HomeMy WebLinkAboutR-408548CONNECT SD TO
DETENTION TANK SYSTEM
m7
36'
CATCH BASIN
i
O O
�
PERFORATED PVC PIPE-//
S=0%
coterra
ENGINEERING PLLC
6413 Phinney Ave North
Seattle, Washington 98103
ph 206.596.7115
coterraengineering.com
PLAN 6" PERFORATED PVC PIPE-Z
S=0%
BIORETENTION PLANTER DETAIL
NTS UNLESS NOTED OTHERWISE
2 DO
RECORD DRAWINGS
REVISION
RIP RAP - 2-6" COBBLES ,--/
1' THICK X 4' X 4'
4/9/21
SURVEYED:
DESIGNED: MB
DRAWN: MB
CHECKED: PA
BY
DATE
APPR
APPROVED:
SCALE:
2
C5.9 CONCRETE WALL PER
STRUCTURAL DETAIL
8 3" ARBORIST WOOD CHIPS
5.8
$ 8 18" BIORETENTION
SOIL MIX
8 18" DRAIN ROCK
C5.8
6" PERFORATED PVC PIPE
S=0%
WATERPROOFING EXTEND
ABOVE WATER LEVEL
VEnCAL,1988
1 »=20' HORIZO TA NAD NAVD - 1983/1991
ONE INCH DATU M
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
4' 6"
1' MIN
irk 0519911 0 ►0
Im
•
BIORETENTION CELL WITH
WALLS - TYPICAL SECTION
cn
J_
0
cn
0
w
z
X
a
12"
PROVIDE LINKSEAL FOR
ALL PIPE PENTRATIONS
(2) #4 CONT. TOP
PER CIVIL
BIORETENTION MATERIALS
SEE DETAIL THIS SHEET
a
#5 @ 12" OC VERT. -
WITH STANDARD HOOKS
INTO FOOTING
#4 ® 12" OC HORIZ.
KEYWAY @ WALL/FTG.
(5) #4 CONT, TOP
& BOTTOM
I %a
6" CURB
NOTE: DETAIL PROVIDED BY SWENSON SAY
FAGET STRUCTURAL ENGINEERS
i 12"
8" 13" CLR
#4 ® 12" OC TOP &
BOT. W/ STANDARD
HOOKS EA END
PAVING PER PLAN
CENTER REINFORCING
IN WALL
FREE DRAINING
BACKFILL
MATERIALS
BIORETENTION VAULT- STRUCTURAL DETAIL
NTS
CONSTRUCTION
RECORD DRAWING
THE INFORMATION ON THIS DRAWING
INDICATES CHANGES MADE TO THE
CONSTRUCTION DOCUMENTS BASED
UPON UTILITY AS -BUILT SURVEY
PREPARED BY DAVID EVANS &
ASSOCIATES, INC., DATED 3/23/21, AND
TRANSFERRED TO THE REPRODUCIBLE
DRAWINGS BY THE ENGINEER.
0 CITY OF
RENTON
Planning/Building/Public Works Dept.
z
O
U)
W
rr
L
nW
I..r.
rr�
v!
O
n
z
O
U
rr
rr�
v!
z
O
U
J_
u
R-408548
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WILLOWCREST TOWNHOMES
EDMONDS AVE NE, RENTON, WA
CML DETAILS
7/29/19
PAGE:
DRAWING NO:
C5.9
SHEET. OF:
26 3:
CO
M
T
O
O
0)
Ir-
��
N
T
O
O
O
T
w
75
O
>z
O
W
U
O
J
J