.4 MCMACSR
WSDOT
SERVICE CABINET
E.O.P.
E.O.P.E.O.P.
E.O.P.
E.O.P.
E.O.
P
.E.O
.
P
.E.O.P.E.O.P.E.O.P.E.O.P.E.O.P.E.O.P.E.O.P.E.O.P.I-405 EXITI-405 EXITI-405 ENTRANCEI-405 ENTRANCES/WS/W
S/W S/W
S/W
S/W
S/W
S/W
S/WEND OF
BRIDGEEND OF
BRIDGE
GAS
PHONE
CABLE TV
N/A N/A
N/A N/A
N/A 108108034
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
Perm. Service
Relocation
Removal
TUT Retirement
Job Order
Distribution
HP Main
HP Svc/MSA
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"
X
X
X
X
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)101114032Owner / Developer Contact Info
officeATTN:
N
Vicinity Map
NOT TO SCALE
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Correct QC Checklist(s) reviewed.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
OVERHEAD CIRCUIT MAP
SCALE: 6" = 1 MILE MAP#: 2405E136
UNDERGROUND CIRCUIT MAP
SCALE: 1" = 50' MAP#: 2405E127
11445846 101114032
SITE MAP
SCALE: 1" = 50'
THOMAS GUIDE
626-D4
9.
7.
6.
5.
4.
3.
2.
1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from
this work sketch must be AUTHORIZED by Potelco's Project Manager and NOTED on the Foremans' Copy.
All switching arrangements and/or outage arrangements are to be made with the Project Manager at least
three (3) working days in advance.
Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing
work to get the underground facilities located.
STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk,
etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager.
SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction
materials which would restrict construction and/or equipment access, before work can begin.
CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from
combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard
posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water,
storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them.
All work is to be done in accordance with local municipal and county permit requirements as applicable.
Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits
and crossings from the individual unit's meter base to the designated connection point.
EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and
restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over
PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer
will provide any and all shoring or they will side slope the trench to 1:1.
8.
POWER GENERAL NOTES SITE SPECIFIC NOTES
PT1 & PT2
-CREW TO LOCATE EDGE OF BRIDGE TO APPROACH SLABS ON EAST & WEST SIDE OF BRIDGE
-SAW CUT ASPHALT (2) 5'X10'
-PITS NOT TO ENCROACH INTO BRIDGE ABUTMENT OR APPROACH SLABS TO AVOID COMPROMISE
OF ANY STRUCTURAL INTEGRITY OR DISTURBANCE OF SOIL BENEATH
-EXCAVATE DIRT W/ VAC TRUCK APPROX. 5' DEEP TO EXPOSE BROKEN CONDUIT
-NO INJECTION OF WATER INTO THE SOIL IN THE IMMEDIATE VICINITY OF BRIDGE
ABUTMENTS/APPROACH SLABS IS PERMITTED
-CUT DAMAGED CONDUIT & WIRE
-PULL EXISTING WIRE OUT THROUGH THE HANDHOLES
-INSTALL NEW PORTION OF CONDUIT & ATTACH TO THE EXISTING NON-DAMAGED CONDUIT
-COMPACT BACK FILL AREA & COLD PATCH/ASPHALT REPAIR
SW1 (319235-166342)
-REPLACE (3) 750 MCM TERMINATIONS ON P0S. (TER750C) PER STD. 6041.3000
PV1 (319230-166277)
-REMOVE (3) 750 MCM HAMMERHEAD SPLICES
-INSTALL (3) NEW 750 MCM STRAIGHT SPLICES (SPL750) PER STD. 6041.2000
PV2 (319229-166341)
-REMOVE (3) 750 MCM HAMMERHEAD SPLICES
**CREW TO PULL NEW CABLE STRAIGHT THROUGH VAULT TO SWITCH
**EXISTING RUN OF 1/0 CABLES IN VAULT. WILL NEED TO DE-ENERGIZE AT J-BOX
**COMMERCIAL OUTAGE REQUIRED
P01 (319228-166270)
-REPLACE (3) 750 MCM TERMINATIONS (TSU3NF1) PER STD. 6043.1020
**SHRUB REMOVAL REQUIRED ENCOMPASSING ENTIRE AREA BETWEEN SW1 & PV2
**WSDOT FACILITIES INCLUDING SERVICE CABINET AND ITS POWER OPERATION WILL NOT BE
DISTURBED.
SPAN SPECIFIC NOTES
SW1 TO P01
-DIG (2) 5'x10'-15' PITS & REPAIR CONDUIT IN BOTH (PITS#1 & 2) W/ NEW CONDUIT AS NECESSARY
ON EACH SIDE OF BRIDGE
-REPLACE B/O 750 MCM FEEDER CABLES IN CONDUIT, L = ± 803'
-INSTALL NEW CABLE TAGS AØEHR874, BØEHR875, CØEHR876
-SAW-CUT ROAD (APPROX. 5'X10'-15')
-HYDRO EXCAVATE DIRT TO EXPOSE THE CONDUIT (CONDUIT IS USUALLY BURIED AT 48") TO
AVOID DISTURBANCE OF BRIDGE ABUTMENTS & APPROACH SLABS
-CUT DAMAGED CONDUIT & WIRE
-PULL EXISTING WIRE THROUGH THE HANDHOLES
-INSTALL NEW PORTION OF CONDUIT & ATTACH TO THE EXISTING NON-DAMAGED CONDUIT
-COMPACT BACK FILL AREA & COLD PATCH/ASPHALT REPAIR
**PER STANDARDS CONDUIT IS BURIED AT A MAX 48". THIS CAN BE MORE SINCE THE SETTLING
OF THE BRIDGE MIGHT OF CAUSED THE CONDUIT TO BE DEEPER
**THE SIZE OF THE TWO TRENCHES WILL BE APPROXIMATELY 5'X10'-15'X48'. RESTORATION WILL
BE TO COMPACT BACKFILL OF 1' LIFTS PER CONSTRUCTION CODE
**NO OTHER GROUND DISTURBING WORK OUTSIDE OF THE TWO PITS FOR CONDUIT REPAIR
CIRCUIT FEET ADDED: NONE
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
M. REYNA 425-748-6365 08/06/18
S. FOX 714-893-2405 08/06/18
D. FIELDS 714-893-2405 08/06/18
N/A RENTON / WSDOT
HIG-15, CREW2, 1616 NE 30TH ST
REPLACE B/O FEEDER CABLES
1616 NE 30TH ST, RENTON, 98056
ASPLUNDH CONSTRUCTION CORP.
O-443883
101114032
AS NOTED 1/1
KING FAC-SVC
SW 32-24N-05E
2405E127 2405E136 HIG-152405E127
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:MIGUEL REYNA
425-429-1201
MIGUEL.REYNA@PSE.COM
PRIMARY CABLE REMOVAL TABLE
LOCATION PRIMARY CABLE
ASBUILT INFORMATION
Cable LENGTH
Design
(ft)
Cable Numbers Please Record Foreman - Complete
FROM TO Size A B C Manufacturer Year Actual Amount Installed (Conduit & Cable)
SW1 P01 750 803'31106 31107 31108
PRIMARY CABLE TABLE - INSTALL
LOCATION CABLE ASBUILT INFORMATION - FOREMAN COMPLETE
FROM TO QT
Y.
BENDS PULL
(LBS)
PULL
REV
(LBS)
CABLE
SIZE
DESIG
N
LENGT
H (FT)
PHASE - ID TAG RECORD RECORD PHASE TAPPED & ACTUAL FOOTAGE INSTALLED
90°45°22°11°A B C MANUFACTURER COMPOUND YEAR NOTES CABLE
SW1 PV1 3 2 750 755'-0"EHR874 EHR875 EHR876
PV1 P01 3 1 750 48'-0"EHR874 EHR875 EHR876
TOTAL 803'-0"
FOREMAN PLEASE FILL IN
YEAR MANUFACT:
CABLE #:
MANUFACTURER:
LENGTH:
EHR874
FOREMAN PLEASE FILL IN
YEAR MANUFACT:
CABLE #:
MANUFACTURER:
LENGTH:
EHR875
FOREMAN PLEASE FILL IN
YEAR MANUFACT:
CABLE #:
MANUFACTURER:
LENGTH:
EHR876
Pre-Construction meeting required
RESTORATION PER CITY OF RENTON STANDARDS
MFP22001689
This permit is for Major construction work in the ROW and will be billed at an additional
$60/HR for inspections. After hours and weekend work will be billed at $125/HR