Loading...
HomeMy WebLinkAboutR-404861Uj W l— I— LLI 0 U_ CD Q NOTES 1. KEEP ROOTBALL MOIST AND PROTECTED AT ALL TIMES, 2. HOLD CROWN OF ROOTBALL AT OR JUST ABOVE FINISH GRADE. 3. PROTECT TRUNK AND LIMBS FROM INJURY. 4, BACKFILL TO BE SETTLED USING WATER ONLY - NC MECHANICAL COMPACTION. 5- REMOVE ALL WRAP, TIES & CONTAINERS, REGARDLESS OF MATERIAL - PRUNE DAMAGED TWIGS AFTER PLANTING PLACE IN VERT. POSITION: DOUBLE LEADERS WILL BE REJECTED (2) LODGEPOLE STAKES, PLUMB WITH ELASTIC CHAIN -LOCK TYPE OR RUBBER GUYS TIED IN FIGURE EIGHT; REMOVE AFTER ONE GROWING SEASON PROTECTIVE WRAPPING DURING SHIPMENT TO SITE AND INSTALLATION REMOVE AT COMPLETION OF PLANTING LAWN PLANTING; PROVIDE TO "NO GRASS" TREE RING AND 2" DEEP MULCH LAYER IN WELL. HOLE) BACK FROM TRUNK 8" TO 10" REMOVE ALL WRAP, TIES, AND CONTAINERS SCORE ROOTBALL AND WORK NURSERY SOIL AWAY FROM PERIMETER ROOTS PREPARE PLANTING BED PER SPEG'S; AT MIN., LOSSEN AND MIX SOIL TO 18" OR DEPTH OF R007BALL AND 2 TIMES BALL DIAMETER SET BALL ON UNDISTURBED BASE OR COMPACTED MOUND UNDER BALL PENETRATION TO SUBBASE (+) 24" �D�EIDUOUS TREE �PLANTING �AN�DS TAKING 7 NOT TO SCALE Linear Application of DeepRoot Tree Root Barriers at Time of Installing Concrete Sidewalks and Curbs TYPICAL SECTION OF CURB AND GUTTER Wf H DEEPROOT -REE RDOT BARRIER INSET INTO CONCRETE, BARRIER INSTALLED IN ATRENLTI IN SUBGRADE WHICH 15 THEN COMPACHR BARRIER 15 SET SO THAT TOP EDGE MLL BE 2' (517M) BEI-OWFINISH GRADEOFCURB, AND SET FLUSH WITH EDGE OF CURB- BARRIER RIBS FACE MWARD TREE RDCITS. VSTAUATION SEQUENCE 1, Prepare base and subgrade come* 2. Trench to appropriate depth for Installation of • root barrier z thattop4barrier is Y (SEm) ;. Wow finish grade of top of curb. 3. Place root barrier in trench vertical ribs must face toward tree rants 4 Nckfrll and comp a to requirements. 5. Place farm material against barrier (It may be nal led from the outside of the form) T TYPICAL SECTION OF CURS, GUTTER AND SIDEWALK W7H DEEPRODTTREE ROOT BARRIER INSE71NM �.q CONCRETE MRRIER INSTALLED IN ATiIENCH IN SUBGRADE WHICH IS THEN C 01FAC M BARRIER 15 5ET SQ THAT WP EDGE VALL BE T (5CM) ABOVE COMPACTED BASE (or halfway between base and finish grade of SW}. BARRIER RIBS FACE TOWARk} TREE ROOTS. 'All v r 4 4 Suhgrade companion Compacted cruOk base. Ty0mI De%Root UB 24-Z optwnal use of UB 18.2 u�n Tap of roar barrier 2' ' - o 'A ficm)belowfrnish grade d c rb 41 ,�. _ tic 4:' w - •�•• �.. �i: .r 5-'� M1f. .. pp�� 5ubgrade W06mm} DeepRmAUB NI-2, UB m,2 or LR t2-2 Top of root bander 2' (5* bek m finish grade of curb S>7 FINISH GRADE LANDSCAPE AND PLANTING DETAILS OF FOREST TERRACE PLAT A PORTION OF SECTION 04, TOWNSHIP 23 N., RANGE 05 E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON (2) LODGEPOLE STAKES; TIE AT APPROX. V3 TO V2 HEIGHT OF TREE WITH FLEXIBLE RUBBER TIE IN FIGURE EIGHT PATTERN. STAKES AND TREE TO BE PLUMB. DO NOT INSTALL STAKES FOR TREES 3" DOH AND GREATER. 3" DEEP SAUCER FOR WATER MULCH LAYER ` REMOVE ALL TIES, WRAP & CONTAINERS. FREE PERIMETER ROOTS FROM NURSERY BALL EXCAVATE TREE PIT AT A MIN. Of 2 TIMES DIA. OF R007BALL AT BALL CENTER, TAPERING PIT GRADE TO ♦=iNISH GRADE PIT SPOILS, NURSERY BALL WASTE BACKFILL SET BALL ON UNDISTURBED SUBGRAOE. CR COMPACTED SOIL. NOTE: LIGHT FERTILIZER OVER PLANTING BED AFTER BACKFILL ONLY: NO FERTILIZER IN PLANTING PIT. WORK PERIMETER ROOTS FREE OF NURSERY BALL. BALL & PIT TO BE COURSELY SCARIFIED. v I EVERGREEN TREE PLANTING AND STAKING NOT TO SCALE Cwnpactedrnashedhase I„ .,', t4 3x THE ROOTBALL SubgradetanpaEtlon DIAMETER NOTE; ~ TypIEal QeepRoat UB 24-Z oprlonalusedUB18-2 APPLY ADDITIONAL 4 OZ, 5-32-16 FERTILIZER INTO TOP 2" OF PLANTING SOIL. PLANT SHRUB HIGH ENOUGH TO ALLOW POSITIVE DRAINAGE AWAY FROM ROOTBALL. ROUGHEN ALL SURFACES OF PIT, INSTALLATION SEQUENCE 1. Prepare base and subgTade 2.Tremh to appropriate depth for Installation of root barr}erso that top of barrier is 2" (Stm) below finish grade of top of sJdgwA (or halfway between top of compacted base and finish grade of 5W) 3. Place root barrier in t1nch,Yertk3l CorKreta ribs must fate toward tree roots. f 4. Backflll and compact to requirements. 5. Place fu m material against barrier (It may be nailed from the outside Of the form) Ifdt WANT NM; Tree WxIon must align wpih'�5-IlUlt' Elmer qr I)drtier, Muaimum6 panels ar k31'uleaTfeet [3,6dm1, SHRUB PLANTING NTS SHRUB -PRUNE AS DIRECTED BY LANDSCAPE ARCHITECT MULCH LAYER. HOLD MULCH BACK FROM STEM 4" SAUCER FOR WATERING BACKFILL WITH PLANTING SOIL. SEE NOTES SCARIFY ROOTBALL ON CONTAINER MATERIAL. REMOVE TOP 1f3 or BURLAP ON B&B MATERIAL DUST ROOT BALL WITH ROOT GROWTH HORMONE Sensitive Area Signs Per City of Renton Standards — Chamber Tap of Post 45 Degrees Gx6" Split Cedar Post Topn All Four Sides A Depth of V Zx6" Split Cedar Rails V, , 1 Attach Pre -Printed Metal Sign To Past io With Two 5/8- Din. Galvanired b Carriage Bolts m Pitch Surface ra Drain TREE PROTECTION SIGN- Finish Elevation SEE DETAIL ABOVE IT Concrete Foaling --6aekfzH With Native Swl d" --i--€ampatted Granular Sub -Rare 12, Post Connectic SPLIT -RAIL FENCE WITH SENSITIVE AREA SIGNS NTS NOT TO SCALE BENCHMARK FOUND PUNCHMARK IN 1%- BRASS FOUND PUNCHMARK IN BRASS PIN DATUM "ti A TI Il ■ DISK IN CONCRETE MONUMENT IN CASE IN CONCRETE MONUMENT IN CASE LJI�''k 1 VIYI 0.4' BELOW GRADE (7/20/2017) 1.4- BELOW GRADE (7/20/2017) HORIZONTAL DATUM: VERTICAL DATUM: OBSERVED (NAD 83/11) OBSERVED (NAD 83/11) NAD '83/' 1 1 NAVD '88 N:191092.94, E:131 1476.14 N:191241.77, E:131 1481.30 1 CITY OF RENTON 2ND REVIEW 2 CITY REVIEW COMMENTS 4113120 3 CITY REVIEW COMMENTS B17120 3 CITY & SECONDARY TREE REVIEW COMMENTS 9124120 NO. REVISION PROPOSED DECIDUOUS OR EVERGRE TF DO NOT MODIFY ROOT Be MULCH PER $PECIFICATIC ROUND -TOPPED S BERM b" HiGH X 8' W. ABOVE ROOT BALL $URFACE $He BE CENTERED ON THE ❑OWNF SIDE OF THE ROOT FALL FOR 2• BERM SHALL BEGIN AT ROOT 8+ PERI PHE JUTE FABRIC TO BE INSTALLED SLOPES STEEPER THAN 2:$ T3IROVG11C ALL LANDSCAPE BEDS WHERE TREE A TOBE INSTALLED.OVERLAPFABRLCEDC MINIMUM 12". METAL LANDSCAPE STAR 48" ON -CENTER ALONG ALL EDC TOPSOIL PER NOTES AND DETA TREE PLANTING ON SLOPE NOT TO SCALE NOTES 1. SEE PLANT SCHEDULE FOR GROUNDCOVER SPECIES, SIZE, AND SPACING. 2. REMOVE CONTAINER AND WORK ROOTS FREE OF SOIL- 1 HOLD PLANTS TWO-THIRDS {3) OF THE RECOMMENDED O.G. PLANT SPACING FROM EDGE OF PLANTING AREA- 4, SETTLE SOIL AROUND ROOT BALL OF EACH GROUNDCOVER PRIOR TO MULCHING. SOIL SHALL BE SETTLED USING WATER ONLY. DO NOT PLANT IN WET CONDITIONS, PROVIDE DRAINAGE FROM EACH PLANTING PIT IF NECESSARY- 6- ALL PLANTS SHALL BE INSTALLED PRIOR TO MULCHING. GRCUNDC0VER PLANTING 114" =V-0'" � a H* pmaMd and care far this a ►least cwtad cow ti Ilwn (MI �36• m nil h wnbuis w emm*L i TREE STAKE. PER SPECIFICATIONS ONE OF TWO SHOWN DO NOT PIERCE ROOTBALL WITH TREE STAKES. INSTALL STAKES ON SIDES OF TREES PARALLEL WITH SLOPE. DO NOT STAKE TREE$ WITH 3' DBH OR GREATER PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6' LIFTS TO BRACE TREE. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR W ATE R AROU ND THE ROOT BAL L TO SETTLE THE SOIL. MULCH PER NOTES AND DETAILS TOPSOIL PER NOTES AND DETAILS FINISHEDSU6-GRADE WITHOUT SPECIFIED TOPSOIL AND MULCH JUTE FABRIC FINISHED SUB -GRADE BOTTOM OF ROOT BALL RESTS ON EXISTING OR RECOMPACTED SOIL. POSITION CROWN OF PLANT "' ABOVE FINISH GRADE. 3" MULCH (1.5" BARK OR WOOD CHIP MULCH ON TOP OF 1.5" FINE COMPOST) FINISH GRADE. FEATHER EXCESS SOIL UNDER MULCH. PREPARED SUBGRADE. ROTOTILL FIRST LIFT OF PLANTING SOIL INTO PREPARED SUBGRADE. 5' to grade — GREENBACKGROUND SIMILAR TO REST OF SIGN BACKGROUND EVERGREEN TREES IN PROFILE PAINTED BLACK d Pre-printed metal sign 8.5 x 11 or 11x17as determined by the city with two 5/16 8'- 44 cedar or galvanized lag baits pressure -treated past with washers set 3' into hole FREE-STANDING TREE PROTECTION SIGN NOT TO SCALE JLB 211012020 JLB s"ieo° J.MV 41281)020 JMV Asa imv TCR 5107f2020 JMV TCR 912412020 JMV JfvtV CHECKED' JMV BY DATE APPR APo- imv StJLLE: AS NOTED AT FULL 5CJ1LE IF NOT ❑NE I CH SCALE JICCDRD1FK;Ly vERiIGL: ri+kvl] 1986 HMZONTnL: cup I M/199r C A.TIJ hrl - L % CITY OF RENTON Plonning%Building%Public Works Dept. Know what's below. Gail before you dig. Dial 811 3" DEPTH MULCH LAYER. PLANTS SHALL BE f TRIANGULARLY SPACED. • EDGE OF PLANTING AREA. EDGE CONDITION VARIES. SEE PLANS. • s X = RECOMMENDED ON -CENTER SPACING n PLANT SPACING 1" = V_0" WAS 7714' � Ln _w 2 c� U CD V] Ln LiJ CL J ]C � 2 LLJ W rr3 CV 04 � � C3 (-,4CO } Q3 CO W I I LLLJ w r 3:1oLr) (DZ (14 Li) LrD W W LLJ > Y U Zen z LU t� R-404861 ¢ 4 CL CURRENT PLANNING t,} Herrera 11 /23/2020 W co cb DEVELOPMENT ENGINEERING0 msippo 021112021 C < 0o LANDSCAPE AND PLANTING DETAILS DATE:9/27/20 m FOREST TERRACE PLAT PULTE GROUP, INC 3535 FACTORIA BLVD S.E., #110 BELLEVUE, OVA 98006 U W Ir � . U Cd rFELDEQ01i: PACE, "0: SMUT;74 OF: