Loading...
HomeMy WebLinkAbout20180398E003 Renton ES 16 2022-06-25 FR 029 Kirkland | Tacoma | Mount Vernon 425-827-7701| www.aesgeo.com Date Mailed: Principal / PM: Bruce Guenzler, L.G., L.E.G. This document is considered a DRAFT until signed or initialed by an AESI Principal or Project Manager Page 1 of 1 v.7.20 FIELD REPORT Date Project Name Project No. Report No. 06/25/2022 Renton Elementary School 16 20180398E003 029 Location Municipality AESI Project Manager AESI Field Rep 1075 Duvall Ave NE Renton Bruce Guenzler, L.E.G. Scott R. Hannah, L.G. Permit No. Client/Owner Attn Requested By B21004604 Renton School District No. 403 Ed Thomson Client Engineer/Architect General Contractor Grading Contractor Weather CPL / Hutteball + Oremus Cornerstone/Kyle Continental Dirt Contractors/ Jerry Jr. Sunny, 80’s THE FOLLOWING WAS NOTED: Grading North: A representative from Associated Earth Sciences, Inc. (AESI) was onsite at 9am and again at 2pm, as requested to observe aerated soil conditions. Soils placed mid-day yesterday had been aerated by discing and were smoothed and re-rolled. During our morning visit we observed that the soils were still yielding in places and compaction was approximately 90%. CDC planned to aerate the rest of the day. Upon our return at 2pm we recommended that CDC compact two strips (east-west and north-south) to check progress. The soils had dried to moistures of 10-11% but density tests were still in the low 90’s and were still yielding in places. We discussed that some of the stockpile soils might be wetter. CDC planned to let the soils set as is for the rest of the weekend and check on Monday. Eastern soil stockpile Stormwater Facility #2 Green outlines represent fill proposed 1’- 5’ thick.