Loading...
HomeMy WebLinkAboutR-409721p V III r LU VVlu�l I�I�ll�llll Q J n O Cn Q n Q 0 X Cn w Q 0 0 7 CD N CD cv N i E 0 0 co 03 N 0C 00 CD CD CD w j z J TREE LEGEND 0 EXISTING DECIDUOUS TREE TO BE RETAINED, PER TREE PROTECTION DETAIL, SHEET L-2 EXISTING EVERGREEN TREE TO BE RETAINED PER TREE PROTECTION DETAIL, SHEET L-2 t� EXISTING DECIDUOUS TREE TO BE REMOVED EXISTING EVERGREEN TREE TO BE REMOVED D_ 18"CON. 1 CON. W I >tEAD (EC �M V2 \ wAIEH— _ MV�LV_M — G G" T ] EXISTING RO ------------- �, 1 L4 Q � -SS - SS - SS TREE RETENTION PLAN — INVENTORY SCALE 1" = 20'-0" DATUM HORIZONTAL DATUM NAD '83/' 1 1 BENCHMARKFOUND 1.5" BRASS DISK WITH PUNCH MARK IN CASE AT UNION AVENUE NORTHEAST AND NE 19TH VERTICAL DATUM: STREET, KNOWN AS CITY OF NAVD '88 RENTON CONTROL POINT #716 TREE RETENTION and LANDSCAPE SET 2" BRASS DISK WITH PUNCH MARK IN CASE AT THE INTERSECTION OF NORTHEAST 19TH STREET AND DUVALL, KNOWN AS CITY OF RENTON CONTROL POINT #1996 NO. OF DALPAY SHORT PLAT A PORTION OF THE N.E. 1/4 OF THE S.E. 1/4 OF SECTION 4, TOWNSHIP 23 N., RANGE 5 E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON POST B' - 1O' ON-GENTER POST i I Protection Measures During Construction: Protection measures in this subsection shall apply for all trees that are to be retained. All of the following tree protection measures shall apply: a. Construction Storage Prohibited: The applicant may not fill, excavate, stack or store any equipment, dispose of any materials, supplies or fluids, operate any equipment, install impervious surfaces, or compact the earth in any way within the area defined by the drip line of any tree to be retained. b. Fenced Protection Area Required: Prior to development activities, the applicant shall erect and maintain six-foot (6) high chain link temporary construction fencing around the drip lines of all retained trees or at a distance surrounding the tree equal to one and one -quarter feet (1.25') for every one inch (1 ") of trunk caliper, whichever is greater, or along the perimeter of a tree protection tract. Placards shall be placed on fencing every fifty feet (50') indicating the words, "NO TRESPASSING — Protected Trees," or on each side of the fencing if less than fifty feet (50'). Site access to individually protected trees or groups of trees shall be fenced and signed. Individual trees shall be fenced on four (4) sides. In addition, the applicant shall provide supervision whenever equipment or trucks are moving near trees. c. Protection from Grade Changes: If the grade level adjoining to a tree to be retained is to be raised, the applicant shall construct a dry rock wall or rock well around the tree. The diameter of this wall or well must be equal to the VI2E0 STEEL P05T tree's drip line. d. Impervious Surfaces Prohibited within the Drip Line: The applicant may not install impervious surface material within the area defined by the drip line of any tree to be retained. e. Restrictions on Grading within the Drip Lines of Retained Trees: The grade level around any tree to be retained may not be lowered within the greater of the following areas: (i) the area defined by the drip line of the tree, or (ii) an area around the tree equal to one and one-half feet (1-1/2') in diameter for each one inch (1") of tree caliper. A larger tree protection zone based on tree size, species, soil, or other conditions may be required. (Ord. 5676, 12-3-2012) EXI5TIN6 GRADE f. Mulch Layer Required: All areas within the required fencing shall be covered completely and evenly with a minimum of three inches (3") of bark mulch prior to installation of the protective fencing. Exceptions may be approved if the mulch will adversely affect protected ground cover plants. (Ord. 5676, 12-3-2012) g. Monitoring Required during Construction: The applicant shall retain a certified arborist or licensed landscape architect to ensure trees are protected from development activities and/or to prune branches and roots, fertilize, and COMPACTED OR water as appropriate for any trees and ground cover that are to be retained. EXISTING SUBGRADE h. Alternative Protection: Alternative safeguards may be used if determined to provide equal or greater tree protection. (Ord. 5676, 12-3-2012) TREE PROTECTION DETAIL NOT TO SCALE \ ,,--- SS19O RIM1416.30' APN 042305-94 9 9 TUAIN INGUYE Ill ONLY NUMBERED TREES WITHIN N.G.P.E. EASEMENT WERE INSPECTED BY LANDSCAPE ARCHITECT. TREES WITHOUT NUMBERS WERE NOT INSPECTED. ALL TREES WITHIN N.G.P.E. TO BE RETAINED TREE #013 TREE #014 TREE #015 �JREE #018 REE #017 /TkE� #016 0 0 0 u TREE�#022 TREE #023 THEE #024 TREE #025 TREE #028 TREE #026 TREE#027 TREE#029 TREE #030 TREE #031 TREE #034 R-409521 OF WAs/y/ VgR���co U a n b EXP % U Zs 8.25.? �Q NO. 774 EXP �G 4'qNDSCAP�P Ul IE ILI mar) 01 4�1 WI 4 J QI�6 ._ 0 LU Ca� Imo, 1: ) Ny�gJ �;( 1 4C� Jp z (d< � V rc' C-4 M �03 1'�' U r i v IN COMPLIANCE WITH CITY OF RENTON STANDARDS PLANNING DIVISION APPROVED 11/09/2020 jding SURVEYED: SCALE: TSL VERTICAL: AD 1 83/1 C TY OF TREE RETENTION PLAN HORIZONTAL: NAD 1983/1991 988 DESIGNED: RENTON DALPAY SHORT PLAT .� DRAWN: BLS , ONE INCH DATUM DALPAY PROPERTIES, LLC. CHECKED: AT FULL SCALE Plan ning/Building/Public Works Dept. 4033 N.E. SUNSET BOULEVARD BLS IF NOT ONE INCH REVISION BY DATE APPR APPROVED::LS SCALE ACCORDINGLY RENTON, WA 98059 Q 0_00 00 —00 rr ObDATE: U) y { } !�/ 2/1 1 /20 FIELDBOOK: PAGE: >_ A , DRAWING NO: _J SHEET: OF: L-1 0 Ind