Loading...
HomeMy WebLinkAboutR-417910SEE SHEET C1.32 ' O i 13. L T 13f 01.25, Q26.50' L T a W 25' ' 0 I 17 I �X CEMENT CONCRETE CURB I °v ' PER C.O.R. STD PLAN 101 SEE SHEET C4.36 (TYP) 0 CEMENT CONCRETE SIDEWALK PER C. O.R. STD PLAN 102 QSEE SHEET C4.36 (TYP) I I o � O a b OFFS/TE TREE (TYP) \ v CL PROPERTY \ LINE (TYP) EX SHED (APPROX o 0CA [ION) 26'f EX GARAGE (APPROX 10 CA TION) \ ' 92f 02.51, 16.00' L T I 91*90.31, 14.22' LT � I _ \ 98+00 92f 00 W Qo I - W� W 1 \ 10 \ 9 I 2, 938E SF \ \ 2, 884E SF — n 2,5611 SF SEE ALLEY 1 SECTION, SHEET C3.31 I� 13 2,5611 SF 14 II2, 686E SF I II II TR. if �+ 2, 956E SF \ \ I I a F 'a. V \ °' V v 6 .q I •ate, V.'. •.4• vA ❑ 3,175 fSF 2,629E SF \ \ 34 29 35, 0 35' 26' 12*44.80, 13.00' RT 34 _ ALLEY-1 aQ 12+35.23, 10.70 RT 33 0 12f20.47, 7.00' RT : a 12f 04.81, ROAD A = •. O — - 30f00.00, ALLEY 1 . 1 4 35 a < 35' 51' — I 12f 04.68, 7.00' RT 2$' 00 � � I DRIVEW,4 Y PER C.O.R. 31+-- / 3 I 4 STD. DTL. 104.3, \ \ 2, 668E SF 2,275E SF 5 TYPE RIB (TYP) 2 2, 275E7 T SF 6 2, 716E SF \ I 3, 203E SF � I ►I 2,429E SF \ I \ 11f89.43, 7.00' RT \ 6, / 11 f 78.71, 10.08' RT INSTALL 2 MAX/FORCE'S COLLAPSIBLE STANDARD STYLE SEE VAUL T ACCESS 6''' 11 f 68.44, 13.00' R ROAD SECTION, 'd PROPOSED 10' WRENCH OPERATED BOLLARDS I UTILITY ESMT (TYP) (MODEL 1MCSW-SS3-EZ) AL SHEET C4.35 — I PROPOSED BSBL (TYP) , ° ° \ . v 4 35 , 35 v 36' �/ a 6i , •\ , TR. J , 5 ° a ° , .50 2,246 fsF VAUL T ACCESS RD R,2p, lb 12 71+00— �� 11 f 43. �-7,13. 00 RT 71 * 98. 49, 0.00 / 11 f33. 64,-,10. 04 T ° �Di — - 6�' END ROAD / EX TREE ' ° / �C� 2 �► TO BE SAI/ED (TYP) o . , / 70f88.50, VAULT ACCESS ROAD = PROPOSED 80+00.00, VAULT ACCESS A I STREET LIGHT ao, ° : wort / / 44' �,25 , (TYP) PROPOSED h 11 f24. 64, ° � 1$ 11 * 07.37, 7. 00' RT N TRA CT D (A CCESS) (STORMRj OPEN SPACE) ' 7. 06' RT 11 f 0k 3, ROAD A = 10, 395 fSF / / 2 g14" 10 UTILITY ESMT � 4, 754 fSF (T) ��, a ' 11+09.03, 121+45. 2, NC%4TH VAUL T ACCES ROAD 1300 L T 11 f 07 4'OAD A = -4 SEE VAUL T ACCESS 7 ;,AUL T ACCESS ROA 20' ROAD A SECTION, SECT/ON, SHEET CAJ5 TR91 CT A SHEET C3. 31 �\ � a Xo 10f 95. 33, 20' a (STORM/iPEN SPACE) 7. 00' RT 2 FIXED BOLLARS AND • �`' a /P 8Of51.34, 0.00' b 15,.389 fSF 2 REMOVABLE WOODEN BOLLARDS —10f87.13, 9.49 RT END ROAD a (LOCATED IN THE MIDDLE) - 10f75.91, 1300' RT PER C.O.R. STD SOTL H021 SHEET C342 - 10f69.29, 13.00' RT 8' v, 15 3, 604E SF I s , A. o -- d -- --r - --33f41.73, 0.00' END ROAD � II 16 4, 062E SF 15' STRUCTURE SETBACK FROM SENSITIVE AREA. SEE WETLAND MITIGATION PLAN. PROPERTY LINE (TYP) ► 5' W/DE CONCRETE WALKWAY PER SECTION SHOWN ON SHEET I I C3 31 (TYP) 15, o SETBACK I I 15' STRUCTURE SETBACK FROM SENSI77Vf- AREA. I SEE WETLAND MITIGATION PLAN. STAIRS SHALL BE CONSTRUCTED PER THE J CURRENT INTERNATIONAL BUILDING CODE. / SEPARATE BUILDING PERMIT REQUIRED. n / O / 0 TRACT 6 '�• l •' (NGPA) ' \ 25,517 fSF •'\ 1000, IF" '\ '� _.._.._.. ROW .._.._ DEDICATION _ 72' •—10158.07, 9.49' RT k�,-10f49.87, 7.00' RT — 12 \ a ��10145.12, 7.00' RT ° 0 96+v NORTH VAULTACCESS ROAD I—6`5'36" N 31<Q SEE NORTH VAUL T ACCESS °.=1.59 �� �_ 22 / 'a o ROAD SECT/ON, SHEET C4.35 7 10 8' `. PROPOSED STREETa I 121 ' LIGHT (TYP) v h 'I" 00 SEE LINCOLN A Vf NE SHEET C3.31 `(EYMAP L/NCOLN AtlE NE 10f 00.62, ROAD A = / 99f00 100*00.00, LINCOLN AVE NEo 100+00 _ LEGEND � — RIGHT OF WA Y LINE PROPERTY LINE ---------- SETBACK LINE LOT LINE OBOBOBO ROCKERY RETAINING WALL REDI-ROCK RETAINING WALL O 0 EX TREES TO BE SA VED 96f00 90f00 — �— —�x N LINCOLNA VE NE — w 1 1 CONSTRUCTION RECORD DRAWINGS CS •► SCALE: 1" = 20' 0 10 20 40 m 91f00 Q W WV I rW M E M 2/ 13/24 H H H SURVEYED: SCALE: LENN R. SPRAGUE P.L.S. DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOOR�pE ONE INCH CHECKEDHOLL/ HEA VRIN IFAT FULL S NOT ONEC NCH BY DATE APPR APPROVED: SCALE ACCORDINGLY ROLL/ H. HEA VR/N P. E. ROW DED/CA T/ON 4,296 fSF 194' PROPERTY LINE (TYP) ASBU/LT NOTE � THE ASBUIL T INFORMA 17ON DEPICTED ON THESE PLANS /S BASED UPON FIELD SURVf-Y INFORMATION PRO VDED BY CORE DESIGN AND SUPPLEMENTED BY SITE CONTRACTOR, GOODFELLOW BROTHERS, ON JANUARY 297H, 2024. GOODFELLOW BROTHERS INDICATES THAT THE DATA PROVIDED TO CORE DESIGN ACCURATEL Y REPRESENTS FIELD CONDITIONS ON THE DATE OF THEIR SURVEY. CORE DESIGN HAS REVIEWED THE INFORMATION PROVIDED FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT, AND TO THE BEST OF OUR KNOWLEDGE THE /NFORMA 17ON /S /N ACCORDANCE WITH THE OBSERVED FIELD CONDITIONS. UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. VERTICAL: NAVD 1988 CITY 0 F HORIZONTAL-NAD 1983/183/1991 %R RENTON DATUM Planning/Building/Public Works Dept. /GHT-OF_y'gY M'J I v W W TW M r\^ O v, O W� rW^X-1 Qk 2/13/24 R-417 910 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CANOPY 4196 LINCOLN AVE NE, RENTON, WA 98056 SITE PLAN O DATE: 211JI24 Q FIELDBOOK: PAGE: DRAWING NO: C1.31 SHEET: OF: 10 107 CONSTRUCT/ON RECORD DRA WINGS