Loading...
HomeMy WebLinkAboutR-420222O I I W O� LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE LICENSED ENGINEER OR LANDSCAPE ARCHITECT. J EXIST. IRRIGATION VALVE RELOCATE EXISTING ROTOR SPRAY HEAD TO EDGE OF PROPOSED NEW PLANTING AREA AND ADJUST SPRAY LIMITS TO ACCOMMODATE NEW PLANTING AREA - !� REMOVE EXISTING ROTOR SPRAY HEADS AND CONNECTING LATERALS FROM NEW PLANTING AREA IRRIGATION SCHEDULE ���.�� �. � ..�.�+ ��� +� �•... � ...�� r+�. �'�'� r , + �� .ram ,� rr �. +mow � �.--� � � . �+ -+ • �T" �— NEW BATTERY OPERATED IRRIGATION REMOTE CONTROL VALVE - CONNECT TO EXISTING 4 INCH MAINLINE EXIST. CONIFER - HAND DIG IRRIGATION WITHIN 15' OF TREE IAInDT1-1 IDDIIrOTIif1Al DI DM 20 0 20 40 scale feet SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI DETAIL O O S 0 • RAIN BIRD 1806-SAM-PRS 15 SERIES MPR 20 30 Q T H TO F SHRUB SPRAY 6.0" POP-UP SPRINKLER WITH CO -MOLDED WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH SEAL-A-MATIC CHECK VALVE, AND PRESSURE REGULATING DEVICE. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY DETAIL RAIN BIRD PGA GLOBE 1 111, 1-1/211, 2" ELECTRIC REMOTE CONTROL VALVE, GLOBE. IRRIGATION LATERAL LINE: PVC SCHEDULE 40 357.4 L.F. 1 I 22 - • 20- 4..r��9 A -f LAKE WASHINGTON NORTH IRRIGATION NOTES: 1. IRRIGATION AND MAINTENANCE SHALL CONFORM TO THE 5. THE EXISTING IRRIGATION CONTROLLER IS LOCATED SOUTH OF IMPLEMENTATION GUIDE FOR RESTORATION AND PERMITTING THE BRIDGE IN THE COMFORT STATION MAINTENANCE ROOM. FOR LAKE WASHINGTON AND LAKE SAMMAMISH, JULY 25, 2019. 2. EXISTING IRRIGATION SHOWN WAS REFERENCED FROM AS -BUILT DRAWINGS THAT ARE OLD. CONTRACTOR SHALL NOTE THAT THE EXISTING IRRIGATION SHOWN MAY NOT REPRESENT ACTUAL CONDITIONS ON SITE. CONTRACTOR WILL NEED TO VERIFY THE LOCATION OF EXISTING EQUIPMENT IN THE FIELD PRIOR WITH PARKS MAINTENANCE PERSONNEL PRIOR TO MAKING THE NECESSARY IRRIGATION IMPROVEMENTS. 3. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING IRRIGATION THAT IS IMPACTED BY NEW IMPROVEMENTS AND VERIFY THAT ALL IRRIGATION ZONES WORK PRIOR TO THE PROJECT BEING DEEMED COMPLETE. - - - - - - - - PIPE SLEEVE: PVC SCHEDULE 40 12.0 L.F. 4. CALL UTILITY LOCATE SERVICE 72 HOURS PRIOR TO IRRIGATION Valve Callout INSTALLATION. EXERCISE CARE TO PROTECT UNDERGROUND Valve Number UTILITIES AND AVOID DISTURBING OR DAMAGING THEM IF # �ValveNum PRESENT. Valve Size �F WASH CJ, SURVEYED: Mwoi/�9 oP ��l Vim' 7 WSP USA Inc. 33301 9th Avenue South � Z DESIGNED: DEW Suite 300 Federal Way, WA 98003-2600 o N �<" DRAWN: Si TEL: (206) 431-2300 `r6,7 �1`ti��� ti� CHECKED: DEW FAX: (206) 431-2250 `S`�O FkP. 10/° 4"44 SCAPE �6° NO. REVISION BY DATE APPR APPROVED: GDN 6. CONTRACTOR SHALL CONTACT THE CITY OF RENTON PARKS FACILITIES SUPERVISOR AND COORDINATE IRRIGATION RUN TIMES WITH THE EXISTING IRRIGATION ZONES. 7. SEE DRAWING IR-3 FOR IRRIGATION DETAILS. 8. IT IS UNCLEAR IF THE ORIGINAL IRRIGATION INSTALLATION INCLUDED SWING PIPES OR FUNNY PIPE FOR THE CONNECTION TO THE IRRIGATION HEAD. CONTRACTOR IS REQUIRED TO OBSERVE THE EQUIPMENT INSTALLATION DURING DEMOLITION AND MATCH THE EXISTING CONNECTIONS FOR CONSISTENCY. SCALE: 1 "=20' ONE INCH AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY 7 R-420222 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT IRRIGATION PLAN SCHEDULE &NOTES 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: IR-2 SHEET: 26 OF: 45 C:) C:)O O T N a J C'7 C'7 O O 0 I T CV