Loading...
HomeMy WebLinkAboutR-4179360 O O v v ALL STORMWATER FEATURES (DETENTION FACILITIES, WATER QUALITY FACILITIES, / V A w CONVEYANCE SYSTEM, ETC) SHALL BE PUBLIC UNLESS NOTED / OTHERWISE. / / THE COMPLETE ROOF/FOOTING / DRAIN SYSTEM SHALL BE PRIVATE UP TO THE CONNECTION o a �. POINT WITH THE FIRST PUBLIC � � CATCH BASIN EX GROUND CONTOUR (TYP) o / c PROPOSED FINISH - '. GRADE CONTOUR • . / ! (TYP) 160— \ \ \ ' ,,0\ I I I I TRACT C \ �� � LA T- N47 I' (OPEN SPACE) (,'f N _ 158�LON.' W12 cc_ W£ AND "C" zM--_—_ LA T- N47315 LON: W12271. 71 / - \ 6" SDc 145 48 RIM IN 6" IE s o CB35 / 30.1LF —130 — — 38EF 6" 7 » PRI ATE ® 9.•f399 6 SOCO 119.21 RlM2 6" IE BBB- / 11 6" IE ;1499- 120 I � I `(EYMAP L/NCOLN ,qVE NE LEGEND PROPERTY LINE 100 PROPOSED CONTOUR EXISTING CONTOUR STORM MAIN STORM SERVICE EXISTING STORM MAIN ❑❑ STORM CB TYPE l 0 STORM CB TYPE ll PIPE MA TER/AL ALL PIPES EXCEPT THOSE SPECIFIED AS DI SHALL BE POL YPROPYZENE STORM SEWER PIPE PER WSDOT SECTION 9-05.24 NOTE ALL CLEANOUTS LOCATED WITHIN A DRIVABLE SURFACE SHALL SE REQUIRED TO HA VE TRAFFIC BEARING LIDS. \ 1 1 CONSTRUCTION RECORD DRAWINGS NO. REVISION SEE SHEET C4.10 4 0 PERF PVC WALL DRAIN (TYP) I ASBU/L T NOTE I THE ASBUIL T INFORMATION DEPICTED ON THESE PLANS IS BASED UPON FIELD SURVEY INFORMATION PROVIDED BY CORE DESIGN AND SUPPLEMENTED BY S/TE CONTRACTOR, GOOOFELLOW BROTHERS, ON IANUARY 29TH, 2024. GOODFELLOW BROTHERS INDICATES THAT THE DATA PROVIDED TO CORE DESIGN ACCURA7FL Y REPRESENTS FIELD CONDITIONS ON THE DATE OF THEIR SURVEY. CORE DESIGN HAS REV/E11ED THE INFORMATION PROVIDED FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT, AND TO THE BEST OF OUR KNOWLEDGE THE INFORMATION /S IN ACCORDANCE WITH THE OBSERVED FIELD CONDITIONS. MEM 2/13/24 HHH SURVEYED: R SPRAGUE P.L.5 SCALE. DESIGNED: HOLLI HEA VRIN DRAWN: MARY MOORS ONE INCH CHECKED: AT FULL SCALE HOLLI HEA VRIN IF NOT ONE INCH BY DATE APPR APPROVED: SCALE ACCORDINGLY HOLLI H. HEAVRIN P.E. •� . WETLAND/D" 15' STRUCTURE SETBACK FROM SENSITIVE AREA. SEE WETLAND MITIGATION PLAN. SCALE: 1" = 20' 0 10 20 40 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 VERTICAL. NAVE) 1988 HORIZONTAL- HAD 1983/1991 DATUM + �� + • RENTON 'PFNiOv I I I o °0 I I19 0o J o N LAT N4731'44.2406" LON.• W12271:31.3563" TRACT ,F �pK INS h, o wAsyfF CIVIL ENGINEERING o• z LANDSCAPE ARCHITECTURE Z' PLANNING 99 DESIGN SURVEYING ISTER '��v n1NAL 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 2/13/24 R-417936 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CANOPY 4196 L/NCOLNAVENE, RENTON, WA 98056 PAGE: 2113124 Planning/Building/Public Works Dept. C4.11 STORM DRAINA GE SERVICE PLAN SHE: 36 OF: 107 CO/VSTRVCT/ON RECORD DRA WINGS