HomeMy WebLinkAbout360.2PRECAST CONCRETE VAULT WITH 3 - 3'x 3' ONE EACH SIDE 4"x 2 1/2" FIRE DEPARTMENT DOUBLE HINGED STEEL PLATE COVERS. DIMENSIONS CONNECTION FOR STAND PIPE WITH 5'-8"x 11'-2"x 7'-2" EQUAL TO UTILITY 4" ADAPTER, FL.x SCREWED BREAKABLE CAST IRON HOSE CAPS. VAULT OR EQUAL 4"x4"x6" BULL HEAD TEE, FL. ONE EACH SIDE EQUAL TO GRINNEL TOUCH READ PIT LID SENSORFIG. MOUNTED ON STEEL PLATE 6" PIPE FL.x 1682 WITH HOSE CAPS FIG. 1333. 6" SWING TYPE GRAVITY OPERATED COVER THROUGH 2" DIA. FL. 2'- 0" LO CHECK VALVE, FL. EQUAL TO DRILLED HOLE IN COVER. MUELLER CO. A-2600-6 WITH BALL THE BY-PASS ASSEMBLY SHALL BE 2'-6" DRIP VALVE AT BOTTOM INCLUDED AS PART OF THE DETECTOR DOUBLE CHECK VALVE ASSEMBLY. 18" FOR 10" ASSEMBLY INSTALL EPDXY NON -SHRINK GROUT (TYP.) 5/8"x3/4" SENSUS SRII (TR/PL) METER 17 1/2" FOR 8" ASSEMBLY 1 6" PIPE, FL.x FL 3'0" LONG WITH ICE REGISTER. 18 1/2" FOR 6" ASSEMBLY 3'-0' ICE REGISTER \ 11'- 2" 6"& 8" ASSEMBLY. 6" SHORT CITY PRIVATE _ RADIUS 90° BEND FL. Z PIPING PIPING a STORM DRAIN SYSTEM WITH 10" ASSEMBLY 90° 8"X6" REDUCING BEND FL. TEE (MJ x FL) (2�—" CATCH BASIN OR MANHOLE L:3'-2"6" VALVE (FL x MS) E 3/� 5'- 8" 90° BEND FLGATE 2�I m m m 1 m m m -TO CITY MAIN TO BUILDING 12" ALL AROUNDa2-6 DEADMAN BLOCK CONCRETE REQUIRED. BLOCKING 10",8",6" FL x MJ ADAPTOR ALL DETECTOR DOUBLE CHECK VALVE 10", 8" OR 6" FL.x P.E. ASSEMBLIES SHALL INCLUDE RESILIENT PIPE WITH COLLAR 18" SEATED SHUTOFF VALVES AND TEST PLAN 10" ASSEMBLY 10"x10%8"TEE FL. FROM P.E. COCKS. AND APPROVED 8" ASSEMBLY 8"x8"x6" TEE, FL. 6" CROSS -CONNECTION CONTROL ASSEMBLY 6'x6"x6" TEE, FL. 10"- 3'-8" LONG ASSEMBLIES PER DEPARTMENT OF 8"- 3'-6" LONG HEALTH LATEST APPROVED LIST. 10", 8", OR 6" GATE VALVE, FL.x MJ, 6"- 4'-0" LONG WITH INDICATOR POST. INDICATOR DOUBLE CHECK VALVE ASSEMBLY POST VALVE SAME SIZE AS DOUBLE INCLUDES TWO RESILIENT SEATED CHECK VALVE (MUELLER CO. OR SHUTOFF VALVES. EQUAL), PAINTED RED. 10", 8", OR 6" FLANGED COUPLING ADAPTER EQUAL TO ROMAC. 10", 8", OR 6" DUCTILE IRON CLASS 52 NIPPLE PIPE, CEMENT LINED, LENGTH TO FIT. TOUCH READ PIT LID SENSOR MOUNTED ON STEEL PLATE COVER THROUGH 2" DIA. NOTE: DRILLED HOLE IN COVER. 1. LOCATE VAULT IN PLANTING AREA, NOT IN PAVING. 2. 4" AND LARGER BENDS AND TEES TO BE CAST IRON CEMENT LINED. 3. TEMPORARY SUPPORT SHALL BE PROVIDED UNDER VALVES AT THE TIME OF INSTALLATION TO CENTER THE PIPE IN VAULT OPENING. AFTER COMPLETE INSTALLATION REMOVE THE TEMPORARY SUPPORT AND INSTALL ADJUSTABLE PIPE SUPPORT. 4. INSTALL GALVANIZED LADDER FOR ACCESS. 5. AFTER FIELD INSTALLATION, MAIN DDCVA AND BY-PASS DCVA MUST BE TESTED SATISFACTORILY BY A DEPT. OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST REPORT TO BE SUBMITTED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT. PRIOR TO ACTIVATION OF NEW LINE. 6. INSTALL BRASS Y4' FLARE TEST COCKS WITH Y4' FLARE CAPS. COMPACTED FOUNDATION GRAVEL ADJUSTABLE STEEL PIPE SUPPORT, STANCHIONS BOLTED TO FLOOR. CNIFI \/IC\A/ Y 6",8" & 10" DOUBLE DETECTOR CHECK STD. PLAN — 360.2 PUBLIC WORKS + DEPARTMENT ASSEMBLY WITH STANDPIPE OUTSIDE �N'ro INSTALLATION MARCH 2010 3" T 36"TO 42' 6" PIPE FL. x SCREW 18" FOR 10" ASSEMBLY 17 1/2" FOR 8" ASSEMBLY 18 1/2" FOR 6" ASSEMBLY 2'-6" 3' 2" 5/8"x3/4" INVENSYS TR -PL METER WITH 7'-2" ICE REGISTER 6" MIN. DRAIN TO DAYLIGHT OR STORM DRAIN SYSTEM WITH 6" 90° BEND FL.� CATCH BASIN OR MANHOLE ; 2'-11" GALVANIZED STEEL LADDER COMPACTED FOUNDATION GRAVEL ADJUSTABLE STEEL PIPE SUPPORT, STANCHIONS BOLTED TO FLOOR. CNIFI \/IC\A/ Y 6",8" & 10" DOUBLE DETECTOR CHECK STD. PLAN — 360.2 PUBLIC WORKS + DEPARTMENT ASSEMBLY WITH STANDPIPE OUTSIDE �N'ro INSTALLATION MARCH 2010