HomeMy WebLinkAboutMFP21000326.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Major Franchise Permit: MFP21000326
IVR Number: 21000326
Permit Information
Permit Name: Puget Sound Energy - Electric
Address/Location:01/22/2021Application Date:3340401606Parcel Number: 1401 SHATTUCK AVE S
Permit Type:01/25/2021Issue Date:Franchise
Permit Work Class:01/25/2022Expiration Date:Major Utility
Job Number: 101132018Franchise Type:Electric
Description: Puget Sound Energy Electric **DUIP** CREW TO RE REOUTE UG CABLE IN CONFLICT WTIH THE NEW STORM
AND WATER ALIGNMENT. PRE CONSTRUCTION MEETING REQUIRED. RESTORATION PER CITY OF RENTON
STANDARDS.
Contacts
Name Address PhoneTypeBilling
Corrie Rydberg
Puget Sound Energy
6905 S 228TH St
KENT, WA 98032
C: (253) 905-5031ApplicantX
Carli Bunkelman
PSE/POTELCO - Billing
6905 S 228th St
Kent, WA 98032
B: (253) 437-6708Contractor
Business License Number: 5109Construction Contractor: POTELI*227PL
WSDOT -REAL ESTATE SERVICES PO BOX 330310 #MS118
SEATTLE , WA 98133
Owner
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF PUBLIC WORKS
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 1 of 2 | Published: 1ϭ/Ϯϱ/2019
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN (TCP) APPLICATION
Published: 1ϭ/Ϯϱ/2019
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and
obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
TO THE APPLICANT: Submit the TCP application form and required submittal documents to
TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address.
The following items, electronic copies preferred, are all required for submittal of the TCP Application:
1.܆ A copy of the Traffic Control Plan (TCP) Application form.
2.܆ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall:
܆ Include map(s) showing the location of the project and work area.
܆ Be legible lettering and clear, contrasting, symbols of viewing or printing.
܆ Must indicate street names, and north arrow and scale.
܆ All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State
Traffic Control Flagger Certification handbook, by the Evergreen Safety Council.
܆ Types of plans required:
܆ Work hour plan – show all mobility impacts during construction hours.
܆ Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
܆ Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
܆ Pedestrian access/detour plan, if applicable.
Project Name: ______________________________________________ Permit #: _____________________
Project Address: ____________________________________________________________________________
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Description of Work, Work Schedule, Equipment Used: _____________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
Construction Company: ________________________________________ Phone/Cell: (_____) _____-________
Applicant Name: _________________________________ Email: ______________________________________
Business Address: _________________________________ City/State: __________________ Zip: __________
Approved By: _______________________________________________ Date: ________________________
Transportation Operations Engineering
MFP21000326
Scott Warlick CED 1/25/2021
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 2 | Published: 1ϭ/Ϯϱ/2019
APPLICANT AGREES TO ALL THE FOLLOWING:
x TCP must be approved prior to commencing the work, and all permit conditions shall be met.
x Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner
at a time, with the least possible inconvenience or delay to pedestrians.
x Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or
slippery road conditions during work and non-work hours.
x The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of
traffic. This includes set up within the traveled way or immediately adjacent to the roadway.
x Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures.
x Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including
public transit, to be affected by a temporary lane or road closure.
x TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on
Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT)
and all traffic regulations of the City of Renton and Revised Code of Washington (RCW).
x Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or
Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State
and City codes.
x Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles
and the acts of the Applicant’s agents and employees.
x The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and
in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s
reasonable attorney’s fees and litigation costs incurred resulting from such claim.
x In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay
for legal counsel chosen by the City to defend against same.
x Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
x Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
x Approved Temporary TCP must be at the work site during work hours.
x Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
x Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
x Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations
for vacate parking or curb lane usage.
x Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
x The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site.
x Temporary traffic control devices must be removed immediately when work is done or no construction
activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance
shop (3555 NE 2nd Street; 425-430-7423).
_______________________________ _______________________________ _______________________
Applicant’s Signature Print Name Date
ONE WAY222217172121parkingparkingS 3RD STSHATTUCK AVE S
WHITWORTH AVE SW20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'
W20-7AROADWORKAHEADW20-1
W20-4ONE LANEROADAHEAD100'100'100'ARRW-BRDC/WCLOSEDR9-3DETOURM4-9b
17172121LEFT LANECLOSEDAHEADW20-5LW20-7A100'100'100'ROADWORKAHEADW20-1PLACE SIGN ONBOTH SIDE OFROADWAYROADWORKAHEADW20-1 ROADWORKAHEADW20-12222STOP
FLAGGER STOP
FLAGGER
STOP
FLAGGERS 3RD STRESIDENT(S) WILL BE INFORMEDOF POSSIBLE TEMPORARYDRIVEWAY CLOSUREPLACE SIGNSBOTH SIDES OFWORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK
FROM TO
TOW AWAY AREA
PHONE 888-9999
INFRASOURCE LLC 000 0000000
NO PARKING
NO-PARK TEMPORARY TRAFFIC CONTROL PLANWORK PIT28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.NProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REV12/16/2021 1011320180Whiteworth Ave S & S 3rd St, Renton, WAKali-Jamal Collins425-424-6425Kali-Jamal.Collins@pse.com1 OF 3Puget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425
ONE WAY22221717parkingparkingS 3RD STWHITWORTH AVE S
MORRIS AVE
parkingparkingARRW-BRDRIGHT LANECLOSEDAHEADW20-5RW20-7A100'100'100'ROADWORKAHEADW20-1PLACE SIGN ONBOTH SIDE OFROADWAY1717W20-7AROADWORKAHEADW20-1
W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'19191919STOP
FLAGGER POLICEUPOROADWORKAHEADW20-1 ROADWORKAHEADW20-1C/WCLOSEDR9-3DETOURM4-9bRESIDENT(S) WILL BE INFORMEDOF POSSIBLE TEMPORARYDRIVEWAY CLOSUREPLACE SIGNSBOTH SIDES OFWORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK
FROM TO
TOW AWAY AREA
PHONE 888-9999
INFRASOURCE LLC 000 0000000
NO PARKING
NO-PARKNotes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.NProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REV12/16/2021 1011320180Whiteworth Ave S & S 3rd St, Renton, WAKali-Jamal Collins425-424-6425Kali-Jamal.Collins@pse.com2 OF 3Puget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425TEMPORARY TRAFFIC CONTROL PLANWORK PIT28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040
ONE WAY22221717parkingparkingS 3RD STWHITWORTH AVE S
MORRIS AVE
parkingparkingARRW-BRDRIGHT LANECLOSEDAHEADW20-5RW20-7A100'100'100'ROADWORKAHEADW20-1PLACE SIGN ONBOTH SIDE OFROADWAY1717W20-7AROADWORKAHEADW20-1
W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'19191919STOP
FLAGGER POLICEUPOROADWORKAHEADW20-1 ROADWORKAHEADW20-1C/WCLOSEDR9-3DETOURM4-9bRESIDENT(S) WILL BE INFORMEDOF POSSIBLE TEMPORARYDRIVEWAY CLOSUREPLACE SIGNSBOTH SIDES OFWORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK
FROM TO
TOW AWAY AREA
PHONE 888-9999
INFRASOURCE LLC 000 0000000
NO PARKING
NO-PARKNotes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.NProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REV12/16/2021 1011320180Whiteworth Ave S & S 3rd St, Renton, WAKali-Jamal Collins425-424-6425Kali-Jamal.Collins@pse.com3 OF 3Puget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425TEMPORARY TRAFFIC CONTROL PLANWORK PIT28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040
S 3RD ST
S 2ND
S
T
ONE WAY
2121 SHATTUCK AVE SS 3RD ST
2121
2121
S 2ND ST
1111ONE WAY
1111ONE WAY
21 21
21211111
1414V01J01FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKM6-2ROADWORKAHEADW20-1
RIGHTSHOULDERCLOSEDW21-5aRW1-4L100'100'ROADWORKAHEADW20-1
ROAD
WORK
AHEAD W20-1100'R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bS/WCLOSEDR9-9S/W
CLOSEDR9-9R9-11SIDEWALK
CLOSED
AHEAD
DETOURM4-9ballow 12' minimumSIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
TEMPORARY TRAFFIC CONTROL PLAN
WORK PIT
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
PSE PUGETSOUNDENERGY
JOB#101132018
401 Shattuck Ave S, Renton, WA 98057
11/3/2020
safaa.alneema@pse.com
(425 398-6077
SHEET 1 of 11
N
Puget Sound Energy
Traffic Control Supervisor:
Safaa Al Neema
Card No. 012611
Card Exp. 10/31/2024
Safaa.alneema@pse.com
(425)398-6077
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be Work area will be (fill in locations
by CL: street/avenue etc).
MFP21000326
S 3RD ST
S 2ND
S
T
ONE WAY
2121 SHATTUCK AVE SS 3RD ST
2121
2121
S 2ND ST
1111ONE WAY
1111ONE WAY
21 21
21211111
1414IP01
IP02FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK M6-2ROADWORKAHEADW20-1RIGHTSHOULDERCLOSEDW21-5aRW1-4L100'100'ROAD
WORK
AHEAD W20-1100'R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bS/WCLOSEDR9-9R9-11SIDEWALK
CLOSED
AHEAD
DETOURM4-9b100'ROADWORKAHEADW20-1
100'
RESIDENT(S) WILL BE INFORMED
OF POSSIBLE TEMPORARY
DRIVEWAY CLOSURE allow 12' minimumSIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
TEMPORARY TRAFFIC CONTROL PLAN
LEGEND
TRENCH
SIGN LOCATION
TRAFFIC FLOW
28" TRAFFIC CONE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
N
Puget Sound Energy
Traffic Control Supervisor:
Safaa Al Neema
Card No. 012611
Card Exp. 10/31/2024
Safaa.alneema@pse.com
(425)398-6077 PSE PUGETSOUNDENERGY
JOB#101132018
401 Shattuck Ave S, Renton, WA 98057
11/3/2020
safaa.alneema@pse.com
(425 398-6077
SHEET 2 of 11
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be Work area will be (fill in locations
by CL: street/avenue etc).
MFP21000326
S 3RD PL
S 3RD ST
ONE WAY
2121
S 3RD ST
2411112121
2121
2121
1414PV1 V02M6-2R9-11SIDEWALKCLOSEDAHEADDETOURM4-9ballow 12' minimumROADWORKAHEADW20-1RIGHTSHOULDERCLOSEDW21-5aRW1-4L100'100'100'ROADWORKAHEADW20-1
100'
ROAD
WORK
AHEAD W20-1100'SHATTUCK AVE SSHATTUCK AVE SR9-11SIDEWALK
CLOSED
AHEAD
DETOURM4-9bS/W
CLOSEDR9-9FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKDETOURM4-9b
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
TEMPORARY TRAFFIC CONTROL PLAN
LEGEND
TRENCH
SIGN LOCATION
TRAFFIC FLOW
28" TRAFFIC CONE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
N
Puget Sound Energy
Traffic Control Supervisor:
Safaa Al Neema
Card No. 012611
Card Exp. 10/31/2024
Safaa.alneema@pse.com
(425)398-6077 PSE PUGETSOUNDENERGY
JOB#101132018
401 Shattuck Ave S, Renton, WA 98057
11/3/2020
safaa.alneema@pse.com
(425 398-6077
SHEET 3 of 11
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be Work area will be (fill in locations
by CL: street/avenue etc).
MFP21000326
S 4TH ST
S 3RD PL
S 3RD ST
SHATTUCK AVE SONE WAY
2121
S 3RD ST
2411112121
2121
12
13
11
1212 19 1212202121
1414J02V03
J03
IP03
SHATTUCK AVE SSHATTUCK AVE SSTOP
FLAGGER
STOP
FLAGGER
STOP
FLAGGER
M6-2
W20-7ABEPREPAREDTOSTOP
W3-4
100'100'ROADWORKAHEADW20-1 RIGHT LANECLOSEDAHEADW20-5R
W1-4L
100'100'100'W20-7AROAD
WORK
AHEAD W20-1BE
PREPARED
TO
STOP W3-4100'100'100'ROADWORKAHEADW20-1100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4
100'100'100'
PLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC
000
0000
000 NO PARKINGNO-PA
RK FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PA
R
K
R9-11SIDEWALK
CLOSED
AHEAD
DETOUR M4-9bS/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bRESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
EMERGENCY VEHICLES WILL BE
ALLOWED TO PASS WORK ZONE.
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
TEMPORARY TRAFFIC CONTROL PLAN
N
Puget Sound Energy
Traffic Control Supervisor:
Safaa Al Neema
Card No. 012611
Card Exp. 10/31/2024
Safaa.alneema@pse.com
(425)398-6077
PSE PUGETSOUNDENERGY
JOB#101132018
401 Shattuck Ave S, Renton, WA 98057
11/3/2020
safaa.alneema@pse.com
(425 398-6077
SHEET 4 of 11
TRENCH
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be Work area will be (fill in locations
by CL: street/avenue etc).
MFP21000326
S 4TH ST
S 3RD PL
S 3RD ST
SHATTUCK AVE SONE WAY
2121
S 3RD ST
2411112121
2121
12
13
11
1212 19 1212202121
1414J02V03
J03
IP03
SHATTUCK AVE SSHATTUCK AVE SSTOP
FLAGGER
STOP
FLAGGER
STOP
FLAGGER
W20-7ABEPREPAREDTOSTOP
W3-4
100'100'ROADWORKAHEADW20-1 W1-4R
100'100'W20-7AROAD
WORK
AHEAD W20-1BE
PREPARED
TO
STOP W3-4100'100'100'ROADWORKAHEADW20-1100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4
100'100'
PLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999
INFRASOURCE
LLC
000
0000000NO PARKINGNO-PAR
K FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKR9-11SIDEWALKCLOSEDAHEADDETOURM4-9bS/WCLOSEDR9-9RIGHTKEEPR4-7BR9-11SIDEWALK
CLOSED
AHEAD
DETOURM4-9bS/WCLOSEDR9-9
DETOURM4-9b R9-11S
I
DEW
A
L
K
C
LO
S
EDAHE
AD
PLACE PDETOUR SIGNS
AT CROSSWALK/
INTERSECTION EAST,
/NORTH OF REINER AVE S
& S 3RD PL.
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
TEMPORARY TRAFFIC CONTROL PLAN
N
Puget Sound Energy
Traffic Control Supervisor:
Safaa Al Neema
Card No. 012611
Card Exp. 10/31/2024
Safaa.alneema@pse.com
(425)398-6077
PSE PUGETSOUNDENERGY
JOB#101132018
401 Shattuck Ave S, Renton, WA 98057
11/3/2020
safaa.alneema@pse.com
(425 398-6077
SHEET 5 of 11
TRENCH
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be Work area will be (fill in locations
by CL: street/avenue etc).
MFP21000326
FROM TO
TOW AWAY AREA
PHONE 888-9999
INFRASOURCE LLC 000 0000000
NO PARKING
NO-PARKV03S 3RD PLSHATTUCK AVE S1111ONLYONLY16 15 15111111111111111111 111111S 3RD PLONLYONLY131312
24111121212121121311V03J03M6-2ROADWORKAHEADW20-1 W1-4L100'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1100'R9-11SIDEWALKCLOSEDAHEADDETOURM4-9b
S/WCLOSEDR9-9R9-11SIDEWALK
CLOSED
AHEAD
DETOUR M4-9bS 3RD PLRESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSUREEMERGENCY VEHICLES WILL BEALLOWED TO PASS WORK ZONE.TEMPORARY TRAFFIC CONTROL PLANLEGENDTRENCHSIGN LOCATIONTRAFFIC FLOW28" TRAFFIC CONEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.8. Work area will be Work area will be (fill in locationsby CL: street/avenue etc).NPuget Sound EnergyTraffic Control Supervisor:Safaa Al NeemaCard No. 012611Card Exp. 10/31/2024Safaa.alneema@pse.com(425)398-6077PSEPUGETSOUNDENERGYJOB#101132018401 Shattuck Ave S, Renton, WA 9805711/3/2020safaa.alneema@pse.com(425 398-6077SHEET 6 of 11MFP21000326
S 4TH ST
S 3RD PL
S 3RD ST
SHATTUCK AVE SONE WAY
2121
S 3RD ST
2411112121
2121
12 1311
1212 19 1212201414J03 SHATTUCK AVE SSTOP
FLAGGER
M6-2
W20-7ABEPREPAREDTOSTOP
W3-4
100'100'ROADWORKAHEADW20-1 RIGHT LANECLOSEDAHEADW20-5R
W1-4L
100'100'100'
STOP
FLAGGER
RIGHT
KEEP
R4-7B
STOP
FLAGGER M6-2W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W1-4L100'W20-7ABEPREPARED
TO
STOP W3-4100'100'100'ROADWORK
AHEAD W20-1W1-4R100'STOP
FLAGGERW20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'ROADWORKAHEADW20-1
100'R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bR9-11SIDEWALK
CLOSED
AHEAD
DETOUR M4-9bSIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
TEMPORARY TRAFFIC CONTROL PLAN
N
Puget Sound Energy
Traffic Control Supervisor:
Safaa Al Neema
Card No. 012611
Card Exp. 10/31/2024
Safaa.alneema@pse.com
(425)398-6077 PSE PUGETSOUNDENERGY
JOB#101132018
401 Shattuck Ave S, Renton, WA 98057
11/3/2020
safaa.alneema@pse.com
(425 398-6077
SHEET 7 of 11
TRENCH
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be Work area will be (fill in locations
by CL: street/avenue etc).
MFP21000326
S 4TH ST
S 3RD PL
SHATTUCK AVE S2411112121
12
13
11
1212 19
1515121220J04
V04
HH1 HH1A
STOP
FLAGGER
STOP
FLAGGER
STOP
FLAGGERW20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'ROADWORKAHEADW20-1
100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'
ROAD
WORKAHEAD W20-1BEPREPAREDTO
STOP W3-4100'100'2121W20-7ABE
PREPARED
TOSTOP W3-4100'100'M6-2ROAD
WORKAHEAD W20-1RIGHT LANE
CLOSED
AHEAD W20-5RW1-4L100'100'100'R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bR9-11SIDEWALKCLOSEDAHEADDETOURM4-9bSIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
TEMPORARY TRAFFIC CONTROL PLAN
N
Puget Sound Energy
Traffic Control Supervisor:
Safaa Al Neema
Card No. 012611
Card Exp. 10/31/2024
Safaa.alneema@pse.com
(425)398-6077 PSE PUGETSOUNDENERGY
JOB#101132018
401 Shattuck Ave S, Renton, WA 98057
11/3/2020
safaa.alneema@pse.com
(425 398-6077
SHEET 8 of 11
TRENCH
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be Work area will be (fill in locations
by CL: street/avenue etc).
MFP21000326
S 4TH ST
S 3RD PL
SHATTUCK AVE S2411112121
12
13
11
1212 19
1515121220HH1HH1A
STOP
FLAGGER
STOP
FLAGGER
STOP
FLAGGERW20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'ROADWORKAHEADW20-1
100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'
ROADWORK
AHEAD W20-1BE
PREPARED
TOSTOP W3-4100'100'2121W20-7ABEPREPARED
TO
STOP W3-4100'100'M6-2ROAD
WORK
AHEAD W20-1RIGHT LANE
CLOSED
AHEAD W20-5RW1-4L100'100'100'R9-11SIDEWALKCLOSEDAHEAD DETOURM4-9bR9-11SIDEWALK
CLOSED
AHEAD
DETOUR M4-9bS/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bSIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
TEMPORARY TRAFFIC CONTROL PLAN
N
Puget Sound Energy
Traffic Control Supervisor:
Safaa Al Neema
Card No. 012611
Card Exp. 10/31/2024
Safaa.alneema@pse.com
(425)398-6077 PSE PUGETSOUNDENERGY
JOB#101132018
401 Shattuck Ave S, Renton, WA 98057
11/3/2020
safaa.alneema@pse.com
(425 398-6077
SHEET 9 of 11
TRENCH
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be Work area will be (fill in locations
by CL: street/avenue etc).
MFP21000326
S 4TH ST
SHATTUCK AVE S12
13
11
1212 19 121220V05
PV2
J05 V06
S 4TH PL
21212121
2913 FROM TO
TOW AWAY AREA
PHONE 888-9999
INFRASOURCE LLC 000 0000000
NO PARKING
NO-PARK
M6-2ROAD
WORK
AHEAD W20-1RIGHTSHOULDER
CLOSED
W21-5aRW1-4L100'100'100'ROADWORKAHEADW20-1
100'ROADWORKAHEADW20-1100'R9-11SIDEWALKCLOSEDAHEAD DETOURM4-9b
S/W
CLOSED R9-9S/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bSIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
TEMPORARY TRAFFIC CONTROL PLAN
N
Puget Sound Energy
Traffic Control Supervisor:
Safaa Al Neema
Card No. 012611
Card Exp. 10/31/2024
Safaa.alneema@pse.com
(425)398-6077 PSE PUGETSOUNDENERGY
JOB#101132018
401 Shattuck Ave S, Renton, WA 98057
11/3/2020
safaa.alneema@pse.com
(425 398-6077
SHEET 10 of 11
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be Work area will be (fill in locations
by CL: street/avenue etc).
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
UG/BOX/VAULTVault
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
MFP21000326
SHATTUCK AVE SV05PV2J05V06S 4TH
PL2121RAINIER AVE S171511R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bR9-11SIDEWALK
CLOSED
AHEAD
DETOUR
M4-9bS/WCLOSEDR9-9M6-2ROADWORKAHEADW20-1RIGHTSHOULDERCLOSEDW21-5aRW1-4L100'100'100'ROADWORKAHEADW20-1100'al
low 11
' m
in
imum
ROADWORKAHEADW20-1
100'LEGENDTRENCHSIGN LOCATIONTRAFFIC FLOW28" TRAFFIC CONEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.8. Work area will be Work area will be (fill in locationsby CL: street/avenue etc).NPuget Sound EnergyTraffic Control Supervisor:Safaa Al NeemaCard No. 012611Card Exp. 10/31/2024Safaa.alneema@pse.com(425)398-6077TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB#101132018401 Shattuck Ave S, Renton, WA 9805711/3/2020safaa.alneema@pse.com(425 398-6077SHEET 11 of 11MFP21000326
N
Vicinity Map
Thomas Guide Page XX
101132018ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
No
No
No
Yes
Yes
Yes
"Flagging Required"
"Outages Required"
"Locates Required"
RENTON DOWNTOWN
UTILITY IMPROVEMENT
UG RELOCATION
GENERAL SPECIFICATIONS
Scope of Work
PSE project limits: Re-routing UG cable in conflict with proposed storm drain and
water alignment.
General
-All work is to be completed per PSE Standards & Practices. Copies of all PSE
Standards are available upon request.
-Work sites shall be kept clear of debris and all construction materials; equipment
and packing shall be removed daily.
-Return all unused and removed poles, transformers and hardware to PSE,
storeroom. All copper shall be coiled and returned the day it is removed from the
poles. Remove all unused pins and insulators.
-Return all streetlights, area lights and floodlights to Sumner yard.
Preconstruction
- Notify appropriate city, County or DOT authorities 48 to 72 hours, or as required by
permitting agency, in advance of starting work in Right-of-way involving a Permit.
- All system switching shall be approved by System Operations (425-882-4652) a
minimum of 48 hours in advance.
- Notify customers of all outages 48 hours in advance.
Work Drawings & Documents
- Field design changes shall be approved by PSE Project Manager or Engineer.
- Mark all field changes, equipment ID numbers and Underground cable information in
red on Foreman's copy of worksketch.
- Return one Foreman's copy of worksketch to Project Manager at completion of job.
- When permits are required, a copy shall be available on work site at all times.
Safety
- Refer to PSE standards 6275.3000 and 6275.6000 for system ground requirements.
- Refer to PSE standards 6275.9050 for personal protective grounding requirements.
- Refer to PSE standards 6275.9150 for vehicle grounding and barricading
requirements.
- Proper line clearances shall be taken at the beginning, and released at the end, of
each work day, or as otherwise instructed by the System Operator.
- Provide signs, barricades, and traffic control in conformance with permit regulations.
- Utilize flagging and other vehicle traffic control as necessary and in conformance with
local traffic regulations.
- Maintain traffic flow as required by permitting agency.
Erosion & Sediment Control
- Refer to PSE standards 0150.3200 for minimum requirements.
- Comply with all requirements of permitting agency.
- Installed erosion & sediment devices shall be maintained until vegetation has been
re-established or disturbed soil has been otherwise permanently stabilized.
Joint Facilities
- Coordinate with Communication Companies for transfers.
OVERHEAD CONSTRUCTION
Poles & Structures
- Poles are to be installed or relocated as staked. Unless otherwise noted, all pole
location measurements are from the center of the pole.
- All new poles set shall be the class indicated on the sketch, or better. Do not set a
lower class pole than specified.
- Install ground plate assembly on all new poles. Install Switch Ground Assembly per
standard specification 6014.1000 at new gang operated switch locations.
- Install grid numbers on all new and existing poles as shown on sketch.
- Straighten existing poles as indicated or as necessary.
- Treat all field-drilled poles with copper napthenate wood preservative.
- Remove old poles after communication companies have transferred off and return to
PSE storeroom. Fill and crown pole holes and restore area similar to adjacent
landscaping.
Conductors & Equipment
- Transfer all overhead and underground primary, secondary and service conductors
and guys to new poles set, unless otherwise indicated on this sketch.
- Transfer existing transformers to new poles unless otherwise indicated on this sketch.
- Use stirrups to connect all overhead and underground primary taps, and all
transformers. Install at all sites being worked within the scope of the project where
they are currently missing.
- Use 397 AAC and Ampact connectors for all bare conductor feeder jumpers and 600
amp switch jumpers. Install tree wire conductor for jumpers on all poles that are
double deadended with tree wire.
- Apply grit inhibitor on all Ampact, stirrup, and dead-end connections.
- Connect primary taps and transformers to same phase as existing unless otherwise
shown on the drawing.
- All neutral connections to be made with solid compression connectors. Connect all
pole grounds to common neutral.
- Use Load-interrupter cutouts (with arc shields) on all primary overhead and
underground taps with fused protection above 40T.
- Install Wildlife Protectors on all transformers.
UNDERGROUND CONSTRUCTION
Excavation
-Trenching outside of the Right-of-way shall be of sufficient depth to provide a
minimum of 36” of cover for primary conductors and 24” of cover for secondary
conductors.
-Road crossings and all trenches within the Right-of-way shall be of sufficient depth
to provide a minimum of 36” of cover for all conductors or as required by the
permitting Agency.
-All conductors/conduits shall have a minimum of 3” of bed and 3” of clean sand
cover.
-No rocks larger than 6” shall be included in backfill.
-Backfill in road crossings and within the Right-of-way shall be compacted to 95%
density or as required by the permitting Agency.
-Restore all excavated areas to original condition.
- If four or more six inch conduits are installed in a trench, fluidized thermal backfill
(FTB) shall be installed around the conduits to a depth of six inches above and to
the sides of the conduit, and two inches underneath, per PSE Standard 6790.0140.
Vaults & Handholes
- Refer to PSE standard 6775.0040 “Vault and Handhole Installation”
- Vaults shall be placed level and 2” above final grade in landscaped areas and flush
with final grade when placed in hard surface areas.
- A minimum 6” bed of 5/8” crushed rock shall be placed under all vaults.
- All conduit entrances shall be grouted.
Conductors & Conduit
- Refer to PSE standard 6800.6000 “PVC Conduit Installation”.
- Unless splices are called for, or otherwise noted or approved, conduit risers shall be
plumbed directly to road crossing conduits.
- Install insulating caps on all unused primary bushings.
- All “spare” conduits shall be capped at each end.
Owner / Developer Contact Info
officeATTN:
Ty Tadano
Ty.Tadano@murraysmith.us
600 University St Suite 300 Seattle,WA,98101
206-462-7038 206-462-7030PHONE
CABLE TV
11536971 101132018
N/A
N/A 108123200
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
UG Expense
Removal
594137276
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:HONG NGUYEN
425-449-6609
Hong.Nguyen@pse.com
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Hong Nguyen 425-449-6609 9/5/20
Khader Gouesse 253-254-2896 9/5/20
N/A N/A N/A
Keang Lim 253-395-6916 9/5/20
N/A CITY OF RENTON
RENTON DUIP
UG RELOCATION
401 SHATTUCK AVE S RENTON WA 98057
N/A N/A
N/A 101132018
AS NOTED 1/7
King N/A N/A CSPSKEPI
N/A N/A N/A
N/A 2305E076-040-0282305E065-078-066 SEE TEXT
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
LEGEND
CONDUIT RISER
OVERHEAD TRANSFORMER
JUNCTION VAULT/JUNCTION BOX
NEW CONDUCTOR AND OR TRENCH LINE
DISCONNECT - FUSED
PULL VAULT OR SPLICE VAULT
EXISTING POLE
DOWN GUY
DISCONNECT - UNFUSED
NEW POLE
PADMOUNT TRANSFORMER
SECONDARY HANDHOLE
EXISTING CONDUCTOR TO BE REMOVED
OR ABANDONED
STREET LIGHT
TOTAL UNDERGROUND TRANSFORMER
ENERGY CUSTOMER DEMAND POINT
OR
OR
OR
OVERHEAD JUMPER CONNECTION
JOB SITE
CIRCUIT NO:
PCR-13
EAR-17
GRA-15
MFP21000326
This permit is for Major construction work in the ROW and will be billed at an additional
$60/HR for inspections. After hours and weekend work will be billed at $125/HR
Pre-Construction Meeting required
101132018SCALE: NONE
OVERHEAD CIRCUIT MAP (2305E076)
UNIVERSAL CIRCUIT MAP (2305E072)
SCALE: NONE
JOB SITE
JOB SITE
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Hong Nguyen 425-449-6609 9/5/20
Khader Gouesse 253-254-2896 9/5/20
N/A N/A N/A
Keang Lim 253-395-6916 9/5/20
N/A CITY OF RENTON
RENTON DUIP
UG RELOCATION
401 SHATTUCK AVE S RENTON WA 98057
N/A N/A
N/A 101132018
AS NOTED 2/7
King N/A N/A CSPSKEPI
N/A N/A N/A
N/A 2305E076-040-0282305E065-078-066 SEE TEXT
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
CIRCUIT NO:
PCR-13
EAR-17
GRA-15
MFP21000326
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••F4+00F5+00F6+00F7+00F8+00C13+0018" PP SD18" PP SD18" PP SD18" PP SD24" PP SD12"PP SD
12"PP SD
317808
165906
75kVA 120/240v
100kVA 120/240v
317808
165905
1/0
16637-A
16636-B
16635-C
1/0
ADM343-A
ADM344-B
ADM345-C
1/0
ADM300-A
ADM301-B
ADM302-C SHATTUCK AVE S"212"
317833
165906
317835
165906
100kVA
120/240v
V02
EXIST
PV1
EXIST
EX UG FEEDERAND UG 1/0J01
EXIST
MATCHLINE - STA F8+00
PAGE 3
1/0
ADF565-A
ADF566-B
750
ADM259-A
ADM260-B
ADM261-C
EAR-17ADM259-A
ADM260-BPCR-13PCR-13PCR-13
V01EXIST
IP01
IP02
NO
S 3RD ST ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••F8+00F9+00F10+00F11+0024" PP SD24" PP SD24" PP SD24" PP SD12"PP SD
12"PP SD
12"DI
S
D 12"DI SD12"PP S
D
317793
165921
SHATTUCK AVE SP01
EXIST
X1034
EX UG FEEDER
S 3RD PL
"336"
"220"
"440"
317783
165911
1/0
ADM300-A
ADM301-B
ADM302-C
1/0
ADM303-A
ADM304-B
ADM305-C317783
165887
50kVA
120/240v
1/0
16084-A
16085-B
16086-C
317779
165898
NEW UG 1/0
EX UG 1/0
J03
EXIST
V03
EXIST
MATCHLINE - STA F8+00
PAGE 3
PCR-13 PCR-13
EAR-17EAR-17750
ADM259-A
ADM260-B
ADM261-C
PCR-13PCR-13
EAR-17
EAR-17EAR-17
1/0
16081-A
16082-B
16083-C
1/0
ADM319-A
ADM320-B
ADM321-CEAR-17J02
EXIST
IP03
ALLEYWAY
MATCHLINE - STA F11+40
PAGE 4
IP04
IP05
IP06
IP07
SITE PLAN 101132018SCALE: 1" = 20'
Vault & Equipment Table
Site Grid
Number
Vault Size
& Cover
Type & Size
Equipment
In Vault
Primary Bushings Transformer
ID Numbers
(Company ID)
ASBUILT INFORMATION
Foreman-Complete (Include Transformer Phase
Tapped and Test Secondary Voltage)LB DC
J01 317833
165906 EXISTING -3 -
V01 317835
165906 EXISTING TUT
100kVA 120/240v --
PV1 317808
165905 EXISTING ---
V02 317808
165906 EXISTING
TUT
75kVA 120/240v
100kVA 120/240v
6 -
J02 317783
165911 EXISTING -9 -
V03 317783
165887 EXISTING TUT
50kVA 120/240v 3 -
CABLE REMOVAL SCHEDULE
CABLE
NO.
LOCATIONS CABLE
(LF) EST CABLE TYPE YEAR INST
FROM TO
AØ16637-BØ16636-CØ16635 J01 V02 285
1/0 AL JKT
AØADM300-BØADM301-CØADM302 V02 J02 265
AØADM303-BØADM304-CØADM305 J02 V03 160
AØADM319-BØADM320-CØADM321 J02 J04 385
Total Feet 1090 (1/0 AL JKT) ACTUAL________Removed
29 LF 12" PP SD
@ SLP=1.00%
48'' SDMH #34CB #44 STA F9+24, 14' RT
CB #44 TO SDMH #34
SCALE: 1"=20' HORIZ, 1"=5' VERT
38 LF 12" DI SD
@ SLP=0.50%
CB #46
48'' SDMH #34
STA F9+24, 14' RT 42 LF 12" PP SD
@ SLP=0.50%
48'' SDMH #52
CB #46 TO SDMH #52 TO SDMH #34
SCALE: 1"=20' HORIZ, 1"=5' VERTEXIST TELEXIST 12"SD (ABAN)EXIST 2"GEXIST UGPJ02-V03 CONDUIT PROFILE
EXIST 16"WEXIST 10"SSEXIST UGPEXIST TEL (2)EXIST 12"WEXIST TELEXIST UGPEXIST 12"SD (ABAN)UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Hong Nguyen 425-449-6609 9/5/20
Khader Gouesse 253-254-2896 9/5/20
N/A N/A N/A
Keang Lim 253-395-6916 9/5/20
N/A CITY OF RENTON
RENTON DUIP
UG RELOCATION
401 SHATTUCK AVE S RENTON WA 98057
N/A N/A
N/A 101132018
AS NOTED 3/7
King N/A N/A CSPSKEPI
N/A N/A N/A
N/A 2305E076-040-0282305E065-078-066 SEE TEXT
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
CIRCUIT NO:
PCR-13
EAR-17
GRA-15
SITE NOTES
IP01
INTERCEPT AND EXTEND EXISTING 2-4" CONDUIT SOUTH TO IP02
IP02
INTERCEPT AND EXTEND EXISTING 2-4" CONDUIT SOUTH TO V02
IP03
INTERCEPT AND EXTEND EXISTING 2-4" CONDUIT SOUTH TO J02
IP04
INTERCEPT AND EXTEND EXISTING 3-4" CONDUIT SOUTH TO IP05
IP05
INTERCEPT AND EXTEND EXISTING 3-4" CONDUIT SOUTH TO IP06
IP06
INTERCEPT AND EXTEND EXISTING 3-4" CONDUIT SOUTH TO IP07
IP07
INTERCEPT AND EXTEND EXISTING 3-4" CONDUIT SOUTH TO J04
MFP21000326
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••F12+00F13+00F14+00F15+0036" PP SD24" PP SD36" PP SD24"PP SD12"PP SD
12"DI SD36"PP SD12"PP SD
8"PP SD
S 4TH ST
"400"
1/0
58471-A
58472-B
58473-C
1/0
ADM319-A
ADM320-B
ADM321-C 317758
165922
500kVA
120/208v
317757
165921
1/0
ADM317-B
ADM318-C
SHATTUCK AVE S317727
165903
1/0
164084-A
164085-B
164086-C
1/0
ADM309-A
ADM310-B
ADM311-C
"416"
"418"
"408"
V04
EXIST
J04
EXIST
EAR-17
EAR-17HH1 HH1A
37.5kVA
120/240v
317729
165909
317730
165908
V05
EXIST
PV2
EXIST
MATCHLINE - STA F15+40
PAGE 4
MATCHLINE - STA F11+40
PAGE 4
IP08
1/0
ADM316-A
1/0
ADM317-B
ADM318-C
1/0
ADM315-A ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••F16+00F16+8036" PP SD36" PP SD36" PP SDS 4TH PL
317703
165903
317703
165912
300kVA
120/208v
1/0
ADM312-A
ADM313-B
ADM314-C
J05
EXIST
V06
EXIST
MATCHLINE - STA F15+40
PAGE 4
SITE PLAN 101132018SCALE: 1" = 20'
Vault & Equipment Table
Site Grid
Number
Vault Size
& Cover
Type & Size
Equipment
In Vault
Primary Bushings Transformer
ID Numbers
(Company ID)
ASBUILT INFORMATION
Foreman-Complete (Include Transformer Phase
Tapped and Test Secondary Voltage)LB DC
J04 317757
165921 EXISTING 6 -
PV2 317730
165908 EXISTING --
V05 317729
165909 EXISTING TUT
37.5kVA 120/240v 1 -
J05 317703
165903 EXISTING 2 -
CABLE REMOVAL SCHEDULE
CABLE
NO.
LOCATIONS CABLE
(LF) EST CABLE TYPE YEAR INST
FROM TO
AØADM316 J04 V05 362 1/0 AL JKT
BØADM317-CØADM318 J04 J05 662 1/0 AL JKT
Total Feet 1045 (1/0 AL JKT) ACTUAL________Removed
SECONDARY HH/PEDESTAL TABLE
Site Pedestal
or
Handhole
Number of
Positions
Required
Remarks
HH1A Handhole 4
J04-IP08 CONDUIT PROFILE
44 LF 12" PP SD
@ SLP=0.50%
54'' SDMH #38
STA F12+04, 17' RT
CB #51
CB #51 TO SDMH #37
SCALE: 1"=20' HORIZ, 1"=5' VERT
48'' SDMH #37EXIST 12"GEXIST 10"SSEXIST TELEXIST 16"WEXIST UGPEXIST TELUTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Hong Nguyen 425-449-6609 9/5/20
Khader Gouesse 253-254-2896 9/5/20
N/A N/A N/A
Keang Lim 253-395-6916 9/5/20
N/A CITY OF RENTON
RENTON DUIP
UG RELOCATION
401 SHATTUCK AVE S RENTON WA 98057
N/A N/A
N/A 101132018
AS NOTED 4/7
King N/A N/A CSPSKEPI
N/A N/A N/A
N/A 2305E076-040-0282305E065-078-066 SEE TEXT
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
CIRCUIT NO:
PCR-13
EAR-17
GRA-15
SINGLE PHASE SECONDARY CONCRETE HANDHOLE
Not to scale 6050.2020-1
TOP VIEW
SIDE VIEW
2'-4"
EXCAVATION: 5-1/3 CUBIC YARDS
7'-0"
6'-0"
2"
2'-6"
Install PVC bell endsand grout into wall
2'-6"
Handhole
820 lbs
Conduits and conductors shall enter fromends of handhole through knockouts provided
Typical customer runservice conductors in duct
Steel Door
Seal conduitwith foam
Customer-installed grounding wires ( the "4th" wire on the single-phase systems and the "5th" wire on
the three-phase systems) shall not be connected to PSE's ground or neutral bus. They shall be
removed by customer or cut off at the vault wall.
6" Crushed rock
SITE NOTES
IP08
INTERCEPT AND EXTEND EXISTING 2-4" CONDUIT NORTH TO J04
INTERCEPT AND EXTEND EXISTING 1-3" CONDUIT NORTH TO HH1A
MFP21000326
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••F5+00F6+00F7+00G6+00G4+00G5+00G6+00C13+00 C14+00 C15+00 C16+00 C17+0018" PP SD18" PP SD 18" PP SD
18" PP SD
18" PP SD18" PP SD24" PP SD12" PP SD18" PP SD12" PP SD12"PP SD 12"DI SD12
"
D
I
S
D
12"DI SD12"DI SD
12"DI SD
317808
165906
75kVA 120/240v
100kVA 120/240v
317808
165905
1/0
16637-A
16636-B
16635-C
1/0
ADM343-A
ADM344-B
ADM345-C
317807
165925 2x25kVA
120/240v
317807
165925
1/0
ACT323-A
ACT324-B
S 3RD STSHATTUCK AVE S"305"
"309"
"212"
"300"WHITWORTH AVE S25kVA
120/240v
317805
165937
1/0
AFD575-A
1/0
ADM346-A
ADM347-B
ADM348-C
1/0
16615-A
16616-B
16617-C
1/0
ADM353-A
ADM354-B
ADM355-C
"319"
"401"
2x25kVA 120/240v
25kVA 120/208v
317824
165939
75kVA
120/240v
317825
165939
V02
EXIST
PV1
EXIST
EX UG FEEDEREX UG 1/0
J06
EXIST
V07
EXIST
V08
EXIST
V10
EXIST
V09
EXIST
1/0
ADF565-A
ADF566-B
750
ADM259-A
ADM260-B
ADM261-C
EX UG 1/0PCR-13PCR-13 GRA-15NOPCR-13
OPEN-WYE/OPEN DELTA
Δ/Y
GRA-15
GRA-15GRAD-15IP01
IP02
IP09
NO
S 3RD ST
MATCHLINE - STA C17+80PAGE 5••••••••••••••••••••••••••••••••••••••••••••••••••••••H5+00H6+00C18+00 C19+00 C20+00
18" PP SD
12" PP SD
12" C900 SD18" PP SD 12" PP SD12"DI SD
12"DI SD
25kVA
120/240v
317804
165965
"505"
S 3RD ST MORRIS AVE SV11
EXIST
GRA-15 GRA-15MATCHLINE - STA C17+80PAGE 5SITE PLAN 101132018SCALE: 1" = 20'
Vault & Equipment Table
Site Grid
Number
Vault Size
& Cover
Type & Size
Equipment
In Vault
Primary Bushings Transformer
ID Numbers
(Company ID)
ASBUILT INFORMATION
Foreman-Complete (Include Transformer Phase
Tapped and Test Secondary Voltage)LB DC
V08 317805
165937 COMBO VAULT TUT
25kVA 120/240v 6 -
V09 317824
165939 EXISTING
TUT
2X25kVA 120/240v
1X25kVA 120/208v
3 -
V11 317804
165965 EXISTING TUT
25kVA 120/240v 3 -
V08-V11 CONDUIT PROFILE
CB #27
48'' SDMH #23
STA C18+53, 16' LT
5 LF 12" PP SD
@ SLP=0.37%CB #28
37 LF 12" DI SD
@ SLP=0.52%
CB #27 TO CB #28 TO SDMH #23
SCALE: 1"=20' HORIZ, 1"=5' VERT
CB #24
45 LF 12" DI SD
@ SLP=0.51%
48'' SDMH #21
STA C16+03, 19' LT
SDMH #21 TO CB #24
SCALE: 1"=20' HORIZ, 1"=5' VERT
CB #25
39 LF 12" DI SD
@ SLP=0.49%
48'' SDMH #22
STA C17+23, 18' LT
CB #26
CB #26 TO CB #25 TO SDMH #22
SCALE: 1"=20' HORIZ, 1"=5' VERTEXIST 12"WEXIST UGPPROP SSEXIST 4"GEXIST 12"WPROP SSEXIST 4"GEXIST 12"WEXIST UGPPROP 24"SSEXIST 4"GCB #24
45 LF 12" DI SD
@ SLP=0.51%
48'' SDMH #21
STA C16+03, 19' LT
SDMH #21 TO CB #24
SCALE: 1"=20' HORIZ, 1"=5' VERTEXIST 12"WEXIST UGPPROP 24"SSEXIST 4"GV08-IP09 CONDUIT PROFILE
30 LF 12" DI SD
@ SLP=0.51%
CB #22
48'' SDMH #20
STA G5+19, 10' LT
5 LF 12" PP SD
@ SLP=5.00%
CB #23
CB #22 TO CB #23 TO SDMH #20
SCALE: 1"=20' HORIZ, 1"=5' VERTEXIST 2"GEXIST W (ABAN)EXIST 12"WPROP 8" SS &EXIST 8" SS CABLE REMOVAL SCHEDULE
CABLE
NO.
LOCATIONS CABLE
(LF) EST CABLE TYPE YEAR INST
FROM TO
AØ16615-BØ16616-CØ16617 V08 V09 220 1/0 AL JKT
AØADM353-BØADM354-CØADM355 V08 V11 345 1/0 AL JKT
Total Feet 565 (1/0 AL JKT) ACTUAL________Removed
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Hong Nguyen 425-449-6609 9/5/20
Khader Gouesse 253-254-2896 9/5/20
N/A N/A N/A
Keang Lim 253-395-6916 9/5/20
N/A CITY OF RENTON
RENTON DUIP
UG RELOCATION
401 SHATTUCK AVE S RENTON WA 98057
N/A N/A
N/A 101132018
AS NOTED 5/7
King N/A N/A CSPSKEPI
N/A N/A N/A
N/A 2305E076-040-0282305E065-078-066 SEE TEXT
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
CIRCUIT NO:
PCR-13
EAR-17
GRA-15
MFP21000326
"300"
J01
EXIST
V01
EXIST
V02
EXIST
PV01
EXIST NO
J02
EXIST
V03
EXIST
J05
EXIST
V06
EXIST
PV02
EXIST
V05
EXISTSHATTUCK AVE SS 3RD ST WHITWORTH AVE SS 3RD ST MORRIS AVE SV08
EXIST
V09
EXIST
V10
EXIST
P01
EXIST
NO
SHATTUCK AVE SALLEY WAY
S 3RD PL
J04
EXIST
V04
EXIST
S 4TH ST
S 4TH PL
HH1A
NEW 2-4"
IP01
IP02
IP03 NEW 2-4"
NEW 1-4"
IP08
NEW 1-4"
NEW 1-4"
NEW 1-3"
NEW 1-4"
IP04
IP05
NEW 1-4"
IP06
IP07
IP09
NEW 2-4"
V11
EXIST
J03
EXIST
101132018CONDUIT DIAGRAM
SCALE: NOT TO SCALE
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Hong Nguyen 425-449-6609 9/5/20
Khader Gouesse 253-254-2896 9/5/20
N/A N/A N/A
Keang Lim 253-395-6916 9/5/20
N/A CITY OF RENTON
RENTON DUIP
UG RELOCATION
401 SHATTUCK AVE S RENTON WA 98057
N/A N/A
N/A 101132018
AS NOTED 6/7
King N/A N/A CSPSKEPI
N/A N/A N/A
N/A 2305E076-040-0282305E065-078-066 SEE TEXT
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
CIRCUIT NO:
PCR-13
EAR-17
GRA-15
Primary Cable & Conduit Table (Foreman to Complete)
LOCATION CONDUIT PRIMARY CABLE
AS BUILT INFORMATION
From To Size
(in)
Qty
Design
Length
(ft)
Actual
Length
(ft)
TYPE BENDS PULL
(lbs)
PULL
Rev
(lbs)
Cable
Size
Design
Length
(ft)
Actual
Length
(ft)
CABLE NUMBERS MANUFACTURING INFORMATION
DB120 HDPE SCH 80 90°45°22°11°A B C Manufacturer Compound Year Actual Amount Installed
(Conduit & Cable)
IP01 IP02 4 2 31 X 2 CONDUIT ONLY
J01 V02 CABLE ONLY 1/0 JKT 285 EIT750 EIT751 EIT752
IP03 J02 4 2 11 X 2 CONDUIT ONLY
V02 J02 1/0 JKT 265 EIT753 EIT754 EIT755
J02 V03 4 1 140 X 1/0 JKT 160 EIT756 EIT757 EIT758
IP04 IP05 4 1 32 X 2 CONDUIT ONLY
IP06 IP07 4 1 32 X 2 CONDUIT ONLY
J02 J04 CABLE ONLY 1/0 JKT 385 EIT759 EIT760 EIT761
J04 IP08
4 1 155 X 1 CONDUIT ONLY
4 1 155 X 1 CONDUIT ONLY
J04 V05 CABLE ONLY 1/0 JKT 362 EIT762
J04 J05 CABLE ONLY 1/0 JKT 662 EIT763 EIT764
V08 IP09 4 2 84 X 1 CONDUIT ONLY
V08 V09 CABLE ONLY 1/0 JKT 220 EIT765 EIT766 EIT767
V08 V11 4 2 335 X 1 1 1/0 JKT 355 EIT768 EIT769 EIT770
TOTAL 4 943 -X 6 14 -1/0 JKT 2694 -
MFP21000326
"300"
J01
EXIST
V01
EXIST
V02
EXIST
PV01
EXIST
NO
J02
EXISTV03
EXIST
J05
EXIST
V06
EXIST
PV02
EXIST
V05
EXISTSHATTUCK AVE SS 3RD ST WHITWORTH AVE SMORRIS AVE SV08
EXIST
V09
EXIST
V10
EXIST
P01
EXIST
NO
SHATTUCK AVE SALLEY WAY
S 3RD PL
J04 EXIST
V04
EXIST
S 4TH ST
S 4TH PL
HH1A
EXIST 1/0
ACT323-A
ACT234-B
NEW 1/0
EIT756-A
EIT757-B
EIT758-C
NEW 1/0
EIT763-B
EIT764-C
NEWUG 350 TPLX
NEW 1/0
EIT750-A
EIT751-B
EIT752-C
NEW 1/0
EIT753-A
EIT754-B
EIT755-C
EXIST1/0
ADM286-A
ADM287-B
ADM288-C
EXIST1/0
ABR953-A
ABR952-B
ABR951-C
EXST1/0
ADM292-A
EXIST1/0
AED206-B
NEW 1/0
EIT759-A
EIT760-B
EIT761-C
NEW 1/0
EIT762-A
EXIST1/0
58471-A
58472-B
58473-C
1/0
ADM323-A
ADM324-B
ADM325-C
EXIST1/0
AED207-A
NEW 1/0
EIT765-A
EIT766-B
EIT767-C
NEW 1/0
EIT768-A
EIT769-B
EIT770-C
EXIST 1/0
ADM343-A
ADM344-B
ADM345-C
EXIST 1/0
ADM346-A
ADM347-B
ADM348-C
EXIST 1/0
EHH400-A
EHH401-B
EHH402-C
EXIST 1/0
AFD575-A
EXIST 1/0
16605-A
16606-B
16607-C
EXIST 1/0
16606-B
EXIST 1/0
ADL889-A
ADL890-B
ADL891-C
EXIST 1/0
ADM352-A
V11
EXIST
J03
EXIST
EXIST1/0
16081-A
16082-B
16083-C
EXIST 1/0
ADM15-A
PCR-13PCR-13GRA-15GRA-15 GRA-15EAR-17PCR-13EAR-17
EAR-17EAR-17EAR-17EAR-17EAR-17101132018CABLE DIAGRAM
SCALE: NOT TO SCALE
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Hong Nguyen 425-449-6609 9/5/20
Khader Gouesse 253-254-2896 9/5/20
N/A N/A N/A
Keang Lim 253-395-6916 9/5/20
N/A CITY OF RENTON
RENTON DUIP
UG RELOCATION
401 SHATTUCK AVE S RENTON WA 98057
N/A N/A
N/A 101132018
AS NOTED 7/7
King N/A N/A CSPSKEPI
N/A N/A N/A
N/A 2305E076-040-0282305E065-078-066 SEE TEXT
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
CIRCUIT NO:
PCR-13
EAR-17
GRA-15
MFP21000326