HomeMy WebLinkAboutEx09_Geotechnical_Report Gary A. Flowers, PLLC
Geological & Geotechnical Consulting
5205 23rd Avenue W
Everett, WA 98203
Gary A. Flowers, PLLC.
5205 23rd Avenue W Everett, Washington 98203 206-819-4304
1
October 27, 2021
Project No. 21021
Xiao Zhang
440 Maple Ave SW
Apt. B201
Renton, WA 98057-2801
Subject: Geotechnical Services Report
Shum Short Plat
1157 Queen Ave NE
Renton, Washington
This report summarizes the results of our geological and infiltration evaluation of the property
located at the above noted address in Renton, WA. Infiltration testing was provided in general
accordance with the 2017 Renton Storm Water Design Manual.
EXISTING CONDITIONS
The property is currently undeveloped and is flat lying with a barely discernible downward slope
from west to east. Overall relief is on the order of 2 feet. The site is primarily vegetated with tall
field grass, an area of blackberry bushes in the southeast corner, a cedar hedge along the south
property line and a few deciduous trees.
At the time of our study there was no evidence of standing or flowing water on the parcel.
Subsurface Exploration
In order to confirm subsurface conditions on th e property a series of 3 exploration pits were
excavated on October 13, 2021. Logs of the exploration pits are attached with this report.
Generally, medium dense to very dense silty sand with gravel was observed on the site. This
sediment is interpreted to be Vashon age lodgement till. Lodgement till is a nonhomogeneous
mixture of sand and gravel in a silt/clay matrix. This material was deposited in front of the
advancing ice sheet on the order of 13,500 years ago and subsequently overrun by the ice which
is thought to have been in excess of 3,000 feet thick in this area. The result is a densely
consolidated soil with high strength and low permeability characteristics.
Ground water seepage was not observed in any of the exploration pits and no caving conditions
were observed within the sidewalls of the exploration pits.
DocuSign Envelope ID: B58AD446-584F-46BF-8420-90761B7E491E
Shum 2 Lot Short Plat Geotechnical Services Report
1157 Queen Avenue NE, Renton, Washington
Gary A. Flowers, PLLC.
5205 23rd Avenue W Everett, Washington 98203 206-819-4304
2
Mappings
According to the Geologic Map of King County, Washington, by Booth, Troost and Wisher, March
2007, the site is mapped as Vashon age glacial till (Qvt). Our explorations are in agreement with
the published geology map of the area.
Infiltration of Storm Water
We understand that infiltration of storm water on-site was to be considered for the project. Our
subsurface explorations were located in order to encompass both potential building sites should
the short plat be granted.
In order to verify whether or not there was any infiltration potential within the observed sediments
an infiltration test was performed on these soils.
Testing was completed in general accordance with City of Renton 2017 Storm Water Design
Manual and Reference 6-A for a small scale pilot infiltration test (PIT). Based on our current
understanding storm water would be infiltrated into one or more infiltration trenches
approximately 3 feet below existing grade. As such, the infiltration testing was completed at a
depth which included the planned receptor soils.
The pit was excavated to a depth of 3.1 feet and the bottom measured 4.7 feet long and 4.1 feet
wide for a total area of 19.27 square feet. Presoaking and testing was completed using a garden
hose running into an 4-foot long, 4-inch diameter, perforated, pvc pipe with a cap for a splash plate
on the bottom end. The pvc pipe was marked in half-inch increments as required. Water was then
added to the pit for the pre-soak period and maintained at a depth of 12 to 14 inches for 6 hours.
It should be noted that little to no water flow was required in order to maintain the water depth. In
fact, at the lowest water flow setting attainable with the available equipment the water level
continued to rise throughout the soak period. Following the pre-soak, the water flow was shut off
to allow the water level to adjust to the required 6-inch head. After 2 hours the water level had
only reduced by less than 1 inch.
Due to the conditions detailed above, the constant head test was not performed. The falling head
test was then performed for an hour. During the falling head test the water level reduced by
approximately .5 inches in one hour even with a 12-inch head instead of a 6-inch head.
Based on the results of our explorations that encountered glacial till sediments at shallow depth,
the measured infiltration rate and the required correction factors for testing, geometry and
plugging, it is our opinion that the design infiltration rate is nil and no consideration should be
given to infiltration of storm water on this property. This is typical for sites that are underlain by
glacial till sediments.
DocuSign Envelope ID: B58AD446-584F-46BF-8420-90761B7E491E
Shum 2 Lot Short Plat Geotechnical Services Report
1157 Queen Avenue NE, Renton, Washington
Gary A. Flowers, PLLC.
5205 23rd Avenue W Everett, Washington 98203 206-819-4304
3
SUMMARY
Our findings and recommendations provided in this report were prepared in accordance with
generally accepted principles of engineering geology and geotechnical engineering as practiced in
the Puget Sound area at the time this report was submitted. We make no other warranty, either
express or implied.
Thank you for the opportunity to be of service. Should you have any questions please do not
hesitate to contact our office.
Respectfully submitted,
Gary A. Flowers, P.G., P.E.G.
Principal Engineering Geologist
Attachments: Exploration Pit Logs
Site & Exploration Plan
DocuSign Envelope ID: B58AD446-584F-46BF-8420-90761B7E491E
Shum 2 Lot Short Plat Geotechnical Services Report
1157 Queen Avenue NE, Renton, Washington
Gary A. Flowers, PLLC.
5205 23rd Avenue W Everett, Washington 98203 206-819-4304
4
EXPLORATION PIT LOGS
Shum 2 Lot Short Plat
1157 Queen Avenue NE
Renton, WA
EP-1 Approximate elevation 432 feet
0.0’ – 1.0’ Loose, moist, grayish-black, silty SAND (topsoil) and grass sod
1.0’ – 2.5’ Medium dense, light brown, silty sand with gravel (glacial till) [SM]
2.5’ – 4.0’ Very dense, light brown, silty sand with gravel (glacial till) [SM]
Bottom of pit at 4.0 feet on 10/13/2021. No ground water. No caving.
EP-2 Approximate elevation 432 feet
0.0’ – 1.0’ Loose, moist, grayish-black, silty SAND (topsoil) and grass sod
1.0’ – 2.5’ Medium dense, light brown, silty sand with gravel (glacial till) [SM]
2.5’ – 4.0’ Very dense, light brown, silty sand with gravel (glacial till) [SM]
Bottom of pit at 4.0 feet on 10/13/2021. No ground water. No caving.
EP-3 Approximate elevation 431 feet
0.0’ – 1.0’ Loose, moist, grayish-black, silty SAND (topsoil) and grass sod
1.0’ – 2.5’ Medium dense, light brown, silty sand with gravel (glacial till) [SM]
2.5’ – 4.0’ Very dense, light brown, silty sand with gravel (glacial till) [SM]
Bottom of pit at 4.0 feet on 10/13/2021. No ground water. No caving.
IP-1 Approximate elevation 430 feet
0.0’ – 1.0’ Loose, moist, grayish-black, silty SAND (topsoil) and grass sod
1.0’ – 2.5’ Medium dense, light brown, silty sand with gravel (glacial till) [SM]
2.5’ – 3.1’ Very dense, light brown, silty sand with gravel (glacial till) [SM]
Bottom of pit at 4.0 feet on 10/13/2021. No ground water. No caving.
DocuSign Envelope ID: B58AD446-584F-46BF-8420-90761B7E491E
30.02'30.02'NE 12TH STREET
N87°59'46"W 2,625.71'(M)(R1)210.16'210.16'N00°15'00"W 240.18'S00°15'59"E 240.18'1,506.81'(C)(R1)
134.07'(C)(R1)
W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)
FOUND PUNCH ON
1 1/2" BRASS DISK IN
IN CASE
DOWN 0.7'
08-30-21
UNION AVE. NEFOUND 1/8" PIN
IN CONC
MON IN CASE
DOWN 1.5'
08-30-21MONROE AVE. NE805.92'(C)(R1)
FOUND TACK IN
CONC MON IN CASE
DOWN 2.1'
08-30-21
MONROE AVE. NE178.91'(R1)
178.92'(M)
TREE CANOPY/DRIP LINE
FENCE LINE (TYPE AS NOTED)x
BUILDING LINE
TELEPHONE RISERTJR
MONUMENT (FOUND AS NOTED)
SIGN
DECIDUOUS TREE
CONIFEROUS TREE
WATER VALVE
FIRE HYDRANT
HOSE BIB
STORM DRAIN MANHOLE
STORM CATCH BASIN
SEWER MANHOLE
POWER POLE/LIGHT POLE
GUY ANCHOR
GAS METER
S
D
GM
WV
POWER OVERHEAD LINEOP
SANITARY SEWER PIPESS
STORM DRAIN PIPESD
CONCRETE PAVING
ASPHALT PAVING
REBAR (FOUND AS NOTED)
POST OR BOLLARD
GAS VALVEGV
F FIR TREE
M MAPLE
TREE LEGEND
LEGEND
(C)
(M)
P/L
CLF
CALCULATED DIMENSION
MEASURED DIMENSION
PROPERTY LINE
CHAIN LINK FENCE
WATER LINE PER RECORD DATAW(D)xxxxxxxxxxxxxxxxxxxxxxxx x x x x x x x x xxxxxxxxxxxxxxxxxxxN00°15'00"W 20.02'N87°59'46"W 20.02'QUEEN AVEWV
WV
18"F
20"F
14"F
30"F
26"F
30"F
S 32"F
26"F
30"F
60"MA 12"DEC
16"DEC
30"F
10"M
WV
TJR
WMS
8"DEC(2)
FOUND 1/2"
REBAR AND CAP
AT GRADE
"MHT 9470"
E. 0.1'
09-02-21
FOUND 1/2" REBAR AND
CAP IN 5" X 5" CONC
"MHT 9470"
E. 0.1'
09-02-21
FOUND BARE 1/4"
REBAR
W. 0.5'
09-02-21
xxOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOP5' TALL CLF
x5' TALL CLF
VERTICAL CURB5' TALL CLFCONC SLAB
TREE CANOPY
LINE (TYP)
TREE CANOPY
LINE (TYP)
TREE CANOPY
LINE (TYP)5' TALL CLFGATE5' TALL CLFCEDAR HEDGE
430
43243
2
432OPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOPOP
~PIERCE AVE NEPARCEL A
KING COUNTY BOUNDARY
LINE ADJUSTMENT
REC.NO. 9802099012
SSMH
TOP 432.03
IE 427.63 (8" PVC (OUT-N)
BOTTOM STRUCTURE
ELEV. 427.66
NO CHANNEL
SSMH
TOP 434.25
8" PVC (W), 8" CONC (N),
8" CONC (S)
CENTER CHANNEL
ELEV. 425.43
CATCH BASIN
TOP 433.33
6" CONC IE 432.30 (IN-W)
8" CMP IE 431.28 (OUT-S)SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS~SD
SD
SD
SDSDSDSDTBM 1
TOP REBAR/CAP
EL = 434.36'430.5429.8432.7430.1430.6432.1432.5432.46432.17432.9
2433.15433.82434.04433.84433.41433.39433.51432.44430.
0431.3433.4434.7432.6431.6429.7430.3431.7430.3430.3432.6432.0N87°59'50"W 134.14'(C) 134.13'(R1)
N87°59'46"W 114.15'S00°15'59"E 131.11'S00°15'00"E 111.09'430
4324344344344304
3
0 432430430 5' TALL CLF0.5'
0.6'
FENCE CROSSES P/L
FENCE 0.1' S. OF P/LFENCE 0.2' S. OF P/L
1.8'
CONC DRIVECONC WALKTBM 2
TOP REBAR/CAP
EL = 430.64'
4.8'
30.00'
30.00'W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)W(D)
CATCH BASIN
TOP 433.61
6" CONC IE 432.30 (OUT-E)SSSS~30.00'
30.00'
3.3'
10.7'
9.8'REVISIONOFSHEET NO.DRAWING FILE:PROJECT NUMBER:NUMBER: SCALE: DATE:DESIGN:DRAWN:CHECKED: REVISIONS:APPD.SV-TP-OWDV01880001.dwgSave Date:
Plot Date:
9/21/2021 2:46 PM
9/24/2021 10:35 AM
By: Arj P:\O\OWDV01880001\0400CAD\SV\BASES\SV-TP-OWDV01880001.dwg
Aaron JenningsBy:
File:
POR. NW 1/4, NE 1/4, SEC. 9, TWP. 23 N., RGE. 5 E., W.M.
TOPOGRAPHIC SURVEY
FOR
SHUM PROPERTY
HOI-FUNG SHUM
17723 110TH PLACE SE, RENTON, WA 98055SEPTEMBER 24, 2021ARJ1"=10'OWDV0188-0000111®
20300 Woodinville Snohomish Rd. NE, Ste A
Woodinville Washington 98072
Phone: 425.415.2000
NORTH
1. INSTRUMENTATION FOR THIS SURVEY WAS A TRIMBLE
TOTAL STATION. PROCEDURES USED IN THIS SURVEY WERE
FIELD TRAVERSE, MEETING OR EXCEEDING STANDARDS SET
BY WAC 332-130-090.
2. PRIMARY CONTROL POINTS AND ACCESSIBLE MONUMENT
POSITIONS WERE FIELD MEASURED UTILIZING GLOBAL
POSITIONING SYSTEM (GPS) SURVEY TECHNIQUES USING
TRIMBLE EQUIPMENT. MONUMENT POSITIONS THAT WERE
NOT DIRECTLY OBSERVED USING GPS SURVEY TECHNIQUES
WERE TIED INTO THE CONTROL POINTS UTILIZING TRIMBLE
ELECTRONIC TOTAL STATIONS FOR THE MEASUREMENT OF
BOTH ANGLES AND DISTANCES. THIS SURVEY MEETS OR
EXCEEDS THE STANDARDS SET BY WAC 332-130-090.
3. THE INFORMATION DEPICTED ON THIS MAP REPRESENTS
THE RESULTS OF A SURVEY MADE ON SEPTEMBER 3, 2021
AND CAN ONLY BE CONSIDERED AS INDICATING THE
GENERAL CONDITION EXISTING AT THAT TIME.
4. NO EASEMENTS, RESTRICTIONS OR RESERVATION OF
RECORD WHICH WOULD BE DISCLOSED BY TITLE REPORT
ARE SHOWN.
5. CONTOUR INTERVAL: 2 FOOT
PARCEL A OF KING COUNTY BOUNDARY LINE
ADJUSTMENT, RECORDED UNDER RECORDING NO.
9802099012, RECORDS OF KING COUNTY, WASHINGTON.
NAVD 88
BASED ON GPS OBSERVATIONS.
SITE BENCH MARKS:
TBM 1: TOP OF REBAR AND CAP, SET IN ASPH DRIVE,
46'± SW OF SW CORNER OF SUBJECT PROPERTY ON SITE AS SHOWN
ELEVATION = 434.36'
TBM 2: TOP OF REBAR AND CAP, SET IN MIDDLE OF SUBJECT
PROPERTY AS SHOWN
ELEVATION = 430.64'
EROF
GI
E OY
DU
Call: TOLL FREE
1-800-424-5555CLLABCALL BEFORE YOU DIG
1. KING COUNTY BOUNDARY LINE ADJUSTMENT,
RECORDED UNDER RECORDING NO. 9802099012,
RECORDS OF KING COUNTY, WASHINGTON.
09-24-21
GARY A. FLOWERS, PLLC
PROJECT NO. 21021
SHUM PARCEL - 1157 QUEEN AVE NE
IP-1
EP-3
EP-2EP-1
DocuSign Envelope ID: B58AD446-584F-46BF-8420-90761B7E491E