HomeMy WebLinkAboutMFP21000326.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP21000326 IVR Number: 21000326 Permit Information Permit Name: Puget Sound Energy - Electric Address/Location:01/22/2021Application Date:3340401606Parcel Number: 1401 SHATTUCK AVE S Permit Type:01/25/2021Issue Date:Franchise Permit Work Class:01/25/2022Expiration Date:Major Utility Job Number: 101132018Franchise Type:Electric Description: Puget Sound Energy Electric **DUIP** CREW TO RE REOUTE UG CABLE IN CONFLICT WTIH THE NEW STORM AND WATER ALIGNMENT. PRE CONSTRUCTION MEETING REQUIRED. RESTORATION PER CITY OF RENTON STANDARDS. Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 6905 S 228TH St KENT, WA 98032 C: (253) 905-5031ApplicantX Carli Bunkelman PSE/POTELCO - Billing 6905 S 228th St Kent, WA 98032 B: (253) 437-6708Contractor Business License Number: 5109Construction Contractor: POTELI*227PL WSDOT -REAL ESTATE SERVICES PO BOX 330310 #MS118 SEATTLE , WA 98133 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF PUBLIC WORKS Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 1 of 2 | Published: 1ϭ/Ϯϱ/2019 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN (TCP) APPLICATION Published: 1ϭ/Ϯϱ/2019 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. TO THE APPLICANT: Submit the TCP application form and required submittal documents to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address. The following items, electronic copies preferred, are all required for submittal of the TCP Application: 1.܆ A copy of the Traffic Control Plan (TCP) Application form. 2.܆ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall: ܆ Include map(s) showing the location of the project and work area. ܆ Be legible lettering and clear, contrasting, symbols of viewing or printing. ܆ Must indicate street names, and north arrow and scale. ܆ All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. ܆ Types of plans required: ܆ Work hour plan – show all mobility impacts during construction hours. ܆ Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. ܆ Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. ܆ Pedestrian access/detour plan, if applicable. Project Name: ______________________________________________ Permit #: _____________________ Project Address: ____________________________________________________________________________ Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Description of Work, Work Schedule, Equipment Used: _____________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ Construction Company: ________________________________________ Phone/Cell: (_____) _____-________ Applicant Name: _________________________________ Email: ______________________________________ Business Address: _________________________________ City/State: __________________ Zip: __________ Approved By: _______________________________________________ Date: ________________________ Transportation Operations Engineering MFP21000326 Scott Warlick CED 1/25/2021 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 2 | Published: 1ϭ/Ϯϱ/2019 APPLICANT AGREES TO ALL THE FOLLOWING: x TCP must be approved prior to commencing the work, and all permit conditions shall be met. x Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. x Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. x The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of traffic. This includes set up within the traveled way or immediately adjacent to the roadway. x Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures. x Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. x TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT) and all traffic regulations of the City of Renton and Revised Code of Washington (RCW). x Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State and City codes. x Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Applicant’s agents and employees. x The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. x In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay for legal counsel chosen by the City to defend against same. x Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. x Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. x Approved Temporary TCP must be at the work site during work hours. x Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. x Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: x Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. x Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. x The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site. x Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street; 425-430-7423). _______________________________ _______________________________ _______________________ Applicant’s Signature Print Name Date ONE WAY222217172121parkingparkingS 3RD STSHATTUCK AVE S WHITWORTH AVE SW20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100' W20-7AROADWORKAHEADW20-1 W20-4ONE LANEROADAHEAD100'100'100'ARRW-BRDC/WCLOSEDR9-3DETOURM4-9b 17172121LEFT LANECLOSEDAHEADW20-5LW20-7A100'100'100'ROADWORKAHEADW20-1PLACE SIGN ONBOTH SIDE OFROADWAYROADWORKAHEADW20-1 ROADWORKAHEADW20-12222STOP FLAGGER STOP FLAGGER STOP FLAGGERS 3RD STRESIDENT(S) WILL BE INFORMEDOF POSSIBLE TEMPORARYDRIVEWAY CLOSUREPLACE SIGNSBOTH SIDES OFWORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK FROM TO TOW AWAY AREA PHONE 888-9999 INFRASOURCE LLC 000 0000000 NO PARKING NO-PARK TEMPORARY TRAFFIC CONTROL PLANWORK PIT28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.NProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REV12/16/2021 1011320180Whiteworth Ave S & S 3rd St, Renton, WAKali-Jamal Collins425-424-6425Kali-Jamal.Collins@pse.com1 OF 3Puget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425 ONE WAY22221717parkingparkingS 3RD STWHITWORTH AVE S MORRIS AVE parkingparkingARRW-BRDRIGHT LANECLOSEDAHEADW20-5RW20-7A100'100'100'ROADWORKAHEADW20-1PLACE SIGN ONBOTH SIDE OFROADWAY1717W20-7AROADWORKAHEADW20-1 W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'19191919STOP FLAGGER POLICEUPOROADWORKAHEADW20-1 ROADWORKAHEADW20-1C/WCLOSEDR9-3DETOURM4-9bRESIDENT(S) WILL BE INFORMEDOF POSSIBLE TEMPORARYDRIVEWAY CLOSUREPLACE SIGNSBOTH SIDES OFWORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK FROM TO TOW AWAY AREA PHONE 888-9999 INFRASOURCE LLC 000 0000000 NO PARKING NO-PARKNotes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.NProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REV12/16/2021 1011320180Whiteworth Ave S & S 3rd St, Renton, WAKali-Jamal Collins425-424-6425Kali-Jamal.Collins@pse.com2 OF 3Puget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425TEMPORARY TRAFFIC CONTROL PLANWORK PIT28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040 ONE WAY22221717parkingparkingS 3RD STWHITWORTH AVE S MORRIS AVE parkingparkingARRW-BRDRIGHT LANECLOSEDAHEADW20-5RW20-7A100'100'100'ROADWORKAHEADW20-1PLACE SIGN ONBOTH SIDE OFROADWAY1717W20-7AROADWORKAHEADW20-1 W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'19191919STOP FLAGGER POLICEUPOROADWORKAHEADW20-1 ROADWORKAHEADW20-1C/WCLOSEDR9-3DETOURM4-9bRESIDENT(S) WILL BE INFORMEDOF POSSIBLE TEMPORARYDRIVEWAY CLOSUREPLACE SIGNSBOTH SIDES OFWORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK FROM TO TOW AWAY AREA PHONE 888-9999 INFRASOURCE LLC 000 0000000 NO PARKING NO-PARKNotes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.NProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REV12/16/2021 1011320180Whiteworth Ave S & S 3rd St, Renton, WAKali-Jamal Collins425-424-6425Kali-Jamal.Collins@pse.com3 OF 3Puget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425TEMPORARY TRAFFIC CONTROL PLANWORK PIT28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040 S 3RD ST S 2ND S T ONE WAY 2121 SHATTUCK AVE SS 3RD ST 2121 2121 S 2ND ST 1111ONE WAY 1111ONE WAY 21 21 21211111 1414V01J01FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKM6-2ROADWORKAHEADW20-1 RIGHTSHOULDERCLOSEDW21-5aRW1-4L100'100'ROADWORKAHEADW20-1 ROAD WORK AHEAD W20-1100'R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bS/WCLOSEDR9-9S/W CLOSEDR9-9R9-11SIDEWALK CLOSED AHEAD DETOURM4-9ballow 12' minimumSIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 TEMPORARY TRAFFIC CONTROL PLAN WORK PIT LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB#101132018 401 Shattuck Ave S, Renton, WA 98057 11/3/2020 safaa.alneema@pse.com (425 398-6077 SHEET 1 of 11 N Puget Sound Energy Traffic Control Supervisor: Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be Work area will be (fill in locations by CL: street/avenue etc). MFP21000326 S 3RD ST S 2ND S T ONE WAY 2121 SHATTUCK AVE SS 3RD ST 2121 2121 S 2ND ST 1111ONE WAY 1111ONE WAY 21 21 21211111 1414IP01 IP02FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK M6-2ROADWORKAHEADW20-1RIGHTSHOULDERCLOSEDW21-5aRW1-4L100'100'ROAD WORK AHEAD W20-1100'R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bS/WCLOSEDR9-9R9-11SIDEWALK CLOSED AHEAD DETOURM4-9b100'ROADWORKAHEADW20-1 100' RESIDENT(S) WILL BE INFORMED OF POSSIBLE TEMPORARY DRIVEWAY CLOSURE allow 12' minimumSIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 TEMPORARY TRAFFIC CONTROL PLAN LEGEND TRENCH SIGN LOCATION TRAFFIC FLOW 28" TRAFFIC CONE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY N Puget Sound Energy Traffic Control Supervisor: Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 PSE PUGETSOUNDENERGY JOB#101132018 401 Shattuck Ave S, Renton, WA 98057 11/3/2020 safaa.alneema@pse.com (425 398-6077 SHEET 2 of 11 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be Work area will be (fill in locations by CL: street/avenue etc). MFP21000326 S 3RD PL S 3RD ST ONE WAY 2121 S 3RD ST 2411112121 2121 2121 1414PV1 V02M6-2R9-11SIDEWALKCLOSEDAHEADDETOURM4-9ballow 12' minimumROADWORKAHEADW20-1RIGHTSHOULDERCLOSEDW21-5aRW1-4L100'100'100'ROADWORKAHEADW20-1 100' ROAD WORK AHEAD W20-1100'SHATTUCK AVE SSHATTUCK AVE SR9-11SIDEWALK CLOSED AHEAD DETOURM4-9bS/W CLOSEDR9-9FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKDETOURM4-9b SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 TEMPORARY TRAFFIC CONTROL PLAN LEGEND TRENCH SIGN LOCATION TRAFFIC FLOW 28" TRAFFIC CONE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY N Puget Sound Energy Traffic Control Supervisor: Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 PSE PUGETSOUNDENERGY JOB#101132018 401 Shattuck Ave S, Renton, WA 98057 11/3/2020 safaa.alneema@pse.com (425 398-6077 SHEET 3 of 11 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be Work area will be (fill in locations by CL: street/avenue etc). MFP21000326 S 4TH ST S 3RD PL S 3RD ST SHATTUCK AVE SONE WAY 2121 S 3RD ST 2411112121 2121 12 13 11 1212 19 1212202121 1414J02V03 J03 IP03 SHATTUCK AVE SSHATTUCK AVE SSTOP FLAGGER STOP FLAGGER STOP FLAGGER M6-2 W20-7ABEPREPAREDTOSTOP W3-4 100'100'ROADWORKAHEADW20-1 RIGHT LANECLOSEDAHEADW20-5R W1-4L 100'100'100'W20-7AROAD WORK AHEAD W20-1BE PREPARED TO STOP W3-4100'100'100'ROADWORKAHEADW20-1100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 100'100'100' PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000 000 NO PARKINGNO-PA RK FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PA R K R9-11SIDEWALK CLOSED AHEAD DETOUR M4-9bS/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bRESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE EMERGENCY VEHICLES WILL BE ALLOWED TO PASS WORK ZONE. SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 TEMPORARY TRAFFIC CONTROL PLAN N Puget Sound Energy Traffic Control Supervisor: Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 PSE PUGETSOUNDENERGY JOB#101132018 401 Shattuck Ave S, Renton, WA 98057 11/3/2020 safaa.alneema@pse.com (425 398-6077 SHEET 4 of 11 TRENCH 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be Work area will be (fill in locations by CL: street/avenue etc). MFP21000326 S 4TH ST S 3RD PL S 3RD ST SHATTUCK AVE SONE WAY 2121 S 3RD ST 2411112121 2121 12 13 11 1212 19 1212202121 1414J02V03 J03 IP03 SHATTUCK AVE SSHATTUCK AVE SSTOP FLAGGER STOP FLAGGER STOP FLAGGER W20-7ABEPREPAREDTOSTOP W3-4 100'100'ROADWORKAHEADW20-1 W1-4R 100'100'W20-7AROAD WORK AHEAD W20-1BE PREPARED TO STOP W3-4100'100'100'ROADWORKAHEADW20-1100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 100'100' PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888-9999 INFRASOURCE LLC 000 0000000NO PARKINGNO-PAR K FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKR9-11SIDEWALKCLOSEDAHEADDETOURM4-9bS/WCLOSEDR9-9RIGHTKEEPR4-7BR9-11SIDEWALK CLOSED AHEAD DETOURM4-9bS/WCLOSEDR9-9 DETOURM4-9b R9-11S I DEW A L K C LO S EDAHE AD PLACE PDETOUR SIGNS AT CROSSWALK/ INTERSECTION EAST, /NORTH OF REINER AVE S & S 3RD PL. SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 TEMPORARY TRAFFIC CONTROL PLAN N Puget Sound Energy Traffic Control Supervisor: Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 PSE PUGETSOUNDENERGY JOB#101132018 401 Shattuck Ave S, Renton, WA 98057 11/3/2020 safaa.alneema@pse.com (425 398-6077 SHEET 5 of 11 TRENCH 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be Work area will be (fill in locations by CL: street/avenue etc). MFP21000326 FROM TO TOW AWAY AREA PHONE 888-9999 INFRASOURCE LLC 000 0000000 NO PARKING NO-PARKV03S 3RD PLSHATTUCK AVE S1111ONLYONLY16 15 15111111111111111111 111111S 3RD PLONLYONLY131312 24111121212121121311V03J03M6-2ROADWORKAHEADW20-1 W1-4L100'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1100'R9-11SIDEWALKCLOSEDAHEADDETOURM4-9b S/WCLOSEDR9-9R9-11SIDEWALK CLOSED AHEAD DETOUR M4-9bS 3RD PLRESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSUREEMERGENCY VEHICLES WILL BEALLOWED TO PASS WORK ZONE.TEMPORARY TRAFFIC CONTROL PLANLEGENDTRENCHSIGN LOCATIONTRAFFIC FLOW28" TRAFFIC CONEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.8. Work area will be Work area will be (fill in locationsby CL: street/avenue etc).NPuget Sound EnergyTraffic Control Supervisor:Safaa Al NeemaCard No. 012611Card Exp. 10/31/2024Safaa.alneema@pse.com(425)398-6077PSEPUGETSOUNDENERGYJOB#101132018401 Shattuck Ave S, Renton, WA 9805711/3/2020safaa.alneema@pse.com(425 398-6077SHEET 6 of 11MFP21000326 S 4TH ST S 3RD PL S 3RD ST SHATTUCK AVE SONE WAY 2121 S 3RD ST 2411112121 2121 12 1311 1212 19 1212201414J03 SHATTUCK AVE SSTOP FLAGGER M6-2 W20-7ABEPREPAREDTOSTOP W3-4 100'100'ROADWORKAHEADW20-1 RIGHT LANECLOSEDAHEADW20-5R W1-4L 100'100'100' STOP FLAGGER RIGHT KEEP R4-7B STOP FLAGGER M6-2W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W1-4L100'W20-7ABEPREPARED TO STOP W3-4100'100'100'ROADWORK AHEAD W20-1W1-4R100'STOP FLAGGERW20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'ROADWORKAHEADW20-1 100'R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bR9-11SIDEWALK CLOSED AHEAD DETOUR M4-9bSIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 TEMPORARY TRAFFIC CONTROL PLAN N Puget Sound Energy Traffic Control Supervisor: Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 PSE PUGETSOUNDENERGY JOB#101132018 401 Shattuck Ave S, Renton, WA 98057 11/3/2020 safaa.alneema@pse.com (425 398-6077 SHEET 7 of 11 TRENCH 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be Work area will be (fill in locations by CL: street/avenue etc). MFP21000326 S 4TH ST S 3RD PL SHATTUCK AVE S2411112121 12 13 11 1212 19 1515121220J04 V04 HH1 HH1A STOP FLAGGER STOP FLAGGER STOP FLAGGERW20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'ROADWORKAHEADW20-1 100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100' ROAD WORKAHEAD W20-1BEPREPAREDTO STOP W3-4100'100'2121W20-7ABE PREPARED TOSTOP W3-4100'100'M6-2ROAD WORKAHEAD W20-1RIGHT LANE CLOSED AHEAD W20-5RW1-4L100'100'100'R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bR9-11SIDEWALKCLOSEDAHEADDETOURM4-9bSIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 TEMPORARY TRAFFIC CONTROL PLAN N Puget Sound Energy Traffic Control Supervisor: Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 PSE PUGETSOUNDENERGY JOB#101132018 401 Shattuck Ave S, Renton, WA 98057 11/3/2020 safaa.alneema@pse.com (425 398-6077 SHEET 8 of 11 TRENCH 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be Work area will be (fill in locations by CL: street/avenue etc). MFP21000326 S 4TH ST S 3RD PL SHATTUCK AVE S2411112121 12 13 11 1212 19 1515121220HH1HH1A STOP FLAGGER STOP FLAGGER STOP FLAGGERW20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'ROADWORKAHEADW20-1 100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100' ROADWORK AHEAD W20-1BE PREPARED TOSTOP W3-4100'100'2121W20-7ABEPREPARED TO STOP W3-4100'100'M6-2ROAD WORK AHEAD W20-1RIGHT LANE CLOSED AHEAD W20-5RW1-4L100'100'100'R9-11SIDEWALKCLOSEDAHEAD DETOURM4-9bR9-11SIDEWALK CLOSED AHEAD DETOUR M4-9bS/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bSIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 TEMPORARY TRAFFIC CONTROL PLAN N Puget Sound Energy Traffic Control Supervisor: Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 PSE PUGETSOUNDENERGY JOB#101132018 401 Shattuck Ave S, Renton, WA 98057 11/3/2020 safaa.alneema@pse.com (425 398-6077 SHEET 9 of 11 TRENCH 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be Work area will be (fill in locations by CL: street/avenue etc). MFP21000326 S 4TH ST SHATTUCK AVE S12 13 11 1212 19 121220V05 PV2 J05 V06 S 4TH PL 21212121 2913 FROM TO TOW AWAY AREA PHONE 888-9999 INFRASOURCE LLC 000 0000000 NO PARKING NO-PARK M6-2ROAD WORK AHEAD W20-1RIGHTSHOULDER CLOSED W21-5aRW1-4L100'100'100'ROADWORKAHEADW20-1 100'ROADWORKAHEADW20-1100'R9-11SIDEWALKCLOSEDAHEAD DETOURM4-9b S/W CLOSED R9-9S/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bSIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 TEMPORARY TRAFFIC CONTROL PLAN N Puget Sound Energy Traffic Control Supervisor: Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 PSE PUGETSOUNDENERGY JOB#101132018 401 Shattuck Ave S, Renton, WA 98057 11/3/2020 safaa.alneema@pse.com (425 398-6077 SHEET 10 of 11 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be Work area will be (fill in locations by CL: street/avenue etc). LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW UG/BOX/VAULTVault WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY MFP21000326 SHATTUCK AVE SV05PV2J05V06S 4TH PL2121RAINIER AVE S171511R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bR9-11SIDEWALK CLOSED AHEAD DETOUR M4-9bS/WCLOSEDR9-9M6-2ROADWORKAHEADW20-1RIGHTSHOULDERCLOSEDW21-5aRW1-4L100'100'100'ROADWORKAHEADW20-1100'al low 11 ' m in imum ROADWORKAHEADW20-1 100'LEGENDTRENCHSIGN LOCATIONTRAFFIC FLOW28" TRAFFIC CONEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.8. Work area will be Work area will be (fill in locationsby CL: street/avenue etc).NPuget Sound EnergyTraffic Control Supervisor:Safaa Al NeemaCard No. 012611Card Exp. 10/31/2024Safaa.alneema@pse.com(425)398-6077TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB#101132018401 Shattuck Ave S, Renton, WA 9805711/3/2020safaa.alneema@pse.com(425 398-6077SHEET 11 of 11MFP21000326 N Vicinity Map Thomas Guide Page XX 101132018ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. No No No Yes Yes Yes "Flagging Required" "Outages Required" "Locates Required" RENTON DOWNTOWN UTILITY IMPROVEMENT UG RELOCATION GENERAL SPECIFICATIONS Scope of Work PSE project limits: Re-routing UG cable in conflict with proposed storm drain and water alignment. General -All work is to be completed per PSE Standards & Practices. Copies of all PSE Standards are available upon request. -Work sites shall be kept clear of debris and all construction materials; equipment and packing shall be removed daily. -Return all unused and removed poles, transformers and hardware to PSE, storeroom. All copper shall be coiled and returned the day it is removed from the poles. Remove all unused pins and insulators. -Return all streetlights, area lights and floodlights to Sumner yard. Preconstruction - Notify appropriate city, County or DOT authorities 48 to 72 hours, or as required by permitting agency, in advance of starting work in Right-of-way involving a Permit. - All system switching shall be approved by System Operations (425-882-4652) a minimum of 48 hours in advance. - Notify customers of all outages 48 hours in advance. Work Drawings & Documents - Field design changes shall be approved by PSE Project Manager or Engineer. - Mark all field changes, equipment ID numbers and Underground cable information in red on Foreman's copy of worksketch. - Return one Foreman's copy of worksketch to Project Manager at completion of job. - When permits are required, a copy shall be available on work site at all times. Safety - Refer to PSE standards 6275.3000 and 6275.6000 for system ground requirements. - Refer to PSE standards 6275.9050 for personal protective grounding requirements. - Refer to PSE standards 6275.9150 for vehicle grounding and barricading requirements. - Proper line clearances shall be taken at the beginning, and released at the end, of each work day, or as otherwise instructed by the System Operator. - Provide signs, barricades, and traffic control in conformance with permit regulations. - Utilize flagging and other vehicle traffic control as necessary and in conformance with local traffic regulations. - Maintain traffic flow as required by permitting agency. Erosion & Sediment Control - Refer to PSE standards 0150.3200 for minimum requirements. - Comply with all requirements of permitting agency. - Installed erosion & sediment devices shall be maintained until vegetation has been re-established or disturbed soil has been otherwise permanently stabilized. Joint Facilities - Coordinate with Communication Companies for transfers. OVERHEAD CONSTRUCTION Poles & Structures - Poles are to be installed or relocated as staked. Unless otherwise noted, all pole location measurements are from the center of the pole. - All new poles set shall be the class indicated on the sketch, or better. Do not set a lower class pole than specified. - Install ground plate assembly on all new poles. Install Switch Ground Assembly per standard specification 6014.1000 at new gang operated switch locations. - Install grid numbers on all new and existing poles as shown on sketch. - Straighten existing poles as indicated or as necessary. - Treat all field-drilled poles with copper napthenate wood preservative. - Remove old poles after communication companies have transferred off and return to PSE storeroom. Fill and crown pole holes and restore area similar to adjacent landscaping. Conductors & Equipment - Transfer all overhead and underground primary, secondary and service conductors and guys to new poles set, unless otherwise indicated on this sketch. - Transfer existing transformers to new poles unless otherwise indicated on this sketch. - Use stirrups to connect all overhead and underground primary taps, and all transformers. Install at all sites being worked within the scope of the project where they are currently missing. - Use 397 AAC and Ampact connectors for all bare conductor feeder jumpers and 600 amp switch jumpers. Install tree wire conductor for jumpers on all poles that are double deadended with tree wire. - Apply grit inhibitor on all Ampact, stirrup, and dead-end connections. - Connect primary taps and transformers to same phase as existing unless otherwise shown on the drawing. - All neutral connections to be made with solid compression connectors. Connect all pole grounds to common neutral. - Use Load-interrupter cutouts (with arc shields) on all primary overhead and underground taps with fused protection above 40T. - Install Wildlife Protectors on all transformers. UNDERGROUND CONSTRUCTION Excavation -Trenching outside of the Right-of-way shall be of sufficient depth to provide a minimum of 36” of cover for primary conductors and 24” of cover for secondary conductors. -Road crossings and all trenches within the Right-of-way shall be of sufficient depth to provide a minimum of 36” of cover for all conductors or as required by the permitting Agency. -All conductors/conduits shall have a minimum of 3” of bed and 3” of clean sand cover. -No rocks larger than 6” shall be included in backfill. -Backfill in road crossings and within the Right-of-way shall be compacted to 95% density or as required by the permitting Agency. -Restore all excavated areas to original condition. - If four or more six inch conduits are installed in a trench, fluidized thermal backfill (FTB) shall be installed around the conduits to a depth of six inches above and to the sides of the conduit, and two inches underneath, per PSE Standard 6790.0140. Vaults & Handholes - Refer to PSE standard 6775.0040 “Vault and Handhole Installation” - Vaults shall be placed level and 2” above final grade in landscaped areas and flush with final grade when placed in hard surface areas. - A minimum 6” bed of 5/8” crushed rock shall be placed under all vaults. - All conduit entrances shall be grouted. Conductors & Conduit - Refer to PSE standard 6800.6000 “PVC Conduit Installation”. - Unless splices are called for, or otherwise noted or approved, conduit risers shall be plumbed directly to road crossing conduits. - Install insulating caps on all unused primary bushings. - All “spare” conduits shall be capped at each end. Owner / Developer Contact Info officeATTN: Ty Tadano Ty.Tadano@murraysmith.us 600 University St Suite 300 Seattle,WA,98101 206-462-7038 206-462-7030PHONE CABLE TV 11536971 101132018 N/A N/A 108123200 PROJECT PHASE PWR NOTIF#ORDER# Superior UG Expense Removal 594137276 E-Mail: Cell Phone: Project Manager Contact Information: Manager:HONG NGUYEN 425-449-6609 Hong.Nguyen@pse.com UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Hong Nguyen 425-449-6609 9/5/20 Khader Gouesse 253-254-2896 9/5/20 N/A N/A N/A Keang Lim 253-395-6916 9/5/20 N/A CITY OF RENTON RENTON DUIP UG RELOCATION 401 SHATTUCK AVE S RENTON WA 98057 N/A N/A N/A 101132018 AS NOTED 1/7 King N/A N/A CSPSKEPI N/A N/A N/A N/A 2305E076-040-0282305E065-078-066 SEE TEXT N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) LEGEND CONDUIT RISER OVERHEAD TRANSFORMER JUNCTION VAULT/JUNCTION BOX NEW CONDUCTOR AND OR TRENCH LINE DISCONNECT - FUSED PULL VAULT OR SPLICE VAULT EXISTING POLE DOWN GUY DISCONNECT - UNFUSED NEW POLE PADMOUNT TRANSFORMER SECONDARY HANDHOLE EXISTING CONDUCTOR TO BE REMOVED OR ABANDONED STREET LIGHT TOTAL UNDERGROUND TRANSFORMER ENERGY CUSTOMER DEMAND POINT OR OR OR OVERHEAD JUMPER CONNECTION JOB SITE CIRCUIT NO: PCR-13 EAR-17 GRA-15 MFP21000326 This permit is for Major construction work in the ROW and will be billed at an additional $60/HR for inspections. After hours and weekend work will be billed at $125/HR Pre-Construction Meeting required 101132018SCALE: NONE OVERHEAD CIRCUIT MAP (2305E076) UNIVERSAL CIRCUIT MAP (2305E072) SCALE: NONE JOB SITE JOB SITE UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Hong Nguyen 425-449-6609 9/5/20 Khader Gouesse 253-254-2896 9/5/20 N/A N/A N/A Keang Lim 253-395-6916 9/5/20 N/A CITY OF RENTON RENTON DUIP UG RELOCATION 401 SHATTUCK AVE S RENTON WA 98057 N/A N/A N/A 101132018 AS NOTED 2/7 King N/A N/A CSPSKEPI N/A N/A N/A N/A 2305E076-040-0282305E065-078-066 SEE TEXT N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A CIRCUIT NO: PCR-13 EAR-17 GRA-15 MFP21000326 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••F4+00F5+00F6+00F7+00F8+00C13+0018" PP SD18" PP SD18" PP SD18" PP SD24" PP SD12"PP SD 12"PP SD 317808 165906 75kVA 120/240v 100kVA 120/240v 317808 165905 1/0 16637-A 16636-B 16635-C 1/0 ADM343-A ADM344-B ADM345-C 1/0 ADM300-A ADM301-B ADM302-C SHATTUCK AVE S"212" 317833 165906 317835 165906 100kVA 120/240v V02 EXIST PV1 EXIST EX UG FEEDERAND UG 1/0J01 EXIST MATCHLINE - STA F8+00 PAGE 3 1/0 ADF565-A ADF566-B 750 ADM259-A ADM260-B ADM261-C EAR-17ADM259-A ADM260-BPCR-13PCR-13PCR-13 V01EXIST IP01 IP02 NO S 3RD ST ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••F8+00F9+00F10+00F11+0024" PP SD24" PP SD24" PP SD24" PP SD12"PP SD 12"PP SD 12"DI S D 12"DI SD12"PP S D 317793 165921 SHATTUCK AVE SP01 EXIST X1034 EX UG FEEDER S 3RD PL "336" "220" "440" 317783 165911 1/0 ADM300-A ADM301-B ADM302-C 1/0 ADM303-A ADM304-B ADM305-C317783 165887 50kVA 120/240v 1/0 16084-A 16085-B 16086-C 317779 165898 NEW UG 1/0 EX UG 1/0 J03 EXIST V03 EXIST MATCHLINE - STA F8+00 PAGE 3 PCR-13 PCR-13 EAR-17EAR-17750 ADM259-A ADM260-B ADM261-C PCR-13PCR-13 EAR-17 EAR-17EAR-17 1/0 16081-A 16082-B 16083-C 1/0 ADM319-A ADM320-B ADM321-CEAR-17J02 EXIST IP03 ALLEYWAY MATCHLINE - STA F11+40 PAGE 4 IP04 IP05 IP06 IP07 SITE PLAN 101132018SCALE: 1" = 20' Vault & Equipment Table Site Grid Number Vault Size & Cover Type & Size Equipment In Vault Primary Bushings Transformer ID Numbers (Company ID) ASBUILT INFORMATION Foreman-Complete (Include Transformer Phase Tapped and Test Secondary Voltage)LB DC J01 317833 165906 EXISTING -3 - V01 317835 165906 EXISTING TUT 100kVA 120/240v -- PV1 317808 165905 EXISTING --- V02 317808 165906 EXISTING TUT 75kVA 120/240v 100kVA 120/240v 6 - J02 317783 165911 EXISTING -9 - V03 317783 165887 EXISTING TUT 50kVA 120/240v 3 - CABLE REMOVAL SCHEDULE CABLE NO. LOCATIONS CABLE (LF) EST CABLE TYPE YEAR INST FROM TO AØ16637-BØ16636-CØ16635 J01 V02 285 1/0 AL JKT AØADM300-BØADM301-CØADM302 V02 J02 265 AØADM303-BØADM304-CØADM305 J02 V03 160 AØADM319-BØADM320-CØADM321 J02 J04 385 Total Feet 1090 (1/0 AL JKT) ACTUAL________Removed 29 LF 12" PP SD @ SLP=1.00% 48'' SDMH #34CB #44 STA F9+24, 14' RT CB #44 TO SDMH #34 SCALE: 1"=20' HORIZ, 1"=5' VERT 38 LF 12" DI SD @ SLP=0.50% CB #46 48'' SDMH #34 STA F9+24, 14' RT 42 LF 12" PP SD @ SLP=0.50% 48'' SDMH #52 CB #46 TO SDMH #52 TO SDMH #34 SCALE: 1"=20' HORIZ, 1"=5' VERTEXIST TELEXIST 12"SD (ABAN)EXIST 2"GEXIST UGPJ02-V03 CONDUIT PROFILE EXIST 16"WEXIST 10"SSEXIST UGPEXIST TEL (2)EXIST 12"WEXIST TELEXIST UGPEXIST 12"SD (ABAN)UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Hong Nguyen 425-449-6609 9/5/20 Khader Gouesse 253-254-2896 9/5/20 N/A N/A N/A Keang Lim 253-395-6916 9/5/20 N/A CITY OF RENTON RENTON DUIP UG RELOCATION 401 SHATTUCK AVE S RENTON WA 98057 N/A N/A N/A 101132018 AS NOTED 3/7 King N/A N/A CSPSKEPI N/A N/A N/A N/A 2305E076-040-0282305E065-078-066 SEE TEXT N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A CIRCUIT NO: PCR-13 EAR-17 GRA-15 SITE NOTES IP01 INTERCEPT AND EXTEND EXISTING 2-4" CONDUIT SOUTH TO IP02 IP02 INTERCEPT AND EXTEND EXISTING 2-4" CONDUIT SOUTH TO V02 IP03 INTERCEPT AND EXTEND EXISTING 2-4" CONDUIT SOUTH TO J02 IP04 INTERCEPT AND EXTEND EXISTING 3-4" CONDUIT SOUTH TO IP05 IP05 INTERCEPT AND EXTEND EXISTING 3-4" CONDUIT SOUTH TO IP06 IP06 INTERCEPT AND EXTEND EXISTING 3-4" CONDUIT SOUTH TO IP07 IP07 INTERCEPT AND EXTEND EXISTING 3-4" CONDUIT SOUTH TO J04 MFP21000326 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••F12+00F13+00F14+00F15+0036" PP SD24" PP SD36" PP SD24"PP SD12"PP SD 12"DI SD36"PP SD12"PP SD 8"PP SD S 4TH ST "400" 1/0 58471-A 58472-B 58473-C 1/0 ADM319-A ADM320-B ADM321-C 317758 165922 500kVA 120/208v 317757 165921 1/0 ADM317-B ADM318-C SHATTUCK AVE S317727 165903 1/0 164084-A 164085-B 164086-C 1/0 ADM309-A ADM310-B ADM311-C "416" "418" "408" V04 EXIST J04 EXIST EAR-17 EAR-17HH1 HH1A 37.5kVA 120/240v 317729 165909 317730 165908 V05 EXIST PV2 EXIST MATCHLINE - STA F15+40 PAGE 4 MATCHLINE - STA F11+40 PAGE 4 IP08 1/0 ADM316-A 1/0 ADM317-B ADM318-C 1/0 ADM315-A ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••F16+00F16+8036" PP SD36" PP SD36" PP SDS 4TH PL 317703 165903 317703 165912 300kVA 120/208v 1/0 ADM312-A ADM313-B ADM314-C J05 EXIST V06 EXIST MATCHLINE - STA F15+40 PAGE 4 SITE PLAN 101132018SCALE: 1" = 20' Vault & Equipment Table Site Grid Number Vault Size & Cover Type & Size Equipment In Vault Primary Bushings Transformer ID Numbers (Company ID) ASBUILT INFORMATION Foreman-Complete (Include Transformer Phase Tapped and Test Secondary Voltage)LB DC J04 317757 165921 EXISTING 6 - PV2 317730 165908 EXISTING -- V05 317729 165909 EXISTING TUT 37.5kVA 120/240v 1 - J05 317703 165903 EXISTING 2 - CABLE REMOVAL SCHEDULE CABLE NO. LOCATIONS CABLE (LF) EST CABLE TYPE YEAR INST FROM TO AØADM316 J04 V05 362 1/0 AL JKT BØADM317-CØADM318 J04 J05 662 1/0 AL JKT Total Feet 1045 (1/0 AL JKT) ACTUAL________Removed SECONDARY HH/PEDESTAL TABLE Site Pedestal or Handhole Number of Positions Required Remarks HH1A Handhole 4 J04-IP08 CONDUIT PROFILE 44 LF 12" PP SD @ SLP=0.50% 54'' SDMH #38 STA F12+04, 17' RT CB #51 CB #51 TO SDMH #37 SCALE: 1"=20' HORIZ, 1"=5' VERT 48'' SDMH #37EXIST 12"GEXIST 10"SSEXIST TELEXIST 16"WEXIST UGPEXIST TELUTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Hong Nguyen 425-449-6609 9/5/20 Khader Gouesse 253-254-2896 9/5/20 N/A N/A N/A Keang Lim 253-395-6916 9/5/20 N/A CITY OF RENTON RENTON DUIP UG RELOCATION 401 SHATTUCK AVE S RENTON WA 98057 N/A N/A N/A 101132018 AS NOTED 4/7 King N/A N/A CSPSKEPI N/A N/A N/A N/A 2305E076-040-0282305E065-078-066 SEE TEXT N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A CIRCUIT NO: PCR-13 EAR-17 GRA-15 SINGLE PHASE SECONDARY CONCRETE HANDHOLE Not to scale 6050.2020-1 TOP VIEW SIDE VIEW 2'-4" EXCAVATION: 5-1/3 CUBIC YARDS 7'-0" 6'-0" 2" 2'-6" Install PVC bell endsand grout into wall 2'-6" Handhole 820 lbs Conduits and conductors shall enter fromends of handhole through knockouts provided Typical customer runservice conductors in duct Steel Door Seal conduitwith foam Customer-installed grounding wires ( the "4th" wire on the single-phase systems and the "5th" wire on the three-phase systems) shall not be connected to PSE's ground or neutral bus. They shall be removed by customer or cut off at the vault wall. 6" Crushed rock SITE NOTES IP08 INTERCEPT AND EXTEND EXISTING 2-4" CONDUIT NORTH TO J04 INTERCEPT AND EXTEND EXISTING 1-3" CONDUIT NORTH TO HH1A MFP21000326 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••F5+00F6+00F7+00G6+00G4+00G5+00G6+00C13+00 C14+00 C15+00 C16+00 C17+0018" PP SD18" PP SD 18" PP SD 18" PP SD 18" PP SD18" PP SD24" PP SD12" PP SD18" PP SD12" PP SD12"PP SD 12"DI SD12 " D I S D 12"DI SD12"DI SD 12"DI SD 317808 165906 75kVA 120/240v 100kVA 120/240v 317808 165905 1/0 16637-A 16636-B 16635-C 1/0 ADM343-A ADM344-B ADM345-C 317807 165925 2x25kVA 120/240v 317807 165925 1/0 ACT323-A ACT324-B S 3RD STSHATTUCK AVE S"305" "309" "212" "300"WHITWORTH AVE S25kVA 120/240v 317805 165937 1/0 AFD575-A 1/0 ADM346-A ADM347-B ADM348-C 1/0 16615-A 16616-B 16617-C 1/0 ADM353-A ADM354-B ADM355-C "319" "401" 2x25kVA 120/240v 25kVA 120/208v 317824 165939 75kVA 120/240v 317825 165939 V02 EXIST PV1 EXIST EX UG FEEDEREX UG 1/0 J06 EXIST V07 EXIST V08 EXIST V10 EXIST V09 EXIST 1/0 ADF565-A ADF566-B 750 ADM259-A ADM260-B ADM261-C EX UG 1/0PCR-13PCR-13 GRA-15NOPCR-13 OPEN-WYE/OPEN DELTA Δ/Y GRA-15 GRA-15GRAD-15IP01 IP02 IP09 NO S 3RD ST MATCHLINE - STA C17+80PAGE 5••••••••••••••••••••••••••••••••••••••••••••••••••••••H5+00H6+00C18+00 C19+00 C20+00 18" PP SD 12" PP SD 12" C900 SD18" PP SD 12" PP SD12"DI SD 12"DI SD 25kVA 120/240v 317804 165965 "505" S 3RD ST MORRIS AVE SV11 EXIST GRA-15 GRA-15MATCHLINE - STA C17+80PAGE 5SITE PLAN 101132018SCALE: 1" = 20' Vault & Equipment Table Site Grid Number Vault Size & Cover Type & Size Equipment In Vault Primary Bushings Transformer ID Numbers (Company ID) ASBUILT INFORMATION Foreman-Complete (Include Transformer Phase Tapped and Test Secondary Voltage)LB DC V08 317805 165937 COMBO VAULT TUT 25kVA 120/240v 6 - V09 317824 165939 EXISTING TUT 2X25kVA 120/240v 1X25kVA 120/208v 3 - V11 317804 165965 EXISTING TUT 25kVA 120/240v 3 - V08-V11 CONDUIT PROFILE CB #27 48'' SDMH #23 STA C18+53, 16' LT 5 LF 12" PP SD @ SLP=0.37%CB #28 37 LF 12" DI SD @ SLP=0.52% CB #27 TO CB #28 TO SDMH #23 SCALE: 1"=20' HORIZ, 1"=5' VERT CB #24 45 LF 12" DI SD @ SLP=0.51% 48'' SDMH #21 STA C16+03, 19' LT SDMH #21 TO CB #24 SCALE: 1"=20' HORIZ, 1"=5' VERT CB #25 39 LF 12" DI SD @ SLP=0.49% 48'' SDMH #22 STA C17+23, 18' LT CB #26 CB #26 TO CB #25 TO SDMH #22 SCALE: 1"=20' HORIZ, 1"=5' VERTEXIST 12"WEXIST UGPPROP SSEXIST 4"GEXIST 12"WPROP SSEXIST 4"GEXIST 12"WEXIST UGPPROP 24"SSEXIST 4"GCB #24 45 LF 12" DI SD @ SLP=0.51% 48'' SDMH #21 STA C16+03, 19' LT SDMH #21 TO CB #24 SCALE: 1"=20' HORIZ, 1"=5' VERTEXIST 12"WEXIST UGPPROP 24"SSEXIST 4"GV08-IP09 CONDUIT PROFILE 30 LF 12" DI SD @ SLP=0.51% CB #22 48'' SDMH #20 STA G5+19, 10' LT 5 LF 12" PP SD @ SLP=5.00% CB #23 CB #22 TO CB #23 TO SDMH #20 SCALE: 1"=20' HORIZ, 1"=5' VERTEXIST 2"GEXIST W (ABAN)EXIST 12"WPROP 8" SS &EXIST 8" SS CABLE REMOVAL SCHEDULE CABLE NO. LOCATIONS CABLE (LF) EST CABLE TYPE YEAR INST FROM TO AØ16615-BØ16616-CØ16617 V08 V09 220 1/0 AL JKT AØADM353-BØADM354-CØADM355 V08 V11 345 1/0 AL JKT Total Feet 565 (1/0 AL JKT) ACTUAL________Removed UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Hong Nguyen 425-449-6609 9/5/20 Khader Gouesse 253-254-2896 9/5/20 N/A N/A N/A Keang Lim 253-395-6916 9/5/20 N/A CITY OF RENTON RENTON DUIP UG RELOCATION 401 SHATTUCK AVE S RENTON WA 98057 N/A N/A N/A 101132018 AS NOTED 5/7 King N/A N/A CSPSKEPI N/A N/A N/A N/A 2305E076-040-0282305E065-078-066 SEE TEXT N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A CIRCUIT NO: PCR-13 EAR-17 GRA-15 MFP21000326 "300" J01 EXIST V01 EXIST V02 EXIST PV01 EXIST NO J02 EXIST V03 EXIST J05 EXIST V06 EXIST PV02 EXIST V05 EXISTSHATTUCK AVE SS 3RD ST WHITWORTH AVE SS 3RD ST MORRIS AVE SV08 EXIST V09 EXIST V10 EXIST P01 EXIST NO SHATTUCK AVE SALLEY WAY S 3RD PL J04 EXIST V04 EXIST S 4TH ST S 4TH PL HH1A NEW 2-4" IP01 IP02 IP03 NEW 2-4" NEW 1-4" IP08 NEW 1-4" NEW 1-4" NEW 1-3" NEW 1-4" IP04 IP05 NEW 1-4" IP06 IP07 IP09 NEW 2-4" V11 EXIST J03 EXIST 101132018CONDUIT DIAGRAM SCALE: NOT TO SCALE UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Hong Nguyen 425-449-6609 9/5/20 Khader Gouesse 253-254-2896 9/5/20 N/A N/A N/A Keang Lim 253-395-6916 9/5/20 N/A CITY OF RENTON RENTON DUIP UG RELOCATION 401 SHATTUCK AVE S RENTON WA 98057 N/A N/A N/A 101132018 AS NOTED 6/7 King N/A N/A CSPSKEPI N/A N/A N/A N/A 2305E076-040-0282305E065-078-066 SEE TEXT N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A CIRCUIT NO: PCR-13 EAR-17 GRA-15 Primary Cable & Conduit Table (Foreman to Complete) LOCATION CONDUIT PRIMARY CABLE AS BUILT INFORMATION From To Size (in) Qty Design Length (ft) Actual Length (ft) TYPE BENDS PULL (lbs) PULL Rev (lbs) Cable Size Design Length (ft) Actual Length (ft) CABLE NUMBERS MANUFACTURING INFORMATION DB120 HDPE SCH 80 90°45°22°11°A B C Manufacturer Compound Year Actual Amount Installed (Conduit & Cable) IP01 IP02 4 2 31 X 2 CONDUIT ONLY J01 V02 CABLE ONLY 1/0 JKT 285 EIT750 EIT751 EIT752 IP03 J02 4 2 11 X 2 CONDUIT ONLY V02 J02 1/0 JKT 265 EIT753 EIT754 EIT755 J02 V03 4 1 140 X 1/0 JKT 160 EIT756 EIT757 EIT758 IP04 IP05 4 1 32 X 2 CONDUIT ONLY IP06 IP07 4 1 32 X 2 CONDUIT ONLY J02 J04 CABLE ONLY 1/0 JKT 385 EIT759 EIT760 EIT761 J04 IP08 4 1 155 X 1 CONDUIT ONLY 4 1 155 X 1 CONDUIT ONLY J04 V05 CABLE ONLY 1/0 JKT 362 EIT762 J04 J05 CABLE ONLY 1/0 JKT 662 EIT763 EIT764 V08 IP09 4 2 84 X 1 CONDUIT ONLY V08 V09 CABLE ONLY 1/0 JKT 220 EIT765 EIT766 EIT767 V08 V11 4 2 335 X 1 1 1/0 JKT 355 EIT768 EIT769 EIT770 TOTAL 4 943 -X 6 14 -1/0 JKT 2694 - MFP21000326 "300" J01 EXIST V01 EXIST V02 EXIST PV01 EXIST NO J02 EXISTV03 EXIST J05 EXIST V06 EXIST PV02 EXIST V05 EXISTSHATTUCK AVE SS 3RD ST WHITWORTH AVE SMORRIS AVE SV08 EXIST V09 EXIST V10 EXIST P01 EXIST NO SHATTUCK AVE SALLEY WAY S 3RD PL J04 EXIST V04 EXIST S 4TH ST S 4TH PL HH1A EXIST 1/0 ACT323-A ACT234-B NEW 1/0 EIT756-A EIT757-B EIT758-C NEW 1/0 EIT763-B EIT764-C NEWUG 350 TPLX NEW 1/0 EIT750-A EIT751-B EIT752-C NEW 1/0 EIT753-A EIT754-B EIT755-C EXIST1/0 ADM286-A ADM287-B ADM288-C EXIST1/0 ABR953-A ABR952-B ABR951-C EXST1/0 ADM292-A EXIST1/0 AED206-B NEW 1/0 EIT759-A EIT760-B EIT761-C NEW 1/0 EIT762-A EXIST1/0 58471-A 58472-B 58473-C 1/0 ADM323-A ADM324-B ADM325-C EXIST1/0 AED207-A NEW 1/0 EIT765-A EIT766-B EIT767-C NEW 1/0 EIT768-A EIT769-B EIT770-C EXIST 1/0 ADM343-A ADM344-B ADM345-C EXIST 1/0 ADM346-A ADM347-B ADM348-C EXIST 1/0 EHH400-A EHH401-B EHH402-C EXIST 1/0 AFD575-A EXIST 1/0 16605-A 16606-B 16607-C EXIST 1/0 16606-B EXIST 1/0 ADL889-A ADL890-B ADL891-C EXIST 1/0 ADM352-A V11 EXIST J03 EXIST EXIST1/0 16081-A 16082-B 16083-C EXIST 1/0 ADM15-A PCR-13PCR-13GRA-15GRA-15 GRA-15EAR-17PCR-13EAR-17 EAR-17EAR-17EAR-17EAR-17EAR-17101132018CABLE DIAGRAM SCALE: NOT TO SCALE UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Hong Nguyen 425-449-6609 9/5/20 Khader Gouesse 253-254-2896 9/5/20 N/A N/A N/A Keang Lim 253-395-6916 9/5/20 N/A CITY OF RENTON RENTON DUIP UG RELOCATION 401 SHATTUCK AVE S RENTON WA 98057 N/A N/A N/A 101132018 AS NOTED 7/7 King N/A N/A CSPSKEPI N/A N/A N/A N/A 2305E076-040-0282305E065-078-066 SEE TEXT N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A CIRCUIT NO: PCR-13 EAR-17 GRA-15 MFP21000326