Loading...
HomeMy WebLinkAboutR-419297CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-26.10 AND POLE SCHEDULE SHEET C\I FURNISH AND INSTALL TYPE //I SIGNAL POLE WITH 40-FT MAST ARM. INSTALL THREE C-) m SIGNAL LEGEND NOTE: THE CONTRACTOR SHALL COORDINATE WITH VE�fffff OE SIGNAL HEADS ONE STREET NAME SIGN ERIC CUTSHALL (425)-430-7423 TO A T, ONE RIO-12A SIGN, ONE ITEMS VIDEO TECTION CAMERA, 61NE GIRS PRECISION POSITONING ANTENNA AND ONE PRE-EMPTION 4 P_ !EVIEW AND DDEETECTOR ON THE MAST ARM. INSTALL ONE SI-I SIGN ONE W16-7PL SIGN AND ONE EX NEW DESCRIPTION 2 4 9 P APPROVE ALL SIGNAL POLE LOCATIONS PRIOR TO RA CAMERA MODEL S4 5 P_ EXTERNAL TERMINAL CABINET ON THE POLE. INSTALL ONE PY2 INFRARED SIQU 0 19211E x 110 JUNCTION BOX TYPE 1,2,8 FOUNDATION INSTALLATION. PD910 INCLUDING A SEPARATE POWER SUPPLY AND POWER CABLE ON LUMINAIRE. SEE POLE EX R W) ICHEDULE ON SHEET TS-04 FOR MOUNTING AND ORIENTATION OF SIGNAL EQUIPMENT. FURNISH __mw VEHICLE SIGNAL HEAD P AND INSTALL ONE CYCLONE DOMM 12OW LED DECORATIVE LUMINAIRE WITH SHORTING CAP PER C) CITY OF RENTON STD. PLAN 117.3. -%-Ni PEDESTRIAN SIGNAL HEAD CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-26.10 AND POLE SCHEDULE SHEET 04 69 TS-04. FURNISH AND INSTALL TYPE //I SIGNAL POLE WITH 30-FT MAST ARM. INSTAL THREE 0 C� I r 4 VEHICLE SIGNAL HEADS ONE STREET NAME SIGN ONE RIO-12A SIGN ONE ITEMS VIDEO I_> MAST ARM MOUNTED SIGN DETECTION CAMERA AND ONE PRE-EMPTION DETECTOR ON THE MAST ARAW. INSTALL ONE SI-I 11� LLJ 7 SIGN ONE W16-7 L SIGN AND ONE EXTERNAL TERA41NAL CABINET ON THE POLE. SEE POLE EMERGENCY PRE-EMPTION S20 S1 r, DETECTOR SCHbULE ON SHEET TS-04 FOR MOUNTING AND ORIENTATION OF SIGNAL EQUIPMENT. FURNISH S 5zi 10 AND INSTALL ONE CYCLONE DOMM 12OW LED DECORATIVE LUMINAIRE WITH SHORTING CAP PER -04 VIDEO CAMERA W-w- CITY OF RENTON STD. PLAN 117.3. 9 9 CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-26.10 AND POLE SCHEDULE SHEET D LIJ TS-04. FURNISH AND INSTALL TYPE //I SIGNAL POLE WITH 40-FT MAST ARM. INSTALL THREE z \ S5 8 VEHICLE SIGNAL HEADS6 ONE STREET NAME SIGN ONE RIO-12A SIGN ONE ITEMS VIDEO -Alto PTZ CAMERA 4 W_ 1C 7 DETECTION CAMERA AN ONE PRE-EMPTION DETECYOR ON THE MAST ARAW. INSTALL ONE SI-I w A 22 SIGN ONE W16-7 L SIGN AND ONE EXTERNAL TERMINAL CABINET ON THE POLE. SEE POLE GPS OPTICOM ANTENNA W I + LJ P S15 SCHbULE ON SHEET TS-04 FOR MOUNTING AND ORIENTATION OF SIGNAL EQUIPMENT. FURNISH 5 TYPE Ii SIGNAL POLE 3 AND INSTALL ONE CYCLONE DOMM 120W LED DECORATIVE LUMINAIRE WITH SHORTING CAP PER CITY OF RENTON STD. PLAN 117.3. CIIIIII�:� SIGNAL POLE TYPE III S6 q CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-26.10 AND POLE SCHEDULE, SHEET P TS-04. FURNISH AND INSTALL TYPE It SIGNAL POLE WITH 25-FT MAST ARM WITH MINIMUM 10 S7 CIRCUMFERENTIAL CLEARANCE FROM OVERHEAD UTILITY LINES. INSTALL TWO VEHICLE SIGNAL A PEDESTRIAN PUSHBUTTON HEADS ONE STREET NAME SIGN ONE RIO-12 SIGN, ONE ITERIS VIDEO DETECTION CAMERA, NW CORNER DETAIL A8 -F AND ONE PRE-EMPTION DETECTOR ON THE MAST ARM. INSTALL ONE SI-I SIGN ONE W16-7PL 0) PS SIGNAL POLE 1:10 SCALE P P�p SIGN AND ONE EXTERNAL TERMINAL CABINET ON THE POLE. SEE POLE SCHEDULE ON SHEET if TS-04 FOR MOUNTING AND ORIENTATION OF SIGNAL EQUIPMENT. CA C:) PPB SIGNAL POLE CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-20.11. FURNISH AND INSTALL TYPE PS 0 S6 la SI -G 6 POLE. RELOCATE ONE PEDESTRIAN SIGNAL HEAD FROM REMOVED HAWK SIGNAL POLE TO THE PS UTILITY POLE G SIGNAL POLE AND ONE APS PUSHOUTTON FROM REMOVED TYPE PRO SIGNAL POLE TO THE PS SERVICE BREAKER SCHEDULE I L �y SIGNAL POLE. PUSHOUTTON SHALL FACE SOUTH, PARALLEL WITH CROSSWALK. C%4 LUMiNAfRE POLE NEW SVC AT DUVALL AVE HE & NE IOTH ST 5 NE CORNER DETAIL CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-20.1 1. FURNISH AND INSTALL TYPE PS o 1:10 SCALE POLE WITH ONE PEDESTRIAN SIGNAL HEAD AND ONE APS PUSHBUTTON. PUSHBUTTON SHALL CIRCUIT BREAKER CONTACTOR LE EMOUNTTON POLE, HALFWAY BETWEEN FAC UTILITY POLE MOUNTED - S !1_=NA1RE ARM AND MAS-r ARM. SEE POLE SPEC E WEST, PARALLEL WITH CROSSWALK. IL LUMINAIRE MAIN 2P-200 AMP --- S4 IS S20 _.HEET FOR COMMENT ON A7rACHMENT ANGLE. CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-20.11. IF FOUNDATION CONFLICTS WITH _P_P_ L, 2 A 2" C EXISTING ILLUA41NATION JUNCTION BOX THE CONTRACTOR SHALL REMOVE AND REPLACE - - - - - - - - - - CONDUITICONDUCTOR SIGNAL IP-40 AMP --- S21 P P S6 12 4CTION BOX IN A LOCATION BEHIND THE SIDEWALK THAT DOES NOT CONFLICT WITH P P PROPOSED SIGNAL EQUIPMENT AND RECONNECT ALL CONDUITICONDUCTORS AS NECESSARY. EED EE3 CONTROLLER CABINET CONTROL IP-15 AMP --- S3 FURNISH AND INSTALL TYPE PS POLE WITH ONE PEDESTRIAN SIGNAL HEAD AND ONE APS P P EX RIN P �_�! �� PUSHBUTTON. POSH13UTTON SHALL FACE WEST, PARALLEL WITH CROSSWALK. SERVICE CABINET ITS IP-20 AMP --- G i=P THIS POLE CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-20.1 1. FURNISH AND INSTALL TYPE PS HI m S2 51 - CONFLICTS WITH POLE WITH ONE PEDESTRIAN SIGNAL HEAD AND ONE APS PUSHBUTTON. PUSHBUTTON SHALL CONSTRUCTION NOTE ILLUM A 2P-20 AMP 30 AMP F -w-w w w wv w 4 v - - - - - - - - - EXISTING SERVICE FACE NORTH, PARALLEL WITH CROSSWALK. 0 ILLUM 0 (SPARE) 2P-20 AMP 30 AMP RIS 4 W�W�w_ CABINET CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-20.1 1. FURNISH AND INSTALL TYPE PS SIGNAL POLE NUMBER ��W-w w w 0 _V�w- 11 � w w W�w, POLE WITH TWO PEDESTRIAN SIGNAL 14EADS AND TWO APS PUSHBUTTONS. PUSHBUTTONS SHALL or) RRFB IP-30 AMP --- S6 BE INSTALLED WITH A SPEECH INFORMATION MESSAGE AS DIRECTED BY THE CITY OF RENTON. 00 A WIRE NOTE ss_ 3 71 0 PUSHBUTTONS SHALL FACE NORTH AND EAST, PARALLEL WITH CROSSWALKS. N IP-20 AMP --- 3 1�t SPARE _SS - CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-20.11. CONTRACTOR SHALL COORDINATE C:) 00+ C -SS I S CONSTRUCTION OF FOUNDATION TO AVOID UNDERMINING EXISTING UTILITY POLE FOUNDATION AND SIGN NOTE SPARE IP-20 AMP --- ss-ss SHALL BRACE EXISTING UTILITY POLE DURING CONSTRUCTION, IF NECESSARY. FURNISH AND C I 0 ITE lilt INSTALL TYPE PS POLE WITH ONE PEDESTRIAN SIGNAL HEAD AND ONE APS PUSHBUTTON. NE 10TH ST 0 4 RELOCATE ONE PEDESTRIAN SIGNAL HEAD FROM REMOVED HAWK SIGNAL POLE TO T14E PS C\J SIGN LEGEND Si SIGNAL POLE AND ONE APS PUSHBUTTON FROM REMOVED TYPE PPB SIGNAL POLE TO THE PS Si SIGNAL POLE. PUSHBUTTON SHALL BE INSTALLED WITH A SPEECH INFORMATION MESSAGE AS THERE IS A &TO 4" 519 Sl Sl DIRECTED BY THE CITY OF RENTON. PUS14BUTTONS SHALL FACE SOUTH AND EAST, PARALLEL 0 WITH CROSSWALKS. C�DNEW STREET NAME SIGN SLOPE HERE. S4 REA40VE EXISTING TYPE PPB SIGNAL POLE AND FOUNDATION. FOUNDATION SHALL BE REMOVED CLARIFYHOWWILL S S2 Duvall Ave IEE] (��)(APPROX. 108-XIS-) THIS BE F­ 1 14 48 CD TO A MINIMUM OF 24" BELOW SURFACE GRADE. RELOCATE EXISTING APS PUSHBUTTON TO NEW CONSTRUCTED. S9 62 C5 v I I I /OLA Ex SIGNAL POLE. RETURN SALVAGED EQUIPMENT TO THE CITY OF RENTON. NEW STREET NAME SIGN LIKELY NEEDS A SS Ss SS S S EXISTING LUMINAIRE POLE TO REMAIN. PROTECT DURING CONSTRUCTION. ss REA40VE EXISTING SERVICE, CONTROLLER CABINETS AND FOUNDATION. REMOVE AFTER PROPOSED �S4 (APPROX. 84"XIS") WALL BEHIND IT. I S3 wv SIGNAL SYSTEM IS OPERATIONAL. FOUNDATION SHALL BE REMOVED TO A MINIMUM OF 24" RELOCATEINEW I S 2 BELOW SURFACE GRADE. RETURN SALVAGED EQUIPMENT TO THE CITY OF RENTON. CONTACT B TRANSPORTATION MANAGER AT 425-430-7423 PRIOR TO CONTROLLER CABINET CONSTRUCTION. SI-1 (36"X36") 2 S S 42 EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN. PROTECT DURING CONSTRUCTION. 3 HEAD TO SIGNAL POLE S5. RELOCATE EXISTING SI-I SIGN AND W16-7PL SIGN, SEE PAVEMENT NEW A� S RIO-12 REMOVE EXISTING HAWK SIGNAL POLE AND FOUNDATION. RELOCATE EXISTING PEDESTRIAN SIGNAL (24"XJO") MARKING AND SIGNAGE PLANS FOR MORE DETAILS. FOUNDATION SHALL BE REMOVED TO A MINIMUM OF 24" BELOW SURFACE GRADE. RETURN SALVAGED EQUIPMENT TO THE CITY OF S, S19 RENTON. 49 RELOCATEINEW _�RIW S THESE RAMP REMOVE EXISTING HAWK SIGNAL POLE AND FOUNDATION. RELOCATE EXISTING PEDESTRIAN SIGNAL W16-7PL LANDINGS WILL HEAD TO SIGNAL POLE SID. RELOCATE EXISTING SI-I SIGN AND W16-7PL SIGN SEE PAVEMENT MARKING AND SIGNAGE PLANS FOR MORE DETAILS. FOUNDATION SHALL BE REfMOVEO CROSSWALK (24-XI2-) NEED TO BE TO A MINIMUM OF 24" BELOW SURFACE GRADE. RETURN SALVAGED EQUIPMENT TO THE CITY OF STOP STOP PARTIALLY 4 S2 RENTON. ON FLASHING RECONSTRUCTED CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 126.2. FURNISH AND INSTALL ON RED RED �6� TO INSTALL THESE TS2-TYPE-I ITS P+ CA81NET SERVICE CABINET, AND UPS SYSTEM ON NEW FOUNDATION PER 0 IF NO PS POLES. CITY OF RENTON STANDARD OLANS 122.1 AND 122.2. THEN PROCEED NEW RIO-12A THISJBOXWILL POWER SOURCE LOCATION IS NOT KNOWN AT TIME OF PLAN PREPARATION. CONTRACTOR SHALL S8 \fj COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. CONTRACTOR SHALL COORDINATE WITH PSE REMOVE (24-XJO-) NEED TO BE FOR SERVICE CABINET ELECTRICAL HOOK-UP, SHALL PREPARE SUBMIT ALL APPLICABLE PERMITS, RIO-23 MOD SW CORNER DETAIL Ir SE CORNER DETAIL RELOCATED TOO AND SHALL PAY ALL ASSOCIATED FEES. CONTRACTOR SHAL ASSUME 500-FT OF TRENCHING (APPROX. 48"X24-) (E�) 1:10 SCALE 1:10 SCALE MAINTAIN EXISTING FOR BIDDING PURPOSES. PSE SHALL MAKE FINAL CONNECTION AND SET THE METER TO POWER R1 ILLUMINATION SOURCE. SIGNAL WIRING SCHEDULE PULL EXISTING FIBER BACK FROM EXISTING CONTROLLER TO EXISTING JUNCTION BOX ROUTE NOTE: SEE CITY OF RENTON STANDA FOR MAST ARM CIRCUITS. MOUNTED STREET NAME SIGN DETAIL RACEWAY VEH PED E. V. V CON ALLUM EXISTING FIBER THROUG14 NEW CONDUIT TO NEW SIGNAL CONTROLLER. IF SUFFICIENT §LACK IS ZL CONDUIT HEAD HEAolpps PREMT. VIDEO FLASH RD PWR. ILLUM FIBER PULL GRND.* CONDUIT NOT AVAILABLE PULL OUT AND REPLACE EXISTING FIBER BACK TO EXISTING FIBER VAULT AT SIZE 4C #8 72SMrO TAPE FILL FILL NORTHWEST C6RNER OF HE 12TH ST AND DUVALL AVE NE. ROUTE NEW FIBER THROUGH 6 (96w) NO. 5C 5C 321aaz EXISTING CONDUIT TO NEW CONTROLLER AT NORTHEAST CORNER OF OF HE 10TH ST AND DUVALL AVE NE. SPLICE EXISTING FIBER WITH NEW IN EXISTING FIBER VAULT. SEE PHASE DIAGRAM SIGNAL DISPLAYS -1 _3 SCH40 �PVC 3 1 1 1 0.79 1.89 INTERCONNECT SCHEMATIC ON SHEET TS-03 FOR MORE DETAILS. 2 2" SCH40 PVC 2 1 0.42 0.86 EXISTING JUNCTION BOX TO REMAIN. IF EXISTING JUNCTION BOX CANNOT REMAIN DUE TO 3 3" SCHBO PVC 3 2 1 1 1 1.07 1.68 SIGNAL POLE CONSTRUCTION THEN REPLACE EXISTING JUNCTION BOX WITH NEW TYPE 2 3" SCHBO PVC SPARE I --- 1.68 JUNCTION 13OX NEAR THIS LOCATION BEHIND THE NEW SIDEWALK. INSTALL NEW JUNCTION BOX WITH CONCRETE PAD PER CITY OF RENTON STANDARD PLANS 120. 4 3 "­SCH40 PVC I I 1 1 0.40 1.89 3 SCHSO 'PVC 4 4 2 2 1 1.61 1 68 REA40VE EXISTING STREET LIGHT POLE AND LUMINAIRE. REMOVE EXISTING FOUNDATION TO A 5 3 �SCHSO pVC 1 1 0.12 MINIMUM 24- BELOW SURFACE GRADE. FILL AND COMPACT VOID. RETURN SALVAGED EQUIPMENT 6 2 SCH40 �PVC I 1 1 0.28 0.86 TO THE CITY OF RENTON. 7 3" SCH40 PVC 3 2 1 1 1 1 0.93 1.89 EXISTING JUNCTION BOX TO REMAIN. ADJUST JUNCTION BOX, AS NEEDED, TO ACCOMMODATE 8 _T5 �SCH40PVC 10 5 5 1 2.19 2.53 NEW IMPROVEMENTS. 3" SCH40 PVC 8 1 1 1.43 1.89 9 3 P­SCH80 PVC 3 1 0.40 IN T-419220 10 2" SCH40 PVC 3 1 1 O�22 0.86 IN COMPLIANCE WITH CITY OF RENTON STANDARDS 11 2" SCH40 PVC 1 0 74 0.86 R-419296 12 _2'SCH8O PVC EX I 1 1 0.74 7.15 13 2" SCH40 PVC EX I EX 1 1 0.74 1.32 14 2 SCH40 "PVC 2 1 1 0.42 15 3 SCH40 �PVC 4 1 1 0.70 9 VEHICLE MOVEMENT EQUIPMENT GROUND MINIMUM SIZE #8 OR EQUAL TO OR LARGER THAN THE LARGEST WIRE SIZE IN THE CONDUIT. 10 40 FLASHING YELLOW ARROW VEHICLE MOVEMENT PEDESTRIAN MOVEMENT % 0 20 60 SCALE IN FEET PRE-EMPT 19TENW Wee "O� MAR 2022 A = 02 & 05, OLC (FYA) Transportation Engineering NorthWest 0% CITY F NEW ELEMENTARY SCHOOL #16 B = 04 & 07, OLD (FYA) Transpoilaflon PlannIN I Design I Tefflc Impact & Oreiations 0 CHELAN AVE NE Project Contact: TrisvorTakam, P.E. Planning/Building/Public TRAFFIC SIGNAL PLAN C = 06 & 01, OLA (FYA) D REN N HM- 9:7 147 D = 08 11 � SE ft Street Suite 200, Bellevue, WA 98004 AL Z VAIIIIIIII7 0 RENTON, WA WM Offleo rQ5) 889,6747 NO. REVISIO 1. EEJ Works 7Dept Phone: 425-250-01165 N BY DATE APPR F: Uo"") �"�A) 121 12, z � 01 05 �J 12 12" 12 FYA m(:�) m 02 06 12 03 NOT USED z Lo VEHICLE HEADS PEDESTRIAN HEADS 07 NEW: 1 IIOLA NEW: 21,22 NEW. 28 29 511OLC 41,42 48:49 04 08 711OLD 61,62 68,69 81,82 REL: 88.89