Loading...
HomeMy WebLinkAboutR-417225CLI 7t O 7t 7 J TL 10 ''"" COILED WIRE RPROOF CONNECTORS (2) 7,ONE KIT 1 ICZ-101-XX WITH R (TIP 45 DEGREES) LATOR 25 OR 40 PSI H GRADE t0 VALVE BOX 30 T.O.E. NIPPLE (2) LINE PIPE & FITTINGS BRICK SUPPORTS (4) U NUS WASHED GRAVEL „ .LIP UNIONS (2) DRIP CONTROL ZONE VALVE ITE IRRIGATION DETAIL FINISH GRADE RECLANED CA MODEL PROS -I SPRAY HEAD V OPTION INSTAL HUNTER SWINI LATERAL PIPE LATERAL TEE C._ . �. �.. POP-UP SPRAY HEAD PAVEMENT, ASPHALT OR CONCRETE TRENCH SECTIONS FINISH GRADE, BURIAL MEASUREMENT POINT. COMPACTED CRUSHED AGGREGATE PAVEMENT SUBBASE COMPACTED SUBGRADE r, TRENCH BACKFILL 50 SCH. 40 PVC SLEEVE, 2(x) THE SIZE OF PIPE WHICH IT CRADLES 2" DIA. SCH. 40 PVC SLEEVE FOR ELEC. WIRES. NOTES: 1. TRENCH BACKFILL SHALL BE FREE OF ROCK OR DEBRIS GREATER THAN 1" IN SIZE. 2. DO NOT PLACE ROCK/DEBRIS DIRECTLY AGAINST SLEEVE. 3. EXTEND SLEEVE 12" BEYOND PAVEMENT EDGE OR AS REQ'D. PER GRADE CONDITIONS. ASPEN LANDSCAPE ARCHITECTURE SITE PLANNING 2"-3" BARK MULCH, OR OTHER TYPE OF MULCH AS SPECIFIED ON LANDSCAPE PLAN. ASPEN DESIGN GROUP P.O. BOX 2394 ISSAQUAH, WA 98027 (425) 292-9845 (PHONE) CONTACT: PAUL J. DIX FINISH GRADE 18-24" COILED WIRE MODEL HQ-44LRC-R QUICK COUPLER VALVE WATERPROOF CONNECTORS (2) Y�Vv} AV, REMOTE CONTROL VALVE MODEL 10"ROUND VALVE BOX ICV-10IG ACCU-SYNC-ADJ 3/4" MINUS GRAVEL FINISH GRADE ° #4 REBAR W/SS HOSE CLAMPS STANDARD VALVE BOX PREFABRICATED SWING JOINT MAIN LINE PIPE & FITTIN G S o o a a a a a a a o 0 0 �� LINE PIPE 0 0 0 0 0 0 0 0 0 SCH 80 T.O.E. NIPPLE o MAIN LINE TEE OR ELL 0 0 0 0 0 0 0 BRICK SUPPORTS (4) •V 3/4" MINUS WASHED GRAVEL PVC SLIP UNIONS SPRAY CONTROL ZONE VALVE [ET00hV IRRIGATION DETAIL IRRIGATION CONTROLLER FINISH GRADE, BURIAL MEASUREMENT POINT. PLANTING TOPSOIL LATERAL LINE TRENCH BACKFILL UNDISTURBED NATIVE SOIL MAIN LINE CONTROL WI RES NOTES: L TRENCH BACKFILL SHALL BE FREE OF ROCK OR DEBRIS GREATER THAN 1" IN SIZE. 2. DO NOT PLACE ROCK/DEBRIS DIRECTLY AGAINST PIPE. 3. IN TRENCH W/ BOTH MAIN & LATERAL LINES, OFFSET PIPES 6" N HORIZONTAL DIRECTION STATE OF WASHINGTON REGISTERED LANDSCAPE ARCHITECT PAUL J. DIX CERTIFICATE NO. 620 DI D2 MODEL ACC-XX00-PED 3/4" POWER CONDUIT: SIZE, TYPE, DEPTH PER LOCAL CODE GROUND WIRE CONDUIT, MIN.11/2". GROUND PER ASIC GUIDELINES PEDESTAL BASE: CONCRETE OR PREFABRICATED FINISH GRADE CONDUIT FOR CONTROL WIRES F0UUH0h1° IRRIGATION DETAIL OVERLAP ECO MAT OVER CONNECTION AND TO EDGE OF PLANTED AND IRRIGATED AREA DI - LUU MAI DI I'M F R FLAN D2 -12" OR PER PLANS ECO-MAT 1 REVISED-PER-CITY-REVIEW-COVVENTS BRICK SUPPORT (3) UICK COUPLER VALVE [ETOahM IRRIGATION DETAIL SOLAR SYNC PLD-ELB,17mm BARB X BARB 90 DEGREE ELL TURF GRASS, GROUND COVERS OR SHRUBS, SEE PLANTING PLANS L FINISHED GRADE AMENDED SOIL ECO MAT SUBSURFACE IRRIGATION MAT WITH 17mm DRIP LINE TUBING, WRAPPED IN POLYPROPYLENE FLEECE PLD-075,17mm BARB X 3/4" MIPT ADAPTER, W/ 8" OF BLANK PLD TUBING SITE SOIL PVC LATERAL LINE PVC S ST TEE 1711TING, LATERAL SIZE X 3/4' CONNECTION MODEL: SOLAR SYNC SENSOR SUITABLE POST, POLE, GUTTER MOUNT. MOUNT IN LOCATION THAT MAXIMIZES DIRECT SUNLIGHT, OPEN TO RAINFALL AND OUT OF SPRINKLER SPRAY PATTERN CONDUIT FROM SOLAR SYNC SENSOR TO CONTROLLER OR TO A POINT 12" BELOW GRADE HUNTER ACC CONTROLLER DRAIN VALVE CONDUIT FORVALVE CONTROLWIRE AND SOLAR SYNC COMMUNICATION WIRE CONTROLLER POWER SOURCE COMMUNICATION WIRE,18-2(WIRE TYPE TO MEET INSTALLATION CODE REQUIREMENTS), FROM MODULE TO SENSOR. MAXIMUM TOTAL WIRE DISTANCE, 200 FEET 13n" p7cm) lin, pcm) RECOMMENDED ECO MAT INSTALLATION DEPTH (D): TURF AREAS: 4" - 8" (10cm - 20cm) GROUND COVER AREAS: 8" (20cm) SHRUB AREAS: 12" (30CM) SECTION PJD I6-02-2021I PJD SURVEYEPN/CB SCALE: DESIGNED: PJD DRAWN: PJD ONE INCH CHECKED: PJD AT FULL SCALE IF NOT ONE INCH BY DATE APPR SCALE ACCORDINGLY APPROVED: [ETIOjIV IRRIGATION DETAIL SOD STAKE INSTALLED 8 FT ON CENTER OVER TUBING TURF GRASS, GROUND COVERS OR SHRUBS, SEE PLANTING PLANS FINISHED GRADE AMENDED SOIL ECO MAT SUBSURFACE IRRIGATION SITE SOIL OVERLAP MAT 4" (10cm) 17mm DRIP LINE TUBING, POLYPROPYLENE FLEECE WRAPPED VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M OT USED FINISH GRADEJOP OF MULCH VALVE BOX WITH COVER: PVC SCH 40 TEE PVC LATERAL PIPE FILTERED DRAIN VALVE: BRICK (1 OF 2) 6-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL ICZ DRIP CONTROL ZONE KIT, SIZE PER PLAN, (1" KIT SHOWN) PVC /TUBING CONNECTION PVC SUPPLY HEADER, SIZE AS REQUIRED, SEE PLANS ECO MAT SUBSURFACE IRRIGATION MAT DRIP LINE TUBING, WRAPPED IN POLYPROPYLENE FLEECE PLD-TEE, 17mm BARB X BARB X BARB TEE FITTING PLD-BV,17mm BARBED SHUT-OFF / FLUSH VALVE 17mm PLD BLANK TUBING AS DISCHARGE HEADER NOTE: SEE CATALOG FOR ALLOWABLE LENGTH OF TUBING RUN (D). PVC SUPPLY HEADER AND POLY DISCHARGE HEADER. PLAN 9 C T Y OF RENTON Planning/Building/Public Works Dept. Fflundar IRRIGATION DETAIL Cd m O O C� U O �0 O O O O O 0 O O O O P-417220 IN CODUEIANCE WITH CITY OF RENTON STANDARDS Q CURRENT PLANNING Alex Morganroth 12/21/2021 ' HEI LIN SHORT PLAT 4ELIHINARY SUBDIVISION SUBHITTAL IRRIUPITION DETAILS 0 Z DATE: 02/18/20 Z FIELDBOOK: N/A ~� PAGE: N/A DRAWING NO: 1557421 W SHEET: 5 OF: 8