HomeMy WebLinkAboutR-404861Uj
W
l—
I—
LLI
0
U_
CD
Q
NOTES
1. KEEP ROOTBALL MOIST AND PROTECTED AT ALL TIMES,
2. HOLD CROWN OF ROOTBALL AT OR JUST ABOVE FINISH GRADE.
3. PROTECT TRUNK AND LIMBS FROM INJURY.
4, BACKFILL TO BE SETTLED USING WATER ONLY - NC MECHANICAL COMPACTION.
5- REMOVE ALL WRAP, TIES & CONTAINERS, REGARDLESS OF MATERIAL -
PRUNE DAMAGED TWIGS AFTER PLANTING
PLACE IN VERT. POSITION: DOUBLE LEADERS WILL BE REJECTED
(2) LODGEPOLE STAKES, PLUMB WITH ELASTIC CHAIN -LOCK TYPE
OR RUBBER GUYS TIED IN FIGURE EIGHT; REMOVE AFTER ONE
GROWING SEASON
PROTECTIVE WRAPPING DURING SHIPMENT TO SITE AND
INSTALLATION REMOVE AT COMPLETION OF PLANTING
LAWN PLANTING; PROVIDE TO "NO GRASS" TREE RING AND 2"
DEEP MULCH LAYER IN WELL. HOLE) BACK FROM TRUNK 8" TO 10"
REMOVE ALL WRAP, TIES, AND CONTAINERS SCORE
ROOTBALL AND WORK NURSERY SOIL AWAY FROM
PERIMETER ROOTS
PREPARE PLANTING BED PER SPEG'S; AT MIN., LOSSEN
AND MIX SOIL TO 18" OR DEPTH OF R007BALL AND 2
TIMES BALL DIAMETER
SET BALL ON UNDISTURBED BASE OR COMPACTED
MOUND UNDER BALL
PENETRATION TO SUBBASE (+) 24"
�D�EIDUOUS TREE �PLANTING �AN�DS TAKING
7
NOT TO SCALE
Linear Application of DeepRoot Tree Root Barriers at Time
of Installing Concrete Sidewalks and Curbs
TYPICAL SECTION OF CURB AND GUTTER Wf H DEEPROOT
-REE RDOT BARRIER INSET INTO CONCRETE,
BARRIER INSTALLED IN ATRENLTI IN SUBGRADE WHICH 15
THEN COMPACHR BARRIER 15 SET SO THAT TOP EDGE
MLL BE 2' (517M) BEI-OWFINISH GRADEOFCURB, AND SET
FLUSH WITH EDGE OF CURB- BARRIER RIBS FACE MWARD
TREE RDCITS.
VSTAUATION SEQUENCE
1, Prepare base and subgrade come*
2. Trench to appropriate depth for Installation of •
root barrier z thattop4barrier is Y (SEm) ;.
Wow finish grade of top of curb.
3. Place root barrier in trench vertical ribs must
face toward tree rants
4 Nckfrll and comp a to requirements.
5. Place farm material against barrier (It may be
nal led from the outside of the form)
T
TYPICAL SECTION OF CURS, GUTTER AND SIDEWALK
W7H DEEPRODTTREE ROOT BARRIER INSE71NM
�.q
CONCRETE
MRRIER INSTALLED IN ATiIENCH IN SUBGRADE
WHICH IS THEN C 01FAC M BARRIER 15 5ET
SQ THAT WP EDGE VALL BE T (5CM) ABOVE
COMPACTED BASE (or halfway between base
and finish grade of SW}. BARRIER RIBS
FACE TOWARk} TREE ROOTS.
'All
v
r 4 4
Suhgrade companion
Compacted cruOk base.
Ty0mI De%Root UB 24-Z
optwnal use of UB 18.2
u�n
Tap of roar barrier 2'
' - o 'A
ficm)belowfrnish
grade d c rb
41
,�. _
tic
4:' w -
•�•• �.. �i:
.r 5-'�
M1f. ..
pp��
5ubgrade
W06mm} DeepRmAUB NI-2,
UB m,2 or LR t2-2
Top of root bander 2' (5* bek m
finish grade of curb
S>7
FINISH
GRADE
LANDSCAPE AND PLANTING DETAILS
OF
FOREST TERRACE PLAT
A PORTION OF SECTION 04, TOWNSHIP 23 N., RANGE 05 E., W.M.
CITY OF RENTON, KING COUNTY, WASHINGTON
(2) LODGEPOLE STAKES; TIE AT APPROX. V3 TO V2
HEIGHT OF TREE WITH FLEXIBLE RUBBER TIE IN FIGURE
EIGHT PATTERN. STAKES AND TREE TO BE PLUMB. DO
NOT INSTALL STAKES FOR TREES 3" DOH AND GREATER.
3" DEEP SAUCER FOR WATER
MULCH LAYER `
REMOVE ALL TIES, WRAP & CONTAINERS.
FREE PERIMETER ROOTS FROM NURSERY
BALL
EXCAVATE TREE PIT AT A MIN. Of 2 TIMES
DIA. OF R007BALL AT BALL CENTER,
TAPERING PIT GRADE TO ♦=iNISH GRADE
PIT SPOILS, NURSERY BALL WASTE BACKFILL
SET BALL ON UNDISTURBED SUBGRAOE.
CR COMPACTED SOIL.
NOTE:
LIGHT FERTILIZER OVER PLANTING BED AFTER BACKFILL
ONLY: NO FERTILIZER IN PLANTING PIT.
WORK PERIMETER ROOTS FREE OF NURSERY BALL.
BALL & PIT TO BE COURSELY SCARIFIED.
v I
EVERGREEN TREE PLANTING AND STAKING
NOT TO SCALE
Cwnpactedrnashedhase I„ .,', t4
3x THE ROOTBALL
SubgradetanpaEtlon DIAMETER
NOTE;
~ TypIEal QeepRoat UB 24-Z
oprlonalusedUB18-2 APPLY ADDITIONAL 4 OZ, 5-32-16 FERTILIZER INTO TOP
2" OF PLANTING SOIL.
PLANT SHRUB HIGH ENOUGH TO ALLOW POSITIVE DRAINAGE AWAY
FROM ROOTBALL. ROUGHEN ALL SURFACES OF PIT,
INSTALLATION SEQUENCE
1. Prepare base and subgTade
2.Tremh to appropriate depth for
Installation of root barr}erso that
top of barrier is 2" (Stm) below
finish grade of top of sJdgwA (or
halfway between top of compacted base
and finish grade of 5W)
3. Place root barrier in t1nch,Yertk3l
CorKreta ribs must fate toward tree roots.
f 4. Backflll and compact to requirements.
5. Place fu m material against barrier
(It may be nailed from the outside
Of the form)
Ifdt WANT NM; Tree WxIon must align
wpih'�5-IlUlt' Elmer qr I)drtier,
Muaimum6 panels ar k31'uleaTfeet [3,6dm1,
SHRUB PLANTING
NTS
SHRUB -PRUNE AS DIRECTED
BY LANDSCAPE ARCHITECT
MULCH LAYER. HOLD MULCH BACK
FROM STEM
4" SAUCER FOR WATERING
BACKFILL WITH PLANTING SOIL. SEE NOTES
SCARIFY ROOTBALL ON CONTAINER
MATERIAL. REMOVE TOP 1f3 or
BURLAP ON B&B MATERIAL
DUST ROOT BALL WITH
ROOT GROWTH HORMONE
Sensitive Area Signs Per
City of Renton Standards
— Chamber Tap of
Post 45 Degrees
Gx6" Split Cedar Post Topn All Four Sides
A Depth of V
Zx6" Split Cedar Rails
V, ,
1 Attach Pre -Printed
Metal Sign To Past
io With Two 5/8-
Din. Galvanired
b Carriage Bolts
m
Pitch Surface ra Drain TREE PROTECTION SIGN-
Finish Elevation SEE DETAIL ABOVE
IT
Concrete Foaling
--6aekfzH With Native Swl
d" --i--€ampatted Granular Sub -Rare
12,
Post Connectic
SPLIT -RAIL FENCE WITH SENSITIVE AREA SIGNS
NTS NOT TO SCALE
BENCHMARK
FOUND PUNCHMARK IN 1%- BRASS FOUND PUNCHMARK IN BRASS PIN
DATUM
"ti A TI Il ■ DISK IN CONCRETE MONUMENT IN CASE IN CONCRETE MONUMENT IN CASE
LJI�''k 1 VIYI 0.4' BELOW GRADE (7/20/2017) 1.4- BELOW GRADE (7/20/2017)
HORIZONTAL DATUM: VERTICAL DATUM: OBSERVED (NAD 83/11) OBSERVED (NAD 83/11)
NAD '83/' 1 1 NAVD '88 N:191092.94, E:131 1476.14 N:191241.77, E:131 1481.30
1 CITY OF RENTON 2ND REVIEW
2 CITY REVIEW COMMENTS 4113120
3 CITY REVIEW COMMENTS B17120
3 CITY & SECONDARY TREE REVIEW COMMENTS 9124120
NO.
REVISION
PROPOSED DECIDUOUS OR EVERGRE
TF
DO NOT MODIFY ROOT Be
MULCH PER $PECIFICATIC
ROUND -TOPPED S
BERM b" HiGH X 8' W.
ABOVE ROOT BALL $URFACE $He
BE CENTERED ON THE ❑OWNF
SIDE OF THE ROOT FALL FOR 2•
BERM SHALL BEGIN AT ROOT 8+
PERI PHE
JUTE FABRIC TO BE INSTALLED
SLOPES STEEPER THAN 2:$ T3IROVG11C
ALL LANDSCAPE BEDS WHERE TREE A
TOBE INSTALLED.OVERLAPFABRLCEDC
MINIMUM 12". METAL LANDSCAPE STAR
48" ON -CENTER ALONG ALL EDC
TOPSOIL PER NOTES AND DETA
TREE PLANTING ON SLOPE
NOT TO SCALE
NOTES
1. SEE PLANT SCHEDULE FOR
GROUNDCOVER SPECIES,
SIZE, AND SPACING.
2. REMOVE CONTAINER AND
WORK ROOTS FREE OF
SOIL-
1 HOLD PLANTS TWO-THIRDS
{3) OF THE RECOMMENDED
O.G. PLANT SPACING FROM
EDGE OF PLANTING AREA-
4, SETTLE SOIL AROUND
ROOT BALL OF EACH
GROUNDCOVER PRIOR TO
MULCHING. SOIL SHALL BE
SETTLED USING WATER
ONLY.
DO NOT PLANT IN WET
CONDITIONS, PROVIDE
DRAINAGE FROM EACH
PLANTING PIT IF
NECESSARY-
6- ALL PLANTS SHALL BE
INSTALLED PRIOR TO
MULCHING.
GRCUNDC0VER PLANTING
114" =V-0'"
� a
H* pmaMd and care far this a
►least cwtad cow ti Ilwn (MI �36• m
nil h wnbuis w emm*L
i
TREE STAKE. PER SPECIFICATIONS ONE OF
TWO SHOWN DO NOT PIERCE ROOTBALL WITH
TREE STAKES. INSTALL STAKES ON SIDES OF
TREES PARALLEL WITH SLOPE. DO NOT STAKE
TREE$ WITH 3' DBH OR GREATER
PRIOR TO MULCHING, LIGHTLY TAMP
SOIL AROUND THE ROOT BALL IN 6'
LIFTS TO BRACE TREE. DO NOT OVER
COMPACT. WHEN THE PLANTING
HOLE HAS BEEN BACKFILLED, POUR
W ATE R AROU ND THE ROOT BAL L TO
SETTLE THE SOIL.
MULCH PER NOTES AND DETAILS
TOPSOIL PER NOTES AND DETAILS
FINISHEDSU6-GRADE WITHOUT
SPECIFIED TOPSOIL AND MULCH
JUTE FABRIC
FINISHED SUB -GRADE
BOTTOM OF ROOT BALL RESTS ON
EXISTING OR RECOMPACTED SOIL.
POSITION CROWN OF PLANT
"' ABOVE FINISH GRADE.
3" MULCH (1.5" BARK OR
WOOD CHIP MULCH ON TOP
OF 1.5" FINE COMPOST)
FINISH GRADE. FEATHER
EXCESS SOIL UNDER MULCH.
PREPARED SUBGRADE.
ROTOTILL FIRST LIFT OF
PLANTING SOIL INTO
PREPARED SUBGRADE.
5' to grade
— GREENBACKGROUND
SIMILAR TO
REST OF SIGN BACKGROUND
EVERGREEN TREES IN
PROFILE PAINTED BLACK
d Pre-printed
metal sign
8.5 x 11 or
11x17as
determined
by the city
with two 5/16 8'- 44 cedar or
galvanized lag baits pressure -treated past
with washers set 3' into hole
FREE-STANDING TREE PROTECTION SIGN
NOT TO SCALE
JLB
211012020
JLB
s"ieo°
J.MV
41281)020
JMV
Asa
imv
TCR
5107f2020
JMV
TCR
912412020
JMV
JfvtV
CHECKED'
JMV
BY
DATE
APPR
APo-
imv
StJLLE:
AS NOTED
AT FULL 5CJ1LE
IF NOT ❑NE I CH
SCALE JICCDRD1FK;Ly
vERiIGL: ri+kvl] 1986
HMZONTnL: cup I M/199r
C A.TIJ hrl
- L
% CITY OF
RENTON
Plonning%Building%Public Works Dept.
Know what's below.
Gail before you dig.
Dial 811
3" DEPTH MULCH LAYER.
PLANTS SHALL BE
f TRIANGULARLY SPACED.
•
EDGE OF PLANTING
AREA. EDGE CONDITION
VARIES. SEE PLANS.
• s
X = RECOMMENDED
ON -CENTER SPACING n
PLANT SPACING
1" = V_0"
WAS
7714' �
Ln
_w
2
c� U
CD
V]
Ln
LiJ
CL J
]C
�
2
LLJ
W
rr3 CV
04
� �
C3 (-,4CO
} Q3
CO
W
I
I
LLLJ
w
r
3:1oLr)
(DZ
(14
Li)
LrD
W W
LLJ
>
Y
U Zen
z
LU
t�
R-404861 ¢ 4
CL
CURRENT PLANNING t,}
Herrera 11 /23/2020
W
co
cb
DEVELOPMENT ENGINEERING0
msippo 021112021
C
<
0o
LANDSCAPE AND PLANTING DETAILS
DATE:9/27/20
m
FOREST TERRACE PLAT
PULTE GROUP, INC
3535 FACTORIA BLVD S.E., #110
BELLEVUE, OVA 98006
U
W
Ir
�
.
U
Cd
rFELDEQ01i:
PACE,
"0:
SMUT;74 OF: