Loading...
HomeMy WebLinkAboutR-397011to CO 0 W Q F— rlr 17 vJ J Q J r TFL — TEL 1 v 1 1:1 1 / e • EXG SSMH STA 9+63.26, 6.97R RIM = 4A.75 INV(E) = 415.1210" PVC \ 1rs0.75, 4 431.05 430.73 a MATCH EXG GRAD 430.64 MATCH EXG GRADE a 430.67 zf V ASPHALT TRANSITION o TO EXG D/W 430.13 . a MATCH EXG GRADE D 1 S/W TRANSITION C4 NTS 430 425 9+80 10+00 PROFILE AT CURB SE 164TH ST SCALE: 1 = 10' H ; 1 :2 V ( ; LOT 2 5090.08 SQ FT 0.12 ACRES Alt Am i_�..�� I • • ISO STA:l0+05 (FC777�D I�iVElj�iENTS PE & LOCATION u� �- LINE LP 12" 0 PVC SDR-35 @4464- 1 1.28% S88004'46"E . 20,1 O 12 -�- -sS - -- ._ -S STA 10 13.4k9.00 L (FC) .�S- \ —S C/L OF NEW DW STANDARD CONCRETE DRIVEWAY ENTRANCE - PER COR STD CENTERLINE OF ROW PLAN 104.1 & 104.2 EXG ROCK WALL AS BUILT EDGE OF SM UTILITY CONFLICT NOTE THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES, WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 AND THEN POTHOLING ALL EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT AP CONSULTING ENGINEERS PLLC TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. 432.28 GRADE TC ATCH LANDSCAPING TO EAST OF SIDEWALK AT EXG GRADE 0.0% GRADE FOR 1.0 FT THEN DOWNWARD AT A 7 GRADE OF 3:1 TO MATCH EXISTING GRADE, FILLING N EXISTING DITCH, RIPRAP PER TABLE 4.2.2.A F THE RSWDM (TYP) GRAVEL SHOULDER PER C7 P OHP —D — —D 11+12.11,10.37'L r OF ROAD TRANSITION 44-LF 1 TO PVC SDR-35 @�6 �4% . 434.69 MATCH EXG GRADE i 16.5 16.85% 6 H SE I ST.11' 11+00 1.1+19 \ - -� STA 10+84.96,13�O�L (FC) END OF FRONTAGE IMPROVEMENTS PER DTL 2/C4 MATCH EL-EVATION & LOCATION OF EXG IMPROVEMENTS - N W E FRONTAGE IMPROVEMENT PLAN - SE 164TH ST SCALE: 1 =10 S . e 1 w •. - • , � ------`_"- � ���/fin"'_- iI AS -BUILT REVISION AEP 06/28/2019 SURVEYED: DESIGNED: KL DRAWN: KL CHECKED: AEP BY DATE APPR APPROVED: 430 425 11AOO.02 SCALE: SCALE ��AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERnCAL: NAVD 1988 HORIZONTAL NAD 1983/1991 DATUM Lu w cc U) e1- co LIJ U) VERTICAL CURB & GUTTER PER COR STD DTL 101 AS -BUILT NOTES: 1. AS -BUILT INFORMATION ON THESE DRAWINGS IS BASED ON INFORMATION PROVIDED TO APCE BY TOUMA ENGINEERS & LAND SURVEYORS AND ANYTHING NOT SHOWN ON THESE PLANS AS HAVING BEEN CONSTRUCTED DIFFERENTLY FROM WHAT WAS SHOWN ON THE APPROVED CONSTRUCTION DRAWINGS IS UNDERSTOOD BY APCE TO HAVE BEEN BUILT PER THE APPROVED DESIGN PLANS. 2. OTHER THAN AS SHOWN AS -BUILT CHANGES TO SURFACE ELEVATIONS ARE NOT REFLECTED IN THIS PLAN. 8' LIM HMA 4" THK ASPHALT CLASS TYPE 1/2 W/6" CRUSHED ROCK BASE PROOF -ROLL EXG SUBGRADE TO CHECK FOR SOFT SPOTS. COMPACTED TO 95% MODIFIED OVER -EXCAVATE SOFT SPOTS 12" MIN AND FILL WITH BASE PROCTOR COURSE GRAVEL. COMPACT TO 95% MODIFIED PROCTOR MIN. SE 164TH FRONTAGE IMPROVEMENTS NTS CITY OF 'R RENTON Planning/Building/Public Works Dept. VARIES aCID a ��// P-4 04 (P z er m Z CV Lr-'1 co m O WW Z xu Z M ti 0 UW� E 0 U to N L1J c R-397011 IN COMPLIANCE WITH CITY OF RENTON STANDARDS LALLY'S SHORT PLAT FRONTAGE IMPROVEMENTS PLAN ri7 O O O Cfl Q TO DATE 08/03/2017 (n FlELDBOOK: BOOK PAGE PAGE DRAWING NO: C4 J < _..I SHEET: OF: 4 - 6 R-397004