Loading...
HomeMy WebLinkAboutR-421504w 75 O z O z CW G n O LL1 > LL1 LU J Q U CI W P2 Q U I n N N w Q z L, AS -BUILT NOTE: LOCATIONS AND DIMENSIONS OF AS -BUILT STRUCTURES AND UTILITIES HAVE BEEN OBTAINED FROM FIELD MEASUREMENTS AND OBSERVATIONS PROVIDED FROM THE CONTRACTOR AND NOT BY SURVEY. a 0 N CASTLE DEVELOPMENT TOWNHOMES RECORD DRAWINGS SW 114 OF SE 114 OF SECTION 18, T. 23 N., R. 05 E., W.M. CITY OF RENTON, STATE OF WASHINGTON I � z .. a . Of d, •d w � 0 a ° I SEE NORTH SIDEWALK DOWNSPOUT . CONNECTION DETAIL CONNECTION m THIS SHEET FOR IE=24.98 GRADING DETAILS ° d. d d d d ° e = :...a •.. OW DEDICATION - SD SD - SD - - Q „ I 4' PERMEABLE . . . . . . - - - =, :' PAVEMENT FG=27.0 o WALKWAY f- _ ROOF DRAIN UNIT C 27.75 DOWNSPOUT CONNECTION FFE=�S IE=25.2 27.75 . 10 LF PERFORATED PIPE CB. 10. CONNECTION PER COR RIM. E L.. a STD PLAN 263.40 (TYP) 25.64' .1 E= 23.7.4'- . a . IE=23.74' „ TYPE 1 CB, W/ SOLID LID c� PER COR STD PLAN 200.00 AND COR STD PLAN 225.00 N _ RIM=26.7 2775 12"IIE 24.1 ((W)) rTT- Q " LU SDMH #1 UNIT B TYPE 2 RIM E L, U :. ':.4.. PERM ABLE FFE=z�$�5- 26.51 ' :. . PAWME:.T `• ' •'. 27.75 IE=16.51' WA�KA' 10 LF PERFORATED PIPE _ o CONNECTION PER COR STD PLAN 263.40 (TYP) ROOF DRAIN 27 .. . y DOWNSPOUT CONNECTION IE=24.5 BSBL (TYP) ROOF EAVE UNIT A o MID) . I FFE=28. 7 27.75 r .' ••PA•R�E ' 'B�. ... AL W D SD SD SD r _ FG=26.6 . . . . . . . . . . . . . r o _J d 6" ROOF DRAIN ® ROOF DRAIN o d . SDCO (TYP) 0.50T MIN PER COR DOWNSPOUT STD PLAN 225.0 (TIP) CONNECTION SEE SOUTH SIDEWALK IE=24.60 d d, I CONNECTION DETAIL THIS SHEET FOR GRADING DETAILS SAWCUT EXISTING SIDEWALK (TYP) Encomt)ass ENGINEERING SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 ■ Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. ■ Cle Elum, WA 98922 ■ Phone: (509) 674-7433 U �pHILIp WAsh'IAj'd I ssIONALCs 0912012023 REVISION i "E OVERFLOW TO SOCO IE=25.1 6 x2O' LIMITED INFILTRATION TRENCH PER DETAIL SHEET 7 TOP OF ROCK=26.0 BOTTOM OF ROCK=24.0 IE=25.0, 6" 0 5 10 SCALE 1 " = 10' FG 28.0 28.5 UNIT C GARAGE :' ::.:::. •': .:•:: FFE=28.5 � �•: ; .: • �..''.:•'....•'.':.'.': • .': •'.': •'.... .b ROOF DRAIN/DOWNSPOUT CONNECTION : ' : , ': ; • ':: IE=25 5 - • dS AREA DRA N .•'• .., RIM=27.0 UNIT B GARAGE . IE=25.0, NE) FFE=28.0. ... <C .: 28.0 ` CONCRETE PAVEMENT AREA DRAIN WALKWAY (TYP) RIM=27.0 IE=24.6, 6 (S.E) •� SURVEYED: BUI DESIGNED: IWD DRAWN: TNF CHECKED: IWD AP P R APPROVED: cP ...� _memo FG=27.0 27.5 - ROOF DRAIN/DOWNSPOUT "•':ur: '.': '.': ':' CONNECTION IE=25.5, 6" UNI T A GARAGE Q FFE=27.5 ::. 27.5 n' =270 7 OVERFLOW TO SDCO 5'x12' LIMITED IE=24.70 INFILTRATION TRENCH PER DETAIL SHEET 7 TOP OF ROCK=25.6 BOTTOM OF ROCK=23.6 IE=24.6, 6" SCALE: 1 "=10' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M Know what's below. Call before you dig. CITY 0E RENTON Planning/Building/Public Works Dept I 1 I 1 I 2" HMA GRIND AND OVERLAY 1 FULL ALLEY WIDTH 1 I I I SAWCUT AND I REPLACE ASPHALT I (TYP.) 1 I EG 26.47 EG 26.63 1. Z (29. 1 fA)O Q 10 W QFG 26.50 NORTH SIDEWALK CONNECTION SCALE. 1 "=5' FG 26.24 EG EG 26.13 26,22 MATCH / I <d SOUTH SIDEWALK CONNECTION SCALE. FG 26.66 FG 26.62 - 26.36 26.32 Q 6" POROUS CONCRETE OR PERMEABLE PAVERS p p p p p 8" THICK i'-14" WASHED FRACTURED ROCK PERMEABLE PAVEMENT DRIVEWAY SECTION NOT TO SCALE Q 4" POROUS v a: Q CONCRETE OR PERMEABLE PAVERS p p p p p 6" THICK f-14" WASHED FRACTURED cz ROCK PERMEABLE PAVEMENT WALKWAY SECTION NOT TO SCALE DWG# R-421504 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CASTLE DEVELOPMENT TOWNHOMES AS -BUILT PRELIMINARY GRADING AND DRAINAGE PLAN DATE: 09/29/20 FIELDBOOK: PAGE: SHEET: OF: 4 7 O O O O O N N W u LLI 2 O z O z W 5 n O J W > W 0 LU I- a U