Loading...
HomeMy WebLinkAboutzR-4052SetN 0 1 O w I— I — a 0 I- 0 J N I— Z w 2 0 w w 0 Z 0 a T O N O 1 w Cm G Z I— w w N 2 zz cc' o z W W �o OJ N N 1< LQzoo ~ I �LLJo n Z U N � x v xW EX CB RIM 263.83 INV=262.53 (12" CONC- INV=259.23 (12" CONC- \ W D SD � SD / / W o \ \ ISTA: 6+58.55 I / TAX PARCEL / 334390-2565 / 2� NOTE SW 1/4 OF SE 1/4 OF SEC. 5, TWP. 23 N., RNG. 5 E., W.M. CITY OF RENTON, STATE OF WASHINGTON 53.31-OFFSEP 20.46 L T CAS —GAS —EQ W W W W W W W W W W 1 W `Q W W W W W JY L7 \ E 14 TH S TREE T1 I 7+00 \ \ 1 8+0 Q s}� S S S S -\--s s SI s S �s S SI S Q \\LOT 5 \� TAX PARCEL 559205-2568 LINCOLN PLACE SHORT PLAT REC. NO. 2016020900007 THE SAFE PEDESTRIAN WALKWAY GOES FROM THE SITE, EAST ALONG NE 14TH STREET TO MONTEREY AVE NE THEN NORTH UP MONTEREY AVE NE TO NE 16TH STREET THEN EAST TO INTERSECTION OF EDMONDS AVE NE AT MCKNIGHT MIDDLE SCHOOL P --�— F P P/ p — STAX7+62.45 EX CB 1 RIM 274.49 INV=271.59 (12" CONC—E) o� \ W i M 0 0 Z LOT 6 TAX PARCEL 559205-2563 I, GRAPHIC SCALE 20 0 10 20 40 SAZEI DESIGN GROUP, LLC ��P�o WAS 6608 11OTH AVE. N.E. KI RKLAN D, WA. 98033 25693 TEL. (425) 212-2280 r�FG STEQ FAX. (425) 889-6887 S��NAL 10-3- LEGEND CASED MONUMENT (OCCUPIED 10/1(9) • EXISTING CORNER AS DESGRIBED &' WOOD FENCE (UNLESS OTHERWISE NOTED) ° 450.0 SPOT ELEVATION PPS POWER POLE H YD(�_ HYDRANT w M WATER VALVE w Z WATER METER PM® POWER METER ® CATCH BASIN SSMH O SANITARY SEWER MANHOLE TREES: CALIPER IN INCHES $ TYPE: • G-GEDAR, P-PINE, FR-FRUIT 12F 12FR F-FIR, UP -UNKNOWN DECIDUOUS P OVERHEAD POWER LINE CITY OF RENTON SURVEY CONTROL LOT 10 CONTROL MON 57 3" FLAT BRASS DISC WITH "X" AND A PUNCH MARK ON CONCRETE POST AT TAX PARCEL THE CONSTRUCTED INTERSECTION OF N.E. 12TH STREET AND EDMONDS AVENUE 559205-0100 NE CONTROL MON 71 TOP OF 2 1 /2" BRASS DISK SET IN CONCRETE MONUMENT 11-8 S AND 9' EAST OF THE INTERSECTION OF NE 12TH STREET AND ABERDEEN AVENUE NE SITE DATA: a. TAX PARCEL/PLAT NUMBERPROJECT : 3343902566 MONTEREY HEIGHTS b. ADDRESS(ES): 1909 NE 14TH ST RENTON, WA. 98056 VOL. 194, PIGS. 50-52 C. SITE AREA: 11,960 SF OR 0.28 ACRES d. DISTURBED AREA 11,000 SF OR 0.25 ACRES) e. GROSS IMPERVIOUS AREA 6,009 SF OR 0.14 ACRES) LOT 9 f. NET NEW IMPERVIOUS AREA 6,009 SF OR 0.14 ACRES g. IMPERVIOUS SURFACE COVERAGE BASED ON GROSS IMPERVIOUS AREA: 50.4% TAX PARCEL h. BUILDING COVERAGEBUILDING SIZES: 4,930 SF 559205-0090 i. PARKING COUNT VEHICLE: 8-TOTAL (4-DRIVEWAY AND 4-GARAGE) AND 4-BICYCLE GARAGE i. ZONING: R-8(CITY OF RENTON k. MAX BLDG NUMBER OF STORIES: 2 I. MAX WALL PLATE HEIGHT: 24' M. MAX BLDG LOT COV'G: 50% n. MAX. IMPERVIOUS SURFACE: 65% o. SETBACKS MIN FRONT SETBACK: 20' MIN REAR SETBACK: 20' MIN SIDE SETBACK: 5' .11 PIE DKI! F,I 1 ! Iti a �d lr- *:1 M . J IIIQ1L1 M4ill' ooggd - M14 1.11 n: . I_ • :I: 'I LL i ,Y 4 THE LAINVIND 0 t. - Li e = ,. I f r ,Iw 1 h5r L mAirig r r�i irIrtCtmnin 1' drox! IJvn:J ali •' WIGHL.A VICINITY MAP PARCEL NUMBER 33431 f02566 SITE ADDRESS 1909 NE 14TH ST RENTON, WA. 98056 LEGAL DESCRIPTION THE EAST 104 FEET OF THE NORTH HALF OF TRACT 268, C. D. HILLMAN'S LAKE WASHINGTON GARDEN OF EDEN DIVISION NO. 4, ACCORDING TO THE PLAT RECORDED IN VOLUME 11 OF PLATS, PAGE 82, IN KING COUNTY, WASHINGTON; EXCEPT THE SOUTH 141 FEET THEREOF; AND EXCEPT THE NORTH 20 FEET FOR ROAD UNDER RECORDING NUMBER 6660998. LOT "A" IMPERVIOUS COV'G LOT AREA: 5,980SF ROOF AREA: 2,465SF DRIVEWAYS, PATIOS & WALKS: 520SF TOTAL IMPERVIOUS AREA 2,985SF LOT "B" IMPERVIOUS COV'G LOT 8 LOT AREA: 5,980 SF ROOF AREA: 2,464SF ]. DECISION DRIVEWAYS, PATIOS & WALKS: 460SF a TOTAL IMPERVIOUS AREA 3,024SF J a The Avo n Short P lat, Fife LUA18-OW204, as dep ieted in Exh ihit 2, is a ppraved and is su bject to t he fo I Iowi ng conditions- -1- Th e app ka nt shal I ,provi de er iden ce to th a Durre nt P la nn i ng P reject Manager that the exi Sti ng si ngle- Q f3rni[V residence o n th a prope rty has bee n re moved p rior to su brrti itti ng th e f i na I short p lat docu m ent V/ for recording_ I- 21. Th e app Ii ca-nt shal l prcfvi de a joint use d riveway with a si ng le cu rb Cut Onto N E 14th St. Th e j e i nt U5e R-405201 C d riveway sha IG be s he wn on the civil Constru ction pl ans to be revf ewed and approved by th e Cu rrent LEGEND J P la nr1 i ng proj edt Man alter prior to i ssua noe of the co nstruckio n perm it. N C1 COVER SHEET IN COMPLIANCE WITH CITY OF RENTON STANDARDS 3_ The applicant shall submit a map w th the civiI construcUon permit application that identifies a safe C2 EXISTING SITE CONDITIONS I— walki ng route from th a su bj ert p ro pertV to McKn fight M idd le School and th a two bus sto ps for C3 SWWP PLAN DEVELOPMENT ENGINEERING W Ken nVda le El emr-e IntarV an d Haze n H ig h- Any safe wa I k ing ga ps ato ng the route sha I I be i m p roved by the C4 UTILITY AND GRADING PLAN jchavez 10/18/2019 k4so app IFca nt. The ma p an d any n eeded i mp revernents sh a I I be reviewed a rid a p proved by the Cu r rent C5 N E 14TH STREET PLAN � Pla nn i ng Prej ec# Man a,ger prior to issua nce of the civi I eon struct ion pe rrrLit. C 6 D ETAI LS a O C7 DETAILS REGIONAL FIRE AUTHORITY �N*o C8 NOTES APPROVED`` W L1 LANDSCAPE PLAN dhomas 10/18/2019 "°�F E'?''p 1 REVISED PER CITY REVIEW RAD 4-2-19 RAID SURVEYED: SCALE: 1 "=20� VERTICAL: NAVD 83/1 HORIZONTAL: NAD 1983/1991 • CITY O F 'R RENTON A V O N DEVELOPMENT SHORT PLAT 2 LOT DATE: 4-2-19 „I Q 7 L DESIGNED: R. DECCIO FIELDBOOK: PAGE: DRAWN: DRAWING NO: LR ONE INCH DATU M • Q CHECKED: R. DECCIO AT FULL SCALE IF NOT ONE INCH Planning/Building/Public Works Dept. R-405201 > NO. REVISION BY DATE AP P R SCALE ACCORDINGLY COVER SHEET a APPROVED: SHEET: OF: R. DECCIO 1 9 N a J CL H O U) H O J CV H Z W 2 CL O J W W 0 Z O a Q J a. O '_'A VI I- O J CV I- Z W 2/� a_ O W W io Z O Q CM O CV LO O 1 W m Z W W 2 I N s N � O X s CO N O p N 0 Qz w < co EX CB RIM 261.23 INV-260.13 (8" CONC-E) INV=259.73 (12" CONC-W) W Z W UJI Q ® EX CB RIM 263.83 INV=262.53 (12" CONC-E) INV=259.23 (12" CONC-W) \ SD 1 S�1 SD I SD �- SD S, 3 I I / W W W W W 6+1p0 I \ ISTA: 6+58.55 I SILT FENCE (SEE DETAIL SHEET 6)- TAX PARCEL 334390-2565 / i EXISTING RESI>% TO BE�RENOVE I I LIMITS OF\PISTURBANCI 1 \ 1 \ 1 \ I \� EXISTING SHED \ TO BE REMOVED \ l SW 1/4 OF SE 1/4 OF SEC. 5, TWP. 23 N., RNG. 5 E., W.M. CITY OF RENTON, STATE OF WASHINGTON W W W W - \ 3 \ \7+00 A \I N99"43"4W W 51.92I \ SLOT 5 TAX PARCEL 559205-2568 LINCOLN PLACE SHORT PLAT REC. NO. 2016020900007 SAZEI DESIGN GROUP, LLC 6608 110TH AVE. N.E. KIRKLAND, WA. 98033 TEL. (425) 212-2280 FAX. (425) 889-6887 LOT 6 TAX PARCEL \ \ 559205-2563 14TH STREET \\ s� -s S S\ I \ S ¢ S �S (SEE DETAIL SHEET 6) W 0 �30' INGRESS & UTILITY EASEMENT RC NO MONTEREY HEIGHTS 5380145 VOL. 194, PGS. 50-52 \SILT FENCE (SEE DETAIL SHEET 6) LUI J TAX PARCEL 559205-0090 i r- 10-3-19 LIMITS OF DISTURBANCE LOT 8 TAX PARCEL 559205-0080 LEGEND GASED MONUMENT (OGGUPIED 10/16) • EXISTING GORNER AS DESGRIBED 6WOOD FENCE (UNLESS OTHERWISE NOTED) SPOT ELEVATION PP POWER POLE H YD6_ HYDRANT WV WATER VALVE W ® WATER METER PM POWER METER CB GATGH BASIN SSMH O SANITARY SEWER MANHOLE TREES: GALIPER IN INGHE5 TYPE: G-GEDAR, P-PINE, FR-FRUIT 12F 12FR F-FIR, UD-UNKNOWN DEGIDUOU5 P OVERHEAD POWER LINE GRAPHIC SCALE 20 0 10 20 40 w z J r Of w D- 0 O- D- �'� 2' MIN I << �9 �P+ EXISTING GROUND GRADING SLOPE SET BACK (TYP) N TS CALL 2 BUSINESS DAYS BEFORE YOU DIG 1-811-424-555 REVISED PER CITY REVIEW RAD 4-2-11 RAD SURVEYED: REVISED PER CITY REVIEW RAD 4-8-1V RAD DESIGNED: R. DECCIO DRAWN: LR CHECKED: R. DECCIO NO. REVISION BY DATE APPR APPROVED: R. DECCIO SCALE: VERTICAL: NAVD 1988 • HORIZONTAL: NAD 1983/1991 1 "=20' DATU M ONE INCH AT FULL SCALE Planning/ IF NOT ONE INCH SCALE ACCORDINGLY CONSTRUCTION SEQUENCE EROSION AND SEDIMENT CONTROL RECOMMENDED CONSTRUCTION SEQUENCE 1. PRE -CONSTRUCTION MEETING. 2. POST SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR (MAY BE CONSOLIDATED WITH THE REQUIRED NOTICE OF CONSTRUCTION SIGN). 3. FLAG OR FENCE CLEARING LIMITS. 4. INSTALL CATCH BASIN PROTECTION IF REQUIRED. 5. GRADE AND INSTALL CONSTRUCTION ENTRANCE(S). 6. INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.). 7. CONSTRUCT SEDIMENT PONDS AND TRAPS. 8. GRADE AND STABILIZE CONSTRUCTION ROADS. 9. CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.) SIMULTANEOUSLY WITH CLEARING AND GRADING FOR PROJECT DEVELOPMENT. 10. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL AND MANUFACTURER'S RECOMMENDATIONS. 11. RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY'S EROSION AND SEDIMENT CONTROL STANDARDS. 12. COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAYS DURING THE WET SEASON WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING OR EQUIVALENT. 13. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN SEVEN DAYS. 14. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. 15. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BMPS REMOVED IF APPROPRIATE. THE 13 ELEMENTS OF A CONSTRUCTION SWPPP 1. Preserve Vegetation/Mark Clearing Limits: The clearing limits are indicated on the plan sheet. Furthermore, clearing and grading will be limited to only areas that need to be disturbed for grading/construction of the site and frontage improvements. Construction will require regarding the entire site. Field marking the clearing limits shall be completed prior to clearing and grading activities. BMP's: Preserve Natural Vegetation (VEG) 2. Establish Construction Access: Access to the construction site shall be limited to the rock construction entrance. The rock construction entrance shall be installed off of the Street to provide access to the construction vehicle/equipment staging and employee parking areas. BMP's: Rock construction entrance (CE) See detail sheet C9 3. Control of Flow Rates: Storm water detention: No detention is proposed for the site since the work should be completed in a short period of time. BMP's None Proposed 4. Installation of Sediment Controls: Sediment control will be provided through a combination of filtration through the surround on -site vegetation, or filter fence if required. , BMP's: Silt Fence (SF) Sediment Trap (ST) I 5. Soils Stabilization: Temporary and permanent soil stabilization will be provided. Temporary stabilization will be provided through the application of straw and/or plastic sheeting to exposed, worked earth. From October 1 until April 30, no exposed soil may remain exposed and unworked for more than two days; after May 1, no exposed soil may remain exposed and unworked for more than seven days. BMP's: Straw Covering, Plastic Sheeting, Final Landscaping(as required) 6. Slope Protection: Stock piles shall be protected from erosion through cover and prevention of concentrated surface runoff flows on steep slopes as required. BMP's: Plastic Sheeting, (AS REQUIRED) 7. Protection of Permanent Drain Inlets: Inlet protection will be provided for all catch basins. BMP's: Inlet Protection (IP) See detail sheet (AS REQUIRED) 8. Stabilization of Channels and Outlets: All channel slopes shall be constructed and protected against erosion in accordance with County code. (None Required) 9. Pollutant Control: Pollutants shall be controlled through the on -site BMP's proposed above. 10. Dewatering Control: De -watering: Interception of the water table is expected to occur. (NOT REQUIRED) 11. BMP Maintenance: All BMP's and SWPPP elements shall be inspected daily and maintained as required. 12. Project Management: The project shall be managed in a cooperative effort by the project manager, contractor, engineer, and the county inspector. During the construction process, if unforeseen issues arise that cannot be resolved on site, construction activity (other than SWPPP maintenance) shall be halted and the owner's representative and the project engineer are to be contacted and informed of the situation. TBD 13. Protect on -site stormwater management bmps for runoff from roofs and other hard surface on -site stormwater management bmps used for runoff from roofs and other hard surfaces include: full dispersion, roof downspout full infiltration or dispersion systems, perforated stubout connections, rain gardens, bioretention systems, permeable pavement, sheetflow dispersion, and concentrated flow dispersion. the areas on the site to be used for these bmps shall be protected from siltation and compaction during construction by sequencing the construction in a fashion to install these bmps at the latterpart of the construction grading Q operations, by excluding equipment from the mps and the associated areas, and by using the J erosion and sedimentation control bmps listed below. relevant bmp's bmp c 102: buffer zone NOTE: H CLEARING LIMITS AND SILT FENCE TO BE SET JUST INSIDE OF THE PROPERTY LINES. O TOPSOIL: STOCKPILE EXISTING TOPSOIL DURNING GRADING AND REPLACE IT PRIOR TO PLANTING PER BMP 15.13 OPTION 3. TOPSOIL REQUIRED 500 CYDS /_ V / H O R-405203 J IN COMPLIANCE WITH CITY OF RENTON STANDARDS I CM H EDEVELOPMENT ENGINEERING Z ez 10/18/2019 W O J W DATE: CITY OF AVON DEVELOPMENT 2 LOT 4-8-19 W SHORT PLAT FIELDBOOK: RENTON PAGE: Z DRAWING NO: O uilding/Public Works Dept. R-405203 > S W W P PLAN SHEET: 3 OF: 9 U EX CB N RIM 263.83 U) INV=262.53 (12" CONC—E) O INV=259.23 (12" CONC—W; O � \ N 0 \ w X CB3 \ IE INTO EX B \\ ITH NEW 12 PIPE \ H J LL _w - W iW W W- 1✓ W W O I I \\ A4 2 3 A CD I \ H I 3 \ O I \, J ` 3 CV L � 3 r \ s sus Z W 2 \ m CD 3 1\ O \ J CB #1 TYPE 1 \ W _ STA 6+60 13FT` �T > RIM 264.5 f \ W IE=261.50 (12' HDPE NW) 0 IE=262.00 (8"HDP� S) I T 6+58.55 Z 1 \O 17 LF 8" HDPE S=16.46 % Q YARD DRAIN / RIM 265.9 / IE=263.30 6"HD7�E E O IE = 263.10 8 HDPE N LO TAX PARCEL / 0 334390-2565 1 DC ` w EX� T,.INO RESIDENGE m TO E3E`O\lD Z H W 2 0 N aci Q� w O I I_ �O ♦_ J CJ X CONDITION OF APPROVAL: CDF SHALL BE USED FOR BACKFILL IF MINIMUM PIPE COVER REQUIREMENT CANNOT BE MET. INSTALL 5" STORZ ADAPTER ON EXISTING FIRE HYDRANT PUMPER PORT STA: 6+53.31OFFSET: 20.46 L EX CB 2 INSTALL NEW CB TYPE 1 RIM 263.83 1 TIE INTO EXIST CB WITH NEW 12" PIPE SD SD I VERIFY INVERTS PRIOR TO CONSTRUCTION \ 1 AND GROUT PIPE I -W -W -W �\ W W- w W w �W \ I \ \ 3 \ \ 3 \ I I \7+00 STA: �+10.50 16' CONC\PRIVEWAY s s s s s s s s s �s ` s s S s W W W W W W W \ W W W W W( W W ICE 14 TH TREE T \ \ \ 8+ s� s s s \s s s s s s\ s ' HE —USE I ° °� ° 0 5E R MO\/ED \ EXIST WM I WM m 5' CONC S-WALK ° I ° a'6 LOT "B" a I zi 0% CID \ a N I &5_ LF HDPE S=3. ° w N 10' ®AINAG _AC _TILITY ASEMENT -� N \\ — — --RIM-2 -&-.0DRA xi I `�� I N IE=265.5 6"HD!PE \ Ld a �O' ° \ ° I 2 555L 555L \ 6 I FIQONNE�TIONI (SEE DETAIL SHEET 7) MNATA,IN 51�T SEPARATION FROM PROPERTY I11NE AND BUILDING (TYP) TO BE SIZIED AND LOCATED AT TIME O�FI RESIDENTIAL PERMIT APPLICATION EX. HOUSE m TAX PARCEL 334390-2566 u, � \ I \ \ I \ � I \ \ I \ 1 \ \ 1 \ I 1 \ \ 1 \ II 1 \ I 1 \ i L — — — - 1 \ II 1 \. I \ I EXISTING SHED I \\ � SH TO 5E REMO\/EDI \ \ 68 _ I � I \ — r-yn SAZEI DESIGN GROUP, LLC 6608 110TH AVE. N. E. KIRKLAND, WA. 98033 TEL. (425) 212-2280 FAX. (425) 889-6887 I I \ 20' S55L I 20' 555L v N0. LOT, REVISION ° 1 STA+62.45 \ \ EX CB _ \ RIM 274.49 INV=271.59 (12' REMOVE CURB AND SIDEWALK AT NEAqE-ST-,JOINT AND MATCH CUR LINE. 0 4-2-14 RAD SURVEYED: DESIGNED: R. DECCIO DRAWN: LR CHECKED: R. DECCIO B Y DATE AP P R APPROVED: R. DECCIO SCALE: 1 "= 20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY SW 1 /4 OF SE 1 /4 OF SEC. 5, TWP. 23 N., RNG. 5 E., W.M. CITY OF RENTON, STATE OF WASHINGTON GRAPHIC SCALE 10 0 5 10 20 LEGEND GASED MONUMENT (OGGUPIED 10/I(b) • EXISTING CORNER AS DE5GRIBED 6 WOOD FENGE (UNLESS OTHERWISE NOTED) � 450.0 SPOT ELEVATION P o POWER POLE HYD6_ HYDRANT w A WATER VALVE w ® WATER METER PM® POWER METER ® GATGH BASIN SSMH O SANITARY SEWER MANHOLE TREES: CALIPER IN INGHES TYPE: • G-GEDAR, P-PINE, FR-FRUIT 12F 12FR F-FIR, UD-UNKNOWN DEGIDUOUS P OVERHEAD POWER LINE VERTICAL: NAVD 1988 • HORIZONTAL: NAD 1983/1991 CITY OF V%01R] RENTON DATU M • Planning/Building/Public Works Dept. R-405204 ia3 IN COMPLIANCE WITH CITY OF RENTON STANDARDS H DEVELOPMENT ENGINEERING Z jchavez 01 /08/2020 w I 1 0 AVON DEVELOPMENT 2 LOT SHORT PLAT UTILITY AND GRADING LL O W DATE: W 4-8-19 FIELDBOOK: PAGE: DRAWING N0: O 0 R-40520 4 SHEET: 4 OF: 9 R Q J H O 2 H O J N 6 N Ln O 1 O 1 W J O V/ O J N I- Z 5W CL O J W > W 10 Z O > Q Lu O J I N cco W Q � I OL C O _J W I � � N N Z c aL1 1 � X o O x 0_ a X BMP TS.13 Post -Construction Soil Quality and Depth Purpose and Definition Naturally occurring (undisturbed) soil and vegetation provide important stormwater functions including: water infiltration; nutrient, sediment, and pollutant adsorption; sediment and pollutant biofiltrotion; water interflow storage and transmission; and pollutant decomposition. These functions are largely lost when development strips away native soil and vegetation and replaces it with minimal topsoil and sod. Not only are these important stormwater functions lost, but such landscapes themselves become pollution- generating pervious surfaces due to increased use of pesticides, fertilizers and other landscaping and household/industrial chemicals, the concentration of pet wastes, and pollutants that accompany roadside litter. Establishing soil quality and depth regains greater stormwater functions in the post development landscape, provides increased treatment of pollutants and sediments that result from development and habitation, and minimizes the need for some landscaping chemicals, thus reducing pollution through prevention. Applications and Limitations Establishing a minimum soil quality and depth is not the some as preservation of naturally occurring soil and vegetation. However, establishing a minimum soil quality and depth will provide improved on -site management of stormwater flow and water quality. Soil organic matter can be attained through numerous materials such as compost, composted woody material, biosolids, and forest product residuals. It is important that the materials used to meet the soil quality and depth BMP be appropriate and beneficial to the plant cover to be established. Likewise, it is important that imported topsoils improve soil conditions and do not have on excessive percent of clay fines. Design Guidelines 251658240 Soil retention. The duff layer and native topsoil should be retained in an undisturbed state to the maximum extent practicable. In any areas requiring grading remove and stockpile the duff layer and topsoil on site in a designated, controlled area, not adjacent to public resources and critical areas, to be reapplied to other portions of the site where feasible. 251658240 Soil quality All areas subject to clearing and grading that have not been covered by impervious surface, incorporated into a drainage facility or engineered as structural fill or slope shall, at project completion, demonstrate the following: I. A topsoil layer with a minimum organic matter content of ten percent or weight in planting beds, and 5% organic matter content (based on a loss -on -ignition test) in turf areas, and a pH from 6.0 to 8.0 or matching the pH of the original undisturbed soil. The topsoil layer shall have a minimum depth of eight inches except where tree roots limit the depth of incorporation of amendments needed to meet the criteria. Subsoils below the topsoil layer should be scarified at least 4 inches with some incorporation of the upper material to avoid stratified layers, where feasible. 2. Planting beds must be mulched with 2 inches of organic material Quality of compost and other materials used to meet the organic content requirements: The organic content for -pre-approved" amendment rates can be met only using compost that meets the definition of -composted materials" in WAC 173-350-220. This code is available online at: <http://www.ecy.wo.govlprogromslswfolfocilitiesl350.html> Compost used in bioretention areas should be stable, mature and derived from yard debris, wood waste, or other organic materials that meet the intent of the organic soil amendment specification. Biosolids and manure composts can be higher in bio-available phosphorus than compost derived from yard or plant waste and therefore are not allowed in bioretention areas due to the possibility of exporting bio-available phosphorus in e ffl u en t. The compost must also have an organic matter content of 35% to 657., and a carbon to nitrogen ratio below 25:1. The carbon to nitrogen ratio may be as high as 35:1 for plantings composed entirely of plants native to the Puget Sound Lowlands region. Calculated amendment rates may be met through use of composted materials as defined above; or other organic materials amended to meet the carbon to nitrogen ratio requirements, and meeting the contaminant standards of Grade A Compost. The resulting soil should be conducive to the type of vegetation to be established. 251658240 Implementation Options: The soil quality design guidelines listed above can be met by using one of the methods listed below. I.Leave undisturbed native vegetation and soil, and protect from compaction during construction. Amend disturbed soil according to the following procedures: Scarify subsoil to a depth of one foot In planting beds, place three inches of compost and till in to an eight -inch dep th. In turf areas, place two inches of compost and till in to an eight -inch dep th. Apply two to four inches of arborist wood chip, coarse bark mulch, or compost mulch to planting beds after final planting. Alternatively, disturbed soil can be amended on a site -customized manner so that it meets the soil quality criteria set forth above, as determined by a licensed engineer, geologist, landscape architect, or other person as approved by Snohomish County. Stockpile existing topsoil during grading, and replace it prior to planting. Stockpiled topsoil must be amended if needed to meet the organic matter and depth requirements by following the procedures in method (2) above). Import topsoil mix of sufficient organic content and depth to meet the organic matter and depth requirements. More than one method may be used on different portions of the some site. Soil that already meets the depth and organic matter quality standards, and is not compacted, does not need to be amended. Maintenance 251658240 Soil quality and depth should be established toward the end of construction and once established, should be protected from compaction, such as from large machinery use, and from erosion. 251658240 Soil should be planted and mulched after installation. 251658240 Plant debris or its equivalent should be left on the two soil surface to replenish organic matter. DocuSign Envelope 10:6EECF5B6-602A-4E4A-B436-A317AA638878 PRIVATE ROOF DRAIN COLLECTOR PIPE: LOT LINE. TYP 6' DIA MAD., S• CIA MIN ROOF 5' MIN. CATCH BASIN PRIVATE TYPE 0.556 MIN. SLOPE. STUB WITH CLFANOUT OUT ( (TYP.) �,P, 2 FT MIN. COVER HOUSE(TYP.I I I I 3' MIN. • PRIVATE JOINT SD SD SD SD UTILITY EASEMENT CURB, SIDEWALK CITY STORM DRAIN (SO) SYSTEM S'MIN. WIDTH R.O.W. LINE PRIVATE STORM DRAIN (SD) SYSTEM, B' MIN, DIA. PIPE, SEE NOTE 1 ROOF DRAIN TO CONNECT INTO CITY CATCH BASIN ICB} MIN, SIZE TYPE 1 CLEANOUT, TYP AT EVERY W. OR 2ND 45' BEND, AND AT 100' MAX SPACING ON STRAIGHT SECTIONS NOTES: 1. SEE STD- PLANS 4M.00 AND 220.E0 FOR PIPE MATERIALS AND MINIMUM COVER REOU IREMENTS. 2. THE ROOF AND FOOTING DRAIN SYSTEMS ARE PRIVATELY MAINTAINED- S. FLOW PATTERN SHOULD BE TO THE NEAREST CO IF GRADE ALLOWS, OR TD THE NEXT DOWNSTREAM CB 4. ROOF DRAIN COLLECTORS MUST BE ANALYZED FOR CAPACITY. SIZED FOR 25-YEAR PEAK FLOW. 5. PVC PIPE MUST BE SOR 35OR THICKER AND MEET THE REQUIREMENTS OF ASTM D3034, S. PVC PIPE USED IN PRIVATELY MAINTAINED DRAINAGE SYSTEMS MUST BE WHITE IN COLOR, 7- SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NI] STD. PLAN - 225.00 PUBLIC WORKS TYPICAL PRIVATE STORM DRAIN PPR D: DEPARTMENT COLLECTION SYSTEM GAZ 9/28/2018 i :45 A DATE DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL ESC) PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT, THE APPLICANT OR OWNER. HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS. THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES 1 BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS. A PREICONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANTS CONTRACTOR. 2. THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT. 3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4 THE BOUNDARIES OF THE CLEARING LIMITS. SENSITIVE AREAS AND THEIR BUFFERS. AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OI RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANVESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REWIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT IF SEDIMENT IS TRACKED OFFSITE. PUBLIC ROADS SHAL I BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER. AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. 6. WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF -SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND. OR TO STORM DRAINS OR OPEN DITCHES. ON -SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUTAREAS. 7. ALL REQUIRED ESC BLIPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING ANDIOR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING ANDIOR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON. -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION MAINTENANCE, REPLACEMENT. ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. 8. ANY HAZARDOUS MATERIALS OR LCUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY, 9. THE ESC BAPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE, DURING THE COURSE OF CONSTRUCTION. IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED. TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 10, APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN. SIZE NOR LOCATION OF PIPES. RESTRICTORS, CHANNELS, OR STORMWATER FACILITIES. 11, ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12, ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS. THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST THROUGH APRIL 30TH) OR SEVEN DAYS WRING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING. MULCHING. PLASTIC COVERING. ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. 13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND AP RIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY 14 ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. 15, THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY. 16 BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216-30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN SDO FEET OF A DISTURBED OR CONSTRUCTION AREA. UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17 AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED V3 OF THE CAPACITY OF THE CATCH BASIN SUMP ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM 18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE ROUGH GRADED $0 THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. 19, AREAS DESIGNATED ON THE PLANI CONTAINING EXISTING STORMWATER FACILITIES OR ON -SITE BMPS (AMENDED SOILS. BCRETENTION, PERMEABLE PAVEMENT, ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION. 20 PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR RENEW. 21, PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVING THE PROJECT SITE, ALL ESC BAPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON -SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM, DISTURHOBED AREAS SHILL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST 22. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE PITS) STD. PLAN - 268.00 •m PUBLIC WORKS EROSION AND SEDIMENT CONTROL PR D DEPARTMENT STANDARD PLAN NOTES GAZ 9/zs/zols I :45 A MKNrf.Mmw.wDATL SAZEI DESIGN GROUP, LLC 6608 110TH AVE. N.E. KIRKLAND, WA. 98033 TEL. (425) 212-2280 FAX. (425) 889-6887 10-3-19 1 1 NO. REVISION DocuSign Envelope 10i 6EEC F5B6-602A-4E4A-B436-A317AA638878 4DrD 10 R = 25' MIN. INSTA LL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT- AS PER CITY ROAD STANDARDS V-S' QUARRY SPALLS GEDTI ILE 12' MIN. THICKNESS 1, DRIVEWAYS SHALL BE PAVED TO THE EDGE OF THE RIGHT-OF-WAY PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCE TC AVOID DAMAGING OF THE ROADWAY. 2. IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD 15' MIN. PROVIDE FULL WIDTH OF 1 NGRESSIEGR ESS AREA NOTES: 1. CONDITION OF USE 1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1.000 FEET OF THE SITE. 12. FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVISION ENTRANCE. STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTHAMDTH TO PROVIDE VEHICLE ACCESSIPARKING, BASED ON LOT SIZE)CONFIGURATION. 2. DESIGN AND INSTALLATION SPECIFICATIONS 21 A SEPARATION GEOTEXTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTFYTC F SHALL MEET THE FOLLOWING STANDARDS: GRAB TENSILE STRENGTH (ASTM D4632) 200 LBS. MIN, GRAB TENSILE ELONGATION (ASTM D4632) 3C% MAX. (WOVEN) CSR PUNCTURE STRENGTH IASTM D6NI1 495 LBS. MIN. ADS (ASTM D4751) 2045IU.S- STANDARD SIEVE SIZE) 2.2, OD NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE PH LEVELS IN 57ORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE 4S PROHIBITED. 2.3. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH OVARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT. 2A- FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE. $.5. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SU3STANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. 3. MAINTENANCE STANDARDS 3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE W4T14 THE SPECIFICATIONS. 3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE 9TREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING. AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE. OR THE INSTALLATION OF A WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND 3.3- ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING- THE SEDIMENT COLLECTED BY SWEEPING SHALL 13E REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECYNE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT 15 NECESSARY TO WASH THE STREETS, A STALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS- 3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAC) AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.S- IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCEIS), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. llNUSS OTHERWISE NOTED, DRAWING I$ NOT TO SCALE IN is) STD. PLAN - 215.10 PUBLIC WORKS PPROVED: DEPARTMENT STABILIZED CONSTRUCTION ENTRANCE GAZ 9/28/2018 1 DATE DocuSign DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 s LIAx. DRAINAGE GRATE TRIM GRATE FRAME _ C- OVERFLOW BYPASS T BELOW INLET GRATE DEVICE SEDIMENT AND OESRIS b FII IFRFD WATFIR SECTION VIEW DRAINAGE GRATE (RECTANGULAR GRATE SHOWN) RETRIEVAL SYSTEM (TYP.I Q 'I OVERFLOW BYPASS (TY R) BELOW INLET GRATE DEVICE ISOMETRIC VIEW NOTES: F. PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP Z. INLE7 PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE. 5. THE BIGO SHALL HAVE ABUILT-W HIGHF LOW RELIEF SYSTEM {OVERFLOW BYPASS). 6. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7, PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY UNLESS OTHERWISE NOTED, ORAWING IS NOT TO SCALE (NT5) STD. PLAN - 216.30 PUBLIC WORKS APPR O: DEPARTMENT CATCH BASIN INSERT GAZ 9/28/2018 wwAae�„�•aw DATE ID 4-2-11 RAD SURVEYED: DESIGNED: R. DECCIO DRAWN: LR CHECKED: R. DECCIO BY DATE APPR APPROVED: R. DECCIO SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY :45 ;,.1 :4'5 A VERTICAL: NAVD 1988 - HORIZONTAL: NAD 1983/1991 PRI DATU M Planning/ DocuSign Envelope ID: GEECF5B6-602A-4E4A-B436-A317AA638878 Z.2' 14GAUGE WIRE.OR EOUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC --I-iL-�---------- I - 6' MAX. PCSTSPACING MAY BE INCREASE I 4yµ• MIN. TRENCH ' IF 708WIRE BACKING IS USED ILLLJJJI BACKFILL TRENCH WITH NATIVE SOIL OR 3N4' TQ 1-Irr WASHED GRAVEL 2*04' WOOD POSTS, STEEL FENCE POSTS. OR EQUIVALENTLTYR. T MIN IxMIN` 1 I-1L_J NOTES: L CONDITIONS DF USE 1 1. SILT FENCE MAY BE USED DOWN SLOPE OF ALL DISTURBED AREAS. 1I SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST Be. CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND, 2. DII ILTH AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MUST MEET T14E STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. AOS (ASTM D4761) 301-100 SIEVE SIZE (0.60-O.i5nnnl FOR SILT FILM 50,100 SIEVE SIZE (0,304.15-1 FOR OTHER FABRICS WATER PERMITTIVITY (ASTM D4491) G.02 SEC'' MINIMUM GRAB TENSILE STRENGTH (ASTM D4632] 180 LES MIN. FOR EXTRA STRENGTH FABRIC lM LDS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM D4832) 3D%MI (WOVEN) ULTRAVIOLET RESISTANCE (ASTM 04355) 70%MIN, 22. STANDARD STRENGTH FABRIC REQUIRES WIRE BAMNG TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEER THAN 2H,1V 2A. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4•X4• TRENCH MAY BE REDUCED AS LONG AS THE BOTTOMS INCHES OF THE SILT FENCE FABRIC IS WELL SU RIE13 AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 2.S. FILTER FABRIC FENCES SHALL BE INSTAI.I,ED ALONG CONTOURS WHENEVER PCSSIBLE. i MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMECIATELY. 3,2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3, IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR 51GNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNEL IZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS. REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT. 3A. SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 61NCHES HIGH. 3-5- IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERK)RATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. UN I ESS OTHERW ISO NOTE D, PRA W ING 15 NOT TO SCALE [NISI STD. PLAN - 214.00 GAZ PUBLIC WOURRKS SILT FENCE 912812018 i DEPARTMENT DATE vitalTM Cluster Box Unit - Type I 30117 �► I-�- 1 �' 45" FRONT VIEW SIDE VIEW :45 ,I 33 318" 61 112•• 1 r' 28112' PEDESTAL 1a 1r PEDESTAL BASE BOLT PATTERN N OTES: 1. This unit is approved for LISPS and private applications. IrlooLrTser Vital CLUSTER BOX 11NCf 2. Decorative mailbox accessories sold separately and are LISPS Approved products. DOOR CHART POOR 1TPE rllNlNNOX OIRGRX1YpTN] 3. Pedestal should be Installed with Included Rudder Pad: MDDa 157H wv A mounting hardware not included. refer to installation manual for AF 1;. y� �E NONE - Ev , reaommendativns. man cam 9r7w�'i� 4. Florence "P'series CBU is Officially Licensed by LISPS: 5935 Corporate Drive r MC1nhcitlan, KS 66503 DRAvnNpa GNGMeEx xuwNer Llcense#CDSEQ-08-B-0012 wMAA Aorencemailboxes-corn ■ (800) 275-1747 1$70-BC$ AFD A GIBRALTAR INDUSTRIES COMPANY CITY OF RENTON uilding/Public Works Dept. R-405206 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING 40W jchavez 10/18/2019 AVON DEVELOPMENT 2 LOT SHORT PLAT DATE: 4-2-19 PAGE: R-405206 SHEET: 6 OF: 9 I- a. O I- O J CV I- Z W 2 a_ O WW W 10 Z \O Q LLJ h p N O � W Q 3 r- 1 1 EX, SEWER MAIN I PROPERTY LINE ENGTH AS NEEDED) 3 � I o 3'-0' I WER S1UBE ;;�' FUTURE 4" SIDE SEWER F'---SEII-R \` 2"x 4" STUD MARKING POST PAINTED -CC I AIN TEE X 6" I 5- CAP J WHITE WITH THE WORD 'SEWER" STENCILED ' IN 3" HIGH BLACK LETTERS AND #5 WIRE Z I WRAPPED AROUND THE STUD AND ' EXTENDED TO THE TOP OF THE STUD. COUPLING (IYP.) < I k �.J ; G'X6'X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER (EAST JORDAN IRON WORKS PRODUCT NO. 00367502 OR : APPROVED EQUAL, SPECIFY "SEWER- ON LID). (SEE STD. PLAN 403.1 FOR INSTALLATION) I ------------ r--------- �"J r JM EAGLE THREADED CLEAN -OUT ADAPTER HUB L -J BEND AS & PLUG (OR APPROVED EQUAL) REQUIRED EXISTING SANITARY _2 / SEWER MAIN---2.0x MIN. SLOP \ `- FUTURE 4' SIDE SEWER �6" SEWER STUB 6'X6"X6' WYE"IIFUTURE 6"K 4" REDUCER SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEDURES FOR SjnF SEWER CONNECTIONS TO EXISTING SEWER MAIN A. VITRIFIED CLAY MAIN - CUT IN A NEW PVC 'TEE" USING "STRONG -BACK' FLEXIBLE COUPUNGS (FERNCO OR APPROVED EQUAL). B. CONCRETE MAIN - CUT IN A NEW PVC 'TEE' USING "STRONG -BACK' FLEXIBLE COUPUNGS (FERNCO OR APPROVED EQUAL). C. PVC & C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL). D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED. / Cat 3000 PS MIX P/ehVN G NCRETE BLOCKING q5 ���•� 91- M '15 [Aa'- __�_____2x MIN S40PE HORIZONTAL 6" TEE 6" MIN. SEWER SEWER MAIN MAIN CONCRETE 131 OCKING ANGLE SIDE SEWER OF TEE AT MAIN BETWEEN 25* AND 45' TYPICAL NBC 1�; UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY UNE OR 3-5- LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. STANDARD SIDE SEWER STD. PLAN -406.1 APPR VED. PUBLIC WORKS URDEPARTMENT INSTALLATION O (SEWER MAIN TO PROPERTY LINE) LANE LINE VARIES: 4.5' MIN. MARKING S7AWCUT AFTER BACKFILL DEPTH OF EXISTING PAVEMENT 2" - 6" HMA E OF PAVEMENT, EDGE (SEE NOTE 2) 1' 1' OF CURB & GUTTER, OR MIN. MIN. CENTER OF LANE MARKING 2" HMA (SEE NOTE 2) 6' CRUSHED SURFACING TOP COURSE (CSTC) (9--03.9(3)) PER WSDOT STANDARD 2" SAWCUT AND REMOVE SPEOFCATIONS, COMPACTED TO 95% OR PLANE, SEAL WITH MODIFIED PROCTOR AR-4000W CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03-19), GRAVEL BORROW (9-03-14(1)) PER WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEEF BASED ON GEOTECH REPORT, COMPACTED TO WIDTH OF TRENCH AS REQUIRED BY SIZE OF 95% MODIFIED PROCTOR, PROPOSED IMPROVEMENT (SEE WSDOT STANDARD SPECIFICATION 2-09.4) PLUS AN PIPE ZONE BEDDING MATERIAL AND COMPACTION AS ALLOWANCE FOR ANY SHORING. SHORING, IF REQUIRED BY THE WSDOT STANDARD SPECIFICATIONS NEEDED, SHALL MEET THE REQUIREMENTS OF FOR THE TYPE OF IMPROVEMENT INSTALLED, EXCEPT: WSOOT STANDARD SPECIFICATION 7-08.3(1)8 F� 4 FOR STORM AND WATER PIPE, PER STD PLAN 220.0 ' FOR SANITARY SEWER, PER STD PLAN 405 TRENCH WIDTH * FOR JOINT UTILITY TRENCH, SAND WITH 95% PASSING A #4 SIEVE AND LESS THAN 5% PASSING A #200 SIEVE NOTES: 1. WHEN EXISTING PAVEMENT IN A LANE REQUIRING A FULL WIDTH REPLACEMENT IS BROKEN OR DETERIORATED TO A A F' VEMENT CONDITION INDEX 7 R ❑ DE RATING OF 0 0 LESS, THE EXISTING PAVEMENT IN THAT LANE, AND FOR THAT DISTANCE SO CLASSIFTED, SHALL BE REMOVED AND REPLACED WITH HMA MATCHING THE DEPTH USED IN THE EXISTING STREET OR THE DEPTH PER CITY STANDARD, WHICHEVER IS GREATER. 2- PRINCIPAL/ MINOR/COLLECTOR, ARTERIAL, & INDUSTRIAL ACCESS STREETS - MATERIAL AND THICKNESS SHALL BE HMA CL �" PG 64-22 AND MATCH EXISTING THICKNESS AND IN NO CASE LESS THAN 6". RESIDENTIAL ACCESS STREETS -- HMA CL 4" PG 64-22. THE THICKNESS SHALL BE THAT OF THE EXISTING PAVEMENT SECTION AND IN NO CASE LESS THAN 4". 3. WHEN THE "SAWCUT AFTER BACKFILL" ENCROACHES INTO AN ADJACENT LANE, CURB & GUTTER OR SHOULDER, THE AFFECTED LANE SHALL BE PLANED AND OVERLAID WITH HMA FULL WIDTH, THE CURB & GUTTER SHALL BE REMOVED AND REPLACED, OR THE SHOULDER SHALL BE PLANED OR REMOVED AND OVERLAID WITH HMA. 4. IF TRENCH UNDERMINES EXISTING SIDEWALK AND/OR CURBS, THEN THE SIDEWALK AND/OR CURB SHALL BE REPLACED FROM EXPANSION JOINT TO EXPANSION JOINT. 5, IF TRENCHING THROUGH EXISTING DRIVEWAY OR SIDEWALK RAMP, THE DRIVEWAY OR SIDEWALK RAMP SHALL BE REPLACED TO MEET ADA STANDARDS. TYPICAL LONGITUDINAL PATCH STD" PLAN - 110.1 PUBLIC WORKS FOR FLEXIBLEI' 0 PAVEMENT OR I 'RIPVED DEPARTMENT RIGID PAVEMENT WITH OVERLAY I* SAZEI DESIGN GROUP, LLC 6608 110TH AVE. N.E. KIRKLAND, WA. 98033 TEL. (425) 212-2280 FAX. (425) 889-6887 e' RAISED EDGE DETAIL W Tez EXTEND SIDEWALK TRAIMVISE r-C' T - r ,n. 11R4 R J011017TS TO INCLUDE RASED EDGE RUT,' DING r .11M It ytyaN • • SEE Ill DI IDLE Y • 7 SIDEWALK DETIVL - TRIL'J K7tPr SL l ATN 1711N1R (TYPI ! : 15% , FOR CURDD[ �, ► - Sff STD PLAN 101 !01 i BRIDGE OR PEDESTRAN RAILING Bulnir4 -�[[ CONTRACT FLANS -- 1.tRTKiAL WALL SEE M. NL F S IN• (%) R (TYP.1 1 I � 1 LTYPIGIL u: SIDCNALx WITH RAISED EDGE .FOR CURB DCTAR$ SE E STO PL IN 101 �JCST111G ROADIYAV : ' CRUSHE D ROCK SASI LED SlAtFACINO TOP COURSE 1CSTC1 I IO 95% VO].FIEO N4,h IC4 4I? OVRELffIrt WAAtD6Y EERI TYMM VIER AL CURS R A SIDEwAUL CFTC UNDER S OUT12A TO BE 6-TNICKNESS 09 I DDSTING R000WAY CRUSICD ROCK V"CH EVER IS GREATER VYP IOR IRE & OJrfou S FI WISHED GRADE R•AN18EL.Uv tr TOP OF CONCA&W &IJRFALE ADJACENT TO CURB r-r 1. 0' 161,11 ROU am t/l(60R Rwl FOR WRELIETAII 1 y IDY. SEE srD n.AN P. L 5 FOG CURB DETAILS ADJACENT TO CURE SWEWALX SEE STO PLAN ICI (STEEPFILL St D�£SI ALL OR I11L41TER 6tl R O"W I SIDEWALK 17 IG R 3.11- PW PRELROLDED - -' JOLYT FILLER ADJACENT TO CURB AND RAIUNG OR WALL DEO JO,M FILLER! BUtFOi arRIP SIDEWALK ADJACE,NF TO WALL DETAIL �k Ulm SIDEWALK (SEE NOTE 1e1 SLCI IONS 1!J' (wrI A s fTYP.I FOR CURB DESAry.$ L1A%MK- SEE STD HJM *I k " T' r S ORRDU ArCH O STING p / d'WOE SMOOTH 7'V T BfLONTOP OF O1ROW LEDPEPoAETEA FR11611ED 7fR11DF EI'�GSI In. -. STIRPACE LIJ�Is .F - 1d" V �.- C04ENT CONCRETE CURB ADJACENT TOBUFFERSTRIP (C RDGUTTERSNOWM f r FOR L1FB DETARS y ~: SEE STD PLAN 501 Lip \ ` ua" TD W NOTESr � i � 7 Y t. Four fDos of the TidOwalK WiC71 shah be the m Bccesslbl and R Access Cable Va appe'le MUSL ha Grade of S,d-IL! [DnsuuLli Co npclr S�ndan 3. Eoncftl! CONTRACTION Jf1DYT 4 SEE[ mirtRrnt pedesULen [HSIDEWWfOMY e rolrta L'L'I; eD Dr Yar:Kal ,•6 •�A,� Jb •: orlxonglabMnxdiOni GratMgs, -� ;'•►. ? Coven, Junction BOxe3, CURSAN THExAFAILK I SMF 6brH 1 Dlh, PuA Saxes and other Tyn(ki wl:Nn [hD elddwih flu ah WIBt wrfece, 9n0 maYJ1 U10 ildewaOL 4 [ Cemen[ CenvetL Curb and 5 naa aerTNned In new For OIhOf r0ferencad N07E.5 see on -When replxammt wore STD PLAN 104.2. eY � Monali D+k Cement Cur4bul[dTxl WSDOT Plan F-3n !D•D3 Pav2O Burfacas rnustmmply wlln Lp hr 4.011L} PSI. ST{4 PLAN 1 p2-T as appiiCabe STD. PLAN 102 I'llB1SC WORKS CEMENT CONCRETE DF.PARTNIENT SIDEWALK CURS AND SlpE',yAl1K iSTI STO RAN leLll sr- C CONTRACTION JOINT JOIM AND FINISH DETAIL • • s •�P - JOINT FILLER E FULL -DEPTH EXPANSION JOINT I O ' LANE 'I LANE I I � I I I I I I INITIAL 2- DEEP SAWCUT OR GRIND, AND I I LIMIT OF FINAL OVERLAY. GRIND AND PAVE I FULL STREET WIDTH OVERLAY REQUIRED. I r I I / a I I ' I w , I r I Ir I r� I rl I I � I � i I I EDGE OF EXISTING PAVEMENT EDGE OF TRAVELED LANE (EDGE STRIPE) I r I r 1. I_ / L r - I VARIES: 4.5' MIN. (SEE STD PLAN 110.1) r - / I CENTER OF ANY MARKED LANE LINE, I PROVIDE NEW CHANNELIZATION AFTER OVLL'LAY r I SECONDARY FULL DEPTH SAWCUT FOR r / I I PROPOSED TRENCH I INITIAL 2" DEEP SAWCUT OR GRIND, AND { LIMIT Or FINAL OVERLAY. D AND E FULL STREET WIDTH OVERLCAYNREQUIRED LANE LANE i LANE I - 0 i I FOR TYPICAL SECTION AND NOTES SEE STANDARD PLAN 110.1 STD. PLAN - 110.2 PUBLIC WORKS REQUIRED SAWCUT, GRIND AND �i 11H DEPARTMENT OVERLAY FOR LONGITUDINAL TRENCHES ;;I) /O It-1) 10-3-19 Rol REVISION 13"x24' PLASTIC METER BOX EQUAL TO MID -STATES PLASTIC. INC. BCF SERIES MSBCF 1324-18 WITH 1.75' THICK DUCTILE IRON DIAMOND PLATE COVER EQUAL TO MID -STATES PLASTICS. INC. MSCBC-1324-R WITH READER LID AND 2" DRILLED HOLE FOR TOUCHREAD PIT LID (SEE DETAIL A -A) 9' MIN 12" MAX FINISH GRADE E • 4 36' MIN COVER M O 22-1/2' NEW DUCTILE IRON WATERMAIN CIS PRIVAT_ PIPING PIPING zI IN UNIMPROVED RIGHT OF j WAY INSTALL METER BOX AT PROPERTY LINE WITH 12' LONG COPPER TAILPIECE. W I ISIDEWALK ${ TOUCHREAD WATER METER TO BE SUPPLIED BY THE 12" a s CITY TYPE "K" SOFT o'D COPPER TUBING f IF SERVICE LINE TO HOUSE IS OR 1" TO BE INSTALLED IN THE FUTURE INSTALL FORD C14-33 OR 44 FIP:/7/GA/LVANIZED x COMPRESSION COUPLING ' LOF W DOWN TO CENTERLENE� OF WATER MAIN TO PROVIDE SLACK IN COPPER COPPERSETTER FOR 5/8"Ir3/4" METER: FORD SERVICE LINE TO METER. VBH72-15W-44-33G, OR MCOONALD BRASS: 21-215WCOQ33, OR MUELLER: 3/4-B-2470-2 WITH ANGLE BALL VALVE ON INLET AND SINGLE CHECK VALVE ON OUTLET CORPORATION STOP WITH BALL VALVE. FORD COPPERSFTTFR FOR i" METER: FORD VSH72-15W-44-44G, OR TAPERED THREAD (CC). QUICK JOINT McDONALD BRASS- 21-41SWC0044, OR MUELLER! 1-8-2470-2 (3/4' FB1000-3-Q) OR AY MCDONALD 4701E BOTH INLET AND OUTLET WITH QUICK JOINT. PADLOCK WINGS ON (1" F81000-4-0) OR AY MCDONALD 47018 INLET ANGLE SALL VALVE AND SINGLE CHECK VALVE ON OUTLET, ALL FITTINGS SHALL. BE WITH OUICK JOINT, NOTE: ALL METER BOXES INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST-IRON EQUAL TO CLYMPIC FCUNDARY- EXPANSION JOINTS MUSH BE INSTALLED ON BOTH SIDES OF METER BOX. A` A DRILL 2" DIA, HOLE FOR AMR (AUTOMATIC METER READ) TOUCHREAD DEVICE L 2-1/2" MIN. FROM NEAREST FF -- AND FRONT EDGE OF PIT LID I TYPICAL Rib NOTE: THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN ONE l SM. PLAN - 320.1 NOVEMBER 2009 VARIES: 4.5' MIN. LANE LINE MARKING SAWCUT AFTER BACKFILL 7�_DEPTH OF EXISTING PAVEMENT 2" - S" HMA E OF PAVEMENT, EDGE (SEE NOTE 2) 1' 1' OF CURB & GUTTER, OR MIN. MIN- CENTER OF LANE MARKING 2" HMA (SEE NOTE 2) 6" CRUSHED SURFACING TOP COURSE (CSTC) (9-03.9(3)) PER WSOOT STANDARD 2" SAWCUT AND REMOVE SPECIFCATIONS, COMPACTED TO 95% OR PLANE, SEAL WITH MODIFIED PROCTOR AR-4000W CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19), GRAVEL BORROW (9-03.14(1)) PER WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GEOTECH REPORT, COMPACTED TO WIDTH OF TRENCH AS REQUIRED BY SIZE OF 95% MODIFIED PROCTOR - PROPOSED IMPROVEMENT (SEE WSOOT STANDARD SPECIFICATION 2-09.4) PLUS AN PIPE ZONE BEDDING MATERIAL AND COMPACTION AS ALLOWANCE FOR ANY SHORING. SHORING. IF REQUIRED BY THE WSDOT STANDARD SPECIFICATIONS NEEDED, SHALL MEET THE REQUIREMENTS OF FOR THE TYPE OF IMPROVEMENT INSTALLED, EXCEPT: WSDOT STANDARD SPECIFICATION 7-08.3(1)B L I * FOR STORM AND WATER PIPE, PER STD PLAN 220.0 * FOR SANITARY SEWER, PER STD PLAN 405 TRENCH WIDTH * FOR JOINT UTILITY TRENCH, SAND WITH 95% PASSING A #4 SIEVE AND LESS THAN 5% PASSING A #200 SIEVE NOTES 1- WHEN XI 1EN EXISTING PAVEMENT IN A LANE REQUIRING A FULL WIDTH REPLACEMENT IS BROKEN OR DETERIORATED TO A PAVEMENT CONDITION INDEX RATING OF 70 OR LESS, THE EXISTING PAVEMENT IN THAT LANE, AND FOR THAT DISTANCE SO CLASSIFIED, SHALL BE REMOVED AND REPLACED WITH HMA MATCHING THE DEPTH USED IN THE EXISTING STREET OR THE DEPTH PER CITY STANDARD, WHICHEVER IS GREATER. 2. PRINCIPAL/ MINOR/COLLECTOR, ARTERIAL, & INDUSTRIAL ACCESS STREETS -- MATERIAL AND THICKNESS SHALL BE HMA CL 4." PG 64-22 AND MATCH EXISTING THICKNESS AND IN NO CASE LESS THAN 6"_ RESIDENTIAL ACCESS STREETS - HMA CL }' PG 54-22, THE THICKNESS SHALL BE THAT OF THE EXISTING PAVEMENT SECTION AND IN NO CASE LESS THAN 4'_ 3- WHEN THE "SAWCUT AFTER BACKFILL" ENCROACHES INTO AN ADJACENT LANE, CURB & GUTTER OR SHOULDER, THE AFFECTED LANE SHALL BE PLANED AND OVERLAID WITH HMA FULL WIDTH, THE CURB & GUTTER SHALL BE REMOVED AND REPLACED, OR THE SHOULDER SHALL BE PLANED OR REMOVED AND OVERLAID WITH HMA. 4- IF TRENCH UNDERMINES EXISTING SIDEWALK AND/OR CURBS, THEN THE SIDEWALK Al CURB SHALL BE REPLACED FROM EXPANSION JOINT TO EXPANSION JOINT- S- IF TRENCHING THROUGH EXISTING DRIVEWAY OR SIDEWALK RAMP, THE DRIVEWAY OR SIDEWALK RAMP SHALL BE REPLACED TO MEET ADA STANDARDS. TYPICAL LONGITUDINAL PATCH S1'D' PLAN - 11D.1 19 PUBLIC WORKS FOR FLEXIBLE PAVEMENT OR III k \ ED DEPARTMENTFRIGID PAVEMENT WITH OVERLAY )� IJ i 7 SURVEYED: DESIGNED: R. DECCIO DRAWN: LR CHECKED: R. DECCIO BY DATE APPR APPROVED: R. DECCIO SCALE: VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 1 "=20' fill ONE INCH DATUM 4 AT FULL SCALE Planning/ IF NOT ONE INCH SCALE ACCORDINGLY DocuSign Envelope ID: BEECF5B6-6U2A-4E4A-B436-A317AA638878 I SEE 37ANDARO PLANS 110. 110.1, 1102. AND 111 FOR PAVEMENT RESTORATION REQUIREMENTS SURFACE RESTORATION AS , SPECIFIED !N CONTRACT DOCUMENTS EXISTING PAVEMENT SURFACE 6" MIN. ,SEE NOTE 4 MEAT LIN E TR ENCH 'CRUSHED SURFACING TOP COURSE' PER WSDOT STD. SPEC 9.03-Il COMPACTED v v T095% OF MAXIMUM DENSITY \j J 'CRUSHED SURFACING TOP COURSE" PER / WSDOT STO. SPEC 9-M%3), "BANK RUN GRAVEL FOR TRENCH BACKFILL' PER v O WSDOT STD- SPEC 9.03, 19, OR "GRAVEL BORROW' PER WSDOT STO. SPEC 9-03,14(9), COMPACTED TO OF KMIMUM DENSITY 95% f\ v v BENCH AS NEEDED FOR SHORING SYSTEM WHEN DEPTH IS 4' OR GREATER PIPE � \ PIPE ZONE BEDDING AND BACKFILL PER STO. PLANS 220.00 AND 220,10 SEE NOTE 1 UNPAVEDAREM PAYED AREAS I NOTES: 1. SEE WSDOTIAPWA STANDARD SPECIFICATIONS SECTION 2-09.4 FOR MEASUREMENT OF TRENCH WIDTH. 2. EXCAVATIONS OVER a' DEEP SHALL COMPLY WITH THE SAFETY STANDARD OFSCRIRED IN CHAPTER 2WIS5 PART N OF THE WAG. 3. MAXIMUM BACKFILL DEPTH ABOVE PIPE SHALL NOT BE EXCEEDED, AS DETERMINED BY PIPE MANUFACTURER, 4. IN PAVED AREAS. IF PIPE HIS LESS THAN 3' OF COVER. USE "CRUSHED SURFACING TpP COURSE' FOR THE ENTIRE BACKFILL DEPTH ABOVE PIPE LANE. 5. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, OxAW[NG 15 NOT TO SCALE {NTS} STD. PLAN - 220.20 D 9/28/2018 GAZ oR PUBLIC WORKS TYPICAL TRENCH AND BACKFILL :45 A �,1 DEPARTMENT DATE ', I[uSign Envelope 10: 6EECF5B6-602AAE4A-8436-A317AA638878 CONFIGURATION ON SLOPING GROUND DOWNSPOUT WITH CLE►NOUT FILTER, SEE DETAIL CLEANOUT PER STD- PLAN 22,00 le YIN, LEVEL TRENCH YVTTN PERFORATED PIPE, SEE NOTE t Tr MaJ-I 5, MIN- 3 I II- a LL I � I CL.EANOUT PER M. PLAN MOO TO STORY DRAY1 SY$TEM , FOOTING IXWHBYPASS- 5' 5' CLEANCUT PER ON. MIN. I M. PLAN =-00 TO STORM DRAIN SYSTEM FIOWINSPOUSEE�WU�CLEANOUT 10'MIN. LEVEL TRENCH WIT,i PERFORATED PIPE. SEE NOTE 1 - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -- C ONFIGURATION ON FLAT GROUND PLAN VIEW OF PARCEL COMPACTED TOPSOIL OR OTHER CLEAN FILL NONAWNEN GEOTEx ILE FOR SEPARATION Lr MIN. PVC ON TOP AND SIDESCF TRENCH PER WSDOT PERFORATED PIPE $PEQIFICATIONS SECTION g8U20 TABLE 3 PER ASTM D1765 sDLlos• n LEAVES _ - FILTER SCAB E]N 16•MIN- _ RWASHED ORAN ORAIH ROCK 2'•B TO ,'.. GROUND t 24• MIN. �-• •IE TYPICAL DOWNSPOUT UNDISTURBEDNATFVE$OIL MIN. 1• ABOVE SEASONAL HIGH FILTER DETAIL GROUNDWATER TABLE SECTION A NOTE& 1. TRENCH LENGTH TO BE 10 FEET W LENGTH FOR EVERY 5,D00 SF 0FC0III•RI8UTIN0 IMPERVIOUS SURFACE, OR 35p00SF OF NON-NATIVE PERVIOUS SURFACE- OR PORTION THEREOF. (iENERAL NOTE&: 1. INFILTRATION N M T F RUNOFF •FAMI Y P HOMES T LIRA THE U REO OR00 LINO FROM &OGLE L OR DU LE% EB OR O CONTROL BASEMENT FLOWING C V REGULATIONS FOR UNDERGROUND WJECTx]N T CONSULTWA DEPARTMENT OF D RAM(I RUNOFF MAN CONTROL PROGRAM (IJIQI FOR OTHER TYPE$OF RUNOFF MA.NAC,,EMENT. 2. IMPERVIQU$ AREAS LARGER THAN 1e,00e WAND NOI TTVK PERVIOUS AREA$ LARGER THAN 35M $F MAY REOLJIRE LARGER PIPE AND SHOULD BE DESIGNED BY CIVIL ENGINEER I. THE PERFORATED PIPE MAY NOT BE PLACED IN A CR ITICAL AREA BUFFER OR ON SLOPES STEEPER THAN 25% 4. SEE CONSTRUCTION PUIN$ FOR SPECIFIC PROJECT REQUIREMENT$. UNLESS OTHERWISE NOTED, DRAWING LS NOT TO SCALE [NTSI PUBLIC WORKS PERFORATED STUB -OUT STD. PLAN - 263.40 W ° ` DEPARTMENT ice CONNECTION GAZ 9/28/2018 1 :45 A DAIS CITY OF RENTON uilding/Public Works Dept. R-405207 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING jchavez 10/18/2019 AVON DEVELOPMENT 2 LOT SHORT PLAT DETAILS DATE: 4-2-19 PAGE: R-405207 SHEET: 7 OF: 9 J IX O V) F- O J CV F- Z W O J W W 0 Z O 3/8- PP.EMOLDED JONT FILLER (TYP)- C FRAME ORATE -$F,€HOY /S•R X 5/8"D DUMMY JOINT -BEE HOTE2 - D• 2 U' � 1 II I I L PLAN ViCW PARCH FRAME AND GHIITE - NOT NCL.UDED 1 /2• R. 1• R. YLINND nUTTER BID CE]LI • h 3• `° SLOPE TOPOF a . 1• R. •� R=MAY . 9 p P .'•,• a 5 v. •• ADJUSTMENT SECTION^NITTMCLUDED UT CURB AND GUTTER END am DITCH BABIN • NOT 1Nd-UDED v •, ,A •h IN CURB ANO GUTTER 91DREM SECTION Ifs GFNERAi_ NOTES: "' 1- The Intent of INN design I to fad litate the mmonl Of a catch basin with minimal dlsturbanoe of the curie. 2. The expanal on Joints of the ` s. � �.� ' + "' r adjacent eldemik shalli be -adjusted to be In nna with these curb - expansion Joints ISOtXR41C VIEW CEMENT CONCRETE CURB' - 11}i.i * + t?usirc va>�xs INSTALLATION AT ❑EPAR`CMENT CATCH BASINS4 qd ' ^ DocuSign Envelope ID: 6EECF5B6.602A-4E4A-B436-A317AA638878 Y / O 1 W 5W L Z W V/ f= ., rid � N ~ N O �Ck:: Q g 1 of - 0 E �OUTFALLTGSMEAM o- LL L - LLI DUMP ND POL LII LINTS I SOLT-DOWN SLOT. I Ur SEE DETAIL AND _NOTE 1 1 I!4• bI8' I I r BOLT -DOWN SLOT DETAIL - - SEE NOTE 1 - - - TOP m /1 VW RECESSED LETTERING ISOMETRIC 24' 7 OR S EQUAL SPACES TF! DIRECTION FLOW 15W MAX- SJ PUBLIC WORKS +� DEPARTMENT SECTION B NOTES: I BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES. GRATES. AND COVERS. UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5W-11 NC x 7 ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF SOLT•DOWN HOLES VARIES BY MANUFACTURER. 2. REFER TO STANDARD SPECIFICATION 9415.15(2) FOR ADDITIONAL REQUIREMENTS. 3. FOR FRAME DETAILS. SEE STANDARD PLAN 204,W, UNLESS OTHERWISE NOTED, DRAWING 1S NOT TO SCALE (NT51 STD. PLAN - 204.20 O : RECTANGULAR VANED GRATE GAZ 9/28/2018 I :45 n SAZEI DESIGN GROUP, LLC 6608 110TH AVE. N.E. KIRKLAND, WA. 98033 TEL. (425) 212-2280 FAX. (425) 889-6887 DocuSign Envelope ID; 6EECF5B6-602A-4E4A-6436-A317AA638878 TOE IN 4'. 4' NOTES: 1. CONDITIONS OF USE 1 1 PLASTIC COVERING MAYBE USED ON DISTURBED AREAS THAT REQUIRE COVER MEASURES FOR LESS THAN 30 DAYS. 1 2 PLASTIC IS PARTICULARLY USEFUL FOR PROTECTING CUT AND FILL SLOPES AND STOCKPILES 1 3 CLEAR PLASTIC SHEETING MAY BE USED OVER NEWLY -SEEDED AREAS TO CREATE A GREENHOUSE EFFECT AND ENCOURAGE GRASS GROW Tri CLEAR PLASTIC SHOULD NOT BE USED FOR THIS PURPOSE DURING THE SUMMER MONTHS. 1 4 THIS METHOD SHALL NOT BE USED UPSLOPE OF AREAS THAT MIGHT BE ADVERSELY IMPACTED BY RUNOFF. SUCH AREAS INCLUDE STEEP AND UNSTABLE SLOPES, 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.L PLASTIC SHEETING SHOULD HAVE A MINIMUM THICKNESS OF 0-06 MILLIMETERS. 22. IF EROSION AT THE TOE OF A SLOPE IS LIKELY, A GRAVEL BERM. RIPRAP, OR OTHER SUITABLE PROTECTION SHALL BE INSTALLED AT THE TOE OF THE SLOPE IN ORDER TO REDUCE THE VELOCITY OF RUNOFF. 23. TIRES. SAND BAGS. OR EQUIVALENT MAY BE USED TO WEIGHT PLASTIC 24. SEAMS BETWEEN SHEETS MUST OVERLAP A MINIMUM OF 12 INCHES AND BE WEIGHTED OR TAPED. 3. MAINTENANCE STANDARDS 3.1. TORN SHEETS MUST BE REPLACED AND OPEN SEAMS REPAIRED. 3.2, IF THE PLASTIC BEGINS TO DETERIORATE DUE TO ULTRAVIOLET RADIATION, IT MUST BE COMPLETELY REMOVED AND REPLACED 3.3. WHEN THE PLASTIC IS NO LONGER NEEDED. R SHALL BE COMPLETELY REMOVED. aRIPUBLIC WORKS DEPARTMENT PLASTIC COVERING DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 Imo. TRENCH WIDTH. SEE NOTE 3 PIPE ZONE SFnnlnlr_ gun SACKFILL. SE FOUNC LEVEL FOUNDATION MATERIAL, IF REQUIRED, SEE NOTE 5 Pi PE ZONE BEDDING AND BACK PILL. SEE NOTE - FOUNDATION LEVEL RIGID PIPE NOTES: 1 PIPE COMPACTION LIMITS SHOWN ON THIS PLAN ARE FOR PIPE CONSTRUCTION IN AN EMBANKMENT. FOR PIPE CONSTRUCTION IN A TRENCH, THE HORIZONTAL LIMITS OF THE PIPE COMPACTION ZONE SHALL BE THE WALLS OF THE TRENCH. 2. 0.D IS EQUAL TO THE OUTSIDE DIAMETER OF A PIPE OR THE OUTSIDE SPAN OF PIPE -ARCH 3, SEE STANDARD WS DOTeAPWA SPECIFICATIONS SECTION 2-09.4 FOR TRENCH WIDTH. 4. PIPE ZONE BEDDING AND SACKFILL MATERIAL SHALL BE PLACED IN 6" LOOSE LAYERS AND COMPACTED TO 95% MAXIMUM DENSITY 5. EXCAVATE UNSTABLE MATERIAL DOWN TO FIRM SOIL AND REPLACE WITH FOUNDATION MATERIAL CLASS A OR B PER STANDARD WSDOTIAPWA SPECIF ICATIONS SECTION M177, ®GRAVEL BACKF ILL FOR PIPE ZONE BE (WSDOT 9.03 12(3)) OR MAINTENANCE ROCK (WSDDT 9-0a.9(4)) TRENCH WIDTH, SEE NOTE 3 SPAN S' 79M RISE FOUDATIDN fuWTER1AL, IF REQUIRED, SEE NOTE 5 PIPE - ARCH 4ERWISF NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 213.30 GAZ 9/28/2018 1 :45 Al MINIMUM ALLOWED IN ZONE 1 PIPE TYPE COVER IFTI PUBLIC? PRIVATE.? OF THE APAP CORRUGATED 20 YES YES YES STEEL PIPE SPIRAL RIB STEEL 2.0 YES YES YES PIPE PLAIN CONCRETE PIPE (PCP) 2.0 NO YES NO REINFORCED CONCRETE PIPE 1.0 YES YES NO MIR) CORRUGATEDOR SPIRAL RIB 2.0 YES YES NO ALUMINUM PIPE DUCTILE IRON PIPE 1.0 YES YES YE". CIRCULAR PIPE DIAMETER MINIMUM DISTANCE BETWEEN BARRELS Ir TO 24• 12- 30" TO 96" ❑IAMETER r 3 1 OZ" TO 186" 49' PIPE -ARCH SPAN MINIMUM DISTANCE BETWEEN BARRELS 18" TO 36' 12" 43- TO 142' SPAN r 3 148" TO 199' 4(I UNLESS OTH€AWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 220.00 URIPUBLIC WORKS PIPE ZONE BEDDING AND APPR ED DEPARTMENT COMPACTION -RIGID PIPE GAZ 9/28/2018 I •we Wmrr.vain DATE 10-3-19 REVISION :45 AN DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638876 29 1i4" RECESSEDALLEN HEAD CAP SCREW SIB• - I I NC x 7 C TE PRONE SECTION BOLT•DOWN DETAIL SEE NOTE 2 241 W 1 I SECTION A SEE DETAIL ISOMETRIC VIEW I �•I raw 1!•S ' T va NOTES: I . THIS 1 4 1R• J SEE FRAME IS DAR DPLANS 204.10..204.20, 20D4.300. TES OR COVERS, AND 204 40,'� 1\ 1 TV8" I 2. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES. GRATES, AND ' FRAME THAT ARSVERTICALLY ALIGNIEO W THOTHE GRATE ORLCOS VINE R SLOTS. 1 SIB' THE FRAME SHALL ACCEPT THE 518'-11 RC It 2* ALLEN HEAD CAR SCREW BY \ 4• ' BOLT DOW HOLG TAPPED. EOTHER RE HOLES BY MANUFACTURER. LOCATION OF 2 112" _ / 3. REFER TO STANDARD SPECIFICATION 9A5.15(2) FOR ADDITIONAL DETAIL / REQUIREMENTS. UNCE55 OTHERWISE NOTED, DRAWING 15 NOT TO SOME (NTS) STD. PLAN - 204.OD ► PUBLIC WORKS RECTANGULAR FRAME D 9/28/2018 I :45 A DEPARTMENT GAZ ItIW7r,.,,, w�.n....w...,.,v DATE DocuSign Envelope ID: 6EECF5B"02A-4E4A-B436-A317AA638878 SEE STANDARD PLANS 110. 110.1. 1102, AND 1 11 FOR PAVEMENT RESTORATION REQUIREMENTS SURFACE RESTORATION AS , SPECIFIED IN CONTRACT DOCUMENTS I 1Y MEN. EXIST ING PAVEMENT SURFACE - ff----------------- -------- -- J f v y MIIN.. SEE NOTE 4 NEAT LINE TRENCH ` 'CRUSHED SURFACING TOP COURSE' PER W9007 STD- SPEC 9.03.9(3). COMPACTED TO 95% OF MAXIMUM DENSF Y 'CRUSHED SURFACING TOP COURSE' PER WSDOT STD. SPEC 9.03.9(3). -BANK RUN GRAVEL FOR TRENCH BACKFILL' PER WSDOT STO SPEC 99-03.19.OR-GRAVEL BORROW PE R WSOOT STD. SPEC "3 14(1). COMPACTED TO SM/ OF MAXIMUM 0ENS11Y BENCH AS NEEDED FOR SHORING SYSTEM WHEN JJ DEPTH IS 4' OR GREATER PIPE \ PIPE ZONE BEDDING AND BACKFILL ` PER STD. PLANS 220-00 AND 220,10 �- SEE NOTE 1 UNPAVED AREAS I PAVED AREAS I NOTES: 1• SEE WSDOPAPWA STANDARD SPECIFICATIONS SECTION 2-00.4 FOR MEASUREMENT OF TRENCH WIDTH. 2. EXCAVATIONS OVER 4• DEEP SHALL COMPLY WITH THE SAFETY STANDARD DESCRIBED IN CHAPTER 296-155 PART N OF THE WAG. 3. MAXIMUM SAC KFILL DEPTH ABOVE PIPE SHALL NOT BE EXCEEDED, AS DETERMINED BY PIPE MANUFACTURER. 4. IN PAVED AREAS, IF PIPE HAS LESS THAN X OF COVER. USE'CRUSHED SURFACING TOP COURSE' FOR THE ENTIRE: BACKFILL DEPTH ABOVE PIPE ZONE. 5 SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 220.20 • PUBLIC WORKS TYPICAL TRENCH AND BACKFILL D 9/28/2018 1 -�It DEPARTMENT GAZ 1%17w.vANln A4nWNvew DATE ID 4-2-11 RAD SURVEYED: DESIGNED: R. DECCIO DRAWN: LR CHECKED: R. DECCIO BY DATE APPR APPROVED: R. DECCIO SCALE: 1 "=20' I ONE INCH I AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY DocuSign Envelope ID: 6EECF5B6.602A-4E4A-B436-A317AA638878 ONE N3 BAR HOOP FOR W HEIGHT INCREMENT ISPACED EQUALLY). SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION D rp 43 BAR FACH CORNER I 43 BAR EACH SIDE I`Y 73 BAR EACH WAY PRECAST BASE SECTION 413 BAR HOOP PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REIN FORCED OR PLAIN 12" CONCRETE ALL METAL PIPE 15• CPSSP•, 12,STD. SPEC. 9.05,m SOLID WALL PVC. STD, SPEC. M5.1211} 15' PROFILE WALL PVC, STD. SPEC. 9-05.12(2} 15' 'CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: , AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN EN THE PRECAST BASE SECTION. FIBERS IPLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(91). OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WRH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THERECTANGULAR ADJUSTMENT SECTION, WIRE MESH AVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2 THE XNCCKOUT DIAMETER SHALL NOT BE GREATER THAN 2(Y KNOCKOUTS SHALL HAVE A WALL THICKNESS OF Z' MINIMUM TO Z.5- MAXIMUM. PROVIDE A 1.5' MINIMUM GAP BETWEEk THE KNOCKOUT WALL AIJD THE OUTSIDE OF THE PIPE. AFTER THE PIPE 13 INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE W HH STANDARD SPECIFICA11014 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN 5- THE PRECAST BASE SECTION MAY AVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1 H:24V OR STEEPER 6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR *3 BAR EACH NONSHRINKAPPDCATIONS INACCOROANCE WITH CORNER I9• MIN. STANDARD SPECIFICATION 9.2Q.3(2}. 8 ALL GRAPE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STRDARD SPECIFICATION 9.04-3. THEN APPLY MORTAR TO INSIDE AND DUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9 MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10. FRAME SHALL E ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND SEE NOTE 1 REMAIN VISIBLE UPON COMPLETION. ALTERNATIVE PRECAST BASE SECTION UNLESS OTH ERW15E NOTED, DRAWING IS NOT TO SCALE INTS:. tAl�D. PLAN - 200.0D a PUBLIC WORKS DEPARTMENT CATCH BASIN TYPE 1 9/28/201g I GATE .. eo rEN+Htt.A)E4 wcwu. Nuas;_ - ^ dr rn r Kawee -. f T 1 )rwMaw Aen fir., tm se'EArANva mnRKl cdErrt c-Iee[a lOEwAtM tts.oTFa :T - 7 - CONSTM41 4jow elYI R4M OIN fQtgTE1 M - -� GUMP ) arCONINA IMPMI , IiE[ s1Mr P LAN VIEW mPe a sHo NN CI A C: s CU" waAm ISEE NOTE n ..Nu T• 1eellLNTd - _ _ eneAA®lonemn • MINF --/�+�-� 1_Y� il'1ldtERGfeFA Ot-'rEP eawiu -.__ arN.+NaaAaarrrt.el �_ _ fFeipl O Ifeleo µ`�InP1 LOFww.,M�TR \ m o,.�nNceurvaw- �AAswr ro.e n-e.e hawvmas.w _ _ r eA \ - anew. ar w oN.nw.rs.nn - �-�41 O e.aw[uactpTm / _ For NOTES see STD PLAN 104.2 Y STD. PLAN - 104.4 PUBLIC WORKS CEMENT CONCRETE DRIVEWAY PFT R 11). DFPARTMFKT ENTRANCE - TYPES C1B, C28, +' O C3B, and C-MAXB (WITH BUFFER) G,.0 Z.mme -, Public Wo.Li U-NI A. :45 AN VERTICAL: NAVD 1988 CITY 0 F HORIZONTAL: NANO 1983/183/1991 RENTON (DI 4 DATU M Planning/Building/Public Works Dept. :45 Al nJ ear I� O �2 V / O IN COMPLIANCE WITH CITY OF RENTON STANDARDS CV EDEVELOPMENT ENGINEERING Z a W ez 10/18/2019 C L Nam O __J W DATE: AVON DEVELOPMENT 2 LOT 4-2-19 Q SHORT PLAT PAGE:FIELDOOK: PAGE: Z DRAWING NO: O R-405208 > DETAILS SHEET: 8 OF: 8 L0 O 1 O 1 0 W I- I- nJ 1L I- O r W O J CV I- Z W 2 O J W W 0 Z \O Lr_I OS ~ (Z)p N ~ N O � � g DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER. HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS. THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 1 BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS. A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY. THE APPLICANT. AND THE APPLICANT'S CONTRACTOR 2 THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE. AND FEDERAL PERMITS PRIOR TO CONSTRUCTION 3 ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA)- IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY 4 APPROVAL OF THE ROAD. GRADING. PARKING, BUILDING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E,G. WATER. SEWER, GAS, ELECTRICAL ETC.) PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS. AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY 5. A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANT'S CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN. AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN THE APPLICANT SHALL RECORD ON THE AS -BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICT EXISTS 7. VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH). UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS. 8 ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 96% MAXIMUM DRY DENSITY PER SECTION 2-03.304)D - COMPACTION AND MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS. ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92 % OF MAXIMUM DRY DENSITY 9 OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS 10. ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. 11. ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO. OR IN CONJUNCTION WITH. ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CITY, 12. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL. AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 220,10. AND 22020 13. STEEL PIPE SHALL BE ALUMINIZED. OR GALVANIZED WITH ASPHALT TREATMENT 1. 2, OR 51NSIDE AND OUTSIDE 14. ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT -LOCKING LIDS PER THE CITY STANDARD PLAN 204 10, 204.20, 204.30, AND 204.50. STRUCTURES SHALL HAVE. • RECTANGULAR OR ROUND. SOLID LIDS WHEN NOT COLLECTING RUNOFF. AND OUTSIDE OF THE ROADWAY • ROUND. SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/GUTTER LINE • ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 15. BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM. 16. LIDS OF MANHOLESICATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING ALL MANHOLE,CATCH BASIN RIMS SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES. UNLESS OTHERWISE SHOWN. 17 ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3.1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 267.00 AlOURmar PUBLIC WORKS SURFACE WATER STANDARD PLAN PPR n m]� DEPARTMENT NOTES (1 OF 2) GAZ 9/28/2018 1 OraF DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER. HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT HOWEVER. THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 18 ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED. SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT AND SHALL MEET THE FOLLOWING SPECIFICATIONS- • 4 .8 INCH ROCK 140 - 70% PASSING. • 2 .4 INCH ROCK 1 30. 40 % PASSING. AND • LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 19. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE. UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BMPS. 20, THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED "STORM' SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00 21 ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION 22, ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS. GUTTERS AND/OR PAVEMENT. 23. ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED. 24 FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED. GRADED. LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 26400 25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION ANDlOR LIABILITY CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION. 26. ADEQUATE SAFEGUARDS, SAFETY DEVICES. PROTECTIVE EQUIPMENT. FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH. AND SAFETY OF THE PUBLIC. AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY 27. PROJECTS LOCATED WITHIN THE CITY's AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT M6 OF THE RENTON SWDM AND AQUIFER PROTECTION REGULATIONS (RMC 4-3-050), 28. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASINlMANHOLE LIDS, CLEANOUTS, INLETS. ETC.) IN THE STREET TRAVEL LANE WHEEL PATH. INTERSECTIONS OF STREET TRAVEL LANES. BIKE LANES, SIDEWALKS. AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID LID PER ADA REQUIREMENTS. 29. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS- PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT. 30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2 1.A2 OF THE RENTON SWDM 31 CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES- COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION AT LEAST ONE TEST SHALL BE CONDUCTED PER 1.000 SQUARE FEET OF PERMEABLE PAVEMENT IF THIS TEST IS NOT CONCLUSIVE. THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS (E. G. PARKING AREAS). TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTSI STD. PLAN - 267.10 SURFACE WATER STANDARD PLAN IAPPRMD NOTES (2 OF 2) GAZ 9/28/2018 I DATF SAZEI DESIGN GROUP, LLC 6608 110TH AVE. N. E. KIRKLAND, WA. 98033 TEL. (425) 212-2280 FAX. (425) 889-6887 :4S M : 4 S At SW 1 /4 OF SE 1 /4 OF SEC. 5, TWP. 23 N., RNG. 5 E., W.M. CITY OF RENTON, STATE OF WASHINGTON CITY OF RENTON STANDARDS All materials and workmanship shall be in accordance with the City of Renton Standard and Supplemental Specifications (current adopted version) except where otherwise noted in these standards. Materials and workmanship are required to be in conformance with standards for the Standard Specifications for Road, Bridge, and Municipal Construction prepared by the Washington State Chapter of the American Public Works Association (APWA) and the Washington State Department of Transportation (WSDOT) and shall comply with the current edition, as modified by the City of Renton Supplemental Specifications. 1. An asphalt paver shall be used in accordance with Section 5-04.3(3) of Standard Specifications. A "Layton Box" or equal may be used in place of the power -propelled paver. Rollers shall be used in accordance with Section 5- 04.3(4) of the Standard Specifications. "Plate Compactors" and "Jumping Jacks" shall not be used in lieu of rollers. 2. Trench backfill and resurfacing shall be as shown in the City of Renton Standard Details, unless modified by the City permit. Surfacing depths shown in the standard details are minimums and may be increased by the Engineer to meet traffic loads or site conditions. 3. Requirement for Patching, Overlay, and Overlay Widths: Al trench and pavement cuts shall be made by sawcut or by grinding. Sawcuts or grinding shall be a minimum of one foot (1') outside the trench width. The top two inches (2") of asphalt shall be ground down to a minimum distance of one foot (1') beyond the actual outside edges of the trench and shall be replaced with two inches (2") of Class 8 asphalt, per City of Renton Standard Plans. At the discretion of the engineer, a full street width overlay may be required. Lane -width or a full street -width overlay will be determined based upon the location and length of the proposed trench within the roadway cross-section. Changes in field conditions may warrant implementation of additional overlay requirements. a. Trenches (Road Crossings): (1) The minimum width of a transverse patch (road crossing) shall be six and one-half feet (6.S'). See City of Renton Standard Plans. (2) Any affected lane will be ground down two inches (2") and paved forthe entire width of the lane. (3) The patch shall be a minimum of one foot (1') beyond the excavation and patch length shall be a minimum of an entire traveled lane. (4) If the outside of the trenching is within three feet (T) of any adjacent lane line, the entire adjacent traveled lane affected will be repaved. (5) An area including the trench and one foot (1') on each side of the trench but not less than six and one- half feet (6.5') total for the entire width of the affected traveled lanes will be ground down to a depth of two inches (2"). A two-inch (2") overlay of Class B asphalt will be applied per City standards. b. Trenches Running Parallel with the Street: (1) The minimum width of a longitudinal patch shall be four and one-half feet (4.5'). See City of Renton Standard Plans. (2) If the trenching is within a single traveled lane, an entire lane -width overlay will be required. (3) If the outside of the trenching is within three feet (3') of any adjacent lane line, the entire adjacent traveled land affected will be overlaid. (4) If the trenching is greater than or equal to 30% of lane per block (660 foot maximum block length), or if the total patches exceed 12 per block, then the lanes affected will be overlaid. Minimum overlay shall include all patches within the {dock section. (5) The entire traveled lane width for the length of the trench and an additional ten feet (10') at each end of the trench will be ground down to a depth of two inches (2"). A two-inch (2") overlay of Class B will be applied per City standards. C. Potholing: Potholing shall meet the same requirements as trenching and pavement restoration. Potholing shall be a minimum of one foot (1') beyond the excavation. All affected lanes will be ground down to a depth of two inches (2") and paved not less than six and one half Feet (6.5') wide for the entire width of tlTe lane. Potholes greater than five feet (5') it) length, width or diameter shall be restored to trench restoration standards. In all cases potholes shall be repaired per Renton Standard Plans. Restoration requirements utilizing vactor equipment will be determined by the Engineer. 4. Pavement Removal in Lieu of Grinding: The contractor in all cases can remove the pavement in the replacement area instead of grinding out the specified two inches (2") of asphalt. Full pavement replacement to meet or exceed the existing pavement depth will be required for the area of pavement removal. Patching of pervious concrete shall follow American Concrete Institute (ACI) 522.1-13. Porous asphalt shall be specified on a project -by -project basis by the engineer. Permeable materials should be replaced in -kind where feasible. Patching porous asphalt with conventional asphalt is acceptable if it is no more than ten percent (10%) of the total facility area or does not impact the overall facility function. Appropriate precautions shall be taken duringpavernentrepair and replacement efforts to prevent clogging of adjacent surfaces. S. Trench Backfiil and Restoration Construction Requirements: a. Trench restoration shall be either by a patch or overlay method, as required and indicated on City of Renton Standard Plans. b. All trench and pave merit cuts, which will not be overlaid, shall be made by sawcut or grinding. Sawcuts shall be a minimum of two feet (2') outside the excavated trench width. c. All trenching within the top four feet (4') shall be backfilled with crushed surfacing materials conforming to Section 4-04 of the Standard Specifications. Any trenching over four feet (4') in depth may use materials approved by the Engineer or Materials Lab for backfilling below the four -foot (4')depth. d. If the existing material (or other material) is determined by the Engineer to be suitable for backfill, the contractor may use the native material except that the top six inches (6") shall be crushed surfacing tap course material. e. The trench shall be compacted to a minimum ninety -Five percent (95%) density, as described in Section 2- 03 of the Standard Specifications. In the top six feet (6') of any trench, backfill compaction shall be performed in eight (9) to twelve -inch (12") lifts. Any trench deeper than six feet (6') may be compacted in twenty-four inch (24") lifts, up to the top six-foot (6') zone. All trench backfill shall be firm and unyielding but in no case shall be compacted to more than ninety-two percent (92%) of maximum density in permeable pavement areas. f. All compaction shall be performed by mechanical methods. The compaction tests may be performed in four -foot (4') vertical increments maximum. The test results shall be giver) to the Engineer for review and approval prior to paving. The number and location of tests required shall be determined by the Engineer. d. Temporary restoration of trenches for overnight use shall be accomplished by using MC mix (cold mix), Asphalt Treated Base (ATB), or steel plates, as approved by the Engineer. ATE; used for temporary restoration may be dumped directly into the trench, bladed out and rolled. After rolling, the trench must be filled flush with asphalt to provide a smooth riding surface. If the temporary trench restoration does 10-3-19 J I NO. I REVISION not hold up, the contractor shall repair the patch within eight hours of being notified of the problem by the City. This requirement applies 24 hours per day, seven days per week. In the event that the City determines to repair the temporary patch, the contractor shall reimburse the City in an amount that is double the City's costs in repairing the patch, with the second half of the reimbursement to represent City overhead and hidden costs. e. Asphalt Concrete Class E or Class B shall be placed to the compacted depth as required and indicated on City of Renton Standard Plans or as directed by the Engineer. The grade of aspha€t shall he AR-4000W. The materials shall be made in conformance with Section 9-02.1(4) of the StandardSpecifications. f. Tack coat shall be applied to the existing pavement at edge of saw cuts and shall be emulsified asphalt grade CSS-1, as specified in Section 9-02.1(6) of the Standard Specifications. Tack shall be applied as specified in Section 5-04 of the Standard Specifications. g. Asphalt Concrete Class E or Class B shall be placed in accordance with Section 5-04 of the Standard Specifications; except those longitudinal joints between successive layers of asphalt concrete shall be displaced laterally a minimum of twelve inches (12"), unless otherwise approved by the Engineer. Fine and coarse aggregate shall be in accordance with Section 9-03.8 of the Standard Specifications. All street surfaces, walks or driveways within the street trenching areas shall be feathered and shimmed to an extent that provides a smooth -riding connection and expeditious drainage flow for the newly paved surface. Feathering and shimming shall not decrease the minimum vertical curb depth below four inches (4") for storm water flow. The Engineer may require additional grinding to increase the curb depth available For storm water flow in areas that are inadequate. Shimmingand feathering as required by the Engineer shall be accomplished by raking out the oversized aggregates from the Class B mix as appropriate. Surface smoothness shall be per Section 5-04.3(13) of the Standard Specifications. The paving shall be corrected by removal and repaving of the trench only. Asphalt patch depths will vary based upon the streets being trenched. The actual depths of asphalt and the work to be performed shall be as required and indicated on City of Renton Standard Plans. Compaction of all lifts of asphalt shall be a minimum ninety-two percent (92%) of density as determined by WSDOT Test Method 705. The number of tests required shall be determined by the Engineer. Testing shall be performed by an independent testing lab with the results being supplied to the Engineer. Testing is not intended to relieve the contractor from any liability for the trench restoration. It is intended to show the inspector, and the City, that the restoration meets these specifications. h. All joints, except those associated with permeable pavement, shall be sealed using paving asphalt AR- 4000W. i. When trenching within the unpaved roadway shoulder(s), the shoulder shall be restored to its original condition, or better. j. The final patch shall be completed as soon as possible and shall not exceed fifteen (15) working days after first opening the trench. This time frame may be adjusted if delays are due to inclement paving weather or other adverse conditions that may exist. However, delaying of final patch or overlay work is subject to the Engineer's approval. The Engineer may deem it necessary to complete the work within the fifteen (15) working daytime frameand not allow any time extension. Should thisoccur, the contractor shall perform the necessary work, as directed by the Engineer. k. A City of Renton Temporary Traffic Control Plan (from Renton Transportation Engineering) shall be submitted and approved by the Engineer a minimum of three (3) working days prior to commencement of work. 6. Removal of Utility Locate Markings from Sidewalks Required: The permittee will be required to remove utility locate marks on sidewalksonly within the Center Downtown Zone. The perm ittee shall remove the utility locate marks within 14 days of job completion. SURVEYED: DESIGNED: R. DECCIO DRAWN: LR CHECKED: R. DECCIO BY I DATE I APPR I APPROVED: R. DECCIO SCALE: VERTICAL: NAVD 1988 • HORIZONTAL: NAD 1983/1991 1 "=20' DATU M PRI ONE INCH AT FULL SCALE Planning/ IF NOT ONE INCH SCALE ACCORDINGLY CITY OF RENTON uilding/Public Works Dept. R-405209 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING jchavez 10/18/2019 ' AVON DEVELOPMENT 2 LOT SHORT PLAT NOTES DATE: 3-22-19 O J CV Z W O J W W 0 PAGE: DRAWING NO: Z R-405209 ' SHEET: OF:9 N 0 1 O w I— I — a 11..E 0 c1i 0 J N I— Z w 2 0 w w 0 Z 0 a T O N O 1 w Cm G Z w w N 2 zz cc,po z W ,z OJ N N 1< LQzoo �I �LLJo n z o� U N Cr- x a C' W �x EX CB RIM 263.83 INV=262.53 (12" CONC- ) INV=259.23 (12" CONC- ) N \ S1 D Sjl 3 SD SD SD SD 1 \III w/ w w w I \w O I 3 \ \ 3 \ 3 \ 3 o \ \ ISTA: 6+58.55 I / TAX PARCEL / 334390-2565 / 2� NOTE 3�FFSE . w w 7+00 I \ - Nt59-43 49, W 01.9Z \\LOT 5 \� TAX PARCEL 559205-2568 LINCOLN PLACE SHORT PLAT REC. NO. 2016020900007 THE SAFE PEDESTRIAN WALKWAY GOES FROM THE SITE, EAST ALONG NE 14TH STREET TO MONTEREY AVE NE THEN NORTH UP MONTEREY AVE NE TO NE 16TH STREET THEN EAST TO INTERSECTION OF EDMONDS AVE NE AT MCKNIGHT MIDDLE SCHOOL 11 SW 1/4 OF SE 1/4 OF SEC. 5, TWP. 23 N., RNG. 5 E., W.M. CITY OF RENTON, STATE OF WASHINGTON CAS —GAS —EQ \ CD / -\w w w\ w w w w w w \w w Q \ \ L7 \ 14 TH S TREE T\ \ \ \ 8+0 Q \ \ 1 S -\---S S S\ S S �S S SI S P --�- F P P/ p — STAX7+62.45 EX CB \ RIM 274.49 INV=271.59 (12" CONC—E) o� \ W M 0 O Z LOT 6 TAX PARCEL 559205-2563 I, r GRAPHIC SCALE 20 0 10 20 40 SAZEI DESIGN GROUP, LLC ° 1 �P of was �Fc �� tick 6608 11OTH AVE. N.E. KI RKLAN D, WA. 98033693 �N Z TEL. (425) 212-2280 O/STE FAX. (425) 889-6887 NAL 11 12-3-20 NO. J. DECIS10N: LEGEND GASED MONUMENT (OGGUPIED 10/1(9) • EXISTIN6 CORNER AS DESGRIBED &' WOOD FENCE (UNLESS OTHERWISE NOTED) ° 450.0 SPOT ELEVATION PPS POWER POLE H YD�6 HYDRANT w M WATER VALVE w Z WATER METER % POWER METER ® GATGH BASIN SSMH O SANITARY SEWER MANHOLE TREES: CALIPER IN INGHES $ TYPE: • G-GEDAR, P-PINE, FR-FRUIT 12F 12FR F-FIR, UP -UNKNOWN DEGIDUOUS P OVERHEAD POWER LINE CITY OF RENTON SURVEY CONTROL LOT 10 CONTROL MON 57 3" FLAT BRASS DISC WITH "X" AND A PUNCH MARK O1 CONCRETE POST AT TAX PARCEL THE CONSTRUCTED INTERSECTION OF N.E. 12TH STREET AND EDMONDS AVENUE 559205-0100 NE CONTROL MON 71 TOP OF 2 1 /2" BRASS DISK SET IN CONCRETE MONUMENT 11-8 S AND 9' EAST OF THE INTERSECTION OF NE 12TH STREET AND ABERDEEN AVENUE NE SITE DATA: 0. TAX PARCEL/PLAT NUMBERPROJECT : 3343902566 MONTEREY HEIGHTS b. ADDRESS(ES): 1909 NE 14TH ST RENTON, WA. 98056 VOL. 194, PIGS. 50-52 C. SITE AREA: 11,960 SF OR 0.28 ACRES d. DISTURBED AREA 11,000 SF OR 0.25 ACRES) e. GROSS IMPERVIOUS AREA 6,009 SF OR 0.14 ACRES) LOT 9 f. NET NEW IMPERVIOUS AREA 6,009 SF OR 0.14 ACRES g. IMPERVIOUS SURFACE COVERAGE BASED ON GROSS IMPERVIOUS AREA: 50.4% TAX PARCEL h. BUILDING COVERAGEBUILDING SIZES: 4,930 SF 559205-0090 i. PARKING COUNT VEHICLE: 8-TOTAL (4-DRIVEWAY AND 4-GARAGE) AND 4-BICYCLE GARAGE i. ZONING: R-8(CITY OF RENTON k. MAX BLDG NUMBER OF STORIES: 2 I. MAX WALL PLATE HEIGHT: 24' M. MAX BLDG LOT COV'G: 50% n. MAX. IMPERVIOUS SURFACE: 65% 0. SETBACKS MIN FRONT SETBACK: 20' MIN REAR SETBACK: 20' MIN SIDE SETBACK: 5' The Java n Short Plat, File LUA18 0204, as dep ieted in Each ihit 2, is a Ppmved a Ind is su bjeot to t he fo I Iowi ng con d ition5: 1- Th e app ka Int shal I .provi de er iden ce tD th a Durre nit Pla nn i ng P reject Manager that the exi sti ng si ngle- farni[V residence o n th a prope rty has bee n re moved p rime to su ben itti ng th a Ii na I short p lat docu rn ent for recording_ 2. Th a app licarrt shal I provi de a joint use d riveway with a sing le cu rb cut onto N E 14th St. Th e j e i rat u-se d riveway sha II be s hown on the civil constru ction pI ans to be remewed and app roved by th e Cu rrent LEGEND P la nn i ng Proj ect Man alter prior to i 5sua nce of the co nstructio In perm rt. 3 _ Th a app Iiea rrt shal I subm it a ma p w th the civi I eonstru- tion pe rrrtit application that id entifies a safe C 1 COVER SHEET walki ng route from th a su bj ect p ro peFW to McKn fight M icild le School and th a two bras sto ps for C2 EXISTING SITE CONDITIONS C2 SWWP PLAN Ken nyda le EI emr-e IntarV a€1 d Haze n H igh_ Any sale walking ga ps alo ng the route sha I I be i rr p roared by :Ise C4 UTILITY AND GRADING PLAN app IFca nt. The ma p an d any n eeded i Imp revernents sh a I I be reviewed a Ind a p proved by the Cu rrent C5 N E 14TH STREET PLAN Pla Inn i ng Prej ect Man alter prior to issua nce of the civi I eon struct ion pe rrr it. C 6 DETAILS REVISED PER CITY REVIEW RAD 4-2-19 RAD SURVEYED: RECORD DRAWINGS RAD 12/3/20 DESIGNED: R. DECCIO DRAWN: LR CHECKED: R. DECCIO REVISION BY DATE I APPR APPROVED: R. DECCIO C7 DETAILS C8 NOTES L1 LANDSCAPE PLAN SCALE: VERTICAL: NAVD 1988 • HORIZONTAL: NAD 1983/1991 CITY OF 1"=20 =� RENTON ONE INCH DATUM AT FULL SCALE Planning Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY M.1� xu��1�11411�i1r* krs.a�sn i _ 4 16, �Y T ME LANVIF41) 1 h5r L mAirig r r�i irl- ctjariim >; drwl io 5 VICINITY MAP PARCEL NUMBER 33431 f02566 SITE ADDRESS 1909 NE 14TH ST RENTON, WA. 98056 LEGAL DESCRIPTION nAll" - hPICHLA I THE EAST 104 FEET OF THE NORTH HALF OF TRACT 268, C. D. HILLMAN'S LAKE WASHINGTON GARDEN OF EDEN DIVISION NO. 4, ACCORDING TO THE PLAT RECORDED IN VOLUME 11 OF PLATS, PAGE 82, IN KING COUNTY, WASHINGTON; EXCEPT THE SOUTH 141 FEET THEREOF; AND EXCEPT THE NORTH 20 FEET FOR ROAD UNDER RECORDING NUMBER 6660998. LOT "A" IMPERVIOUS COV'G LOT AREA: 5,980SF ROOF AREA: 2,465SF DRIVEWAYS, PATIOS & WALKS: 520SF TOTAL IMPERVIOUS AREA 2,985SF LOT "B" IMPERVIOUS COV'G "" ^' `^' 5,980 SF ROOF AREA: 2,464SF DRIVEWAYS, PATIOS & WALKS: 460SF a TOTAL IMPERVIOUS AREA 3,024SF J a RECORD DRAWINGS 12-3-20 R-40521 1 1 -J IN COMPLIANCE WITH CITY OF RENTON STANDARDS N I— Z W a C J W > AVON DEVELOPMENT 2 LOT DATE: 4-2-19 W Q PAGE: OOK: PAGE: SHORT PLAT O DRAWING NO: R-405201 > COVER SHEET a SHEET: 1 OF' 9 M GENERAL NOTES N Lid The General Contractor is to provide subgrades 4" below hard surfaces plus/minus .l foot. p g 0 All rough grading shall be positive, draining away from all structures. O � All stones larger than 1.5" diameter shall be removed from the growing medium. 0 LU Topsoil shall be placed at a minimum depth of 6" in all lawn and bed areas. Topsoil shall be tilled into the existing subgrade to eliminate soil interface problems. All bed areas to receive 2" of fine ground fir or hemlock bark, composition mulches are not an acceptable alternative. Trees and shrubs are to be planted at a depth 3/4" higher than the level that they were grown in the Nursery. QBark mulch is not to be placed above the root crown. J All plants shall at least conform to the minimum standard established by the American Association of nurserymen. �I Lawn areas are to be hydroseeded per manufacturer's specifications, or equivalent. Remove all stones - W T_ W O larger than 1" from lawn areas. 3 \\ = Equivalent plant material substitutions may be allowed with prior approval by the Landscape Architect. \ V J \ 3 Z If the site work is different than shown on the Landscape Plan, or poor soils and debris are discovered, O requiring changes to the Landscape Plan, contact the Landscape Architect for instruction. �\ i The Landscape Contractor is responsible for maintaining the landscape during installation, until final \ Q acceptance by the owner's representative. \I I: 6+58.55 / The Landscape Contractor shall warranty all materials and workmanship for a period of one year, from the time of final acceptance. / / During the warranty period, the Landscape Contractor will not be responsible for plant death caused by / unusual climatic conditions, vandalism, theft, fire, or poor maintenance practices. The Landscape �CEL / Architect shall have sole authority to determine the cause of death. 2565 / i Plant counts provided are estimates only. contractor is responsible for calculating all final area and Counts. EXl,'TI G RESIDENCE TO BE'RWED 2� IRRIGATION ASSESSMENT J All proposed plants have naturalized to the Pacific Northwest. Once, established irrigation will not be required. For the first growing season, temporary irrigation by means of hand watering truck shall be provided by the developer. Landscape areas shall be watered 3 times a week during the months of June -September. If there is an unusually dry summer, watering days may need to be increased by 1 or 2 days. MINIMUM TREE DENSITY Two (2) significant trees or two (2) new trees for every five thousand (5,000) sf of lot area. Lot A . (5,980/5000) x 2= 2 Required Trees 2 Trees Provided Lot B : (5,980/5000) x 2= 2 Required Trees 2 Trees Provided LANDSCAPE PLANTING SCHEDULE TREES SW 1/4 OF SE 1/4 OF SEC. 5, TWP. 23 N., RNG. 5 E., W.M CITY OF RENTON, STATE OF WASHINGTON SD 11 \W W W W W W\ W W \W W W 7•\ W W W1 W— \ 3 \ \ 14 TH S TR EE T \\ R.O.W. LANDSC\,PING S S �S s S\S XW 89`43 "W 5 c W �`W W .W N$9'4349 W 5197*1 W ° �., . 6.3' p EEO) R /W .. 2.45 10' FIR TAGGf-- w a — a L •.. LAN DSCA cB •°w l .. B . \. . . 3: a• • • L - RIM 274.49 INV=271.59 (12" v �oI10' ♦� AINAGI=' TILITY' ASEME T. w L -------- - A. I�._- A. I I� a EX. HOUSE TAX PARCEL m LOT "B" 334390-2566 TO I z I LOT\ "A" \ w M Z-30' INGRESS 8c UTILITY \ EASEMENT RC NO \ I I\ 5380145 M \ I \ EXISTING SHRUBS \ \ \\ J I \ \PTO BE REMOVED \ \ M \ m I \ I� m \ \ \ I \ 20' BSBL 20' BSBTING SHED L n \ I \ \ 3E REMOVED I A I SH \ \ 68 N89'43' "W 51.92' SYMBOL QTY BOTANICAL / COMMON NAME SIZE CONDITION 1 Chamaecyparis nootkatensis Pendula / WEEPING ALASKA CEDAR 6'-8' HT. B&B. (2" CAL.) 2 Pyrus calleryana 'Chanticleer' / FLOWERING CHANTICLEER PEAR 2" CAL. B&B. 3 Amelanchier grandiflora Autumn Brilliance' / SERVICEBERRY 2" CAL. B&B. SHRUBS SYMBOL QTY BOTANICAL / COMMON NAME SIZE CONDITION 0 5 Nandina domestics 'Gulf Stream' / GULF STREAM HEAVENLY BAMBOO 2 GAL. CON. GRWN., 3 O.C. 8 Prunus laurocerasus `Otto Luyken' / 'OTTO LUYKEN' LAUREL 2 GAL. CON. GRWN., 3' O.C. 9 Spires x bumolda 'Goldflome' / GOLDFLAME SPIREA 2 GAL. CON. GRWN., 3' O.C. O 5 Ilex crenoto 'Convexa' / DWARF JAPANESE HOLLY 2 GAL. CON. GRWN., 5' O.C. GROUND COVER SYMBOL QTY BOTANICAL / COMMON NAME SIZE CONDITION JJJJJJJJJJJJ * Arctostaphylos uva—ursi / KINNIKINICK 4" POTS CON. GRWN 12" O.C. JJJJJJJJJJJJ JJJJJJJJJJJJ , * Hydroseed lawn * CONTRACTOR TO DETERMINE PLANT COUNT NEED TO ACHEIVE 90% COVERAGE IN 3 YEARS. EXISTING HEDGE TO BE REMOVED N89'43'49"W 51.92' \ \ N 0 20' 40' INSTALL GROUNDCOVERS AS SPECIFIED 2D D I � I INSTALL FERTILIZERS PER MANUFACTURERS RECOMMENDATIONS TOP DRESSING FERTILIZER AS SPECIFIED TYPICAL FINISHED GRA W/ 2 LAYER SPECIFIED MULCH. VERIFY SAUCE I,GC� �'.��►v��::.r�s/c�� ::r�r7L�; I, ��C� ��Illi%�'�i:�r`n:►1%`� �i111i�111i%� �;��►v��::.r�s/c�� ::r�ri1.�; r i7il� =��i.�►`�:r�s"��i111��11 SCALE: NTS 1 SITE PLAN CHANGES N0. REVISION PLAN VIEW OF SPACING SURVEYED: DESIGNED: KL DRAWN: KL 77 4 11 19 CHECKEDKL BY DATE APPR APPROVED: KL BACKFILL WITH EXIST SOIL. IF UNSUITA SOIL IS FOUND, CONT LANDSCAPE ARCHITI FINISH GR, NOTE: DRIVE STAKES UNTIL FIRM IN GROUND TO SUPPORT TREE. TREE STAKING SCALE: NTS INSTALL 1"ABOVE CONTAINER DEPTH PLACE 2" LAYER OF SPECIFIED MULCH OVER PLANTING BED. BACKFILL PLANTING PIT WITH SPECIFIED MIX OF NATIVE AND IMPORTED SOIL. MOUND CENTER OF PLANTING PIT COMPACT TO SUBGRADE DENSITY. SHRUB PLANTING SCALE: NTS 1 /2 SPACING DISTANCE SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM t m NE 16111 St N s t n m HE 14th St 'hole a Audio on Inn & SeattleFRen N CHAINLOCK TREE TIE 12" BVC ROUND STAKES SET ITSIDE ROOTBALL EMOVE AFTER ONE YEAR.) .RK MULCH 2" DEPTH !EP CLEAR OF TRUNK BASE I. BERM/WATER BASIN 1T AND REMOVE TWINE ID BURLAP FROM TOP ID SIDES OF ROOTBALL. EMOVE ALL WIRE SKETS.) MPACTED NATIVE SOIL REMOVE UNTREATED BURLAP FROM TIP 1 /3 OF ROOTBALL. REMOVE TREATED BURLAP OR WIRE BASKETS COMPLETELY. CONTAINER PLANTS -SCORE ROOTBALLS IN 3 PLACES TO 1 /2" DEPTH. TOP DRESSING FERTILIZER, SEE SPECIFICATION. PROVIDE WATER SAUCER. FINISH GRADE OF SOIL. PLANT TABS. QUANTITY ACCORDING TO MANUFACTURER'S SPECIFICATIONS. • CITY OF RENTON PIG nning/Building/Public Works Dept. 19 m HE 16th St a m ae g � D D 2 Y ry 2 m m Northeast 14th Street & Lincoln... NE 141h St A z o m VICINITY MAP NTS ORIGIN 1031 185TH AVE NE SNOHOMISH, WA 98290 TEL: 425.346.1905 �� ba STATE OF WASHINGTON LICENSED LANDSCAPE ARCHITECT KRYSTAL LOWE LICENCE NO. 1206 APPROVALS CITY OF RENTON DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT EXAMINED AND APPROVED THIS DAY OF 9 20--, X X X X X X I X X u X X X X X X X Q J X X X X X X X X CITY OF RENTON ADMINISTRATOR ~ Q R-40521 0 IN COMPLIANCE WITH CITY OF RENTON STANDARDS ~ O 2 Z O Q AVON SHORT PLAT 12-4-17 FIELDBOOK: PAGE: LANDSCAPE -PLAN DRAWING N0: 17-177 SHEET: OF: L1 OF1 a J CL H O U) H O J CV H Z W 2 CL O J W W 0 Z O a � I EX CB SW 1 /4 OF SE 1 /4 OF SEC. 5, TWP. 23 N., RNG. 5 E., W.M. 263.83 NIV=262.53 (12" CONC-E) CITY OF RENTON, STATE OF WASHINGTON 0 INV=259.23 (12 CONC-W) EXIST CB# 3 AB qt RIM = 261.19 AB IE = 259.69 12 DI MM INSTALL 5" STORZ ADAPTER ON Q (E) IE = 259.57 12" PVC W NEW CB# 2 TYPE 1 AB EXISTING FIRE HYDRANT PUMPER PORT (W) RIM = 263.83 AB wX CB3 \� IE = 261.79 12" DI (S) IE INTO EX B \ \ IE - 261.61 12" PVC (E) ST53.31 OFFSET: 20.46 L ITH NEW 12 PIPE IIE = 261.41 12" DI (W) J I I I SD SD I I 37 LF 12" DI S= 4.65% AB 11 VERIFY INVERTS PRIOR TO CONSTRUCTION 1 \ / - AND I !E3 0 - I W \ - W - W W \ W W T W W- W -�W W W W -- W p" \ I USE CDF BACKFILL ON (N) 12" DI PIPE FOR ANY _ I 3 \SEGMENTS WITH LESS THAN 1 FOOT OF COVER CD II \\ \ 34 L.F. 12" DI S= -2.29% OI 3 \ \' I \ II \7+00 STA: �\+10.50 16' J 3 I \ CONC DRIVEWAY � - �� N T \ \\ S S s s s S/ S s S S f-S ` S S S s s s S Z LJJ T3 / \\, �, le - 3 1 m CD c\I J CB #1 TYPE 1 W _ STA 6+60 13FT` T > RIM 4� f 264.69 AB W IE=2N50 (12"DI WIPE NW) 261.01 0 IE=2�`S._0 (8"HDPErS) 261.09 Z PRIVATE I \0 17 LF 8" HDPE S=16.46 % Q D DRAIN / RIM 5.9 / IE=263. 61 "HD�E E 0 IE = 263.10 HDPE N N TAX r SDCB PRIVATE 33439 RIM = 265.96 AB IE = 262.51 8" ADS (N) IE = 262.56 6" PVC (E) SD STUB AB I E = 262.53 6" PVC (S) IE 262.36 WEX� TjN0 5-LF m TO 5E`O\lD Z H W 2 Qg w OII­ i O ♦_ J O X W W W W W W W \ W W W W W( W W ICE 14 TH TREE T \\ \ \ \ 8+ \ \ s s S \s S S s s S\ s HE -USE I ° °� ° 0 5E R MO\/ED EXIST WM I �� WM m 5' CONC S-WALK a I a w ° ° CO u a N I &� LF _6" HDPE S=3. 0% w \ 5 ° I -_ P IVATE a - 10' ®AINAG_' - _TILITY ASEMENT �w AIM- DROAIN \ - xi I `�� I N IE=265. 6"HOPE ° I NOT INSTALLED AB �O' 555E ° \ ° I 2 555L � I \ Fl CONNE TION ` (SEE DETAIL SHEET 7) M INAT IN 51�T I \� SEPARATION FROM PROPERTY IIINE AND BUILDING (TYP) TO BE SIDED LO� "A" AND LOCATED AT TIME OF RESIDENTIAL PERMIT APPLICATION EX. HOUSE -A I `� TAX PARCEL ts) 334390-2566 LOT "B" \I \ 1 \ \ \ I 1 II 1 \ I 1 \ i L - - - - 1 \ ICI I \ I EXISTINO SHED I `\ � SH TO 5E FEN10\/EDI \ \ 68 I I \ - I M'1 SAZEI DESIGN GROUP, LLC 6608 110TH AVE. N. E. KIRKLAND, WA. 98033 TEL. (425) 212-2280 FAX. (425) 889-6887 I I \ I I \ �I �I 20' S55L I 20' 555L v 0I 1 IREVISED PER CI T> 1, 1 RECORD DRAWINGS N0. 1 STA+62.45 \ \ EX CB _ \ RIM 274.49 INV=271.59 (12' REMOVE CURB AND SIDEWALK AT NEAqE-ST-,JOINT AND MATCH CUR LINE. REVIEW RAD 4-2-14 RAD SURVEYED: RAD 2 3 20 DESIGNED: R. DECC10 DRAWN: LR CHECKED: R. DECCIO REVISION BY DATE APPR APPROVED: R. DECCIO SCALE: 1 "= 20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY GRAPHIC SCALE 10 0 5 10 20 LEGEND GASED MONUMENT (OGGUPIED 10/I(b) • EXISTING CORNER AS DESCRIBED 6WOOD FENGE (UNLESS OTHERWISE NOTED) � 450.0 SPOT ELEVATION P o POWER POLE HYD6_ HYDRANT w A WATER VALVE w ® WATER METER PM® POWER METER ® GATGH BASIN SSMH O SANITARY SEWER MANHOLE TREES: CALIPER IN INGHES TYPE: • G-GEDAR, P-PINE, FR-FRUIT 12F 12FR F-FIR, UD-UNKNOWN DEGIDUOUS P OVERHEAD POWER LINE VERTICAL: NAVD 1988 • HORIZONTAL: NAD 1983/1991 CITY OF URI RENTON DATU M • Planning/Building/Public Works Dept. it 0 co H R-405214 ° IN COMPLIANCE WITH CITY OF RENTON STANDARDS N H Z W 2/� LL 0 W AVON DEVELOPMENT 2 LOT DATE:4-8-19 W FIELDBOOK: SHORT PLAT PAGE: DRAWING N0: R-40520 4 0 0 UTILITY AND GRADING SHEET: 4 OF: 9 RECORD DRAWINGS 12-3-20 FOR EX CB RIM 261.23 INV-260.13 (8" CONC-E) INV=259.73 (12" CONC-W) I W Z W z Q ® EX CB RIM 263.83 U INV=262.53 (12" CONC-E) INV=259.23 (12" CONC-W) \ SD 1 S�1 SD I SD- SD S, 3 I 6+1p0 I \ ISTA: 6+58.55 I SILT FENCE (SEE DETAIL SHEET 6)- TAX PARCEL 334390-2565 / i EXISTING RESI>% TO BERENIOVE I I LIMITS OF\PISTURBANCI 1 \ 1 \ 1 \ I \� EXISTING SHED \ TO BE REMOVED \ l I 0 N 0 N i � O X s CO N O p N 0 �o Qz w �X co SW 1/4 OF SE 1/4 OF SEC. 5, TWP. 23 N., RNG. 5 E., W.M. CITY OF RENTON, STATE OF WASHINGTON W W W W - \ 3 \ \7+00 A \I N99"43"4W W 51.92I \ SLOT 5 TAX PARCEL 559205-2568 LINCOLN PLACE SHORT PLAT REC. NO. 2016020900007 SAZEI DESIGN GROUP, LLC 6608 110TH AVE. N.E. KIRKLAND, WA. 98033 TEL. (425) 212-2280 FAX. (425) 889-6887 LOT 6 TAX PARCEL \ \ 559205-2563 14TH STREET \\ s� -S S S\ (SEE DETAIL SHEET 6) W 0 F­30' INGRESS & UTILITY EASEMENT RC NO MONTEREY HEIGHTS 5380145 VOL. 194, PGS. 50-52 \SILT FENCE (SEE DETAIL SHEET 6) LOT 9 TAX PARCEL 559205-0090 LIMITS OF DISTURBANCE LOT 8 �\\ TAX PARCEL kwAijim REVISED PER CITY REVIEW RECORD DRAWINGS 12-3-20 N0. I REVISION I \ S ¢ S �S LEGEND CA5ED MONUMENT (OCCUPIED 10/16) • EXISTING GORNER AS DESCRIBED 6WOOD FENCE (UNLESS OTHERWISE NOTED) SPOT ELEVATION PP POWER POLE H YD6_ HYDRANT WV WATER VALVE W ® WATER METER PM POWER METER ® CATGH BASIN SSMH O SANITARY SEWER MANHOLE TREES: CALIPER IN INCHE5 TYPE: C-CEDAR, P-PINE, FR-FRUIT 12F 12FR F-FIR, UD-UNKNOWN DEGIDUOU5 P OVERHEAD POWER LINE GRAPHIC SCALE 20 0 10 20 40 w z J r w D- 0 O- D- EXISTING GROUND GRADING SLOPE SET BACK (TYP) N TS CALL 2 BUSINESS DAYS BEFORE YOU DIG 1-811-424-555 RAD 4-2-11 RAD SURVEYED: RAD 4-8-1V RAD DESIGNED: R. DECCIO RAD 12/3/20 DRAWN: LR CHECKED: R. DECCIO BY DATE APPR APPROVED: R. DECCIO CONSTRUCTION SEQUENCE EROSION AND SEDIMENT CONTROL RECOMMENDED CONSTRUCTION SEQUENCE 1. PRE -CONSTRUCTION MEETING. 2. POST SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR (MAY BE CONSOLIDATED WITH THE REQUIRED NOTICE OF CONSTRUCTION SIGN). 3. FLAG OR FENCE CLEARING LIMITS. 4. INSTALL CATCH BASIN PROTECTION IF REQUIRED. 5. GRADE AND INSTALL CONSTRUCTION ENTRANCE(S). 6. INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.). 7. CONSTRUCT SEDIMENT PONDS AND TRAPS. 8. GRADE AND STABILIZE CONSTRUCTION ROADS. 9. CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.) SIMULTANEOUSLY WITH CLEARING AND GRADING FOR PROJECT DEVELOPMENT. 10. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL AND MANUFACTURER'S RECOMMENDATIONS. 11. RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY'S EROSION AND SEDIMENT CONTROL STANDARDS. 12. COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAYS DURING THE WET SEASON WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING OR EQUIVALENT. 13. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN SEVEN DAYS. 14. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. 15. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BMPS REMOVED IF APPROPRIATE. THE 13 ELEMENTS OF A CONSTRUCTION SWPPP 1. Preserve Vegetation/Mark Clearing Limits: The clearing limits are indicated on the plan sheet. Furthermore, clearing and grading will be limited to only areas that need to be disturbed for grading/construction of the site and frontage improvements. Construction will require regarding the entire site. Field marking the clearing limits shall be completed prior to clearing and grading activities. BMP's: Preserve Natural Vegetation (VEG) 2. Establish Construction Access: Access to the construction site shall be limited to the rock construction entrance. The rock construction entrance shall be installed off of the Street to provide access to the construction vehicle/equipment staging and employee parking areas. BMP's: Rock construction entrance (CE) See detail sheet C9 3. Control of Flow Rates: Storm water detention: No detention is proposed for the site since the work should be completed in a short period of time. BMP's None Proposed 4. Installation of Sediment Controls: Sediment control will be provided through a combination of filtration through the surround on -site vegetation, or filter fence if required. , BMP's: Silt Fence (SF) Sediment Trap (ST) I 5. Soils Stabilization: Temporary and permanent soil stabilization will be provided. Temporary stabilization will be provided through the application of straw and/or plastic sheeting to exposed, worked earth. From October 1 until April 30, no exposed soil may remain exposed and unworked for more than two days; after May 1, no exposed soil may remain exposed and unworked for more than seven days. BMP's: Straw Covering, Plastic Sheeting, Final Landscaping(as required) 6. Slope Protection: Stock piles shall be protected from erosion through cover and prevention of concentrated surface runoff flows on steep slopes as required. BMP's: Plastic Sheeting, (AS REQUIRED) 7. Protection of Permanent Drain Inlets: Inlet protection will be provided for all catch basins. BMP's: Inlet Protection (IP) See detail sheet (AS REQUIRED) 8. Stabilization of Channels and Outlets: All channel slopes shall be constructed and protected against erosion in accordance with County code. (None Required) 9. Pollutant Control: Pollutants shall be controlled through the on -site BMP's proposed above. 10. Dewatering Control: De -watering: Interception of the water table is expected to occur. (NOT REQUIRED) 11. BMP Maintenance: All BMP's and SWPPP elements shall be inspected daily and maintained as required. 12. Project Management: The project shall be managed in a cooperative effort by the project manager, contractor, engineer, and the county inspector. During the construction process, if unforeseen issues arise that cannot be resolved on site, construction activity (other than SWPPP maintenance) shall be halted and the owner's representative and the project engineer are to be contacted and informed of the situation. TBD 13. Protect on -site stormwater management bmps for runoff from roofs and other hard surface on -site stormwater management bmps used for runoff from roofs and other hard surfaces include: full dispersion, roof downspout full infiltration or dispersion systems, perforated stubout connections, rain gardens, bioretention systems, permeable pavement, sheetflow dispersion, and concentrated flow dispersion. the areas on the site to be used for these bmps shall be protected from siltation and compaction during construction by sequencing the construction in a fashion to install these bmps at the latterpart of the construction grading Q operations, by excluding equipment from the mps and the associated areas, and by using the J erosion and sedimentation control bmps listed below. relevant bmp's bmp c 102: buffer zone NOTE: H CLEARING LIMITS AND SILT FENCE TO BE SET JUST INSIDE OF THE PROPERTY LINES. O TOPSOIL: STOCKPILE EXISTING TOPSOIL DURNING GRADING AND REPLACE IT PRIOR TO PLANTING PER BMP 15.13 OPTION 3. TOPSOIL REQUIRED 500 CYDS RECORD DRAWINGS 12-3-20 SCALE: VERTICAL: NAVD 1988 • HORIZONTAL: NAD 1983/1991 1 "=20' DATUM PRI Nkslv ONE INCH AT FULL SCALE Planning/ IF NOT ONE INCH SCALE ACCORDINGLY CITY OF RENTON uilding/Public Works Dept. H R-405213 ° IN COMPLIANCE WITH CITY OF RENTON STANDARDS CV H Z W O J W W AVON DEVELOPMENT 2 LOT DATE: 4-8-19 Q SHORT PLAT PAGE: OOK: PAGE: DRAWING NO: Z R-405203 > S W W P PLAN SHEET: 3 OF: 9 U J a. O 2 O J CV I- Z W }2 a_ O J W W 110 O Q O CV Ln O MM1 I..L Lf_ MW 5W L Z I- W W V/ Lu C'3 O J I N m O L LLJ Q � I CIL CL O O J J W I o LLJ LLJ � N N Z c � I � X o O x OL X BMP TS.13 Post -Construction Soil Quality and Depth Purpose and Definition Naturally occurring (undisturbed) soil and vegetation provide important stormwater functions including: water infiltration; nutrient, sediment, and pollutant adsorption; sediment and pollutant biofiltrotion; water interflow storage and transmission; and pollutant decomposition. These functions are largely lost when development strips away native soil and vegetation and replaces it with minimal topsoil and sod. Not only are these important stormwater functions lost, but such landscapes themselves become pollution- generating pervious surfaces due to increased use of pesticides, fertilizers and other landscaping and household/industrial chemicals, the concentration of pet wastes, and pollutants that accompany roadside litter. Establishing soil quality and depth regains greater stormwater functions in the post development landscape, provides increased treatment of pollutants and sediments that result from development and habitation, and minimizes the need for some landscaping chemicals, thus reducing pollution through prevention. Applications and Limitations Establishing a minimum soil quality and depth is not the some as preservation of naturally occurring soil and vegetation. However, establishing a minimum soil quality and depth will provide improved on -site management of stormwater flow and water quality. Soil organic matter can be attained through numerous materials such as compost, composted woody material, biosolids, and forest product residuals. It is important that the materials used to meet the soil quality and depth BMP be appropriate and beneficial to the plant cover to be established. Likewise, it is important that imported topsoils improve soil conditions and do not have on excessive percent of clay fines. Design Guidelines 251658240 Soil retention. The duff layer and native topsoil should be retained in an undisturbed state to the maximum extent practicable. In any areas requiring grading remove and stockpile the duff layer and topsoil on site in a designated, controlled area, not adjacent to public resources and critical areas, to be reapplied to other portions of the site where feasible. 251658240 Soil quality All areas subject to clearing and grading that have not been covered by impervious surface, incorporated into a drainage facility or engineered as structural fill or slope shall, at project completion, demonstrate the following: I. A topsoil layer with a minimum organic matter content of ten percent dry weight in planting beds, and 5% organic matter content (based on a loss -on -ignition test) in turf areas, and a pH from 6.0 to 8.0 or matching the pH of the original undisturbed soil. The topsoil layer shall have a minimum depth of eight inches except where tree roots limit the depth of incorporation of amendments needed to meet the criteria. Subsoils below the topsoil layer should be scarified at least 4 inches with some incorporation of the upper material to avoid stratified layers, where feasible. 2. Planting beds must be mulched with 2 inches of organic material Quality of compost and other materials used to meet the organic content requirements: The organic content for -pre-approved" amendment rates can be met only using compost that meets the definition of -composted materials" in WAC 173-350-220. This code is available online at: <http://www.ecy.wo.govlprogromslswfolfacilitiesl350.html> Compost used in bioretention areas should be stable, mature and derived from yard debris, wood waste, or other organic materials that meet the intent of the organic soil amendment specification. Biosolids and manure composts can be higher in bio-available phosphorus than compost derived from yard or plant waste and therefore are not allowed in bioretention areas due to the possibility of exporting bio-available phosphorus in effluent. The compost must also have an organic matter content of 35% to 657, and a carbon to nitrogen ratio below 25:1. The carbon to nitrogen ratio may be as high as 35:1 for plantings composed entirely of plants native to the Puget Sound Lowlands region. Calculated amendment rates may be met through use of composted materials as defined above; or other organic materials amended to meet the carbon to nitrogen ratio requirements, and meeting the contaminant standards of Grade A Compost. The resulting soil should be conducive to the type of vegetation to be established. 251658240 Implementation Options: The soil quality design guidelines listed above can be met by using one of the methods listed below. I.Leave undisturbed native vegetation and soil, and protect from compaction during construction. Amend disturbed soil according to the following procedures: Scarify subsoil to a depth of one foot In planting beds, place three inches of compost and till in to an eight -inch dep th. In turf areas, place two inches of compost and till in to an eight -inch dep th. Apply two to four inches of arborist wood chip, coarse bark mulch, or compost mulch to planting beds after final planting. Alternatively, disturbed soil can be amended on a site -customized manner so that it meets the soil quality criteria set forth above, as determined by a licensed engineer, geologist, landscape architect, or other person as approved by Snohomish County. Stockpile existing topsoil during grading, and replace it prior to planting. Stockpiled topsoil must be amended if needed to meet the organic matter and depth requirements by following the procedures in method (2) above). Import topsoil mix of sufficient organic content and depth to meet the organic matter and depth requirements. More than one method may be used on different portions of the some site. Soil that already meets the depth and organic matter quality standards, and is not compacted, does not need to be amended. Maintenance 251658240 Soil quality and depth should be established toward the end of construction and once established, should be protected from compaction, such as from large machinery use, and from erosion. 251658240 Soil should be planted and mulched after installation. 251658240 Plant debris or its equivalent should be left on the two soil surface to replenish organic matter. DocuSign Envelope ID: 6EEC F5B6-602A-4E4A-8436-A317AA638878 PRIVATE RDOF ORAIN COLLECTOR PIPE; LOT LINE. TYP S' DIA MIN., 6' CIA MIN. ROOF DRAIN PRIVATE TYPE 1 05%MIN. SLOPE. 5' MIN, CATCH BASIN 2 FT MIN. COVER STUB WITH CLEANOUT (TYP.] (TYP, HOUSE FYP.) I I I I I I 3' MIN. io PRIVATE JOINT SD SD SD SD UTILITY EASEMENT CURB, SIDEWALK � CITY STORM DRAIN (SO) SYSTEM S, MIN. WIDTH R.O.W. LINE PRIVgTE STORM DRAIN (SD) SYSTEM, 0' MIN. CIA PIPE, SEE NOTE 1 ROOF DRAIN TO CONNECT INTO Cr3Y CATCH BASIN =C MIN. SIZE TYPE I CLEANOLIT, TYP AT EVERY W. W 2ND AS' DEMO. AND AT 1 ov MAX SPACING ON STRAIGHT SECTIONS NOTES: I. SEE STD. PLANS 4M.00 AND 220.10 FOR PIPE MATERIALS AND MINIMUM COVER REQUIREMENTS. 2. THE ROOF AND FOOTING DRAIN SYSTEMS ARE PRIVATELY MAINTAINED- 5. FLOW PATTERN SHOULD BE TO THE NEAREST CB IF GRADE ALLOWS, OR TO THE NEXT DOWNSTREAM CS 4. ROOF DRAIN COLLECTORS MUST BE ANALYZED FOR CAPACITY. SIZED FOR 2E-YEAR PEAK FLOW. 5. PVC PIPE MUST BE SOR 35OR THI CKER AND MEET THE AEQUI REMENTS OF ASTM DX04, S. PVC PIPE USED IN PRIVATELY MAINTAINED DRAINAGE SYSTEMS MUST BE WHITE IN COLOR. 7, SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. uNIESS OTHE R W SE NOTE D, DRAW I NG IS NOT TO SCALE (NTS] STD. PLAN - 225.00 PUBLICWO K TYPICAL PRIVATE STORM DRAIN 9PROWD ❑ COLLECTION SYSTEM GAZ 9/28/2018 1 :45 A yf �. DATE SAZEI DESIGN GROUP, LLC 6608 110TH AVE. N.E. KIRKLAND, WA. 98033 TEL. (425) 212-2280 FAX. (425) 889-6887 DocuSign Envelope ID: 6EECF5B6-602A4E4A-B436-A317AA638878 EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES - THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE END SION AND SEDIMENT CONTROL (ESC) PLAN SET. ALL THE NOTES ON I HI: LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER. HEREBY REFERRED TO AS APPLICANT. MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER. THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFI[; ASPECTS. THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES. 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE•CONSTRUCT(ON MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2. THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION 5TORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT. 3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS, 4. THE BOUNDARIES OF THE CLEARING LIMITS. SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLANS) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OI RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD. NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REWIRED TD ENSURE THAT ALA, PAVED AREAS ARE KEPT CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OFTHE PROJECT. IF SEDIMENT IS TRACKED OFFSITE. PUBLIC ROADS SHALT. BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER. AS NECESSARY TO PREVENT SEDIMENT FROM ENTERNG WATERS Or THE STATE. 6. WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF -SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON -SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUTAREAS. 7. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING ANDIOR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL EE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING ANDIOR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AF T E I; CONSTRUCTION IS COMPLETED AND THE SITE HAS SEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION MAINTENANCE, REPLACEMENT. ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. S. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY, 9. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE CQURSE OF CONSTRUCTION. IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER OUALITY OF THE RECEIVING DRAINAGE SYSTEM. 10. APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN. SIZE NOR LOCATION OF PIPES. RE5TRICTORS. CHANNELS, OR STORMWATER FACILITIES. 11. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACIU71ES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12. ANY AREAS OF EXPOSED SOILS. INCLUDING ROADWAY EMBANKMENTS. THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON [OCTOBER 1ST THROUGH APRIL 3OTH) OR SEVEN DAYS WRING THE DRY SEASON )MAY IST THROUGH SEPTEMBER 3OTH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G-. SEEDING. MULCHING. PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. 13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY. 14. ANY AREA NEEDING ADDITIONAL ESC MEASURES. NOT REQUIRING IMMEDIATE ATTENTION. SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. 15. THE ESC BMPS ON INACTIVE &TES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MA NTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY. 16. BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216-30 SHALL BE PROVIDED FOR ALL. STORM DRAIN INLETS DOWNSLOPE AND WITHIN 5DO FEET OF A DISTURBED OR CONSTRUCTION AREA. UNLESS THE RUNOFF THAT ENTERSTHE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 213 OF THE CAPACITY OF THE CATCH BASIN SUMP ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT4.ADEN WATER INTO THE DOWNSTREAM SYSTEM 16. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY I$ TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE. THE TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. 19. AREAS DESIGNATED ON THE PLAN(S] CONTAINING EXISTING STORMWATER FACILITIES OR ON -SITE BMPS (AMENDED SOILS. 0110RETENTION, PERMEABLE PAVEMENT. ETC J SHALL BE CLEARLY FENCED AND PROTECTED USING ESC SNIPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION. 20. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SNAIL RE SUBMITTED TO THE CITY FOR RENEW. 21. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVING THE PROJECT SITE ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON -SITE SNIPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM. DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLYAFTER FINAL APPROVAL MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST 22. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTSOF-WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGHTS�OF-WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. STD. PLAN • 268.00 \� PUBLIC WORKS EROSION AND SEDIMENT CONTROL -" DEPARTMENT STANDARD PLAN NOTES GAZ 9/28/201B 1 DATE 12-3-20 ! I N 0. REVISION :45 DocuSign Envelope 10:6EEC F5136.6D2A-4E4A-B4-36-A317AA638878 CONSTRUCTION ENTRANCE NOTES: (yD� 1, DRIVEWAYS SHALL BE PAVED TO 6 THE EDGE OF THE RIGHT-OF-WAY PRIOR TO INSTALLATION OF THE R = 25' MIN. CONSTRUCTION ENTRANCE TO AVOID DAMAGING OF THE ROADWAY. 2. IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD 100' MIN. INSTA LL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT- AS PER CITY ROAD STANDARDS C-B' QUARRY SPALLS GEOTEXTILE 15'MIN. PROVIDE FULL WIDTH OF 1 NGRES&EGR ESS AREA 1Z' MIN. THICKNESS NOTES: 1. CONDITION OF USE 1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1.000 FEET OF THE SITE, I FOR RESIDENTIAL CQNSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUED IVI SION ENTRANCE. STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTHAWIDTH TO PROVIDE VEHICLE AOCESSIPARKI NO, BASED ON LOT SIZEJCONFIGURATION. 2. DESIGN AND INSTALLATION SPECIFICATIONS 21 A SEPARATION GEOTEXTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTEXTILF SHALL MEET THE FOLLOWING STANDARDS: GRAB TENSILE STRENGTH EASTM D46321 200 LBS. MIN, GRAB TENSILE ELONGATION (ASTM D4632) 3C% MAX. (WOVEN) CBR PUNCTURE STRENGTH )ASTM 1)6241I 495 LBS. MIN. ADS (ASTM D4751) 12045IU S- STANDARD SIEVE SIZE) 2.2, DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLCRI DE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE pH LEVELS IN 57ORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROH IBITED. 2.5. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS, THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOO FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT. ,A- FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE. 2.5. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. 3. MAINTENANCE STANDARDS 3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 3.2. IF THE ENTRANCE I S NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING. AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE. OR THE INSTALLATION OF A WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING- THE SEDIMENT COLLECTED BY SWEEPING SHALL 13E REMOVED OR 91AE 11-lab ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT 15 NECESSARY TO WASH THE STREETS, A STALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS. 3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.S- IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 215.10 PUBLIC WORKS PPRDVEP. DEPARTMENT STABILIZED CONSTRUCTION ENTRANCE GAZ 9/28/2018 1 DATE DocLISlgn Envelope ID: 6EECF5B6.602A-4E4A-B436-A317AA638878 5• MAX. DRAINAGE GRATE TRIM GRATE FRAME _ C_ OVERFLOW BYPASS I BELOW INLET GRATE DEVICE SEDIME NT ANO OESRIS d FILTERED WATER SECTION VIEW DRAINAGE GRATE (RECTANGULAR GRATE SHOWN) RETRIEVAL SYSTEM (TYP.I OVERFLOW BYPASS (TYR) BELOW INLET GRATE DEVICE ISOMETRIC VIEW NOTES, I. PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2. IN LET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4. SIZE THE BELOW INLET GRATE DEVICE BIGD FOR THE STORMWATER STRUCTURE IT WILL SERVICE [ 1 E. 5. THE BIGD SHALL HAVE ABUILT4N HIGH•F LOW RELIEF SYSTEM {OVERFLOW BYPASS). 6. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7, PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 6-01,3f 15). 8. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY UNLESS OTHERWISE NOTED, DRAWING G NOT TO SCALE (NTS} STD. PLAN - 216.30 FRPUBLIC WORKS APPR a : DEPARTMENT CATCH BASIN INSERT GAZ 9/28/2018 1 ­�­m DATE ID 4-2-11 RAD SURVEYED: DESIGNED: R. DECCIO DRAWN: LR CHECKED: R. DECCIO BY I DATE I APPR APPROVED: R. DECCIO :45 A :45 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 Z-:2" 14 GAUGE WIRE. OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC 2' MIN I -----------J�--.: 6 MAX. I I ! ! POSTSPRCINGMAY BE INCREASED � I awl MIN. TRENCH 12, MIN - TO W IF WIRE BACKING IS USED ! 1-1 ILLLJJJI BACKFILL TRENCH WITH NATIVE SOIL QR 3A4' TO 1-1rr WASHED GRAVEL 27H' WOOD POSTS, STEEL FENCE POSTS. OR EQUIVALENT LIYR. NOTES: L CONDTTIONSOFUSE 1 I. SILT FENCE MAY BE USED DOWN SLOPE OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT iNTENDEC TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE ORUNAGE SYSTEM TO A SEDIMENT TRAP OR POND, 2. DESIITN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. AOS (ASTM D4751) 301-100 SIEVE SIZE C0.60.0.15rt 1 FOR SILT FILM 50,100 SIEVE SIZE (0.30-0.15-1 FOR OTHER FAD RICE WATER PERMITTIVITY (ASTM D4491) (102 SEC'' MINIMUM GRAD TENSILE STRENGTH (ASTM 04632) 18100LBS MIN. FOR EXTRA STRENGTH FABRIC 0LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM Q49n) 3D%MAIL (WOVEN) ULTRAVIOLET RESISTANCE (ASTM 04355) 70%MIN. 22. STANDARD STRENGTH FABRIC REQUIRES WLRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY RE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS ASTRONGER FENCE 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 21d,1V 2A. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4-X4- TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM S INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 2.5. FILTER FABRIC FENCES SHALL BE INSTALLED ALCN(3 CONTGURS WHENEVER PCSSIBLE. I MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 3,2. IF OONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE PENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND, 3.3, IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR 5IONS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNEL IZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS. REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT. 3A. SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 61NCHES HIGH. 3-5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAXDOWN, IT SHALL BE REPLACED. UNLESS OTHERWISE NOTE D. PRAW1W I3 NOT TO SCALE [NISI STD. PLAN - 214.00 ��I\ DEPARTMENT PUBLIC WORKS SILT FENCE GAZ 9/28/20188 I DATE 57 518" 30119, FRONT VIEW vitalT,1 Cluster Box Unit - Type I SIDE VIEW :45 �l 1 r` 4" 28112" PEDESTAL 1a 1 i' PEDESTAL BASE BOLT PATTERN DOOR CHART Pd011 TIT!I VWNWNWC;NTxwlpm] NOTES: ID'PARCEL 10.114x1 &13116" 1 a' FAAIIccE1 13.3Tax12.1371 e 1. This unit is approved far LISPS and private applications. MWsFSEt OILMOINGSLOT�.kll_VC 2. Decorative mailbox accessories sold separately and are LISPS Approved vital CLUSTER BOX 11NCf products. 3. Pedestal should be installed with included Rudder Pad; riT-r� T� MODB 157H "E A mounting hardware not included. refer to installation manual for jj((�L�' j1��EEVreaommendativns. AF mdR pppD NINE 9151N201 �� 4. Florence 'Fseries CBU is Officially Licensed by LISPS: 5935 Corporate Drive r MQnhotian, IN 66503 "`v NGNIA BER Dxww"e License#CDSEO-08-B-0012 www,florencennoilboxes.com ■ (80D) 275-1747 1570-BC5 AFD A CI INDUSTRIES COMPANY RECORD DRAWINGS 12-3-20 _ R4 21 05 6 I SCALE: VERTICAL: NAVD 1988 • HORIZONTAL: NAD 1983/1991 1 "=20' DATUM PRI Nkslv ONE INCH AT FULL SCALE Planning/ IF NOT ONE INCH SCALE ACCORDINGLY CITY OF RENTON uilding/Public Works Dept. IN COMPLIANCE WITH CITY OF RENTON STANDARDS AVON DEVELOPMENT 2 LOT SHORT PLAT DATE: 4-2-19 PAGE: R-405206 SHEET: 6 OF: 9 J F- I� O �2 V / F- O J CV F- Z 5W L O J W W 0 Z O Q J H O 2 H O J N 6 3 I EX. SEWER MAIN - PROPERTY Mtn _ __ _ _ SPOOL (LENGTH AS NEEDED) ? s" SEWER STUBS FUTURE 4' SIDE SEWER / y 2"x 4" STUD MARKING POST PANTED I SEWER MAIN TEE X E" TEE 8' CAP) WHITE WITH THE WORD "SEWER" STENCILED IN 3" HIGH BLACK LETTERS AND #6 WIRE w I WRAPPED AROUND THE STUD AND - EXTENDED TO THE TOP OF THE STUD. COUPLING (TYP.) a I I f 0 AD AD' SURFACE CLEANOUT WITH CAST IRON RING AND COVER I (EAST JORDAN IRON WORKS PRODUCT NO. 00367502 OR ' APPROVED EQUAL, SPECIFY "SEWER' ON LID), (SEE STD. PLAN 403.1 FOR INSTALLATION) I r �_-------- - --------------------- -�r�.A ------- JM EAGLE THREADED CLEAN -OUT ADAPTER HUB u^ -J BEND AS J & PLUG (OR APPROVED EQUAL) REQUIRED EXISTING SANITARY SEWER MAIN --2.Ox MIN. SLOP FUTURE 4" SIRE SEWER 6" SEWER STUB 6"x6'X6' WYE FUTURE E"K 4" REDUCER SEWER MAIN SIZE X E" TEE EMSTING SEWER MAIN A. VITRIFIED CLAY MAIN - CUT IN A NEW PVC 'TEE" USING 'STRONG -BACK' FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B, CONCRETE MAIN - CUT IN A NEW PVC 'TEE" USING "STRONG -BACK' FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL), C. PVC & C90o PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL), D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED. t 3000 PSI MIX NCRETE BLOCKING P- 1`' _a0 t2d( Z7L IAIIJ j%QPE 6„ HORIIONTAL TEE 6" MIN. SEWER SEWER MAIN MAIN CONCRETE 81 OCKINC ANGLE TYPICAL SIDE SEWER Of TEE AT MAIN FIFTWEEN 25* AND 45' NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. STANDARD SIDE SEWER STD. PLAN - 406.1 APP VEO. • PUBLIC WORKS INSTALLATION DEPARTMENT O SEWER MAIN TO PROPERTY LINE) VARIES: 4.5' MIN. LANE LINE MARKING SAWCUT AFTER BACKFILL DEPTH OF EXISTING PAVEMENT 2" 6" HMA (SEE NOTE 2) EDGE OF PAVEMENT, EDGE J OF CURB & GUTTER, OR MIN. MIN. CENTER OF LANE MARKING 2" HMA (SEE NOTE 2) 6" CRUSHED SURFACING TOP COURSE (CSTC) (9-03.9(3)) PER WSDOT STANDARD 2" SAWCUT AND REMOVE SPECIFCATIONS, COMPACTED TO 95% OR PLANE, SEAL WITH MODIFIED PROCTOR AR-40DOW CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03-19). GRAVEL BORROW (9-03-14(1)) PER WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GEOTECH REPORT, COMPACTED TO WIDTH OF TRENCH AS REQUIRED BY SIZE OF 0 95% MODIFIED PROCTOR, PROPOSED IMPROVEMENT (SEE WSDCr STANDARD SPECIFICATION 2-09.4) PLUS AN PIPE ZONE BEDDING MATERIAL AND COMPACTION AS ALLOWANCE FOR ANY SHORING. SHORING, IF REQUIRED BY THE WSDOT STANDARD SPECIFICATIONS NEEDED, SHALL MEET THE REQUIREMENTS OF FOR THE TYPE OF IMPROVEMENT INSTALLED, EXCEPT: WSDOT STANDARD SPECIFICATION 7-08.3(1)8 �� e FOR STORM AND WATER PIPE, PER STD PLAN 220.0 F FOR SANITARY SEWER, PER STU PLAN 405 TRENCH WIDTH " FOR JOINT UTILITY TRENCH, SAND WITH 95% PASSING A #4 SIEVE AND LESS THAN 5% PASSING A #200 SIEVE NOTES: I. WHEN EXISTING S G PAVEMENT IN A AN REQUIRING LANE EQU NG A FULL WIDTH REPLACEMENT IS BROKEN 0R DETERIORATED TO A A F' VEMENT CONDITION INDEX 7 R ❑ DE RATING OF O 0 LESS, THE EXISTING PAVEMENT IN THAT LANE, AND FOR THAT DISTANCE SO CLASSIFlED, SHALL BE REMOVED AND REPLACED WITH HMA MATCHING THE DEPTH USED IN THE EXISTING STREET OR THE DEPTH PER CITY STANDARD, WHICHEVER IS GREATER. 2, PRINCIPAL/ MINOR/COLLECTOR, ARTERIAL, & INDUSTRIAL ACCESS STREETS - MATERIAL AND THICKNESS SHALL BE HMA CL PG 64-22 AND MATCH EXISTING THICKNESS AND IN NO CASE LESS THAN 6". RESIDENTIAL ACCESS STREETS -- HMA CL J" PG 64-22, THE THICKNESS SHALL BE THAT OF THE EXISTING PAVEMENT SECTION AND IN NO CASE LESS THAN 4"_ 3. WHEN THE "SAWCUT AFTER BACKFILL" ENCROACHES INTO AN ADJACENT LANE, CURB & GUTTER OR SHOULDER, THE AFFECTED LANE SHALL BE PLANED AND OVERLAID WITH HMA FULL WIDTH, THE CURB & GUTTER SHALL BE REMOVED AND REPLACED, OR THE SHOULDER SHALL BE PLANED OR REMOVED AND OVERLAID WITH HMA. 4. IF TRENCH UNDERMINES EXISTING SIDEWALK AND/OR CURBS, THEN THE SIDEWALK AND/OR CURB SHALL BE REPLACED FROM EXPANSION JOINT TO EXPANSION JOINT. 5, IF TRENCHING THROUGH EXISTING DRIVEWAY OR SIDEWALK RAMP, THE DRIVEWAY OR SIDEWALK RAMP SHALL BE REPLACED TO MEET ADA STANDARDS. TYPICAL LONGITUDINAL PATCH PLAN - 110'1 PUBLIC WORKS FOR FLEXIBLE PAVEMENT OR f' 'I� � Till DEPARTMENT RIGID PAVEMENT WITH OVERLAY A i SAZEI DESIGN GROUP, LLC 6608 110TH AVE. N.E. KIRKLAND, WA. 98033 TEL. (425) 212-2280 FAX. (425) 889-6887 r RAISED EDGE DETAIL W LEVEL �{ 1,r EXTEND SIDEWALK TRA}N[SVERSE r-C' v-0, „d- P,4 p it JOWTS TO u C9AI'X RNSED EOGE AIL; DING r 1•ll- f.= gtyaYL • ' SEE IllD EDGE r-tr sLDeWALK DETAA-TFR3a,. ALLCUF 1 NR lrrrrgR [ryPX FORCUPBETAIS SUVGDAN101 09 -,yL SEE Sra PLAN 3Ct I 1rr LIh1 R r"P.1 1 �-� 111'PF1AL u' sloEx'Aex L41TH RAISED EDGE 1'&' [INl PRE40EDED JOI NT FIIlE R FYPlcAL wTffiAE APPI%JABLe FORCURO to TARS SEE am RAN 101 AICSVNG ROAOLS•AY : ' CIL+a$HEDAOCKOASI WED SUPfAC1NO TOP COURSE Sr STCI I fO 95% y.'Xa•FIEi1 NRGI,1Cw 4 REOVRELeN1 WAAtD 9Y EERI TYRGU. UNDER AIL CURB R A SIDEWALJL OM TINDER a, GUTTER TO IRS E•T1H704IE&5 ON 1011P1M0 ROADWAY CRVSHCII ROCK IMNIE iEVER IS GREATER TIYP FOR 1Ra & GJrrm FI XISHED GRA[lE S-pNI6EtOM1V TOPOFCOINCRFTE RFACE t-g, SIDEWALK ADJACENT TO CURB r. tr r •!r NIN Flea D NG IQ' IINI R fT+•P I FOR CURA DETAILS 12D'R 1 Iy 131'. SEE STO F1lVH let rr s. ir'rf BRIDGE OR PEDESTRIAN RAKLNO tH ADJACENT TO CURE FOR CURS OVALS BARNitR.eCC sTDEWALx SEE ST.7 PLAN 101 15 TEE PFlL SI OF£51 RALHI^ ALL OR BARR'FR IIII 1rr ftNj R ITTP I KOLl7A[X rLusN ssx lrr N1 R 5[ VER}Ix sf OT04 ' EiN• 'i 31r.=Ny20TRLo'D JOLYTFRLfp1y ADJACENT TO CURB AND RAILING OR WALL vRSruycnEG JOuIYT nuum F O R 51GE NLWFER STRIP "ILATMENT StIIEWAix SEDEAYAL K ADJACENT TO WALL DETAIL SIDEWALK DENOTE 1a1 SCG7-DNS T L t;1L fR ROR CURB ANDETAU w: &1L 1.ANa !FE BID PLAN 10 T '�• .1 BRppAICD FINISH OR MATCH C]05t1F1G . 1RO EELED�PCw6 5'•d TLR FIwsIEncRACE ORPLANUAG-FOSHIFPA[TE sLHiFAA:E FOR PLJUJTlf:G - FLU SH I E pRl•>:O CEMENT CONCRETLCURR icwn AND GUTTER 5,Ia#VM ADJACENT TO BUFFER STRIP r ~: FOR Cufm DETALS SEE ST4 PLAN - If Sol r_r ' f x 11S TD v4• NOTES ` f I. Fact fret of BIo sidewalk W1d'JI &twA be the nlinlrrum poguxuUn :CC" 00lepte I'�GIe of 1A7MI end hdnsontal ab Anucnions. GraBngl, Accm Corers, JuncW Some, Cable emmc Pull Nn LI and othepath . fth D1e sldewrM TIUStlQ nUSk3 SU must ha fNJah wlD1 wrfLlpD. and ma1G1 grade of the zk*wak 2. MMp1iI Nr Ce"m Cpnvete Cw4 and SI40-1L Is not oar nlned In new Far other referenced NOTE$ see tanitlurlian. When Teplacemerrt work STO PLAN 104.2. nC[lShcLAleS ■ Mpnollth[C Cement CDALTete Curb build per WSDOT Stanclam Pion F-30 1043 Paved Surfaces must Comply wish 3 Co ele b bt 4,DDG PSI, S70 PLAN 102-1 as applicable • PUBLIC WORKS DEPARTMENT caXTnADT1ONIxwrr • r • ,an . pE 9l0EWNJIONlY �� f.1 � e ••. ' FULL -DEPTH S 06450I JOINT w NOTH = I CURS AND SIDFNALK C1Rt S10 FLAN IOLLJ sw C CONTRACTFDN JOINT JOINT AND FINISH DETAIL . s .. JOUIT FILLER E FULL-0Q0FTH EWANSrON JOINT STI) PLAN - 102 CEMENT CONCRETE F .i SIDEWALK � o I LAPrE } LANE I. I I' I { �.. INITIAL 2" DEEP SAWCUT OR GRIND, AND II LIMIT OF FINAL OVERLAY, GRIND AND PAVE j { I } rF r FULL STREET WIDTH OVERLAY REQUIRED. I r , I J 9 K F { 1 f+II r. [ 1 rr I f { I+ [ I [ EDGE OF EXISTING PAVEMENT I I. EDGE OF TRAVELED LANE (EDGE STRIPE) I I / L.. r VARIES: 4.5' MIN. SEE STD PLAN 11 ( 110.1) r / I CENTER OF ANY MAWFO LANE LINE, PROVIDE NEW CHANNELIZATION I AFTER OVERLAY r' I SECONDARY FULL DEPTH SAWCUT FOR r I PROPOSED TRENCH I. INITIAL 2" DEEP SAWCUT OR GRIND, AND LIMIT OF FINAL OVERLAY. AND PAVE FULL STREET WIDTH OVERLCAYNREQUIRED LANE LANE LANE T AND NOTES SEE STANDARD PLAN FOR TYPICAL SECTION 110.1 STD. PLAN - 110.2 !� PUBLIC WORKS REQUIRED SAWCUT, GRIND AND l'I'l�' i;11 DEPARTMENT OVERLAY FOR LONGITUDINAL TRENCHES /0.� 13"x24' PLASTIC METER BOX EQUAL TO MID -STATES PLASTIC, INC. BCF SERIES MSBCF 1324-18 WWTH 1.75' THICK DUCTILE IRON DIAMOND PLATE COVER EQUAL TO MID -STATES PLASTICS. INC. MSCBC-1324-R WITH READER LID AND 2" DRILLED HOLE FOR TOUCHREAD FIT LID (SEE DETAIL A -A) 3F" MIN COVER NEW DUCTILE IRON ,NATERMAIN 9' MIN 12" MAX FINISH GRADE E N 04 22-1 /2' CITY �IVATi PIPIJ6 PIPING IIN UNIMPROVED RIGHT OF ? WAY INSTALL METER BOX AT J PROPERTY LINE WITH 12' LONG COPPER TAILPIECE, w I SIDEWALK $ 1 FTOUCHREAD WATER METER TO BE --1J 12' SUPPLIED BY E THE z x C CITY TYPE "K" SOFT o COPPER TUBING v f IF SERVICE LINE TO HOUSE IS TO BE INSTALLED IN THE FUTURE INSTALL FORD C14-33 OR 44 FIPT x COMPRESSION COUPLING LLOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVIDE SLACK IN COPPER COPPERSETTER FOR 5/8"x3/4" METER: FORD SERVICE LINE TO METER. VSH72-15W-44-33G, OR WOONALD BRASS: 21-215WCQU33, OR MUELLER: 3/4-8--2470-2 WITH ANGLE BALL VALVE ON INLET AND SINGLE CHECK VALVE ON OUTLET CORPORATION STOP WITH BALL VALVE. FORD COPPERSfTT£R FOR i" MFTFR: FORD V13H72-15W-44--44G, OR TAPERED THREAD (CC). QUICK JOINT McDONALD BRASS 21-415WC0044, OR MUELLER, 1-13-2470-2 (3/4" FB1000-3-Q) OR AY MCDONALD 4701E BOTH INLET AND OUTLET WITH QUICK JOINT. PADLOCK WINGS ON (1" 1`131000-4-0) OR AY MCDONALD 4701E INLET ANGLE $ALL VALVE AND SINGLE CHECK VALVE ON OUTLET, ALL FITTINGS 5HALL BE WITH QUICK JOINT, NOTE. ALL METER BOXES INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST-IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUSH BE INSTALLED ON BOTH SIDES OF METER BOX. A = KILL 2 - UTA, HULL F ❑K AMK LAU 1 LIMA I IC IETER READ) TOUCHREAD DEVICE 2-1/2" MIN. FROM NEAREST AND FRONT EDGE OF PIT LID THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN ONE RM 3/4" OR 1 GALVANIZED PLUG PUBLIC WORKS 34" AND 1 " WATER SERVICE STD. PLAN - 320.1 + + I]I PARTMENT n NOVEMBER 2009 VARIES: 4.5' MIN. LANE LINE MARKING SAWCUT AFTER BACKFILL DEPTH OF EXISTING PAVEMENT G" HMA (SEE NOTE 2) EDGE OF PAVEMENT, EpGEJ OF CURB & GUTTER, OR MIN. MIN. CENTER OF LANE MARKING 2" HMA (SEE NOTE 2) 6" CRUSHED SURFACING TOP COURSE (CSTC) (9-03.9(3)) PER WSDOT STANDARD 2" SAWCUT AND REMOVE SPECIFICATIONS, COMPACTED TO 957 OR PLANE, SEAL WITH MODIFIED PROCTOR AR-4000W CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL (9--03.19), GRAVEL BORROW (9-03.14(1)) PER WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GEOTECH REPORT, COMPACTED TO WIDTH OF TRENCH AS REQUIRED BY SIZE OF0 95% MODIFIED PROCTOR. PROPOSED IMPROVEMENT (SEE WSOOT STANDARD SPECIFICATION 2-09.4) PLUS AN PIPE ZONE BEDDING MATERIAL AND COMPACTION AS ALLOWANCE FOR ANY SHORING. SHORING, IF REQUIRED BY THE WSDOT STANDARD SPECIFICATIONS NEEDED, SHALL MEET THE REQUIREMENTS OF FOR THE TYPE OF IMPROVEMENT INSTALLED, EXCEPT: WSOOT STANDARD SPECIFICATION 7-08.3(1)B L I * FOR STORM AND WATER PIPE, PER STD PLAN 220.0 * FOR SANITARY SEWER, PER STD PLAN 405 TRENCH WIDTH * FOR JOINT UTILITY TRENCH, SAND WITH 95% PASSING A #4 SIEVE AND LESS THAN 5% PASSING A #200 SIEVE NOTES 1. WHEN EXISTING PAVEMENT IN A LANE REQUIRING A FULL WIDTH REPLACEMENT 15 BROKEN OR DETERIORATED TO A PAVEMENT N CONDITION INDEX RATING OF 70 OR LESS, THE EXISTING PAVEMENT IN THAT LANE, AND FOR THAT DISTANCE SO CLASSIFIED, SHALL BE REMOVED AND REPLACED WITH HMA MATCHING THE DEPTH USED IN THE EXISTING STREET OR THE DEPTH PER CITY STANDARD, WHICHEVER IS GREATER. 2. PRINCIPAL/ MINOR/COLLECTOR. ARTERIAL, & INDUSTRIAL ACCESS STREETS -- MATERIAL AND THICKNESS SHALL SE HMA CL 4." PG 64-22 AND MATCH EXISTING THICKNESS AND IN NO CASE LESS THAN 6". RESIDENTIAL ACCESS STREETS - HMA CL E }' PG 54-22, THE THICKNSS SHALL 8E THAT OF THE EXISTING PAVEMENT SECTION AND IN NO CASE LESS THAN 4". 3. WHEN THE "SAWCUT AFTER BACKFILL" ENCROACHES INTO AN ADJACENT LANE, CURB & GUTTER OR SHOULDER, THE AFFECTED LANE SHALL BE PLANED AND OVERLAID WITH HMA FULL WIDTH, THE CURB & GUTTER SHALL BE REMOVED AND REPLACED, OR THE SHOULDER SHALL BE PLANED OR REMOVED AND OVERLAID WITH HMA. 4. 1F TRENCH UNDERMINES EXISTING SIDEWALK AND/OR CURBS, THEN THE SIDEWALK AND/OR CURB SHALL BE REPLACED FROM EXPANSION JOINT TO EXPANSION JOINT. 5- IF TRENCHING THROUGH EXISTING DRIVEWAY OR SIDEWALK RAMP, THE ORIVEWAY OR SIDEWALK RAMP SHALL BE REPLACED TO MEET ADA STANDARDS. TYPICAL LONGITUDINAL PATCH' PLAN- 110.1 PUBLIC WORKS FOR FLEXIBLE PAVEMENT OR < 1'1J DEPARTMENT RIGID PAVEMENT WITH OVERLAYRMA" o A. a 9 REVISED PER CITY REVIEW RAD 4-2-11 RAD SURVEYED: P�F WAS�F ° y�ycc� RECORD DRAWINGS RAD 12 3 20 DESIGNED: oo R. DECCIO Z DRAWN: 4 LR 25693 �4v FS F�l STERF G� CHECKED: I►.sAnA-A1 F_�F R. DECCIO 12-3-20 N0. REVISION BY DATE APPR APPROVED: R. DECCIO SCALE: VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 1 "=20' PRI ONE INCH DATU M AT FULL SCALE Planning/ IF NOT ONE INCH SCALE ACCORDINGLY DocuSign Envelope ID: 6EECF5B&6U2A-4E4A-B436-A317AA638876 SEE STANDARD PLANS 110. 110.1. 1102. AND 111 FOR PAVEMENT RESTORATION REQUIREMENTS SURFACE RESTORATION AS , SPECIFIED IN CONTRACT DOCUMENTS 72" MIN EXISTING PAVEMENT SURFACE --�- ---- ------- 5' MIN. , SEE NOTE 4 NEATLINETRENCH 'CRUSHED SURFACING TOP COURSE" PER WSDOT STD. SPEC 9.03.9p). COMPACTED v O TG 95% OF MAXIMUM DENSITY Q Q CRUSHED SURFACING TOP COURSE" PER WSDOT STD. SPEC 9-03-9(3X, "BANK RUN f GRAVEL FOR TRENCH BACKFILL' PER WSDOT STD. SPEC 9.03.19, OR "GRAVEL BORROW PER WSDOT STO. SPEC 9-07,14(1), COMPACTED TO OF MAXIMUM DENSITY 95% :.� v fl BENCH AS NEEDED FOR SHORING SYSTEM WHEN DEPTH IS 4' OR GREATER I PIPE PIPE ZONE BEDDING AND BACKFILL j PER STO. PLANS 220.00 AND 220,11) !I �- SEE NOTE 1 UNPAVED AREAS PAVED AREAS I NQTIES: 1. SEE WSDOTIAPWA STANDARD SPECIFICATIONS SECTION 2-09A FOR MEASUREMENT OF TRENCH WIDTH. 2. EXCAVATIONS OVER a' DEEP SHALL COMPLY WITH THE SAFETY STANDARD OF SCRI BED IN CHAPTER 2WISS PART N OF THE WAD. 3. MAXIMUM BACKFILL DEPTH ABOVE PIPE SHALL NOT BE EXCEEDED, AS DETERMINED BY PIPE MANUFACTURER, 4. IN PAVED AREAS. IF PIPE HIS LESS THAN 3' OF COVER. USE "CRUSHED SURFACING TOP COURSE' FOR THE ENTIRE EACKFILL DEPTH ABOVE PIPE ZONE. 5. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE [NTS} STD. PLAN - 220.20 P 120 PUBLIC WORKS �• TYPICAL TRENCH AND BACKFILL GAZ 9/28/2018 :45 A �11 DEPARTMENT vw.w.a wm..•wI. DA1t '--cuSign Envelope ID: 6EEC:F5B6-602A-4E4A-6436-A317AA638878 CONFIGURATION ON SLOPING GROUND - DOWNSPOUT' WITH CLEMiOuT FILTER, SEA ❑ETAIL CLEAMW PER STD. PLAN 226WO 10 MIN, LEVEL TRENCH NRTH PERFORATED PIPE, SEE NOTE 1 s• MIN. 5, MIN-- 4 I � I CL_EANdIT PER � STD. PLAN 7!&AO I ro $TORN GRAIN SYSTEM I - - - - - - - - - - - - N BYPASSI FOOTING DRAI- I 5 5, MINCLEIWOUT PER . MIN. I M. FLAX 2tgpO I TO STORM DRAIN SY$TEM I Fr EA SEE DETAIL 10 MIN. LEVEL TRENCH WITH J� PERFORATED PIPE. SEE NOTE 1 1 - - - - - - - - - - - - - - - - - - - -� CONFIGURATION ON FLAT GROUND PLAN VIEW OF PARCEL COMPACTED TOPSOK OR OTHER CLEAN FILL NONAMDVEN GEOTE> LE FOR$WARATION S'MIN. PVC ON TOP AND SIDES OF TRENCH PER WSDOT PERFORATED PIPE SPECIFICATIONS SECTION 990.2(1)TASLE 3 PER ASTPA D1765 saLro 6 MIN. n \ FRIER 9CLiE tra 1q-MIH. I v2,-aw wASHEO ORAIN ROCK 7S TO GROUND 24 MIN. TYPICAL DOWNSPOUT UNLxgTUREEDRATTYE SOIL MIN. T AeDV E SEA.$pNAL XIGX FILTER DETAIL GROUNDWATER TASLE SECTION A kDTESF I. TRENCH LENGTH TOME W FEET IN LENGTH FOR EVERY 5,DW SF OF CONTRIBUTING IMPERVIOUS SURFACE, OR 35,000 SF OF NON-NATIVE PERVIOUS SURFACE, OR PORTION THEREOF. GENERAL NOTIE$1 I. 1NF1 T M F RUNOFF •F Y P XH M T LIRA IONOODING EC U RED TO LINO FROM SINGLE L OR aU ES OR O CONTROL DEPARTMENT GU BASEMENT FLOOOTNO. CONSULT WA DEPARTMFM OF ECOLOGY ftEGU[AilONS FOR UNDERGROUND WJECTKII R D CONTROL PROGRAM IULCI FOR OTHER TYPES OF RUNOFF MANAGEMENT. 2. MPERVIM5 AREAS LARGER THAN 10,0W SF AND NONE TIVE PEWK)US AREA$ LARGER THAN a5M SF MAY REQUIRE LARGER PIPE AND SHOULD BE DESIGNED BY CIVIL ENGINEER g. THE PERFORATED PIPE LAAY NOTBE PLACED INACRITICAL AREA SUFFEROR ON SLOPE55TEEpER THAN 1111 4. 3EE CONSTRICTION PLANS FOR SPEGFIC PROJECT PEi!IU1REMENTS. UNLESS OTHERW NOTED, DRAWING IS NOT TO S[AIE [NTSI PUBLIC WORKS PERFORATED STUB -OUT STD. PLAN - 263.40 'PP D `-i� DEPARTMENT [QNNECTI�N GAZ 9/28/2018 j :45 A DAIS CITY OF RENTON uilding/Public Works Dept. R-405217 IN COMPLIANCE WITH CITY OF RENTON STANDARDS AVON DEVELOPMENT 2 LOT SHORT PLAT DETAILS DATE: 4-2-19 PAGE: R-405207 SHEET: 7 OF: 9 LQ f= .s O � N ~ N O ii CI:: Q g 3 6FE1r M2 /B•R X 5/S"O 9u MLIY JOINT - SEE NUT E2 - 2 - D• I 1 I 3/8` PRET,fOLDED JpNT FILLER {TYPj- CEM7:HTGOtY.REIE CURB AND B VTTFR 5' PLAN MEW ME C R3 FRME A GRATE 6 1 2' T3- L FRAME AND GFIATE - NOT NCLUDED 1 /2- K• 1' R. MANY IN CURa AND nUTTER BID ITEM BLOPE • ' h 3' `4 i TCPOF e . I• R. 1 1r ROADWAY 9 F 5 P -••,• P AWUSTMENT SECTION -NOTMICLUDED ►• h' or CURB AND BUTTER BID OEM nJSTCH 9A62Y • NOT 1Nd-UDED v IN OWW AND OUTTERSIDREM r •h __. r= SECTION I(D f� l GENERAL NOTES: 1, The intent Df this design Is to facilitate the removal of a catch basin with minimal dlsiurbanoe of the curb. 2. The expanal on Jo[nts of the adjaounteldwmikstealI ,; •�j��;` •�' :I be -adjusted to be In Una with these curb expansion Joints. ISO! RT2E31C VIEW CEMENT CONCRETE CURB' + + PusliC WORKS INSTALLATION AT PF20 +.D: DEPARTMENT CATCH BASINS DIAG DocuSign Envelope 10: 6EECF5B6.602A-4E4A-B436-A317AA638878 I J i Ol1TFALL iO STHEAM I DIfNP RD PC,L LIIiAHES I BOLT -DOWN SLOT. SEE DETAIL AND AIL t TOP 31B- RECESSED LETTERING I I 4102'- I � i•� �i 1 1r4' I 1II ae• I �I I BOLT -DOWN SLOT DETAIL 1- - - - SEE NOTE I - S ISOMETRIC 24' 7 OR 8 EQUAL SPACES j DIRECTION FLOW I 518• MAX- T SECTION A NOTES: 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES. GRATES AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5t8'-1INC x rALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2. REFER TO STANDARD SPECIFICATION 9-05.15(2)FOR ADDITIONAL REQUIREMENTS. 3. FOR FRAME DETAILS. SEE STANDARD PLAN 204.130. UNLESS OTHERWISE NOTED, ORAVANG 1S NOTTO SCALE (NT51 STD. PLAN - 204.20 AaFftL ff*&jMj& PUBLIC WORKS RECTANGULAR VANED GRATE -+ DEPARTMENT GAZ 9/28/2018 IrtxwM..mn,nnNw DATE :45 A' SAZEI DESIGN GROUP, LLC 6608 110TH AVE. N.E. KIRKLAND, WA. 98033 TEL. (425) 212-2280 FAX. (425) 889-6887 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 SANDBAG i7YP.) 10, MAX., _ -- ---- TOE IN SHEETING IN 4' x 4' MIN. TRENCH _ I Oi MAX I I I �Il I I It PROVIDE ENERGY DISSIPATION A7 7pE IF EROSION IS l,]KELY NOTES: 1. CONDITIONS OF USE 1.1. PLASTIC COVERING MAY BE USED ON DISTURBED AREAS THAT REQUIRE COVER MEASURES FOR LESS THAN 30 DAYS. 12. PLASTIC IS PARTICULARLY USEFUL FOR PROTECTING CUT AND FILL SLOPES AND STOCKPILES 1.3- CLEAR PLASTIC SHEETING MAYBE USED OVER NEWLY -SEEDED AREAS TO CREATE A GREENHOUSE EFFECT AND ENCOURAGE GRASS GROWTH. CLEAR PLASTIC SHOULD NOT BE USED FOR THIS PURPOSE DURING THE SUMMER MONTHS. 1 4. THIS METHOD SHALL NOT BE USED UPSLOPE OF AREAS THAT MIGHT BE ADVERSELY IMPACTED BY RUNOFF. SUCH AREAS INCLUDE STEEP AND UNSTABLE SLOPES, 2. DESIGN AND INSTALLATION SPECIFICATIONS 21. PLASTIC SHEETING SHOULD HAVE A MINIMUM THICKNESS OF GAS MILOMETERS. 2.2. IF EROSION AT THE TOE OF ASLOPE IS LIKELY, A GRAVEL BERM. RIPRAP, OR OTHER SUITABLE PROTECTION SHALL BE INSTALLED AT THE TOE OF THE SLOPE IN ORDER TO REDUCE THE VELOCITY OF RUNOFF. 2.3. TIRES, SAND BAGS. OR EQUIVALENT MAY BE USED TO WEIGHT PLASTIC. 2.4. SEAMS BETWEEN SHEETS MUST OVERLAP A MINIMUM OF 12 INCHES AND BE WEIGHTED OR TAPED. 3. MAINTENANCE STANDARDS 3.1. TORN SHEETS MUST BE REPLACED AND OPEN SEAMS REPAIRED. 3.2, IF THE PLASTIC BEGINS TO DETERIORATE DUE TO ULTRAVIOLET RADIATION, IT MUST BE COMPLETELY REMOVED AND REPLACED 3.3. WHEN THE PLASTIC IS NO LONGER HE EOED, R SHALL BE COMPLETELY REMOVED. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE IN TS) STD. PLAN - 213.30 a . PUBLIC WORKS DEPARTMENT PLASTIC COVERINGPRD GAZ 9/28/2018 1 :4S A DocuSign Envelope ID: 6EECF586-602A-4E4A-B436-A317AA638878 Imo. TRENCH WIDTH, SEE NOTE 3 PIPE ZONE 6Fnn,nir_ ex,n RACKFILL. BE FOUNC LEVEL r FOUNDATION MATERIAL, 1 IF REQUIRED, SEE NOTE 5 �kL CIRCULAR PIPE PIPE ZONE BEDDING AND SACNFILL. SEE NOTE 4 - FOUNDATION LEVEL RIGIO PIPE NOTESi 1 PIPE COMPACTION LIMITS SHOWN ON THIS PLAN ARE FOR PIPE CONSTRUCTION IN AN EMBANKMENT. FOR PIPE CONSTRUCTION IN A TRENCH, THE HORIZO NTAL LIMITS OF THE PIPE COMPACTION ZONE SHALL BE THE WALLS OF THE TRENCH. 2. 0.D IS EQUAL TO THE OUTSIDE DIAMETER OF A PIPE OR THE OUTSIDE SPAN OF PIPE -ARCH. 3, SEE STANDARD WS DOTIAPWA SPECIFICATIONS SECTION 2.09.4 FOR TRENCH WIDTH. 4, PIPE ZONE BE DOING AND BACKFILL MATERIAL SHALL SE PLACED I N 6• LOOSE LAYERS AND COMPACTED TO 95% MAXIMUM DENSITY 5- EXCAVATE UNSTABLE MATERIAL DOWN TO FIRM SOIL AND REPLACE WITH FOUNDATION MATERIAL CLASS A ORB PER STANDARD WSDOTIAPWA SPECIFICATIONS SECTION 9-03.17, ®GRAVEL BACKFILL FOR PIPE ZONE BEDDING IWSDOT 9-03 12(3)) OR MAINTENANCE ROCK (WSDDT 9.03.9(4)) TRENCH WIDTH, SEE NOTE 3 SPAN S' 7 RISE FOUNDATION MATERIAL. IF REQUIRED, SEE NOTE 5 PIPE - ARCH MINIMUM ALLOWED IN ZONE 1 PIPE TYPE COVER (FT) PUBLIC? PRIVATE? OF THE APA? CORRUGATED 20 YES YES YES STEEL PIPE SPIRAL RIB STEEL 2.0 YES YES YES PIPE PLAIN CONCRETE PIPE (PCP) 2 D NO YES ND REINFORCED CONCRETE PIPE 1.0 YES YES NO (RCP) CORRUGATEDOR SPIRAL RIB 2.0 YES YES NO ALUMINUM PIPE DUCTILE IRON PIPE 1.0 YES YES YF: CIRCULAR PIPE DIAMETER MINIMUM DISTANCE BETWEEN BARRELS 1r TO 24' 12' 30" TO 96' ❑IAM ETER 13 102" TO 186" 48" PIPE -ARCH SPAN MINIMUM DISTANCE BETWEEN BARRELS 18" TO 36, 12" 43' TO 142' SPAN 13 148" TO 199' 48" UNLESSOTIIEAWISE NOTED, rIAAWING ISNOT TOSCALE [NTS) STD. PLAN - 220.00 PUBLIC WORKS PIPE ZONE BEDDING AND APPR [D 0 DEPARTMENT COMPACTION -RIGID PIPE GAZ 9/28/2018 I DATE 12-3-20 I1►0 REVISION :45 Al' DocuSign Envelope ID: 6EECF5B6-602A-4E4A-8436-A317AA638878 - 29 114' RECESSED ALLEN HEAD CAP SCREW W-11 NCxr ORATE BOLT -DOWN HOLE (TYP.) - WE. 11 NG, SEE DETAIL AND NOTE Z ` 25 f74' � A PUNS D SECTION BOLT•DOWN DETAIL SEE NOTE 2 TOP 24 1 W <> I 1 ' qz SECTION A SEE DETAIL ISOMETRIC VIEW f \ 7r8 ` 116' �aw r 1IM' ,I NOTES: 1 . THIS IS ACCOMMODATE0OR COVERS, 4 1 2' SEE STANDE AND 209 dO.�TE3 ARD PlAN3 204.10.20420 204 1` �J 1 y8• 2. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES. GRATES, AND I 1 ' COVERS. UNLESS OTHERWISE SPEC F ED PROVIDE HOLES N THE THAT ARE VERTICALLY WITH THE OR GRATE 1 ISM, FRAME ALIGNED GRATE COVER $LOT$. LOTHE FRAME SHALL ACCEPT THE "'-11 KC X 2'ALLrCATION CAP BY BE NG TAPPED. OR OTHER APPROVED MECHANISM- BOLT -DOWN HOLES VARIES BY MANUFACTVRER. 2 1R' 3. REFER TO STANDARD SPECIFICATION 945.15[2) FOR ADDITIONAL \ DETAIL % REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) STD. PLAN - 204.OD ► PUBLIC WORKS DEPARTMENT RECTANGULAR FRAME O GAZ 9/28/2018 l :45NCIINAF :. DATE DocuSign Envelope ID: 6EECF58"02A-4E4A-B436-A317AA638878 I SEE STANDARD PLANS 110. 110.1. 110.2, AND I I I FOR PAVEMENT RESTORATION REQUIREMENTS SURFACE RESTORATION AS , Ar SPECIFIED IN CONTRACT DOCUMENTS I 1Z' MIN. EXISTING PAVEMENT SURFACE I / -- r\ tr MIN.. SEE NOTE 4 �ORK!" O D NEAT LINE TRENCH "CRUSHED SURFACING TOP COURSE' PER WSOOT STD- SPEC 9.03.9(3). COMPACTED TO 95% OF MAXIMUM DENSITY 1J • "CRUSHED SURFACING TOP COURSE' PER WSDOT STD. SPEC 9.03.9(3). -BANK RUN GRAVEL FOR TRENCH BACKFILL' PER IX p d WSDOTSTO SPEC 9.03.T9,OR-GRAVEL \ BORROW PER VdSDOTSTD. SPEC 9-0314(1). Xl< COMPACTED TO 95% OF MAXIMUM DENSITY v a BENCH AS NEEDED FOR SHORING SYSTEM WHEN DEPTH IS 4' OR GREATER PIPE PIPE ZONE BEDDING AND BACKFILL PER STD. PLANS 220-00 AND 220,10 �- SEE NOTE 1 UNPAVED AREAS I PAVED AREAS I NOTES: 1. SEE WSDOPAPWA STANDARD SPECIFICATIONS SECTION 2-09.4 FOR MEASUREMENT OF TRENCH WIDTH. 2. EXCAVATIONS OVER 4' DEEP SHALL COMPLY WITH THE SAFETY STANDARD DESCRIBED IN CHAPTER 2WI55 PART N OF THE WAD. 3. MAXIMUM BACKFILL DEPTH ABOVE PIPE SHALL NOT BE EXCEEDED, AS DETERMINED BY PIPE MANUFACTURER. 4. IN PAVED AREAS, IF PIPE HAS LESS THAN X OF COVER. USE 'CRUSHED SURFACING TOP COURSE' FOR THE ENTIRE BACKFILL DEPTH ABOVE PIPE ZONE. 5 SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) STD. PLAN - 220.20 � PUBLIC WORKS D TYPICAL TRENCH AND BACKFILL GAZ 9/28/2018 :45 A -lO DEPARTMENT ILu. Wu.lo.d,%n,awam. + '•Tr ID 4-2-11 RAD SURVEYED: D •T ^f 3 '0 DESIGNED: R. DECCIO DRAWN: LR CHECKED: R. DECCIO BY DATE APPR APPROVED: R. DECCIO SCALE: VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 1 "=20' ONE INCH DATUM AT FULL SCALE Planning/ IF NOT ONE INCH SCALE ACCORDINGLY DocuSign Envelope ID: 6EECF506-602A-4E4A-B436-A317AA638878 FRAME AND VANED GRATE a,. 17.OR 24- ONE $13 BAR HOOP FOR W HEIGHT INC REMENT ISPACED EQUALLY). SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION r� •Lii • e 43 BAR EACH CORNER I I� , J{ 43 BAR EACH SIDE `Y T - 73 BAR EACH WAY PRECAST BASE SECTION 43 BAR HOOP 113 BAR EACH CORNER 18- M IN. SEE NOTE 1 ALTERNATIVE PRECAST RASE SECTION a PUBLIC WORKS DEPARTMENT Ir- PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REIN FORCED OR PLAIN 12. CONCRETE ALL METAL PIPE Is, CPSSP', 12• STD. SPEC. 9-05,m SCUD WALL PVC. STD. SPEC. 9-05.120) 15, PROFILE WALL PVC, STD. SPEC. S•05.12(2)I 15, 'CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1 AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN EN THE PRECAST BASE SECTION. FIBERS IPLACED rN ACCORDANCE WITH STANDARD SPECIFICATION 805.5019p. OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SEC TON. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2 THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20- KNOCKOUTS SHALL HAVE A WALL THICKNESS OF Y MINIMUM TO Z.S MAXIMUM. PROVIDE A 1.5' MINIMUM GAP BETWEEk THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFrCAYION!}04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN 5- THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT ABATE OF 1H:24V OR STEEPER 6. THE OPENING SHALL BE N,EASURECAT THETOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION S-20.N2}. B ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9.04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9 MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE 8Y TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH, 11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE INTS,. STD. PLAN - 200.00 APP 0: CATCH BASIN TYPE 1 GAZ 9/28/2018 1 DATE » OU �E+J �NCL ACES S,OE �tx R,urS - Fb+ v.PiES ME nl t 3F'E%�AH31W AM ITS • ;LR pL1 r4Y+IDr ? � ftix� , ��� i6F Sip N W LOT, C6.FjR %] .•.. L ,/� y iLF Igrc S l t I. r 1 x=. �7 m � 11 • roesrR_c1w.ILa.I* xc NOTE, uwneolrrAEtt RN! 4RR1 ILL l^ 4imElEY►j IrCORWRICTpIgNI L1EE sm xLAN wa - FLAN VEW [rfLE C3S WM. C1 A C2 i C-Mu SIV_W (sEE NOTE III r iI4L%7'J -' _ - xri WA wt Ktte lRTH 1 ��v..w ._�1••..�->r-^'--rt,rw pL�weaFeoorsEou,�Fn- lrEE+.wWlrw-m., _ _ _-- tELfIb1 O � � v "'"1�iErn►1 41oE+n�k nlRlx ,no.reu+raN raa rx- � r r � �- Fu NOTES gm STD PLAN 104.2 STD. PLAN - 104.4 * lB3 t PUI31-IC WORKS CEMENT CONCRETE DRIVEWAY Pf'R t 1: R3 �4 AEPAYSEHT C3B. and C-MAXB WITI'ti BUFF -En EY CITY OF RENTON uilding/Public Works Dept. G•ey I�mmerman, Pul]I+c walLl Adm:n11[r LSvr :45 Al R-405218 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CM Z 5W AG Ili O J W DATE: AVON DEVELOPMENT 2 LOT 4-2-19 0 SHORT PLAT PAGE:FIELDOOK: PAGE: Z DRAWING NO: O R-405208 > DETAILS SHEET: OF: L0 O 1 O 1 0 W I- I- ^J (L O J CV I- Z W 2 O J W W 0 Z \O � � g DocuSlgn Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER. HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS. THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES, 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT. AND THE APPLICANTS CONTRACTOR. 2. THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION. 3. ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD. BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY, 4. APPROVAL OF THE ROAD. GRADING. PARKING, BUILDING. AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER. SEWER, GAS, ELECTRICAL. ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS. AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. 5. A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANTS CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN. AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS -BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICT EXISTS. 7. VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH). UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS- 8. ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER SECTION 2-03.3(14)D - COMPACTION AND MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS. ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY. 9. OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS. 10. ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES. CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. 11. ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CITY, 12. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL. AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE- ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 220.10, AND 220.20. 13. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2. OR S INSIDE AND OUTSIDE, 14. ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT -LOCKING LIDS PER THE CITY STANDARD PLAN 204.10. 204.20 . 204.30. AND 204.50. STRUCTURES SHALL HAVE: • RECTANGULAR OR ROUND. SOLID LIDS WHEN NOT COLLECTING RUNOFF. AND OUTSIDE OF THE ROADWAY. • ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURBIGUTTER LINE. • ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 15. BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM. 16. LIDS OF MANHOLESICATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/CATCH BASIN RIMS SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN. 17. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH, UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 267.00 PUBLIC WORKS SURFACE WATER STANDARD PLAN PP! D: 9/28/2018 I -1 N AF DEPARTMENT NOTES (1 OF 2) GAZ nbrt Wan. Mm,mm,mr PAi f DocuSign Envelope ID: 6EECF5B6-602A4E4A-B436-A317AA638878 SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER. THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 18. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1 } FOOT AND SHALL MEET THE FOLLOWING SPECIFICATIONS: • 4.8 INCH ROCK 140.70% PASSING; • 2 -4 INCH ROCK 130 - 40% PASSING: AND • LESS THAN 2 INCH ROCK 110 - 20% PASSING. 19. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE. UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BMPS. 20. THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED "STORM" SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00. 21. ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION. 22. ALL NEWLY-INSTALLEO AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS AN01OR PAVEMENT. 23. ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04-3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED. 24. FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 264.00. 25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION ANDIOR LIABILITY CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION. 26. ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH. AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY. 27. PROJECTS LOCATED WITHIN THE CITY'S AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT 46 OF THE RENTON SWOM AND AQUIFER PROTECTION REGULATIONS (RMC 4-3-06% 28. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASINIMANHOLE LIDS, CLEAN OUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NONSLIP OR NONSKID LID PER ADA REQUIREMENTS. 29. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT. 30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM. 31. CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1.000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE,. THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS (E. G.PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE {NTS} STD. PLAN - 267.10 SURFACE WATER STANDARD PLAN APPRMD: NOTES (2 OF 2) GAZ 9/28/2018 1 DATE SAZEI DESIGN GROUP, LLC 6608 110TH AVE. N.E. KIRKLAND, WA. 98033 TEL. (425) 212-2280 FAX. (425) 889-6887 : 4 S A� :45 Al SW 1 /4 OF SE 1 /4 OF SEC. 5, TWP. 23 N., RNG. 5 E., W.M. CITY OF RENTON, STATE OF WASHINGTON CITY OF RENTON STANDARDS All materials and workmanship shall be in accordance with the City of Renton Standard and Supplemental Specifications (current adopted version) except where otherwise noted in these standards. Materials and workmanship are required to be in conformance with standards for the Standard Specifications for Road, Bridge, and Municipal Construction prepared by the Washington State Chapter of the American Public Works Association (APWA) and the Washington State Department of Transportation (WSDOT) and shall comply with the current edition, as modified by the City of Renton Supplemental Specifications. 1. An asphalt paver shall be used in accordance with Section 5-04.3(3) of Standard Specifications. A "Layton Box" or equal may be used in place of the power -propelled paver. Rollers shall be used in accordance with Section 5- 04.3(4) of the Standard Specifications, "Plate Compactors' and "Jumping Jacks" shall not be used In lieu of rollers. 2. Trench backfill and resurfacing shall be as shown in the City of Renton Standard Details, unless modified by the City permit. Surfacing depths shown in the standard details are minimums and may be increased by the Engineer to meet traffic loads or site conditions. 3. Re quire merrt for Patching, Overlay, and Overlay Widths: All trench and pavement cuts shall be made by sawcut or by grinding. Sawcuts or grinding shall be a minimum of one foot (1') outside the trench width- The top two inches (2") of asphalt shall be ground down to a minimum distance of one foot (1') beyond the actual outside edges of the trench and shall be replaced with two inches (2") of Class B asphalt, per City of Renton Standard Plans. At the discretion of the engineer, a full street width overlay may be required. Lane -width or a full street -width overlay will be determined based upon the location and length of the proposed trench within the roadway cross-section. Changes in field conditions may warrant implementation of additional overlay requirements. a. Trenches (Road Crossings): (1) The minimum width of a transverse patch (road Grossing) shall be six and one-half feet (6.5'). See City of Renton Standard Plans. (2) Any affected lane will be ground down two inches (2") and paved for the entire width of the lane. (3) The patch shall be a minimum of one foot (1') beyond the excavation and patch length shall be a minimum of an entire traveled lane. (4) If the outside of the trenching is within three feet (T) of any adjacent lane line, the entire adjacent traveled lane affected will be re paved. (5) An area including the trench and one foot (1') on each side of the trench but not less than six and one- half feet (6.5') total for the entire width of the affected traveled lanes will be ground down to a depth of two inches (2"). A two-inch (2") overlay of Class B asphalt will be applied per City standards. b. Trenches Running Parallel with the Street: (1) The minimum width of a longitudinal patch shall be four and one-half feet (4.5'). See City of Renton Standard Plans. (2) If the trenching is within a single traveled lane, an entire lane -width overlay will be required. (3) If the outside of the trenching is within three feet (3') of any adjacent lane line, the entire adjacent traveled land affected will be overlaid. (4) If the trenching is greater than or equal to 30% of lane per block (660 foot maximum block length), or if the total patches exceed 12 per block, then the lanes affected will be overlaid. Minimum overlay shall include all patches within the block section. (5) The entire traveled lane width for the length of the trench and an additional ten feet (10') at each end of the trench will be ground down to a depth of two inches (2"). A two-inch (2") overlay of Class B will be applied per City sta nda rds. c. Potholing: Potholing shall meet the same requirements as trenching and pavement restoration. Potholing shall be a minimum of one foot (1') beyond the excavation. All affected lanes will be ground down to a depth of two inches (2") and paved not less than six and one half feet (6.5') wide for the entire width of the lane. Potholes greater than five feet (5') in length, width or diameter shall be restored to trench restoration standards. In all cases potholes shall be repaired per Renton Standard Plans. Restoration requirements utilizing vactor equipment will be determined by the Engineer. 4. Pavement Removal in Lieu of Grinding: The contractor in all cases can remove the pavement in the replacement area instead of grinding out the specified two inches (2") of asphalt. Full pavement replacement to meet or exceed the existing pavement depth will be required for the area of pavement removal. Patching of pervious concrete shall follow American Concrete Institute (ACI) 522.1-13. Porous asphalt shall be specified on a project -by -project basis by the engineer. Permeable materials should be replaced in -kind where feasible. Patching porous asphalt with conventional asphalt is acceptable if it is no more than ten percent (100A) of the total facility area or does not impact the overall facility function. Appropriate precautions shall be taken during pavement repair and replacement efforts to prevent clogging of adjacent surfaces. S. Trench Backfill and Restoration Construction Requirements: a, Trench restoration shall be either by a patch or overlay method, as required and indicated on City of Renton Standard Plans. b. All trench and pavement cuts, which will not be overlaid, shall be made by sawcut or grinding. Sawcuts shall be a minimum of two feet (2') outside the excavated trench width. c. All trenching within the top four feet (4') shall be backfilled with crushed surfacing materials conforming to Section 4-04 of the Standard Specifications. Any trenching over four feet (4') in depth may use materials approved by the Engineer or Materials Lab for backfilling below the four -foot (4') depth. d. If the existing material (or other material) is determined by the Engineer to be suitable for backfill, the contractor may use the native material except that the top six inches (6") shall be crushed surfacing top course material. e. The trench shall be compacted to a minimum ninety-five percent (95%) density, as described in Section 2- 03 of the Standard Specifications. In the top six feet (6') of any trench, backfill compaction shall be performed in eight (8) to twelve -inch (12") lifts. Any trench deeper than six feet (6') may be earn pacted in twenty-four inch (24") lifts, up to the top six-foot (6') zone. All trench backfill shall be firm and unyielding but in no case shall be compacted to more than ninety-two percent (921y.) of maximum density in permeable pavement areas. f. All compaction shall be performed by mechanical methods. The compaction tests may be performed in four -foot (4') vertical increments maximum. The test results shall be given to the Engineer for review and approval prior to paving. The number and location of tests required shall be determined by the Engineer. d. Temporary restoration of trenches for overnight use shall be accomplished by using MC mix (cold mix), Asphalt Treated Base (ATB), or steel plates, as approved by the Engineer. ATB used for temporary restoration may be dumped directly into the trench, bladed out and rolled. After rolling, the trench must be filled flush with asphalt to provide a smooth riding surface. If the temporary trench restoration does 12-3-20 1 I NO. REVISION not hold up, the contractor shall repair the patch within eight hours of being notified of the problem by the City. This requirement applies 24 hours per day, seven days per week. In the event that the City determines to repair the temporary patch, the contractor shall reimburse the City in an amount that is double the City's costs in repairing the patch, with the second half of the reimbursement to represent City overhead and hidden costs. e. Asphalt Concrete Class E or Class B shall be placed to the compacted depth as required and indicated on City of Renton Standard Plans or as directed by the Engineer. The grade of asphalt shall be AR-4000W. The materials shall be made in conformance with Section 9-02,1(4) of the Standard Specifications. f. Tack coat shall be applied to the existing pavement at edge of saw cuts and shall be emulsified asphalt grade CSS-1, as specified in Section 9-02.1(6) of the Standard Specifications. Tack shall be applied as specified in Section 5-04 of the Standard Specifications. g. Asphalt Concrete Class E or Class B shall be placed in accordance with Section 5-04 of the Standard Specifications; except those longitudinal joints between successive layers of asphalt concrete shall be displaced laterally a minimum of twelve inches (12"), unless otherwise approved by the Engineer. Fine and coarse aggregate shall be in accordance with Section 9-03.8 of the Standard Specifications, All street surfaces, walks or driveways within the street trenching areas shall be feathered and shimmed to an extent that provides a smooth -riding connection and expeditious drainage flow for the newly paved surface. Feathering and shimming shall not decrease the minimum vertical curb depth below four inches (4") for storm water flow. The Engineer may require additional grinding to increase the curb depth available for storm water flow in areas that are inadequate, Shimming and feathering as required by the Engineer shall be accomplished by raking out the oversized aggregates from the Class B mix as appropriate. Surface smoothness shall be per Section 5-04.3(13) of the Standard Specifications. The paving shall be corrected by removal and repaving of the trench only. Asphalt patch depths will vary based upon the streets being trenched. The actual depths of asphalt and the work to be performed shall be as required and indicated on City of Renton Standard Plans - Compaction of all lifts of asphalt shall be a minimum ninety-two percent (92%) of density as determined by WSDOT Test Method 705. The number of tests required shall be determined by the Engineer. Testingshall be performed by an independent testing lab with the results being supplied to the Engineer. Testing is not intended to relieve the contractor from any liability for the trench restoration. It is intended to show the inspector, and the City, that the restoration meets these specifications. h. All joints, except those associated with permeable pavement, shall be sealed using paving asphalt AR- 4000W. i. When trenching within the unpaved roadway shoulder(s), the shoulder shall be restored to its original condition, or better. j. The final patch shall be completed as soon as possible and shall not exceed fifteen (15) working days after first opening the trench. This time frame may be adjusted if delays are due to inclement paving weather a other adverse conditions that may exist. However, delaying of final patch a overlay work is subject to the Engineer's approval. The Engineer may deem it necessary to complete the work within the fifteen (15) working day time frame and not allow any time extension. Should this occur, the contractor shall perform the necessary work, as directed by the Engineer. k. A City of Renton Temporary Traffic Control Plan (from Renton Transportation Engineering) shall be submitted and approved by the Engineer a minimum of three (3) working days prior to Commencement of work. 6. Removal of Utility Locate Markings from Sidewalks Required: The permittee will be required to remove utility locate marks on sidewalks only within the Center Downtown Zone. The permittee shall remove the utility locate marks within 14 days of job completion. SURVEYED: DESIGNED: R. DECCIO DRAWN: LR CHECKED: R. DECCIO BY I DATE I APPR I APPROVED: R. DECCIO SCALE: VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 1 "=20' DATUM ONE INCH AT FULL SCALE Planning/ IF NOT ONE INCH SCALE ACCORDINGLY CITY OF RENTON uilding/Public Works Dept. RECORD DRAWINGS 12-3-20 R-405219 IN COMPLIANCE WITH CITY OF RENTON STANDARDS AVON DEVELOPMENT 2 LOT SHORT PLAT NOTES DATE: 3-22-19 O J CV Z CW G O J W W 0 PAGE: DRAWING NO: Z R-405209 ' SHEET: OF:9 GENERAL NOTES N Lid The General Contractor is to provide subgrades 4" below hard surfaces plus/minus .l foot. p g 0 All rough grading shall be positive, draining away from all structures. O � All stones larger than 1.5" diameter shall be removed from the growing medium. 0 LU Topsoil shall be placed at a minimum depth of 6" in all lawn and bed areas. Topsoil shall be tilled into the existing subgrade to eliminate soil interface problems. All bed areas to receive 2" of fine ground fir or hemlock bark, composition mulches are not an acceptable alternative. Trees and shrubs are to be planted at a depth 3/4" higher than the level that they were grown in the Nursery. QBark mulch is not to be placed above the root crown. J All plants shall at least conform to the minimum standard established by the American Association of nurserymen. �I Lawn areas are to be hydroseeded per manufacturer's specifications, or equivalent. Remove all stones - W T_ W O larger than 1" from lawn areas. 3 \\ = Equivalent plant material substitutions may be allowed with prior approval by the Landscape Architect. \ V J \ 3 Z If the site work is different than shown on the Landscape Plan, or poor soils and debris are discovered, O requiring changes to the Landscape Plan, contact the Landscape Architect for instruction. �\ i The Landscape Contractor is responsible for maintaining the landscape during installation, until final \ Q acceptance by the owner's representative. \I STA: 6+58.55 / The Landscape Contractor shall warranty all materials and workmanship for a period of one year, from the time of final acceptance. / / During the warranty period, the Landscape Contractor will not be responsible for plant death caused by / unusual climatic conditions, vandalism, theft, fire, or poor maintenance practices. The Landscape �CEL / Architect shall have sole authority to determine the cause of death. 2565 / i Plant counts provided are estimates only. contractor is responsible for calculating all final area and Counts. EXl,'TI G RESIDENCE TO BE'RWED 2� IRRIGATION ASSESSMENT J All proposed plants have naturalized to the Pacific Northwest. Once, established irrigation will not be required. For the first growing season, temporary irrigation by means of hand watering truck shall be provided by the developer. Landscape areas shall be watered 3 times a week during the months of June -September. If there is an unusually dry summer, watering days may need to be increased by 1 or 2 days. MINIMUM TREE DENSITY Two (2) significant trees or two (2) new trees for every five thousand (5,000) sf of lot area. Lot A : (5,980/5000) x 2= 2 Required Trees 2 Trees Provided Lot B : (5,980/5000) x 2= 2 Required Trees 2 Trees Provided LANDSCAPE PLANTING SCHEDULE TREES SW 1/4 OF SE 1/4 OF SEC. 5, TWP. 23 N., RNG. 5 E., W.M CITY OF RENTON, STATE OF WASHINGTON SD 11 \W W W W W W\ W W \W W W 7•\ W W W1 W— \ 3 \ \ 14 TH S TR EE T \\ R.O.W. LANDSC\,PING S S �S s S\S SD AI�1111N�� X 89`43 "W.5W"5197�" R•/W .. TAX,7+62.45 10' FIR TAGGI� °' w 4'• ° — a LLLLLL L •.. LANDSCA CB .Li LLLi a •4 .awl .. �`' a . \. °• • w • L L� t;LLL - __ - �. RIM 274.49 INV=271.59 (12" ° �oI1 AINAG TILITY' ASEME T. w L I I� a EX. HOUSE TAX PARCEL m LOT "B" 334390-2566 I z I LOT\ "A" \ w M Z-30' INGRESS 8c UTILITY \ EASEMENT RC NO \ I I\ 5380145 M \ I \ EXISTING SHRUBS \ \ \\ I \ \PTO BE REMOVED \ o m A TYP. \ \ M \ mJ I \ n m \ 1 \ Z L— + m \ \ \ I \ 20' BSBL 20' BSBTING SHED L n \ I \ \ 3E REMOVED I A I SH \ \ � 68 ` N89'43' "W 51.92' SYMBOL QTY BOTANICAL / COMMON NAME SIZE CONDITION 1 Chamaecyparis nootkatensis Pendula / WEEPING ALASKA CEDAR 6'-8' HT. B&B. (2" CAL.) 2 Pyrus calleryana 'Chanticleer' / FLOWERING CHANTICLEER PEAR 2" CAL. B&B. 3 Amelanchier grandiflora Autumn Brilliance' / SERVICEBERRY 2" CAL. B&B. SHRUBS SYMBOL QTY BOTANICAL / COMMON NAME SIZE CONDITION 0 5 Nandina domestics 'Gulf Stream' / GULF STREAM HEAVENLY BAMBOO 2 GAL. CON. GRWN., 3 O.C. 8 Prunus laurocerasus `Otto Luyken' / 'OTTO LUYKEN' LAUREL 2 GAL. CON. GRWN., 3' O.C. 9 Spires x bumolda 'Goldflome' / GOLDFLAME SPIREA 2 GAL. CON. GRWN., 3' O.C. O 5 Ilex crenoto 'Convexa' / DWARF JAPANESE HOLLY 2 GAL. CON. GRWN., 5' O.C. GROUND COVER SYMBOL QTY BOTANICAL / COMMON NAME SIZE CONDITION JJJJJJJJJJJJ * Arctostaphylos uva—ursi / KINNIKINICK 4" POTS CON. GRWN 12" O.C. JJJJJJJJJJJJ JJJJJJJJJJJJ , * Hydroseed lawn * CONTRACTOR TO DETERMINE PLANT COUNT NEED TO ACHEIVE 90% COVERAGE IN 3 YEARS. EXISTING HEDGE TO BE REMOVED N89'43'49"W 51.92' \ \ N 0 20' 40' INSTALL GROUNDCOVERS AS SPECIFIED 2D D I � I INSTALL FERTILIZERS PER MANUFACTURERS RECOMMENDATIONS TOP DRESSING FERTILIZER AS SPECIFIED TYPICAL FINISHED GRA W/ 2"LAYER SPECIFIED MULCH. VERIFY SAUCE I,GC� �'.��►v��::.r�s/c�� ::r�r7L�; I, ��C� lio.,; ��810111i%�=��i.►`�:r�s"��i111��11 �;��►v��::.r�s/c�� ::r�ri1.�; r i7il� SCALE: NTS 1 SITE PLAN CHANGES N0. REVISION PLAN VIEW OF SPACING SURVEYED: DESIGNED: KL DRAWN: KL 77 4 11 19 CHECKEDKL BY DATE APPR APPROVED: KL BACKFILL WITH EXIST SOIL. IF UNSUITA SOIL IS FOUND, CONT LANDSCAPE ARCHITI FINISH GR, NOTE: DRIVE STAKES UNTIL FIRM IN GROUND TO SUPPORT TREE. TREE STAKING SCALE: NTS INSTALL 1"ABOVE CONTAINER DEPTH PLACE 2" LAYER OF SPECIFIED MULCH OVER PLANTING BED. BACKFILL PLANTING PIT WITH SPECIFIED MIX OF NATIVE AND IMPORTED SOIL. MOUND CENTER OF PLANTING PIT COMPACT TO SUBGRADE DENSITY. SHRUB PLANTING SCALE: NTS 1 /2 SPACING DISTANCE SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM t m NE 16111 St N s t n m HE 14th St 'hole a Audio on Inn & SeattleFRen N CHAINLOCK TREE TIE 12" BVC ROUND STAKES SET ITSIDE ROOTBALL EMOVE AFTER ONE YEAR.) .RK MULCH 2" DEPTH !EP CLEAR OF TRUNK BASE I. BERM/WATER BASIN 1T AND REMOVE TWINE ID BURLAP FROM TOP ID SIDES OF ROOTBALL. EMOVE ALL WIRE SKETS.) MPACTED NATIVE SOIL REMOVE UNTREATED BURLAP FROM TIP 1 /3 OF ROOTBALL. REMOVE TREATED BURLAP OR WIRE BASKETS COMPLETELY. CONTAINER PLANTS -SCORE ROOTBALLS IN 3 PLACES TO 1 /2" DEPTH. TOP DRESSING FERTILIZER, SEE SPECIFICATION. PROVIDE WATER SAUCER. FINISH GRADE OF SOIL. PLANT TABS. QUANTITY ACCORDING TO MANUFACTURER'S SPECIFICATIONS. • CITY OF RENTON PIG nning/Building/Public Works Dept. 19 m HE 16th St a m ae g � D D 2 Y ry 2 m m Northeast 14th Street & Lincoln... NE 141h St A z o m VICINITY MAP NTS ORIGIN 1031 185TH AVE NE SNOHOMISH, WA 98290 TEL: 425.346.1905 �� ba STATE OF WASHINGTON LICENSED LANDSCAPE ARCHITECT KRYSTAL LOWE LICENCE NO. 1206 APPROVALS CITY OF RENTON DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT EXAMINED AND APPROVED THIS DAY OF 9 20--, X X X X X X I X X u X X X X X X X Q J X X X X X X X X CITY OF RENTON ADMINISTRATOR ~ Q R-405220 IN COMPLIANCE WITH CITY OF RENTON STANDARDS ~ O 2 Z O Q AVON SHORT PLAT 12-4-17 FIELDBOOK: PAGE: LANDSCAPE —PLAN DRAWING N0: 17-177 SHEET: OF: L1 OF1