Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
McKee Top GOlf 7-16-21 Report
GraniteNet INSPECTION / DECISION SUPPORT SOFTWARE • CUES, Inc. 3600 Rio Vista Avenue Orlando, FL 32805 Phone: 407-849-0190 Fax: 407-425-1569 PACP v7.0 Inspections and Scoring General Information: Surveyed by: PACP certificate no.: Reviewed by: Michael B P/O number: � Work order no.: I Media label: � Pre -cleaning: Sheet number: Weather: 1 H Direction: Technology used: U Location: Drainage area: Pipe segment ref.: CO#1 - SSMH#5 City: RENTON Pipe: Pipe use: SS Coating method: Measurements: Upstream MH No: CO#1 Downstream MH No: SSMH#5 MH coordinate system: Height: 6 in. Pipe joint length: Additional Information: Location code: Width: Total length: 125.500 ft. Reviewer certificate no. Owner: Project name: MCKEE ENTERPRISES, LLC #21.03 TOP GOLF Date cleaned: Flow control: Inspection status: Street: LOGAN AVE N Location details: Shape: C Length surveyed: 125.500 ft. Rim to invert: Rim to grade: Grade to invert: Rim to invert: Rim to grade: Grade to invert: MH vertical datum: GPS accuracy: Consequence of failure: Material: PVC Year constructed: Northing: Easting: Customer: I Start date/time: 20210716 08:06 Purpose: Pressure value: Lining method: Year renewed: Elevation: Northing: Easting: Elevation: PACP v7.0 Inspections and Scoring Page 1 of 12 Pipe Ratings Grade Structural: Amount of Segment Pipe Quick Pipe Rating Defects Grade Ratinq Ratinq Index 0&M: Amount of Segment Pipe Quick Pipe Rating Defects Grade Ratino Ratinq Index Overall: Pipe Rating Pipe Rating LoF Risk Index 1 0 0 0 0000 0.0 0 0 0 0000 0.0 0 0.0 1.0 2 0 0 0 0 3 0 0 0 0 4 0 0 0 0 5 0 0 0 0 Observations Distance Video Ref. PACP Code Continuous Value Inches % Joint Circumferential Rating Image Ref. Remarks (mm) Location 1st 2nd At/From To 0.0 ft. AMH ❑ / 0.0 ft. MWL 5 ❑ / 125.5 ft. 00:07:23 TF 6.000 ❑ 12 / 125.5 ft. 00:07:38 ACOM ❑ / MCKEE ENTERPRISES_ LLC #21.03 TOP GOLF --- TF at 125.5 ft..JPG MCKEE ENTERPRISES_ LLC #21.03 TOP GOLF --- ACOM at 125.5 ft..JPG SSMH#5 T REACHED END OF RUN AT CLEANOUT. PACP v7.0 Inspections and Scoring Page 2 of 12 PACP v7.0 Inspections and Scoring General Information: Surveyed by: PACP certificate no.: Reviewed by: Reviewer certificate no. Owner: Customer: Michael B P/O number: Work order no.: Media label: Project name: Start date/time: Sheet number Direction: D Location: Drainage area: City: RENTON Pipe: Pipe use: SS Coating method: Measurements: Upstream MH No: SSMH#5 Downstream MH No: SSMH#4 MH coordinate system: MCKEE ENTERPRISES, LLC #21.03 TOP GOLF 20210716 08:27 Weather: Pre -cleaning: Date cleaned: Flow control: Purpose: 1 I H Technology used: Inspection status: Consequence of failure: Pressure value: Pipe segment ref.: Street: SSMH#5 - SSMH#4 LOGAN AVE N Location code: Location details: Height: Width: Shape: Material: 8 in. I C PVC Pipe joint length: Total length: Length surveyed: Year constructed: 115.700 ft. 115.700 ft. Additional Information: Rim to invert: Rim to invert: MH vertical datum: Rim to grade: Rim to grade: Grade to invert: Northing: Easting Grade to invert: Northing: Easting: GPS accuracy: Lining method: Year renewed: Elevation: Elevation: PACP v7.0 Inspections and Scoring Page 3 of 12 Pipe Ratings Grade Structural: Amount of Segment Pipe Quick Pipe Rating Defects Grade Ratinq Ratinq Index 0&M: Amount of Segment Pipe Quick Pipe Rating Defects Grade Ratino Ratinq Index Overall: Pipe Rating Pipe Rating LoF Risk Index 1 0 0 0 0000 0.0 0 0 0 0000 0.0 0 0.0 1.0 2 0 0 0 0 3 0 0 0 0 4 0 0 0 0 5 0 0 0 0 Observations Distance Video Ref. PACP Code Continuous Value Inches % Joint Circumferential Rating Image Ref. Remarks (mm) Location 1st 2nd At/From To 0.0 ft. AMH ❑ / 0.0 ft. MWL 5 ❑ / 115.7 ft. 00:05:21 AMH ❑ / SSMH#5 MCKEE END OF INSPECTION ENTERPRISES_ LLC #21.03 TOP GOLF---AMH at 115.7 ft..JPG PACP v7.0 Inspections and Scoring Page 4 of 12 PACP v7.0 Inspections and Scoring General Information: Surveyed by: PACP certificate no.: Reviewed by: Reviewer certificate no. Owner: Customer: Michael B P/O number: Work order no.: Media label: Project name: Start date/time: Sheet number Direction: U Location: Drainage area: City: RENTON Pipe: Pipe use: SS Coating method: Measurements: Upstream MH No: SSMH#4 Downstream MH No: SSMH#3 MH coordinate system: MCKEE ENTERPRISES, LLC #21.03 TOP GOLF 20210716 08:56 Weather: Pre -cleaning: Date cleaned: Flow control: Purpose: 1 I N Technology used: Inspection status: Consequence of failure: Pressure value: Pipe segment ref.: Street: SSMH#4 - SSMH#3 LOGAN AVE N Location code: Location details: Height: Width: Shape: Material: 8 in. I C PVC Pipe joint length: Total length: Length surveyed: Year constructed: 228.900 ft. 228.900 ft. Additional Information: Rim to invert: Rim to invert: MH vertical datum: Rim to grade: Rim to grade: Grade to invert: Northing: Easting Grade to invert: Northing: Easting: GPS accuracy: Lining method: Year renewed: Elevation: Elevation: PACP v7.0 Inspections and Scoring Page 5 of 12 Pipe Ratings Grade Structural: Amount of Segment Pipe Quick Pipe Rating Defects Grade Ratinq Ratinq Index 0&M: Amount of Segment Pipe Quick Pipe Rating Defects Grade Ratino Ratinq Index Overall: Pipe Rating Pipe Rating LoF Risk Index 1 0 0 4 2200 2.0 0 0 0 0000 19 0.0 4 2.0 2.2 2 2 4 0 0 3 0 0 0 0 4 0 0 0 0 5 0 0 0 0 Observations Distance Video Ref. PACP Code Continuous Value Inches % Joint Circumferential Rating Image Ref. Remarks (mm) Location 1st 2nd At/From To 0.0 ft. AMH ❑ / 0.0 ft. MWL 5 ❑ / 15.3 ft. 00:03:30 MWLS 10 ❑ / 223.9 ft. 00:09:47 MWLS 10 ❑ / 228.9 ft. 00:10:31 AMH ❑ / SSMH#3 2 MCKEE 1/2 INCH SAG ENTERPRISES_ LLC #21.03 TOP GOLF --- MWLS at 15.3 ft..JPG 2 MCKEE 1/2 INCH SAG ENTERPRISES_ LLC #21.03 TOP GOLF --- MWLS at 223.9 ft..JPG MCKEE END OF INSPECTION ENTERPRISES_ LLC #21.03 TOP GOLF---AMH at 228.9 ft..JPG PACP v7.0 Inspections and Scoring Page 6 of 12 PACP v7.0 Inspections and Scoring General Information: Surveyed by: PACP certificate no.: Reviewed by: Reviewer certificate no. Owner: Customer: Michael B P/O number: Work order no.: Media label: Project name: Start date/time: Sheet number Direction: D Location: Drainage area: City: RENTON Pipe: Pipe use: SS Coating method: Measurements: Upstream MH No: SSMH#3 Downstream MH No: SSMH#2 MH coordinate system: MCKEE ENTERPRISES, LLC #21.03 TOP GOLF 20210716 09:18 Weather: Pre -cleaning: Date cleaned: Flow control: Purpose: 1 I H Technology used: Inspection status: Consequence of failure: Pressure value: Pipe segment ref.: Street: SSMH#3 - SSMH#2 LOGAN AVE N Location code: Location details: Height: Width: Shape: Material: 8 in. I C PVC Pipe joint length: Total length: Length surveyed: Year constructed: 283.500 ft. 283.500 ft. Additional Information: Rim to invert: Rim to invert: MH vertical datum: Rim to grade: Rim to grade: Grade to invert: Northing: Easting Grade to invert: Northing: Easting: GPS accuracy: Lining method: Year renewed: Elevation: Elevation: PACP v7.0 Inspections and Scoring Page 7 of 12 Pipe Ratings Grade Structural: Amount of Segment Pipe Quick Pipe Rating Defects Grade Ratinq Ratinq Index 0&M: Amount of Segment Pipe Quick Pipe Rating Defects Grade Ratino Ratinq Index Overall: Pipe Rating Pipe Rating LoF Risk Index 1 0 0 2 2100 2.0 0 0 0 0000 19 0.0 2 2.0 2.1 2 1 2 0 0 3 0 0 0 0 4 0 0 0 0 5 0 0 0 0 Observations Distance Video Ref. PACP Code Continuous Value Inches % Joint Circumferential Rating Image Ref (mm) Location 1st 2nd At/From To 0.0 ft. AMH ❑ / 0.0 ft. MWL 5 ❑ / 49.9 ft. 00:01:56 MWLS 10 ❑ / 283.5 ft. 00:08:56 AMH ❑ / 2 MCKEE ENTERPRISES_ LLC #21.03 TOP GOLF --- MWLS at 49.9 ft..JPG MCKEE ENTERPRISES_ LLC #21.03 TOP GOLF---AMH at 283.5 ft..JPG Remarks SSMH#3 1/2 INCH SAG END OF INSPECTION PACP v7.0 Inspections and Scoring Page 8 of 12 PACP v7.0 Inspections and Scoring General Information: Surveyed by: PACP certificate no.: Reviewed by: Reviewer certificate no. Owner: Customer: Michael B P/O number: Work order no.: Media label: Project name: Start date/time: Sheet number Direction: U Location: Drainage area: City: RENTON Pipe: Pipe use: SS Coating method: Measurements: Upstream MH No: SSMH#2 Downstream MH No: SSMH#1 MH coordinate system: MCKEE ENTERPRISES, LLC #21.03 TOP GOLF 20210716 09:47 Weather: Pre -cleaning: Date cleaned: Flow control: Purpose: 1 I H Technology used: Inspection status: Consequence of failure: Pressure value: Pipe segment ref.: Street: SSMH#2 - SSMH#1 LOGAN AVE N Location code: Location details: Height: Width: Shape: Material: 8 in. I C PVC Pipe joint length: Total length: Length surveyed: Year constructed: 11.900 ft. 11.900 ft. Additional Information: Rim to invert: Rim to invert: MH vertical datum: Rim to grade: Rim to grade: Grade to invert: Northing: Easting Grade to invert: Northing: Easting: GPS accuracy: Lining method: Year renewed: Elevation: Elevation: PACP v7.0 Inspections and Scoring Page 9 of 12 Pipe Ratings Grade Structural: Amount of Segment Pipe Quick Pipe Rating Defects Grade Ratinq Ratinq Index 0&M: Amount of Segment Pipe Quick Pipe Rating Defects Grade Ratino Ratinq Index Overall: Pipe Rating Pipe Rating LoF Risk Index 1 0 0 0 0000 0.0 0 0 0 0000 0.0 0 0.0 1.0 2 0 0 0 0 3 0 0 0 0 4 0 0 0 0 5 0 0 0 0 Observations Distance Video Ref. PACP Code Continuous Value Inches % Joint Circumferential Rating Image Ref. Remarks (mm) Location 1st 2nd At/From To 0.0 ft. AMH ❑ / 0.0 ft. MWL 5 ❑ / 11.5 ft. 00:02:23 AMH ❑ / SSMH#1 MCKEE END OF INSPECTION ENTERPRISES_ LLC #21.03 TOP GOLF---AMH at 11.5 ft..JPG PACP v7.0 Inspections and Scoring Page 10 of 12 PACP v7.0 Inspections and Scoring General Information: Surveyed by: PACP certificate no.: Reviewed by: Reviewer certificate no. Owner: Customer: Michael B P/O number: Work order no.: Media label: Project name: Start date/time: Sheet number Direction: D Location: Drainage area: City: RENTON Pipe: MCKEE ENTERPRISES, LLC #21.03 TOP GOLF 20210716 10:09 Weather: Pre -cleaning: Date cleaned: Flow control: Purpose: 1 I H Technology used: Inspection status: Consequence of failure: Pressure value: Pipe segment ref.: SSMH#1 - SSMH EXISTING Location code: Street: LOGAN AVE N Location details: Pipe use: Height: Width: Shape: Material: SS I 8 in. I C PVC Coating method: Pipe joint length: Total length: Length surveyed: Year constructed: 54.600 ft. 54.600 ft. Measurements: Upstream MH No: Rim to invert: Rim to grade: Grade to invert: Northing: Easting: SSMH#1 Downstream MH No: Rim to invert: Rim to grade: Grade to invert: Northing: Easting: SSMH EXISTING MH coordinate system: MH vertical datum: GPS accuracy: Additional Information: Lining method: Year renewed: Elevation: Elevation: PACP v7.0 Inspections and Scoring Page 11 of 12 Pipe Ratings Grade Structural: Amount of Segment Pipe Quick Pipe Rating Defects Grade Ratinq Ratinq Index 0&M: Amount of Segment Pipe Quick Pipe Rating Defects Grade Ratino Ratinq Index Overall: Pipe Rating Pipe Rating LoF Risk Index 1 0 0 0 0000 0.0 0 0 0 0000 0.0 0 0.0 1.0 2 0 0 0 0 3 0 0 0 0 4 0 0 0 0 5 0 0 0 0 Observations Distance Video Ref. PACP Code Continuous Value Inches % Joint Circumferential Rating Image Ref. Remarks (mm) Location 1st 2nd At/From To 0.0 ft. AMH ❑ / 0.0 ft. MWL 5 ❑ / 54.6 ft. 00:01:28 AMH ❑ / SSMH#1 MCKEE END OF INSPECTION ENTERPRISES_ LLC #21.03 TOP GOLF---AMH at 54.6 ft..JPG PACP v7.0 Inspections and Scoring Page 12 of 12