HomeMy WebLinkAboutzSet - WaterWATER PLAN GENERAL NOTES Standard Plan No. 300 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION. 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND "CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON-SITE. 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C 104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8 -MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10 -INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12 -INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS (OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING. 8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION. *`a, STD. PLAN - 300.0 PUBLIC WORxsWATER PLAN GENERAL NOTES DEPARTMENT MARCH 2010 w z J W I- Q Z TESTING DETAIL x 18 FT W a 0 NEW D.I. WATER LINE TAPPING TEE (MJxFL) VERTICAL CROSS(MJxFL) FOR POLYPIGGING TAPPING GATE VALVE (FL XMJ) 1—BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG TEMPORARY PLUG (MJ) WITH 2—INCH TAP 1—BLIND FLANGE ON BOTTOM AND 2—INCH BLOW—OFF ASSEMBLY 1—PLUG(MJ) WITH 2"TAP & 2" BLOW—OFF CONCRETE BLOCKING TEMPORARY BLOCK w z J K w H a 0 c� FINAL CONNECTION DETAIL z X w W -ALA-- �@ENEW D.I. WATER LINE AFTER ALL CLEANING BY POLYPIG, PRESSURE TESTING AND DISINFECTION, REMOVE TEMPORAY BLOCK & BLOW—OFF AND CONNECT TO VALVE WITH D.I. SLEEVE (MJ) & D.I. SPOOLS FINAL CONNECTION BY CITY FORCES NOTES: 1. TAPPING TEES SHALL BE MADE OF CAST IRON, DUCTILE IRON OR EPDXY—COATED STEEL. BOLTS AND NUTS SHAL BE COR—TEN. ALL TEES AND VALVES SHALL BE WATER TESTED BEFORE TAP 2. NO SIZE ON SIZE TAPS ON CAST—IRON WATER LINES. TAP SHALL BE AT LEAST 2" SMALLER DIAMETER THAN THE EXISTING MAIN. 3. NO WET TAP ON ASBESTOS CEMENT LINE OR STEEL LINE 4, WET—TAPPING OF EXISTING CITY OF RENTON WATER MAINS WILL BE DONE BY SPEER TAP OR SUPERIOR TAPPING INC. 5. CONTRACTOR SHALL POTHOLE AND VERIFY THE HORIZONTAL AND VERTICAL ALIGNMENT OF EXISTING LINE OR STUB AND SHALL START LAYING THE NEW LINE AT THE SAME HORIZONTAL AND VERTICAL ALIGNMENT OF THE EXISTING STUB. 6. CITY FORCES WILL PERFORM THE FINAL CONNECTION FROM THE WATER LINE TO THE TAPPING VALVE WITH D.I. SLEEVE AND D.I. SPOOL. �Y STD. PLAN — 300.1 as �+ PUBLIC WORKS CONNECTION TO WATER MAIN WITH DEPARTMENT TAPPING TEE & VALVE �N,�p MARCH 2010 TESTING CONNECTION 8'± TEMPORARY BLOCKING EXISTING WATER MAIN POLYPIG STATION PER STD PLAN 300.7 (1) VERTICAL CROSS (MJxFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW-OFF ASSEMBLY WITH TEMPORARY THRUST BLOCKING CONNECTION TO EXISTING MAIN (BY CITY FORCES) (1) TEE (MJxFL) (2) DI SPOOLS (2) LONG BODY DI SLEEVES (MJ) OR COUPLING ADAPTERS (ROMAC 501 OR EQUAL) (2) GATE VALVES (FLxMJ) (1) ADAPTER (FLxMJ) (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW-OFF ASSEMBLY WITH CONCRETE THRUST BLOCKING PER STD PLAN 330.1 FINAL CONNECTION NEW DI WATER MAIN UPON COMPLETION OF POLYPIGGING, HYDROSTATIC TESTING, AND DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING AND TEMPORARY BLOW-OFF ASSEMBLIES FINAL CONNECTION (BY CITY FORCES) (2) DI SPOOLS (1) LONG BODY DI SLEEVE (MJ) NEW DI WATER MAIN NOTES: 1.ALL CONNECTIONS TO EXISTING WATER MAINS WILL BE CONDUCTED BY CITY FORCES AS SPECIFIED IN SECTION 5-14.2 OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS 2.LONG BODY DI SLEEVE FOR CONNECTION FROM DI TO DI PIPE AND FROM DI TO CI PIPE WITH SAME OUTSIDE DIAMETER 3.COUPLING ADAPTORS FOR CONNECTION FROM DI TO CI PIPE WITH DIFFERENT O.D. AND FROM DI TO AC OR TO STEEL PIPE PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator CONNECTION TO WATER MAIN CUT-IN TEE AND TWO VALVES STD. PLAN - 300.2 6/28/2023 TESTING CONNECTION 8'± TEMPORARY BLOCKING EXISTING WATER MAIN POLYPIG STATION PER STD PLAN 300.7 (1) VERTICAL CROSS (MJxFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW-OFF ASSEMBLY WITH TEMPORARY THRUST BLOCKING CONNECTION TO EXISTING MAIN (BY CITY FORCES) (1) TEE (FLxFL) (2) DI SPOOLS (2) LONG BODY DI SLEEVES (MJ) OR COUPLING ADAPTERS (ROMAC 501 OR EQUAL) (3) GATE VALVES (FLxMJ) (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW-OFF ASSEMBLY WITH CONCRETE THRUST BLOCKING PER STD PLAN 330.1 FINAL CONNECTION NEW DI WATER MAIN UPON COMPLETION OF POLYPIGGING, HYDROSTATIC TESTING, AND DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING AND TEMPORARY BLOW-OFF ASSEMBLIES FINAL CONNECTION (BY CITY FORCES) (2) DI SPOOLS (1) LONG BODY DI SLEEVE (MJ) NEW DI WATER MAIN NOTES: 1.ALL CONNECTIONS TO EXISTING WATER MAINS WILL BE CONDUCTED BY CITY FORCES AS SPECIFIED IN SECTION 5-14.2 OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS 2.LONG BODY DI SLEEVE FOR CONNECTION FROM DI TO DI PIPE AND FROM DI TO CI PIPE WITH SAME OUTSIDE DIAMETER 3.COUPLING ADAPTORS FOR CONNECTION FROM DI TO CI PIPE WITH DIFFERENT O.D. AND FROM DI TO AC OR TO STEEL PIPE PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator CONNECTION TO WATER MAIN CUT-IN TEE AND THREE VALVES STD. PLAN - 300.3 6/28/2023 TESTING CONNECTION 10'± TEMPORARY BLOCKING POLYPIG STATION PER STD PLAN 300.7 (1) VERTICAL CROSS (MJxFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW-OFF ASSEMBLY WITH TEMPORARY THRUST BLOCKING FINAL CONNECTION NEW DI WATER MAIN UPON COMPLETION OF POLYPIGGING, HYDROSTATIC TESTING, AND DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING AND TEMPORARY BLOW-OFF ASSEMBLIES FINAL CONNECTION (BY CITY FORCES) (1) DI SPOOL (1) LONG BODY DI SLEEVE (MJ) EXISTING TEE, CAP, PLUG, OR DEAD END LINE, DO NOT DISTURB BLOCKING EXISTING WATER MAIN NEW DI WATER MAIN NOTES: 1.ALL CONNECTIONS TO EXISTING WATER MAINS WILL BE CONDUCTED BY CITY FORCES AS SPECIFIED IN SECTION 5-14.2 OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS 2.LONG BODY DI SLEEVE FOR CONNECTION FROM DI TO DI PIPE AND FROM DI TO CI PIPE WITH SAME OUTSIDE DIAMETER 3.LONG BARREL COUPLING FOR CONNECTION FROM DI TO CI PIPE WITH DIFFERENT O.D. AND FROM DI TO AC OR TO STEEL PIPE PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator CONNECTION TO WATER MAIN EXISTING TEE OR END LINE CAP STD. PLAN - 300.4 6/28/2023 TESTING CONNECTION 8'± TEMPORARY BLOCKING EXISTING WATER MAIN POLYPIG STATION PER STD PLAN 300.7 (1) VERTICAL CROSS (MJxFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW-OFF ASSEMBLY WITH TEMPORARY THRUST BLOCKING CONNECTION TO EXISTING MAIN (BY CITY APPROVED WET TAP CONTRACTOR) (1) TAPPING TEE (FL) PER STD PLAN 300.6 (1) TAPPING GATE VALVE (FLxMJ) (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW-OFF ASSEMBLY WITH CONCRETE THRUST BLOCKING PER STD PLAN 330.1 FINAL CONNECTION NEW DI WATER MAIN UPON COMPLETION OF POLYPIGGING, HYDROSTATIC TESTING, AND DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING AND TEMPORARY BLOW-OFF ASSEMBLIES FINAL CONNECTION (BY CITY FORCES) (2) DI SPOOLS (1) LONG BODY DI SLEEVE (MJ) NEW DI WATER MAIN 3 x ID MIN NOTES: 1.ALL CONNECTIONS TO EXISTING WATER MAINS WILL BE CONDUCTED BY CITY FORCES AS SPECIFIED IN SECTION 5-14.2 OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS 2.LONG BODY DI SLEEVE FOR CONNECTION FROM DI TO DI PIPE AND FROM DI TO CI PIPE WITH SAME OUTSIDE DIAMETER PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator CONNECTION TO WATER MAIN TAPPING TEE AND VALVE STD. PLAN - 300.5 6/28/2023 NOTES: 1.WET TAPPING OF EXISTING WATER MAINS SHALL BE PERFORMED BY A CITY APPROVED WET TAP CONTRACTOR (SPEER TAPS, INC., LEGACY TAPPING, INC. OR OTHER FIRM APPROVED BY CITY ENGINEER). 2.CONTRACTOR SHALL POTHOLE AND VERIFY THE HORIZONTAL AND VERTICAL ALIGNMENT OF EXISTING WATER MAIN AND SHALL LAY THE NEW WATER MAIN TO MATCH. 3.TAPPING TEE SHALL BE STAINLESS STEEL OR STEEL WITH FULL CIRCLE SEAL WITH CORTEN OR STAINLESS STEEL NUTS AND BOLTS. 4.ALL TEES AND VALVES SHALL BE WATER TESTED BEFORE TAPPING OR ASSEMBLY SEALS SHALL BE TESTED VIA AIR PRESSURE AFTER THE TAPPING SLEEVE IS INSTALLED TO THE MAIN AND THE TAPPING VALVE IS INSTALLED. 5.TAPPING TEES MAY BE SIZE-ON-SIZE, PROVIDED THE SHELL CUTTER DIAMETER IS AT LEAST 2" SMALLER THAN THE EXISTING MAIN DIAMETER. 6.TAPPING TEES SHALL NOT BE INSTALLED ON STEEL OR ASBESTOS CEMENT WATER MAINS. COMPACTED BEDDING GRAVEL PER SECTION 9-03.12(3) OF THE WSDOT STANDARD SPECIFICATIONS CONCRETE SUPPORT BLOCKS CONCRETE BLOCKING PER STD PLAN 330.1 MAIN NEW WATER MAIN ELEVATION PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator TAPPING TEE STD. PLAN - 300.6 6/28/2023 NOTES: 1.THE BACKFLOW PREVENTION ASSEMBLY AND SUPPLY HOSE MUST BE DISCONNECTED DURING HYDROSTATIC PRESSURE TESTING OF THE NEW WATER MAIN. 2.POLYPIG AND ALL DEBRIS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS VIA SANITARY METHOD PRIOR TO DISINFECTION OF NEW WATER MAIN. 3.UPON REMOVAL OF POLYPIG, REMOVE TEMPORARY BLOW-OFF ASSEMBLY AND INSTALL 2" PLUG. 4.THE NEW WATER MAIN SHALL BE CONNECTED TO THE EXISTING SYSTEM ONLY AFTER NEW WATER MAIN IS POLYPIGGED, DISINFECTED AND SATISFACTORY BACTERIOLOGICAL SAMPLE RESULTS ARE OBTAINED. 5.THE INTERIORS OF ALL PIPES AND FITTINGS TO BE USED IN FINAL CONNECTION MUST BE SWABBED OR SPRAYED WITH A 5-6% AVAILABLE CHLORINE SOLUTION. NEW DI WATER MAIN NSF 61 SUPPLY HOSE METERED BACKFLOW ASSEMBLY (TO BE OBTAINED FROM CITY) (1) 2 1 2" CONTROL VALVE (1) CONSTRUCTION METER (1) RPBA METER SUPPORT (BY CONTRACTOR) HYDRANT ON EXISTING WATER MAIN POLYPIG TEMPORARY BLOW-OFF ASSEMBLY (1) 2" GALVANIZED PIPE (1) 2" 90° BEND (1) 2" GATE VALVE POLYPIG STATION (1)VERTICAL CROSS (MJxFL), SIZE TO MATCH WATER MAIN (1)BLIND FLANGE WITH 2" TAP ON TOP OF CROSS (1)TEMPORARY BLOW-OFF ASSEMBLY (1)BLIND FLANGE ON BOTTOM OF CROSS (1) PLUG (MJ) ON END OF CROSS WITH TEMPORARY THRUST BLOCKING TEMPORARY BLOCKING PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator POLYPIGGING NEW WATER MAINS STD. PLAN - 300.7 6/28/2023 WATER MAIN (CARRIER PIPE) NOTES: 1.CASING SPACERS SHALL BE "CENTER POSITIONING" TYPE. 2.RUNNER WIDTH SHALL BE MINIMUM 2". 3.RUNNER HEIGHT SHALL BE SIZED TO PROVIDE: ·MINIMUM 3/4" BETWEEN CARRIER PIPE BELL AND CASING PIPE WALL AT ALL TIMES. ·MINIMUM 1" CLEARANCE BETWEEN RUNNERS AND TOP OF CASING WALL TO PREVENT JAMMING DURING INSTALLATION. 4.STEEL CASING DIAMETERS ARE "OUTSIDE DIAMETER" FOR 16" AND LARGER. 5.PROVIDE SHOP-APPLIED ANTI-CORROSIVE COATING ON CASING EXTERIOR CONFORMING TO AWWA C210. TNEMEC HI-BUILD TNEME-TAR SERIES 46H-413 OR EQUAL. MINIMUM COATING THICKNESS 16 MILS DFT, MAXIMUM COATING THICKNESS NOT TO EXCEED MANUFACTURER'S RECOMMENDATIONS. CASING END SEAL WITH STAINLESS STEEL BANDS (SEE APPROVED MATERIALS LIST), EACH END BLACK STEEL CASING PIPE ONE SPACER SHALL BE PLACED ON THE SPIGOT END OF EACH SEGMENT AT THE LINE MARKING THE LIMIT OF INSERTION INTO THE BELL. WHEN THE JOINT IS COMPLETE, THE SPACER SHALL BE IN CONTACT WITH THE BELL OF THE JOINT SO THAT THE SPACER PUSHES THE JOINT AND RELIEVES COMPRESSION WITHIN THE JOINT END SPACER, 12" MAX FROM END OF CASING CARRIER PIPE DIAMETER 4"6"8"10"12"16" CASING PIPE DIAMETER (PUSH-ON JOINT CARRIER PIPE)10"12"14"16"20"26" CASING PIPE DIAMETER (MJ/MEGALUG CARRIER PIPE)14"16"18"20"24"30" CASING PIPE WALL THICKNESS SCHEDULE 20 OR GREATER SPACER BAND WIDTH 8" CASING SPACER SEPARATION 10' MAX ON CENTER PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator STEEL PIPE CASING STD. PLAN - 300.8 6/28/2023 CL A HYDRANT COMPRESSION TYPE HYDRANT (SEE APPROVED MATERIALS LIST) WITH 6" MJ INLET WITH LUGS, 5 1 4" MVO, 1 1 4" PENTAGON OPERATING NUT, TWO (2) 2 1 2" NST HOSE NOZZLES, AND 4.875" SST PUMPER NOZZLE EQUIPPED WITH 5" STORZ ADAPTER AND 1/8" STAINLESS STEEL CABLE, WITH EXTENSION IF NECESSARY. TEE MAIN LINE TEE WITH 6" FLANGE SIDE OUTLET VALVE 6" GATE VALVE (FLxMJ) VALVE BOX VALVE BOX AND LID PER STD PLAN 330.7 PIPE CLASS 52 DI, LENGTH TO FIT JOINT RESTRAINT MECHANICAL JOINT RESTRAINT WITH CONCRETE BLOCKING OR (2) 3/4" CORTEN STEEL TIE RODS GRAVEL 1 1 4" WASHED DRAIN ROCK, MINIMUM 1' ABOVE BOOT FLANGE WITH 8-MIL POLYETHYLENE SHEETING AROUND TOP AND SIDES OF GRAVEL CONCRETE BLOCK MINIMUM 16"x8"x4" CONCRETE BLOCKS UNDER FIRE HYDRANT AND GATE VALVE BLOCKING CONCRETE BLOCKING PER STD PLAN 330.1 SHEAR BLOCK 4'x4'x6" CONCRETE SHEAR BLOCK AROUND FIRE HYDRANT, SEE STANDARD DETAIL 310.2 PAVEMENT MARKER BLUE REFLECTIVE PAVEMENT MARKER PER STD PLAN 310.3 BE K MAIN ROADWAY OR NEAREST LANE CHANNELIZATION1' MIN A1' MIN 4"4" MINIMUM F MATERIALS NOTES: 1.FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF SAFETY YELLOW DTM ACRYLIC GLOSS OR ENAMEL PAINT. 2.PUMPER NOZZLE TO FACE ROADWAY OR AS DIRECTED BY RRFA. 3.A MINIMUM 3' RADIUS UNOBSTRUCTED WORKING AREA SHALL BE PROVIDED AROUND THE OUTSIDE OF THE HYDRANT. H H J G D C I B C D E F G H I J K F PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator FIRE HYDRANT ASSEMBLY STD. PLAN - 310.1 6/28/2023 4'x4'x6" CONCRETE SHEAR BLOCK 4'x4'x6" CONCRETE SHEAR BLOCK ONE MAN ROCK 1 1 1 6 1 6 3' MIN RADIUS UNOBSTRUCTED WORKING AREA AROUND OUTSIDE OF FIRE HYDRANT 3' MIN RADIUS UNOBSTRUCTED WORKING AREA AROUND OUTSIDE OF FIRE HYDRANT CUT FILL NOTE: 4'x4'x6" CONCRETE SHEAR BLOCK AROUND FIRE HYDRANT WITH EXPANSION JOINT AT BACK OF SIDEWALK, FINISH TO MATCH SIDEWALK, ALL CONCRETE SHALL BE MINIMUM 3,000 PSI AND SHALL BE MECHANICALLY MIXED - JOB SITE MIXING, HAND-MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator FIRE HYDRANT ASSEMBLY SHEAR BLOCK STD. PLAN - 310.2 6/28/2023 BLUE REFLECTIVE PAVEMENT MARKER, STIMSONITE MODEL C88 OR EQUAL, PLACED 4" FROM ROADWAY CENTERLINE AS INDICATED BELOW TWO LANE ROAD OFFSET MARKER ON SIDE STREETS WHERE THE HYDRANT IS WITHIN 20' OF A MAJOR STREET, THE MARKER SHALL BE INSTALLED ON THAT MAJOR STREET FOUR LANE ROAD OFFSET MARKER FIVE LANE ROAD OFFSET MARKER 4"0.7" MARKERMARKER MARKER MARKER PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator FIRE HYDRANT ASSEMBLY PAVEMENT MARKER STD. PLAN - 310.3 6/28/2023 CORPORATION STOP 1" BALL CORPORATION STOP WITH BALL VALVE, AWWA TAPERED THREAD (CC) INLET, QUICK JOINT OUTLET, FORD FB1000-4-Q-NL OR A.Y. MCDONALD 74701BQ TUBING 1" TYPE "K" SOFT COPPER TUBING METER SETTER 1" SETTER, QUICK JOINT INLET AND OUTLET, PADLOCK WINGS ON INLET ANGLE BALL VALVE, SINGLE CHECK VALVE ON OUTLET, FORD VBH74-15W-44-44-Q-NL, A.Y. MCDONALD 721-415WCQQ 44, OR MUELLER B-24701-6AN, INSTALL CENTERED AND SQUARED IN METER BOX, PROVIDE ADAPTERS FOR 5/8"x3/4" METERS WATER METER AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BY THE CITY METER BOX METER BOX, ARMORCAST A6001946PCX18, WITH METER BOX LID, ARMORCAST A6001969RCI-H7, TO READ "RENTON WATER" COUPLER AND PLUG COUPLER (PACK JOINT x PACK JOINT), FORD C4#-4#-Q-NL, WITH 1" GALVANIZED PLUG IF SERVICE LINE TO PROPERTY IS TO BE INSTALLED IN THE FUTURE GRAVEL 1 1 4" WASHED GRAVEL PROPERTY LINECITY PIPING PIPING PRIVATE F BCB A D E FINISHED GRADE SIDEWALK 9" TO 12" IN UNIMPROVED ROW, INSTALL METER BOX AT PROPERTY LINE WITH 1" COPPER TAILPIECE 21" TO 30" LOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVIDE SLACK IN SERVICE LINE TO METER 22 1 2° 24" TO 30" MAIN 12"PROPERTY LINEA MATERIALS B C D E F G G PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 1" WATER SERVICE STD. PLAN - 320.1 6/28/2023 A TEE 2" TAPPED REDUCING TEE (MJxFIPT)2" TAPPED REDUCING TEE (MJxFIPT) PIPE 2" BRASS NIPPLE (MIPT), 4" LENGTH 2" BRASS NIPPLE (MIPT), 4" LENGTH VALVE 2" GATE VALVE (FIPT) WITH SQUARE OPERATING NUT AND EXTENSION PER STD PLAN 330.7 2" GATE VALVE (FIPT) WITH SQUARE OPERATING NUT AND EXTENSION PER STD PLAN 330.7 VALVE BOX VALVE BOX AND LID PER STD PLAN 330.7 VALVE BOX AND LID PER STD PLAN 330.7 COUPLING 2" x 1 1 2" BRASS COUPLING (MIPT x PACK JOINT), FORD C44-76-Q-NL OR EQUAL 2" BRASS COUPLING (MIPT x PACK JOINT), FORD C84-77-Q-NL OR EQUAL TUBING 1 1 2" TYPE "K" SOFT COPPER TUBING 2" TYPE "K" SOFT COPPER TUBING BEND 1 1 2" 90° BRASS BEND (PACK JOINT x PACK JOINT OR PACK JOINT x FIPT), FORD L44-66-Q-NL OR L41-66-Q-NL OR EQUAL 2" 90° BRASS BEND (PACK JOINT x PACK JOINT OR PACK JOINT x FIPT), FORD L44-77-Q-NL OR L41-77-Q-NL OR EQUAL METER SETTER 1 1 2" VERTICAL METER SETTER WITH BYPASS, FLANGED ANGLE BALL VALVE AND PADLOCK WINGS ON INLET, ANGLE CHECK VALVE ON OUTLET, AND BALL VALVE ON BYPASS WITH PADLOCK WINGS, FORD VBH86-12B-11-66-Q-NL, A.Y. MCDONALD 730B-612WDFF665, OR MUELLER B-2427N (1 1 2"), BYPASS NOT PERMITTED ON IRRIGATION METERS 2" VERTICAL METER SETTER WITH BYPASS, FLANGED ANGLE BALL VALVE AND PADLOCK WINGS ON INLET, ANGLE CHECK VALVE ON OUTLET, AND BALL VALVE ON BYPASS WITH PADLOCK WINGS, FORD VBH87-12B-11-77-Q-NL, A.Y. MCDONALD 730B-612WDFF665, OR MUELLER B-2427N (2"), BYPASS NOT PERMITTED ON IRRIGATION METERS METER SPREADER 13 3 16" RIGID METER SPREADER (TEMPORARY)17 3 16" RIGID METER SPREADER (TEMPORARY) WATER METER AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE SUPPLIED AND INSTALLED BY CITY FORCES AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE SUPPLIED AND INSTALLED BY CITY FORCES METER BOX 17"X30" METER BOX, ARMORCAST A6001640PCX18, WITH METER BOX LID, ARMORCAST A6001947RCI-H7, TO READ "RENTON WATER" 17"X30" METER BOX, ARMORCAST A6001640PCX18, WITH METER BOX LID, ARMORCAST A6001947RCI-H7, TO READ "RENTON WATER" COUPLER 1 1 2" COUPLER (PACK JOINT x PACK JOINT), FORD C4#-6#-Q-NL OR EQUAL, WITH GALVANIZED PLUG IF PRIVATE SERVICE LINE IS NOT YET INSTALLED 2" COUPLER (PACK JOINT x PACK JOINT), FORD C4#-7#-Q-NL OR EQUAL, WITH GALVANIZED PLUG IF PRIVATE SERVICE LINE IS NOT YET INSTALLED GRAVEL CRUSHED ROCK BASE TO SUPPORT METER BOX, METER BYPASS TO BE EXPOSED CRUSHED ROCK BASE TO SUPPORT METER BOX, METER BYPASS TO BE EXPOSED B C D E F G H I J K L PROPERTY LINEPROPERTY LINEFINISHED GRADE SIDEWALK 21" TO 30"24" TO 30"12" IN UNIMPROVED ROW INSTALL METER BOX AT PROPERTY LINE WITH 12" COPPER TAILPIECE CITY PIPING PIPING PRIVATE A B C D G H I JK F L M MAIN MATERIALS 1 1/2" SERVICE 2" SERVICE 9" TO 12" F E M PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 1 1 2" AND 2" WATER SERVICE IN PLANTING STRIP STD. PLAN - 320.2 6/28/2023 PROPERTY LINEFINISHED GRADE SIDEWALK 21" TO 30"24" TO 30" CITY PIPING PIPING PRIVATE D G H I JK 9" TO 12" 12" M L A B C MAIN F A TEE 2" TAPPED REDUCING TEE (MJxFIPT)2" TAPPED REDUCING TEE (MJxFIPT) PIPE 2" BRASS NIPPLE (MIPT), 4" LENGTH 2" BRASS NIPPLE (MIPT), 4" LENGTH VALVE 2" GATE VALVE (FIPT) WITH SQUARE OPERATING NUT AND EXTENSION PER STD PLAN 330.7 2" GATE VALVE (FIPT) WITH SQUARE OPERATING NUT AND EXTENSION PER STD PLAN 330.7 VALVE BOX VALVE BOX AND LID PER STD PLAN 330.7 VALVE BOX AND LID PER STD PLAN 330.7 COUPLING 2" x 1 1 2" BRASS COUPLING (MIPT x PACK JOINT), FORD C44-76-Q-NL OR EQUAL 2" BRASS COUPLING (MIPT x PACK JOINT), FORD C84-77-Q-NL OR EQUAL TUBING 1 1 2" TYPE "K" SOFT COPPER TUBING 2" TYPE "K" SOFT COPPER TUBING BEND 1 1 2" 90° BRASS BEND (PACK JOINT x PACK JOINT OR PACK JOINT x FIPT), FORD L44-66-Q-NL OR L41-66-Q-NL OR EQUAL 2" 90° BRASS BEND (PACK JOINT x PACK JOINT OR PACK JOINT x FIPT), FORD L44-77-Q-NL OR L41-77-Q-NL OR EQUAL METER SETTER 1 1 2" VERTICAL METER SETTER WITH BYPASS, FLANGED ANGLE BALL VALVE AND PADLOCK WINGS ON INLET, ANGLE CHECK VALVE ON OUTLET, AND BALL VALVE ON BYPASS WITH PADLOCK WINGS, FORD VBH86-12B-11-66-Q-NL, A.Y. MCDONALD 730B-612WDFF665, OR MUELLER B-2427N (1 1 2"), BYPASS NOT PERMITTED ON IRRIGATION METERS 2" VERTICAL METER SETTER WITH BYPASS, FLANGED ANGLE BALL VALVE AND PADLOCK WINGS ON INLET, ANGLE CHECK VALVE ON OUTLET, AND BALL VALVE ON BYPASS WITH PADLOCK WINGS, FORD VBH87-12B-11-77-Q-NL, A.Y. MCDONALD 730B-612WDFF665, OR MUELLER B-2427N (2"), BYPASS NOT PERMITTED ON IRRIGATION METERS METER SPREADER 13 3 16" RIGID METER SPREADER (TEMPORARY)17 3 16" RIGID METER SPREADER (TEMPORARY) WATER METER AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE SUPPLIED AND INSTALLED BY CITY FORCES AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE SUPPLIED AND INSTALLED BY CITY FORCES METER BOX 17"X30" METER BOX, ARMORCAST A6001640PCX18, WITH METER BOX LID, ARMORCAST A6001947RCI-H7, TO READ "RENTON WATER" 17"X30" METER BOX, ARMORCAST A6001640PCX18, WITH METER BOX LID, ARMORCAST A6001947RCI-H7, TO READ "RENTON WATER" COUPLER 1 1 2" COUPLER (PACK JOINT x PACK JOINT), FORD C4#-6#-Q-NL OR EQUAL, WITH GALVANIZED PLUG IF PRIVATE SERVICE LINE IS NOT YET INSTALLED 2" COUPLER (PACK JOINT x PACK JOINT), FORD C4#-7#-Q-NL OR EQUAL, WITH GALVANIZED PLUG IF PRIVATE SERVICE LINE IS NOT YET INSTALLED GRAVEL CRUSHED ROCK BASE TO SUPPORT METER BOX, METER BYPASS TO BE EXPOSED CRUSHED ROCK BASE TO SUPPORT METER BOX, METER BYPASS TO BE EXPOSED B C D E F G H I J K L MATERIALS 1 1/2" SERVICE 2" SERVICE M E PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 1 1 2" AND 2" WATER SERVICE IN ROW BEHIND SIDEWALK STD. PLAN - 320.3 6/28/2023 ELEVATION PIPE SLEEVE V H O P T S J K L M N E D C A B U EB C D T Q PVC PIPE SLEEVE EPOXY SEALANT EPDM MODULAR SEAL, LINK-SEAL MODEL C WITH 316SS BOLTS AND NUTS PIPE 6" MIN 6" MIN 12" MIN 6" MIN 6" MIN 12" MIN 6" MIN 6" MIN R PLAN C F G I Q PIPE SLEEVE SEE DETAIL, THIS SHEET R Q PIPE SLEEVE SEE DETAIL THIS SHEET S A 12" MIN W PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 3", 4", AND 6" WATER METER STD. PLAN - 320.4 Sht. 1 of 2 6/28/2023 MATERIALS NOTES: 1.VAULTS SHOULD NOT BE INSTALLED IN AREAS WITH VEHICLE TRAFFIC. 2.ALL INTERIOR METAL INCLUDING PIPE, VALVES, AND FITTINGS TO BE PAINTED WITH TWO COATS OF EPOXY AS APPROVED BY THE ENGINEER. USE TNEMEC SERIES 135 CHEMBUILD MODIFIED POLYAMIDE EPOXY. APPLY PER MANUFACTURERS INSTRUCTIONS. 3.VAULT AND HATCH MODELS ARE PROVIDED AS REFERENCE. SHOP DRAWINGS SHALL BE SUBMITTED TO THE CITY FOR APPROVAL. 4.FOR 3" AND 4" METERS, USE 2" BYPASS MATERIALS, AND FOR 6" METERS, USE 3" BYPASS MATERIALS, AS INDICATED BELOW. 5.INSTALL WATER METER RADIO & BATTERY UNITS IN ACCESS HATCH PANELS WITH MINIMUM 6" SEPARATION. A VAULT MODEL NUMBERS METER SIZE VAULT BASE PIECE CENTER PIECE TOP PIECE ACCESS HATCH 3"676-WA NO. 676-BL NO. 676-MLW NO. 676-TL-2-332P HHD-1C 4"676-WA NO. 676-BL NO. 676-MLW NO. 676-TL-2-332P HHD-1C 6"4484-LA NO. 4484-BL NO. 4484-ML NO. 4484-TL-2-332P HHD-2D METER AMI WATER METER (SENSUS OMNI WITH INTERNAL STRAINER) WITH RADIO AND BATTERY UNIT METER TEST PORT 2" BRASS NIPPLE (MIPTxMIPT), 6" LONG, CONNECTED TO TEST PORT OF COMPOUND METER 1" BALLCORP (MIPTxFIPT), FORD FB1700-4-NL OR EQUAL, FOR 3" METER OR 1 1 2" BALLCORP (MIPTxFIPT), FORD FB1700-6-NL OR EQUAL, FOR 4" AND 6" METERS 2"X2 1 2" ADAPTER (MIPTxMNST) 2 1 2" CAP (FNST) ADAPTER FLANGED COUPLING ADAPTER, MEGAFLANGE SERIES 2100, OR EQUAL PIPE CLASS 53 DI PIPE (PExFL) VALVE (2) GATE VALVE (FLxFL) WITH HANDWHEEL PIPE SUPPORT ADJUSTABLE PIPE SADDLE SUPPORT, GRINNELL FIG 264 OR EQUAL, WITH BASE, BOLTED TO FLOOR SERVICE SADDLE (2) 2" NPT SADDLE, SMITH-BLAIR MODEL 313 OR EQUAL OR (2) 6"X3" TEE (MJxFL) BYPASS VALVE (2) 2" BRASS GATE VALVE (IPT) OR (2) 3" GATE VALVE (FLxFL) WITH 3" THREADED (IPT) FLANGE BEND (2) 2" 90° BEND OR (2) 3" 90° BEND BYPASS PIPE 2" GALVANIZED PIPE, EPOXY COATED, OR 3" GALVANIZED PIPE, EPOXY COATED BYPASS METER VALVE 2" STRAIGHT FLANGE BALL VALVE (FLxFIPT) WITH PADLOCK WINGS, FORD BF31-777W-NL OR EQUAL OR 3"x2" REDUCER WITH 2" BRASS NIPPLE BYPASS METER 2" AMI BYPASS METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BY THE CITY METER FLANGE 2" METER FLANGE (FLxFIPT), FORD CF31-77-NL OR EQUAL, OR 3"x2" REDUCER WITH 2" BRASS NIPPLE UNION 2" TWO-PART UNION OR 3" TWO-PART UNION TEE 2" TEE OR 3" TEE BUSHING 2"x3/4" BUSHING OR 3"x3/4" BUSHING WITH 3/4" PLUG WATER MAIN CLASS 52 DI PIPE WITH RESTRAINED JOINTS WALL FLANGE MIDSPAN PIPE RESTRAINT WITH CONCRETE BLOCKING PER STD PLAN 350.7 CONCRETE VAULT OLDCASTLE PRECAST VAULT, MODEL NUMBERS PER TABLE BELOW, OR EQUAL DRAIN MINIMUM 4" PVC FLOOR DRAIN, SLOPE TO STORM DRAIN OR DAYLIGHT TO DRAINAGE DITCH WITH WIRE MESH RODENT SCREEN AT DRAIN OUTLET, SEAL PIPE PENETRATION WITH WATER-TIGHT GROUT ACCESS HATCH TWO LOCKING HINGED ALUMINUM DOORS, TRAFFIC-RATED, WITH SLIP-RESISTANT TREATMENT, MARKED "WATER", LW PRODUCTS MODEL NUMBERS PER TABLE BELOW, OR EQUAL. LADDER GALVANIZED STEEL LADDER SECURED TO VAULT PER STD PLAN 350.8 GRAVEL FOUNDATION GRAVEL PER WSDOT STANDARD SPECIFICATIONS, 12" MINIMUM ALL DIRECTIONS B C D E F G H I J K L M N O P Q R S T U V W PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 3", 4", AND 6" WATER METER STD. PLAN - 320.4 Sht. 2 of 2 6/28/2023 FINISH GRADE MATERIALS A SAMPLING STATION SAMPLING STATION WITH COPPER VENT TUBE AND 1 4" PETCOCK VALVE IN LOCKABLE ALUMINUM ENCLOSURE, KUPFERLE ECLIPSE NO. 88 CORPORATION STOP 3 4" BALL CORPORATION STOP WITH BALL VALVE, AWWA TAPERED THREAD (CC) INLET, QUICK JOINT OUTLET, FORD FB1000-3-Q-NL OR A.Y. MCDONALD 74701BQ COPPER TUBING 3 4" TYPE "K" SOFT COPPER TUBING ADAPTER 3 4" COUPLING (MIPT x QUICK JOINT), FORD C84-33-Q-NL OR EQUAL BEND 3 4" 90° BRASS STREET ELL CURB STOP 3 4" CURB STOP (FIPT x FIPT), FORD Z11-333-NL OR EQUAL VALVE BOX VALVE BOX AND LID PER STD. PLAN 330.8 B C D E F G MAIN 221 2° 3'x3'x6" CONCRETE PAD WRAP EXTERIOR CASING PIPE IN POLYETHELENE SHEETING PRIOR TO INSTALLING CONCRETE PAD F C B A 1 4 " C D E E G E D PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator SAMPLING STATION ASSEMBLY STD. PLAN - 320.5 FOR INTERNAL USE ONLY NOTES: 1.MINIMUM BEARING AREA MUST BE ADJUSTED FOR PIPE SIZE, PRESSURE, AND SOIL CONDITIONS. 2.FITTINGS SHALL BE POLYWRAPPED PRIOR TO POURING CONCRETE BLOCKING. 3.CONCRETE BLOCKING SHALL BE CAST IN PLACE AND SHALL HAVE A MINIMUM OF 0.25 SF BEARING AREA AGAINST THE FITTING. 4.CONCRETE BLOCKING SHALL BEAR AGAINST FITTINGS ONLY AND SHALL BE CLEAR OF JOINTS TO PERMIT TAKING UP OR DISMANTLING JOINT. 5.CONTRACTOR SHALL INSTALL BLOCKING ADEQUATE TO WITHSTAND FULL HYDROSTATIC TEST PRESSURE AS WELL AS TO CONTINUOUSLY WITHSTAND OPERATING PRESSURE UNDER ALL CONDITIONS OF SERVICE. 6.ALL CONCRETE SHALL BE MECHANICALLY MIXED. JOB SITE MIXING, HAND-MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. 7.IN MUCK OR PEAT, ALL THRUSTS SHALL BE RESTRAINED BY PILES OR TIE RODS TO SOLID FOUNDATION OR MUCK OR PEAT SHALL BE REMOVED AND REPLACED WITH BALLAST OF SUFFICIENT STABILITY TO RESIST THRUST. 8.CONCRETE BLOCKING SHALL BE LEFT OPEN OR SHEETED FOR MINIMUM 24 HOURS. MINIMUM BEARING AREA AGAINST UNDISTURBED SOIL (SF) * PIPE SIZE PRESSURE (PSI) 4"200 300 2/(1) 3/(2) 1/(NONE ) 2/(2) 1/(NONE ) 2/(1) NONE 1/(1) NONE NONE 6"200 300 4/(3) 6/(4) 3/(2) 4/(3) 3/(1) 3/(2) 1/(1) 2/(1) 1/(NONE ) 1/(NONE ) 8"200 300 7/(5) 11/(8) 5/(3) 8/(5) 4/(3) 6/(4) 2/(2) 3/(2) 1/(1) 2/(1) 10"200 275 11/(8) 16/(11) 8/(6) 11/(7) 6/(4) 9/(6) 3/(2) 5/(3) 2/(1) 3/(2) 12"200 250 16/(11) 24/(16) 11/(8) 17/(11) 9/(6) 13/(9) 5/(3) 7/(5) 3/(2) 4/(3) 14"200 250 22/(13) 33/(22) 16/(11) 23/(16) 12/(8) 18/(12) 6/(4) 9/(6) 3/(2) 5/(3) 16"200 225 29/(19) 32/(21) 21/(14) 23/(16) 16/(11) 17/(12) 8/(6) 9/(6) 5/(3) 5/(3) 18"200 36/(24)26/(17)20/(13)10/(7)5/(4) 20"200 45/(29)32/(21)24/(16)13/(8)7/(4) 24"200 64/(43)46/(30)35/(23)18/(12)9/(6) * VALUES BASED ON SAFE BEARING LOAD OF 2,000/(3,000) PSF SOIL TYPE SAFE BEARING LOAD (PSF) MUCK OR PEAT 0 SOFT CLAY 1,000 SAND 2,000 SAND AND GRAVEL 3,000 CEMENTED WITH CLAY 4,000 HARD SHALE 10,000 E B D A C B A B C D E 11 1 4° BEND 22 1 2° BEND 45° BEND90° BEND CAP / PLUG TEE PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator CONCRETE BLOCKING FOR HORIZONTAL FITTINGS STD. PLAN - 330.1 6/28/2023 NOTES: 1.CONCRETE BLOCKING SIZES BASED ON 200 PSI HYDROSTATIC PRESSURE AND 3,000 PSI CONCRETE. 2.ALL CONCRETE SHALL BE MECHANICALLY MIXED. JOB SITE MIXING, HAND-MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. 3.PIPE CLAMPS AND ANCHOR RODS SHALL BE INSTALLED PER STD PLAN 330.4. 4.FITTINGS SHALL BE POLYWRAPPED AFTER INSTALLATION OF PIPE CLAMPS AND ANCHOR RODS PRIOR TO POURING CONCRETE BLOCKING. 5.WATER MAIN SHALL NOT BE PRESSURIZED UNTIL ALL TRENCHING WITHIN 100' OF VERTICAL BEND IS BACKFILLED AND COMPACTED TO MINIMUM 3' COVER. 6.CONCRETE BLOCKING SHALL BE LEFT OPEN OR SHEETED FOR MINIMUM 24 HOURS. MINIMUM DIMENSIONS PIPE SIZE BEND VOLUME (CF)A D *L 4" 11 1 4°8 2.0'3 4"1.5' 22 1 2°11 2.2' 3 4"2.0' 45°30 3.1' 6" 11 1 4°11 2.2' 3 4"2.0'22 1 2°25 2.9' 45°68 4.1' 8" 11 1 4°16 2.5' 3 4"2.0'22 1 2°47 3.6' 45°123 5.0' 12" 11 1 4°32 3.2' 3 4" 2.0' 22 1 2°88 4.5'3.0' 45°232 6.1'2.5' 16" 11 1 4°70 4.1'1"3.0' 22 1 2°184 5.7' 1 1 8"4.0' 45°478 7.8' 20" 11 1 4°91 4.5' 1 1 4" 3.0' 22 1 2°225 6.1' 4.0' 45°560 8.2' 24" 11 1 4°128 5.0'1 1 4"3.5' 22 1 2°320 6.8' 1 3 8"4.5' 45°820 9.4' * D = ANCHOR ROD DIAMETER 45° BEND L L A A A A L L 11 1 4° AND 22 1 2 ° BENDS PIPE CLAMP AND ANCHOR ROD PIPE CLAMP AND ANCHOR ROD PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator CONCRETE BLOCKING FOR VERTICAL FITTINGS STD. PLAN - 330.2 6/28/2023 NOTES: 1.NO CHANGE IN PIPE DIRECTION OR DIAMETER SHALL OCCUR WITHIN 36' OF THE VERTICAL BEND. BENDS, TEES, REDUCERS, ETC. BEYOND THE 36' LIMIT MAY BE RESTRAINED BY STANDARD CONCRETE BLOCKING PER STD PLANS 330.1 AND 330.2. 2.FITTINGS SHALL BE POLYWRAPPED AFTER INSTALLATION OF PIPE CLAMPS AND ANCHOR RODS PRIOR TO POURING CONCRETE BLOCKING. 3.PIPE CLAMPS AND ANCHOR RODS SHALL BE INSTALLED PER STD PLAN 330.4. 4.JOINT RESTRAINT SHALL BE MEGALUG SERIES 1100 OR EQUAL. 5.WATER MAIN SHALL NOT BE PRESSURIZED UNTIL ALL TRENCHING WITHIN 100' OF VERTICAL BEND IS BACKFILLED AND COMPACTED TO MINIMUM 3' COVER. 6.90° VERTICAL BENDS SHALL ONLY BE INSTALLED WHERE GIVEN PRIOR APPROVAL BY THE CITY. 7.ALL CONCRETE SHALL BE MECHANICALLY MIXED. JOB SITE MIXING, HAND-MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. 8.BACKFILL TRENCH BEYOND 90° VERTICAL BLOCK WITH CRUSHED SURFACING TOP COURSE MATERIAL COMPACTED TO 95% MDD. CRUSHED BACKFILL SHALL EXTEND 20' BEYOND BLOCK OR TO FIRM BEARING TRENCH WALL, WHICHEVER IS LESS. 9.CONCRETE BLOCKING SHALL BE LEFT OPEN OR SHEETED FOR MINIMUM 24 HOURS. MINIMUM DIMENSIONS PIPE SIZE BEND VOLUME (CF)A D *L 4" 11 1 4° BLOCKING NOT REQUIRED22 1 2° 45° 90°16 2.5'3 4"2.0' 6" 11 1 4° BLOCKING NOT REQUIRED 22 1 2° 45°13 2.3'3 4"2.0' 90°43 3.5'3 4"2.0' 8" 11 1 4° BLOCKING NOT REQUIRED 22 1 2° 45°33 3.2'3 4"2.0' 90°86 4.4'3 4"2.0' 10" 11 1 4°BLOCKING NOT REQUIRED 22 1 2°13 2.3'3 4"2.0' 45°64 4.0'3 4"2.0' 90°141 5.2'1"3.5' 12" 11 1 4°BLOCKING NOT REQUIRED 22 1 2°20 2.7'3 4"2.0' 45°111 4.8'3 4"2.0' 90°206 5.9'1 1 8"4.0' * D = ANCHOR ROD DIAMETER MINIMUM DIMENSIONS BASED ON FOLLOWING CONDITIONS: • PIPE RESTRAINED MINIMUM 36' ON EACH SIDE OF BEND • SAFE BEARING LOAD = 1,000 SF • CONCRETE STRENGTH = 3,000 PSI • CONCRETE WEIGHT = 150 PCF • HYDROSTATIC PRESSURE = 200 PSI • TRENCH = TYPE 2 FLAT BOTTOM TRENCH WITH LIGHTLY CONSOLIDATED BACKFILL PER ANSI/AWWA C150/A21.50 • FACTOR OF SAFETY = 1.5 • SOIL FRICTIONAL RESISTANCE BASED ON COHESIVE GRANULAR SOIL (GC+SC), SAND, GRAVEL, CLAY MIXTURE CONCRETE BLOCKING DESIGN MUST BE ADJUSTED FOR VARIANCES IN ANY OF THESE CONDITIONS. 45° BEND L L A A A A L L 11 1 4° AND 22 1 2 ° BENDS PIPE CLAMP AND ANCHOR ROD PIPE CLAMP AND ANCHOR ROD A A L L 90° BEND PIPE CLAMP AND ANCHOR ROD PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator CONCRETE BLOCKING FOR VERTICAL FITTINGS WITH RESTRAINED JOINTS STD. PLAN - 330.3 6/28/2023 WATER MAIN PIPE CLAMP HEAVY DUTY HOT-DIPPED GALVANIZED PIPE CLAMP, COOPER B-LINE B3132 OR EQUAL, WITH OPENINGS TO ACCOMMODATE ANCHOR ROD DIAMETER ANCHOR ROD ALL-THREAD ROD, ASTM A242 CORTEN OR STAINLESS STEEL, SIZE PER STD PLAN 330.2 AND STD PLAN 330.3 NUT HEAVY HEX NUT, ASTM A563 GRADE C3 OR STAINLESS STEEL 316SS, SIZE TO MATCH ANCHOR ROD DIAMETER, TIGHTEN TOP NUTS TO TENSION BOLTS AND LOWER NUTS TO COMPRESS CLAMP SNUG WASHER ROUND FLAT STRUCTURAL WASHER, CORTEN OR STAINLESS STEEL 316SS, SIZE TO MATCH ANCHOR ROD DIAMETER A MATERIALS B C D A B C D PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator CONCRETE BLOCKING PIPE CLAMP AND ANCHOR RODS STD. PLAN - 330.4 6/28/2023 NOTES: 1.SHACKLE RODS SHALL BE USED AS A JOINT RESTRAINT SYSTEM WHERE INDICATED IN THE PLANS OR SPECIFICATIONS OR WHERE OTHERWISE REQUIRED BY THE ENGINEER. 2.INSTALL THE JOINT RESTRAINT SYSTEM IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS TO ENSURE ALL JOINTS ARE MECHANICALLY LOCKED TOGETHER. 3.EYE BOLTS SHALL BE INSTALLED TO PULL AGAINST THE MJ BODY AND NOT THE MJ FOLLOWER. TORQUE NUTS AT 75-90 FT-LB. 4.INSTALL RODS AT EQUAL THREAD DEPTH INTO COUPLING NUTS. ARRANGE RODS SYMMETRICALLY AROUND THE PIPE. 5.WHERE A MJ VALVE OR FITTING IS SUPPLIED WITH SLOTS FOR "T" BOLTS INSTEAD OF HOLES, AN ADAPTER (FLXMJ) SHALL BE USED TO PROVIDE ADEQUATE SPACE FOR TIE BOLT INSTALLATION. 6.NO RUN OF RESTRAINED PIPE SHALL BE GREATER THAN 60' IN LENGTH BETWEEN FITTINGS. INSTALL LONG BODY SLEEVES WHERE A CONTINUOUS RUN OF PIPE GREATER THAN 60' IS REQUIRED TO BE RESTRAINED. 7.CONTINUOUSLY RESTRAINED RUNS SHALL USE MJ PIPE WITH EYE BOLTS INSTALLED AS ROD GUIDES AT EACH JOINT. ROD 3/4" ALL-THREAD ROD, ASTM A242 CORTEN OR STAINLESS STEEL, SIZE AS FOLLOWS: MAIN DIAMETER NUMBER OF RODS 4", 6"2 8", 10", 12"4 16", 18"8 20"10 EYE BOLT 3/4" 90° EYE BOLT, CORTEN, WITH EYE TO ACCOMMODATE 3/4" ROD, ROMAC OR EQUAL COUPLING NUT 3/4" FULL HEX COUPLING NUT WITH CENTER STOP, ASTM A563 GRADE OR STAINLESS STEEL WASHER 3/4" ROUND FLAT STRUCTURAL WASHER, CORTEN OR STAINLESS STEEL 316SS NUT 3/4" HEAVY HEX NUT, ASTM A563 GRADE C3 OR STAINLESS STEEL 316SS A MATERIALS B C D E MAX 60' CA D EB PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator SHACKLE ROD JOINT RESTRAINT SYSTEM STD. PLAN - 330.5 6/28/2023 NOTES: 1.NEW WATER MAIN SHALL BE CLASS 52 DI PIPE WITH 8-MIL POLYETHYLENE ENCASEMENT AROUND PIPE AND TRANSITION COUPLINGS IN ACCORDANCE WITH AWWA C105. 2.NEW WATER MAIN SHALL BE SUPPORTED BY FIRM BEARING EARTH. INSTALL CONCRETE BLOCKS (8"x16"x2") UNDER NEW WATER MAIN AS REQUIRED OR SHORE TRENCH WALL UNDER WATER MAIN AS SHOWN. 3.ALL COUPLERS SHALL BE LONG BARREL TRANSITION COUPLERS. 4.AC PIPE SHALL BE CUT WITH A HAND-OPERATED CARBIDE BLADE CUTTER WITH CONTROLLED FLOWING WATER. 5.AC PIPE SEGMENTS SHALL BE FILLED WITH CDF AND LEFT TO BE BURIED IN THE TRENCH. 6.CONTAMINATED CLOTHING SHALL BE LEFT AND BURIED IN TRENCH, OR TRANSPORTED IN SEALED IMPERMEABLE BAGS AND LABELED IN ACCORDANCE WITH WAC 296-62-07721. 7.ALL WORK ON AC PIPE SHALL BE PERFORMED BY A LICENSED ASBESTOS ABATEMENT CONTRACTOR. 8.THE CONTRACTOR IS REQUIRED TO MAINTAIN WORKERS' EXPOSURE TO ASBESTOS MATERIAL AT OR BELOW THE LIMIT PRESCRIBED IN WAC 296-62-07705. NEW UTILITY PIPE BACKFILL TRENCH SHORING (SEE NOTE 2) EXISTING AC WATER MAIN ROMAC 501 COUPLING ADAPTOR CONCRETE SUPPORT BLOCKS (SEE NOTE 2) NEW DI WATER MAIN 12" MIN 3' MIN 6" MIN 3'3'TRENCH WIDTH ALL WORK ON EXISTING WATER MAIN SHALL BE PERFORMED BY CITY OF RENTON FORCES PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator ASBESTOS CEMENT WATER MAIN REPLACEMENT AT NEW UTILITY CROSSING STD. PLAN - 330.6 6/28/2023 VALVE OPERATING NUT EXTENSION VALVE MARKER POST SECTION A-A AA VALVE BOX AND LID NOTES: 1.EXTENSIONS ARE REQUIRED WHEN VALVE NUT IS MORE THAN 3' BELOW FINISHED GRADE. EXTENSIONS ARE TO BE A MINIMUM OF 1' LONG. ONLY ONE EXTENSION TO BE USED PER VALVE. 2.ALL EXTENSIONS ARE TO BE MADE OF STEEL, SIZED AS NOTED, WITH ANTICORROSION COATING CONFORMING TO AWWA C210 NOTES: 1.VALVE MARKER POST TO BE USED FOR ALL MAIN LINE VALVES OUTSIDE PAVED AREAS. 2.DISTANCE TO VALVE SHALL BE NEATLY STENCILED ON THE POST WITH 2" NUMERALS. MAIN 3" MIN VALVE BOX TWO-PIECE VALVE BOX WITH REGULAR BASE SECTION TO FIT AND STANDARD 8" TOP SECTION, OLYMPIC FOUNDRY INC 940 OR RICH #045 (NON-LOCKING) VALVE BOX LID COVER TO MATCH VALVE BOX MANUFACTURER, TO READ "WATER", WITH EARS IN DIRECTION OF WATER MAIN HMA COLLAR 8" THICK HMA FOR VALVE IN PAVED AREA OR 3'x3'x6" CONCRETE PAD IN UNPAVED AREA OPERATING NUT EXTENSION SEE DETAIL, THIS SHEET MARKER POST WHITE MARKER POST WITH ANCHOR BARB AND BLUE LABEL TO READ "WATER", CARSONITE UTILITY MARKER CRM3-066-08 OR EQUAL A B C D E MATERIALS 3 3 4" 62" 34" 24" 12" 8" TO 12" 2" SQUARE OPERATING NUT 4 1 4" DIAMETER 1 8" MIN THICKNESS 1" DIAMETER STEEL, LENGTH AS REQUIRED 1 8" MIN THICKNESS 2 1 4" INSIDE MEASUREMENT 2 1 4" DEPTH D A C B E PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator VALVE BOX, OPERATING NUT EXTENSION, AND MARKER POST STD. PLAN - 330.7 6/28/2023 PLAN PROFILE TEE MAIN LINE TEE WITH 4" SIDE OUTLET (MJxFL) WITH PLUG (MJ) GATE VALVE 4" GATE VALVE WITH 2" SQUARE OPERATING NUT AND VALVE OPERATING NUT EXTENSION AS REQUIRED PER STD PLAN 330.1 VALVE BOX AND LID VALVE BOX AND LID PER STD PLAN 330.8 FLANGE 4"x2" TAPPED FLANGE (FLxFIPT) PIPE 2" BRASS OR BRONZE NIPPLE, LENGTH TO FIT BEND 2" 90° BRASS BEND (FIPT x PACK JOINT), FORD C14-77-Q-NL OR EQUAL ADAPTER 2"x2 1 2" BRASS ADAPTER (FIPTxMNST) CAP 2 1 2" CAP (FNST) WITH GASKET, NOT VENTED METER BOX AND LID METER BOX, ARMORCAST A6001640PCX18, WITH METER BOX LID, ARMORCAST A6001947RCI-H7, TO READ "RENTON WATER", EXPANSION JOINTS MUST BE INSTALLED 12" MINIMUM ON BOTH SIDES OF METER BOX BLOCKING CONCRETE BLOCKING PER STD PLAN 330.1 FINISHED GRADE MAIN A C DB F E 6" E G I I A B D H 4" TO 6" H A B C D E F G H I J J J MATERIALS PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 2" BLOW-OFF ASSEMBLY (PERMANENT) STD. PLAN - 340.1 6/28/2023 A PLUG OR CAP MAIN LINE PLUG OR CAP WITH 2" TAP (FIPT) PIPE 2" CLOSE NIPPLE BEND 2" 90° BRASS BEND (FIPTxFIPT) PIPE 2" BRASS OR BRONZE NIPPLE, LENGTH TO FIT GATE VALVE 2" GATE VALVE (FIPTxFIPT) WITH SQUARE OPERATING NUT AND VALVE OPERATING NUT EXTENSION AS REQUIRED PER STD PLAN 330.1 VALVE BOX AND LID VALVE BOX AND LID PER STD PLAN 330.8 BLOCKING CONCRETE DEAD MAN BLOCKING WITH SHACKLE RODS TO CAP, BLOCK SHALL BE POURED AGAINST UNDISTURBED EARTH, SIZE OF BLOCK TO BE DETERMINED BASED ON TEST PRESSURE OF WATER LINE AND SOIL CHARACTERISTICS. D B C E F G PROFILE PLAN WATER MAIN C D A B C D E E F C D D D C C G 18" MATERIALS PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 2" BLOW-OFF ASSEMBLY (TEMPORARY) STD. PLAN - 340.2 6/28/2023 CORPORATION STOP 1" BALLCORP WITH AWWA TAPERED (CC) INLET AND COPPER THREAD OUTLET, FORD FB600-4-NL OR EQUAL SWING JOINT 1" BRASS SWING JOINT PIPE 1" TYPE "K" SOFT COPPER TUBING COUPLING 1" STRAIGHT COUPLING (MIPT x PACK JOINT), FORD C84-44, MUELLER H15428, OR EQUAL GATE VALVE 1" BRONZE GATE VALVE, THREADED, RED-WHITE VALVE NO. 280, OHIO BRASS NO. 2500, OR EQUAL UNION 1" BRASS UNION PIPE 1" BRASS NIPPLE AIR & VACUUM RELEASE VALVE ASSEMBLY 1" AIR AND VACUUM RELEASE VALVE ASSEMBLY, APCO NO. 143-C, VAL-MATIC NO. 201-C, OR CRISPIN UL10, OR EQUAL PIPE 1" GALVANIZED IRON NIPPLE BEND 1" 90° GALVANIZED IRON BEND UNION 1" GALVANIZED IRON UNION PIPE 1" GALVANIZED IRON PIPE, LENGTH TO FIT SWING JOINT (1) 2"X1" BELL REDUCER (2) 2" 90° STREET ELLS PIPE 2" GALVANIZED IRON PIPE, LENGTH TO FIT, FIELD LOCATE BEND 2" 180° RETURN BEND, OPEN PATTERN STRAINER 2" BEEHIVE STRAINER METER BOX AND LID METER BOX, ARMORCAST A6001946PCX18, WITH METER BOX LID, ARMORCAST A6001969RCI-H7, TO READ "RENTON WATER" GRAVEL 1 1 4" WASHED GRAVEL A B C D E F G H I J K L M N O P Q R 12" MIN A B C D E F G B G H I J K L M N O P Q 6" MIN 5" TO 18" NOTES: 1.AIR AND VACUUM RELEASE VALVE ASSEMBLY MUST BE INSTALLED AT THE HIGHEST POINT IN THE WATER MAIN. IF THE HIGH POINT FALLS IN A LOCATION WHERE THE ASSEMBLY CANNOT BE INSTALLED, PROVIDE ADDITIONAL DEPTH OF MAIN TO CREATE THE HIGH POINT AT A LOCATION WHERE THE ASSEMBLY CAN BE INSTALLED. 2.LOCATE METER BOX OUTSIDE OF TRAFFIC AREAS, BEHIND THE CURB. MAIN R MATERIALS FINISHED GRADE PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 1" AIR AND VACUUM RELEASE VALVE ASSEMBLY STD. PLAN - 340.3 6/28/2023 PRESSURE REDUCING VALVE ASSEMBLY PRV ASSEMBLY WITH INTERNAL BYPASS AND STRAINER, ZURN WILKINS 600XL SERIES OR EQUAL (FNPT) PIPE BRASS NIPPLE (MNPT), LENGTH TO FIT SHUTOFF VALVE BRONZE BALL VALVE, ZURN WILKINS 850XL SERIES OR EQUAL (FNPT) BEND 90° BRASS BEND (FNPT x PACK JOINT) PIPE TYPE "K" SOFT COPPER TUBING, LENGTH TO FIT BEND 90° BRASS BEND (PACK JOINT x PACK JOINT) BOX AND LID 13"x24" BOX AND LID, CONCRETE POLYMER OR HDPE GRAVEL 1 1 4" WASHED GRAVEL PVC PIPE PVC NIPPLE, LENGTH TO FIT NOTE: 1.WHERE THE PRV ASSEMBLY IS INSTALLED ON AN EXISTING SERVICE, THE EXISTING SERVICE SHALL BE CUT AND NEW COPPER TUBING AND BRASS FITTINGS SHALL BE INSTALLED AS REQUIRED. SERVICE FROM METER SERVICE TO BUILDING 3" MIN 3" MIN 6" TO 9" 6" MINH 3" MIN D A I G A B C D E F G H MATERIALS FINISHED GRADE 21" TO 30" C B E F D B E F I PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator INDIVIDUAL PRESSURE REDUCING VALVE ASSEMBLY (RESIDENTIAL) STD. PLAN - 340.4 6/28/2023 INSIDE HOUSE PREFERRED CONFIGURATION 2 3 10 8 10 4 2 FLOW ADJACENT TO WATER METER PROPERTY LINE SAWDUST 5 6 9 5 FILL 7 24" MIN 7 7 6" FROM 6,• P A TYP V L WATER METER 1 10 3 10 8 10 4 OFLOW 2 OUTSIDE FOUNDATION 5 6 9 5 SAWDUST FILL 24"MIN: - 6" 6•• ffPEA(TGRAVEL2 10 FLOW FOR 3/4" AND 1" SERVICE (3/4" SHOWN) # ITEM AMT 1 90' GALVANIZED STEEL ELBOW 4 EA. 2 3/4" PACKING JOINT COUPLING W/MALE IRON PIPE 2 EA. THREAD FOR COPPER PIPE SERVICE: FORD C84-33 OR EQUIVALENT FOR GALVANIZED PIPE SERVICE:FORD C85-33 OR EQUIVALENT 3 PRESSURE REDUCING VALVE W/STRAINER - 3/4" 1 EA. WITH UNION COUPLINGS AT INLET AND OUTLET, WILKINS 600 SERIES OR EQUAL (WITH INTERNAL BYPASS AND STRAINER) 4 3/4" CLOSE UNION - BRASS (M X F) 1 EA. 5 3/4" BRASS VALVE VARIABLE 6 12" STANDARD METER BOX W/SOLID COVER 1 EA. CONCRETE: 17 1/4 X 28 5/8 INSIDE DIMENSIONS, EQUAL TO FOG TITE METER SEAL CO. +2 PLASTIC: 13 X 24 1 INSIDE DIMENSIONS, EQUAL TO BROOKS METER BOX 7 3/4" GALVANIZED STEEL PIPE, THREADED, LENGTH AS VARIABLE REQUIRED 8 3/4" X 1/4" X 3/4" STD. BRASS TEE 1 EA. 9 1/4" PETCOCK (M X F) 1 EA. 10 3/4" BRASS NIPPLE VARIABLE FUNCTION THE FUNCTION OF A PRESSURE REDUCING VALVE IS TO REDUCE HIGH-WATER PRESSURES IN THE SERVICE CONNECTION TO AN ACCEPTABLE RANGE OF 55 TO 75 PSI INSTALLATION OF A PRESSURE REDUCING VALVE IS REQUIRED WHERE THE SERVICE CONNECTION PRESSURE EXCEEDS 80 POUNDS PER SQUARE INCH IN ACCORDANCE TO THE UNIFORM PLUMBING CODE. INSTALLATION THE PRESSURE REDUCING VALVE SHALL BE LOCATED ON THE CUSTOMERS PROPERTY 'DOWNSTREAM" OF THE METER BOX. RESPONSIBILITY FOR PROPER INSTALLATION, OPERATION, AND MAINTENANCE OF THE VALVE SHALL BE ASSUMED BY THE CUSTOMER. THREE POSSIBLE CONFIGURATIONS FOR INSTALLATION OF THE VALVE ARE SHOWN ABOVE. A BUILDING DEPARTMENT PLUMBING PERMIT IS REQUIRED PRIOR TO INSTALLATION Y � STD. PLAN — 340.5 + at + PUBLIC WORKS 3/n" & 1" INDIVIDUAL PRESSURE REDUCING DEPARTMENT VALVE ASSEMBLY N,yp MARCH 2010 FLOW DUCTILE IRON PIPE (FL x PE)13 UTILITY VAULT CO. VAULT FLOW 36" MIN. LENGTH OR APPROVED EQUAL I � �-- 24" MIN. ��n /-- THRUST BLOCK (TYP.) R� 4" THICK CONCRETE J SPLASH BLOCK THRUST RESTRAINT COLLAR FOR - IN-LINE PRV OPTION. SEE DETAIL. III=I II_ , (s� UNDISTURBED SOIL 11 INSTALL NON -SHRINK EPDXY GROUT PRV VAULT - PLAN VIEW BEEHIVE STRAINER PREV SIZE 13 UTILITY VAULT CO. VAULT TEE 2>, 11 OR APPROVED EQUAL PRESSURE 12" UTILITY VAULT CO. t3 UTILITY VAULT CO. VAULT OR APPROVED EQUAL (IN) PREV SIZE (FLxFLxFL) VALVE (FLxFL) ® (FL x PE) BEND SIZE (IN) RELIEF VALVE VAULT MODEL NO. VAULT COVER (QTY) LET PIPE GALVANIZED (IN) 36" FOR PIPES FLANGED COUPLING LENGTH (IN) 11 12 9 STEEL (OR APPROVED EQUAL) ® MODEL n0. (OR SIZE (IN) 10" & ADAPTOR SIZE (IN) 11 LADDER APPROVED EQUAL) SMALLER, 48" (7 6 1@ 13 FOR PIPES 12 6 6 1-1/2 6.4 6 T 2 9 5 1-1/2 (SE) 5106—LA & LARGER FLOW 8 2 8x4 8 24 2 (SE) 2 (SE) 12" MIND 6" -OS' PRV VAULT - ELEVATION NOTE: SUBMERSIBLE PUMP 12VDC WARREN-RUPP SPA 1-1/2 E WHERE STROM DRAIN IS ABOVE FLOOR ELEVATION OF PRV VAULT. PLAN FOR ELECTRICAL CONDUIT SHALL BE SUBMITTED FOR SPECIFIC USAGE. THRUST RESTRAINT COLLAR FOR IN-LINE PRV OPTION. SEE DETAIL ADJUSTABLE STEEL PIPE SUPPORT, STANCHIONS BOLTED TO FLOOR. CONNECTION TO STORM PIPE WITH CATCH BASIN OR MANHOLE PRV VAULT - SECTION INLET & PREV SIZE AUZILLARY TEE ISOLATION GATE D.I. PIPE CL 52 GATE VALVE, UNION, TEE & PRESSURE UILITY VAULT CO. UTILITY VAULT CO. OUT— (IN) PREV SIZE (FLxFLxFL) VALVE (FLxFL) ® (FL x PE) BEND SIZE (IN) RELIEF VALVE VAULT MODEL NO. VAULT COVER (QTY) LET PIPE (IN) SIZE (IN) FLANGED COUPLING LENGTH (IN) SIZE (IN) (OR APPROVED EQUAL) ® MODEL n0. (OR SIZE (IN) ADAPTOR SIZE (IN) APPROVED EQUAL) T 1@ 13 t4 6 6 1-1/2 6.4 6 36 1-1/2 (SE) 1-1/2 (SE) 5106—LA 3-332P 8 8 2 8x4 8 24 2 (SE) 2 (SE) 5106—LA 3-332P 10 10 2-1/2 10x6 10 24 2-1/2 (SE) 2-1/2 (SE) 612LA3-332P 12 j 12 3 12x6 12 1 16 1 3 (SE) 3 (SE) 612—LA 3-332P 14 1 4 4 14x4 14 1 24 1 4 ND U ION 4 (FL) 814—LA 3-332P i6 1 16 4 16.4 18 1 18 4 (NO U ION) 4 (FL) 814—LA 3-332P + ZY e� �+ PUBLIC WORKS PRESSURE REDUCING STATION STD. PLAN — 340.6 �O DEPARTMENT IN—VAULT STANDARD N,yp MARCH 2010 SPLASH BLOCK 90' BEND WITH THRUST BLOCK ISOLATION VALVE FLOW — TEE WITH THRUST BLOCK _/ SPLASI THRUST RESTRAINT COLLAR FLOW — WATER MAII PRV STATION SEE DETAIL SHEET 2' MIN. I 'i 4' MIN LIN—LINE ZONE VALVE (NORMALLY CLOSED) 90' BEND WITH THRUST BLOCK 2' MIN, ISOLATION VALVE STANDARD PRV STATION SITE PLAN FLANGE FOR FUTURE BY—PASS (MJxMJxFL) — FLOW TEE WITH THRUST BLOCK )IHIIVIN JCC ULIHIL ZIMLLI TRUST RESTRAINT COLLAR PRV STATION SITE PLAN IN-LINE OPTION GENERAL NOTES 1. The concrete vault shall be either a precast vault made by Utility Vault Co. or equal as specified in the Standard Details, or shall be cast—in—place with 8" walls and slabs. All joints shall be sealed so vault will remain watertight. 2. The vault cover shall be three 3' x 3' spring loaded hinged steel plate, lockable doors with recessed lift handles, as made by Utility Vault Co. or approved equal. 3. Pipe supports shall be adjustable steel pipe support Stanchions bolted to floor of vault. 4. The vault shall contain one ladder constructed of galvanized steel. A detail plan of location and construction shall be submitted to City prior to installation. 5. The exterior of the vault shall be sealed with two coats of ATCO Bitumastic No. 2221 6. The interior walls and ceiling of the vault shall be painted with two coats of Koppers Ramuc Utility Enamel Flat, or approved equal. The floor shall not be painted. 7. The piping and equipment in the vault shall be given a complete field coat of Inertol Rust Penetrating Primer No. 621 or approved equal. Two finish coats of Torex 800 Enamel, or approved equal, shall be applied over the field coated primer. 8. The Standard PRV Station Site Plan shall be used for all new PRV station construction except when limited right—of—way or existing buildings are restrictive. In such cases, and with City approval, the in—line option may be used. 9. All isolation and zone valves outside the PRV station shall be provided with a valve box when valves are 10" in size or smaller or a valve chamber when valves are 12" in size or larger. 10. Pressure gauges shall be provided on both inlet and outlet pipes in the PRV vault. Secondary gauges shall be mounted on the ceiling in easy view to be read from outside the vault. Gauges shall read from 0-300 psi. Gauge installation shall include petcock between pipe and gauge. 11. Joints on all valves and fittings outside the vault shall be mechanical joints unless otherwise specified. Joints on valves and fittings inside vault shall be flanged or screwed as specified. 12. Vault drain shall be piped to the nearest storm drain sewer or open drainage ditch in lieu thereof. If no storm drain or drainage ditch is available, vault shall be constructed with a sump on the outlet side of the vault. A sump pump shall be installed and the discharge from the pump released onto a concrete pad outside the vault. 13. Cut 3" thick x 5" wide ethafoam 220 or equal to a length necessary to fit the size of pipe installed and compressed into place. The contractor shall make sure the foam is compacted tightly between pipe and vault wall with no voids. Lightly grout interior around pipe. 14. Pipe extending through vault shall be ductile iron, class 53, cement lined FLOW Y � STD. PLAN - 340.7 + y . PUBLIC WORKS PRESSURE REDUCING STATION DEPARTMENT IN -VAULT WITH IN-LINE VALVE ,�p I MARCH 2010 f TO MF r' L_ f-'\ I N BOXES u V11114. r r«E- DRAINING GRAVEL NOTES: 1. ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE DCVA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE DCVA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE DCVA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS—CONNECTION CONTROL SPECIALIST, FAX NO. 425-430-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. Y s4" TO 2" DOUBLE CHECK VALVE STD. PLAN — 340.8 + n + PUBLIC WORKS ASSEMBLY FOR IRRIGATION OR 1 oI DEPARTMENT RESIDENTIAL FIRE SPRINKLER MARCH 2010 ELEVATION PLAN H A I IF A G 24" MIN 6" MIN 6" MIN 12" MIN B G F C C D D E E 12" MIN J PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator STD. PLAN - 350.1 Sht. 1 of 23" TO 10" DCVA VAULT INSTALLATION DOMESTIC AND IRRIGATION SERVICES 6/28/2023 MATERIALS NOTES: 1.THE DCVA MUST BE LISTED ON THE LATEST VERSION OF "BACKFLOW ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY THE STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2.THE DCVA MUST BE TESTED BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER. ASSEMBLY TO BE MAINTAINED BY PROPERTY OWNER. A COPY OF THE TEST REPORT SHALL BE SENT TO THE CITY OF RENTON WATER UTILITY CROSS CONNECTION CONTROL SPECIALIST, FAX 425-430-7207, EMAIL BACKFLOW@RENTONWA.GOV. 3.VAULTS SHALL NOT BE INSTALLED IN AREAS WITH VEHICLE TRAFFIC. 4.VAULT AND HATCH MODELS ARE PROVIDED AS REFERENCE. SHOP DRAWINGS SHALL BE SUBMITTED TO THE CITY FOR APPROVAL. 5.TEE AND GATE VALVE REQUIRED ON MAIN. 6.PROVIDE MINIMUM 2' OF LEVEL, UNOBSTRUCTED AREA AROUND HATCHES. 7.EACH VALVE SHALL BE MARKED WITH MODEL NUMBER WITH DESIGNATION OF RESILIENT SEAT: SUCH AS "RS" OR "R", WHICH MUST BE CAST, MOLDED, OR AFFIXED ONTO THE BODY OR BONNET OF THE VALVE. ALL FERROUS BODIED VALVES SHALL BE COATED WITH A MINIMUM OF 4 MILS OF EPOXY OR EQUIVALENT POLYMERIZED COATING. A VAULT MODEL NUMBERS DCVA SIZE VAULT BASE PIECE CENTER PIECE TOP PIECE ACCESS HATCH 3"644-LA NO. 644-B N/A NO. 64-352P HHD-1C 4"575-LA NO. 575-BL N/A NO. 57-2-33F HHD-1C 6"577-LA NO. 588-BL N/A NO. 57-2-33F HHD-1C 8"4484-LA NO. 4484-BL NO. 4484-ML NO. 4484-TL-2-332P HHD-2D 10"5106-LA NO. 5106-BL NO. 5106-ML NO. 5106-TL3-332 HHD-2D DOUBLE CHECK VALVE ASSEMBLY LINE-SIZED WASHINGTON STATE-APPROVED DCVA WITH TWO (2) RESILIENT-SEATED SHUT-OFF VALVES AND FOUR (4) RESILIENT-SEATED TEST COCKS, DCVA SHALL BE INSTALLED EQUIDISTANT FROM THE ENDS OF THE CONCRETE VAULT, TWO (2) VALVE SUPERVISORY SWITCHES (ONE PER VALVE) PER RRFA REQUIREMENTS PIPE SUPPORT ADJUSTABLE PIPE SADDLE SUPPORT, GRINNELL FIG 264 OR EQUAL, WITH BASE, BOLTED TO FLOOR ADAPTER RESTRAINED FLANGE ADAPTER, EBAA IRON SERIES 2100 MEGAFLANGE OR EQUAL WATER MAIN CLASS 53 DI PIPE (PExFL) WITH RESTRAINED JOINTS WALL FLANGE MIDSPAN PIPE RESTRAINT WITH CONCRETE BLOCKING PER STD PLAN 370.4, SEAL PIPE PENETRATIONS WITH WATER-TIGHT GROUT CONCRETE VAULT OLDCASTLE PRECAST VAULT, MODEL NUMBERS PER TABLE ABOVE, OR EQUAL DRAIN MINIMUM 6" PVC FLOOR DRAIN, SLOPE TO STORM DRAIN OR DAYLIGHT TO DRAINAGE DITCH WITH WIRE MESH RODENT SCREEN AT DRAIN OUTLET, SEAL PIPE PENETRATION WITH WATER-TIGHT GROUT ACCESS HATCH TWO LOCKING HINGED ALUMINUM DOORS, TRAFFIC-RATED, WITH SLIP-RESISTANT TREATMENT, MARKED "WATER", LW PRODUCTS MODEL NUMBERS PER TABLE BELOW, OR EQUAL LADDER GALVANIZED STEEL LADDER SECURED TO VAULT PER STD PLAN 370.5 GRAVEL FOUNDATION GRAVEL PER WSDOT STANDARD SPECIFICATIONS, 12" MINIMUM ALL DIRECTIONS B C D E F G I H J PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 3" TO 10" DCVA VAULT INSTALLATION DOMESTIC AND IRRIGATION SERVICES STD. PLAN - 350.1 Sht. 2 of 2 6/28/2023 NOTES: 1.THE DCVA MUST BE LISTED ON THE LATEST VERSION OF "BACKFLOW ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY THE STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2.THE DCVA MUST BE TESTED BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER. ASSEMBLY TO BE MAINTAINED BY PROPERTY OWNER. A COPY OF THE TEST REPORT SHALL BE SENT TO THE CITY OF RENTON WATER UTILITY CROSS CONNECTION CONTROL SPECIALIST, FAX 425-430-7207, EMAIL BACKFLOW@RENTONWA.GOV. 3.TEE AND GATE VALVE REQUIRED ON MAIN. 4.PROTECT AGAINST FREEZING OR DAMAGE. USE HEAT-TAPE IF AREA IS SUBJECT TO FREEZING. 5.DCVA INSTALLATIONS THAT DIFFER FROM THE STANDARD PLAN MUST BE APPROVED BY THE CITY OF RENTON WATER UTILITY AND WILL BE REVIEWED ON A CASE-BY-CASE BASIS TO ENSURE THEY MEET CURRENT MINIMUM REQUIREMENTS FOR INSTALLATION AND FREEZE PROTECTION. 6.EACH VALVE SHALL BE MARKED WITH MODEL NUMBER AND DESIGNATION OF RESILIENT SEAT, SUCH AS "RS" OR "R", WHICH MUST BE CAST, MOLDED, OR AFFIXED ONTO THE BODY OR BONNET OF THE VALVE. ALL FERROUS-BODIED VALVES SHALL BE COATED WITH A MINIMUM OF 4 MILS EPOXY OR EQUIVALENT POLYMERIZED COATING. 7.INTERIOR WATER APPURTENANCES MUST CONFORM TO UPC REQUIREMENTS. MATERIALS DOUBLE CHECK VALVE ASSEMBLY LINE-SIZED WASHINGTON STATE-APPROVED DCVA, INCLUDES TWO (2) RESILIENT-SEATED SHUT-OFF VALVES AND FOUR (4) RESILIENT-SEATED TEST-COCKS, BRASS PLUGS INSTALLED ON TEST-COCKS PIPE SUPPORT ADJUSTABLE PIPE SADDLE SUPPORT, GRINNELL FIG 264 OR EQUAL, WITH BASE, BOLTED TO FLOOR ADAPTER RESTRAINED FLANGE ADAPTER, EBAA IRON SERIES 2100 MEGAFLANGE OR EQUAL WATER MAIN CLASS 53 DI PIPE (PExFL OR FLxFL) BEND 90° BEND (FLxFL OR FLxMJ WITH RESTRAINED JOINTS) PIPE PENETRATION SEAL PIPE PENETRATION WITH WATER-TIGHT GROUT BLOCKING CONCRETE THRUST BLOCKING PER STD PLAN 330.1 SERVICE FROM METER E G 12" MIN 1' TO 5' A EXTERIOR BUILDING WALL FINISHED FLOOR SERVICE TO BUILDING D E C B F A B C D E F G PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 3" TO 10" DCVA INTERIOR INSTALLATION DOMESTIC AND IRRIGATION SERVICES STD. PLAN - 350.2 6/28/2023 PLAN ELEVATION L J DC B K A J L 6" MIN 6" MIN 12" MIN 24" MIN A E F F I H I H G G 12" MIN 12" MIN M PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 3" TO 10" DCDA VAULT INSTALLATION FIRE SPRINKLER SYSTEMS STD. PLAN - 350.3 Sht. 1 of 2 6/28/2023 MATERIALS NOTES: 1.THE DCDA MUST BE LISTED ON THE LATEST VERSION OF "BACKFLOW ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY THE STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2.THE DCDA MUST BE TESTED BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER. ASSEMBLY TO BE MAINTAINED BY PROPERTY OWNER. A COPY OF THE TEST REPORT SHALL BE SENT TO THE CITY OF RENTON WATER UTILITY CROSS CONNECTION CONTROL SPECIALIST, FAX 425-430-7207, EMAIL BACKFLOW@RENTONWA.GOV. 3.VAULTS SHALL NOT BE INSTALLED IN AREAS WITH VEHICLE TRAFFIC. 4.VAULT AND HATCH MODELS ARE PROVIDED AS REFERENCE. SHOP DRAWINGS SHALL BE SUBMITTED TO THE CITY FOR APPROVAL. 5.TEE AND GATE VALVE REQUIRED ON MAIN. 6.WHEN DCDA IS USED IN THE SAME LINE AS THE DOMESTIC BUILDING METER, THE METERED BYPASS SHALL BE OMITTED. 7.MINIMUM 2' OF LEVEL, UNOBSTRUCTED AREA AROUND HATCHES. 8.FDC TO BE LOCATED DOWNSTREAM OF DCDA. FDC LINE AND CHECK VALVE MAY BE ROUTED INSIDE THE DCDA VAULT PROVIDED THE VAULT IS ADEQUATELY SIZED AND ALL PROVISIONS OF STD PLAN 370.2 ARE MET. 9.LONGER VALVE ASSEMBLIES MAY REQUIRE A LARGER VAULT TO MEET REQUIRED CLEARANCES. SUBMIT FOR APPROVAL. 10.EACH VALVE SHALL BE MARKED WITH MODEL NUMBER WITH DESIGNATION OF RESILIENT SEAT: SUCH AS "RS" OR "R", WHICH MUST BE CAST, MOLDED, OR AFFIXED ONTO THE BODY OR BONNET OF THE VALVE. ALL FERROUS BODIED VALVES SHALL BE COATED WITH A MINIMUM OF 4 MILS OF EPOXY OR EQUIVALENT POLYMERIZED COATING. A VAULT MODEL NUMBERS DCVA SIZE VAULT BASE PIECE CENTER PIECE TOP PIECE ACCESS HATCH 3"675-WA NO. 675-BL NO. 675-MLW NO. 675-TL-2-332P HHD-1C 4"675-WA NO. 675-BL NO. 675-MLW NO. 675-TL-2-332P HHD-1C 6"675-WA NO. 675-BL NO. 675-MLW NO. 675-TL-2-332P HHD-1C 8"687-LA NO. 687-BL NO. 687-ML NO. 687-TL-2-332P HHD-2D 10"5106-LA NO. 5106-BL NO. 5106-ML NO. 5106-TL3-332 HHD-2D DOUBLE CHECK DETECTOR ASSEMBLY LINE-SIZED WASHINGTON STATE-APPROVED DCDA WITH TWO (2) RESILIENT-SEATED SHUT-OFF VALVES AND FOUR (4) RESILIENT-SEATED TEST COCKS, DCDA SHALL BE INSTALLED EQUIDISTANT FROM THE ENDS OF THE CONCRETE VAULT, TWO (2) VALVE SUPERVISORY SWITCHES (ONE PER VALVE) PER RRFA REQUIREMENTS BYPASS 3 4" DETECTOR BYPASS, ALL MATERIALS TO BE BRASS OR COPPER BYPASS METER 3 4" AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BY THE CITY DOUBLE CHECK VALVE ASSEMBLY 3 4" WASHINGTON STATE-APPROVED DCVA WITH TWO (2) RESILIENT-SEATED SHUT-OFF VALVES AND FOUR (4) RESILIENT-SEATED TEST COCKS PIPE SUPPORT ADJUSTABLE PIPE SADDLE SUPPORT, GRINNELL FIG. 264 OR EQUAL, WITH BASE, BOLTED TO FLOOR ADAPTER RESTRAINED FLANGE ADAPTER, EBAA IRON SERIES 2100 MEGAFLANGE OR EQUAL WATER MAIN CLASS 53 DI PIPE (PExFL) WITH RESTRAINED JOINTS WALL FLANGE MIDSPAN PIPE RESTRAINT WITH CONCRETE BLOCKING PER STD PLAN 370.4, SEAL PIPE PENETRATIONS WITH WATER-TIGHT GROUT CONCRETE VAULT OLDCASTLE PRECAST VAULT, MODEL NUMBERS PER TABLE BELOW, OR EQUAL DRAIN MINIMUM 6" PVC FLOOR DRAIN, SLOPE TO STORM DRAIN OR DAYLIGHT TO DRAINAGE DITCH WITH WIRE MESH RODENT SCREEN AT DRAIN OUTLET, SEAL PIPE PENETRATION WITH WATER-TIGHT GROUT ACCESS HATCH TWO LOCKING HINGED ALUMINUM DOORS, TRAFFIC-RATED, WITH SLIP-RESISTANT TREATMENT, MARKED "WATER", LW PRODUCTS MODEL NUMBERS PER TABLE BELOW, OR EQUAL LADDER GALVANIZED STEEL LADDER SECURED TO VAULT PER STD PLAN 370.5 GRAVEL FOUNDATION GRAVEL PER WSDOT STANDARD SPECIFICATIONS, 12" MINIMUM ALL DIRECTIONS B C D E F G H I J K L M PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator STD. PLAN - 350.3 Sht. 2 of 23" TO 10" DCDA VAULT INSTALLATION FIRE SPRINKLER SYSTEMS 6/28/2023 NOTES: 1.THE RPBA MUST BE LISTED ON THE LATEST VERSION OF "BACKFLOW ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY THE STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2.THE RPBA MUST BE TESTED BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER. ASSEMBLY TO BE MAINTAINED BY PROPERTY OWNER. A COPY OF THE TEST REPORT SHALL BE SENT TO THE CITY OF RENTON WATER UTILITY CROSS CONNECTION CONTROL SPECIALIST, FAX 425-430-7207, EMAIL BACKFLOW@RENTONWA.GOV. 3.RPBA AND ENCLOSURE SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. TO OWNER'S ELECTRICAL PANEL 24" MIN 2" 12" MIN SERVICE FROM METER SERVICE TO BUILDING REDUCED PRESSURE BACKFLOW ASSEMBLY LINE-SIZED WASHINGTON STATE-APPROVED RPBA WITH TWO (2) RESILIENT-SEATED SHUT-OFF VALVES AND FOUR (4) RESILIENT-SEATED TEST COCKS. RPBA SHALL BE INSTALLED CENTERED IN THE HEATED ENCLOSURE WITH MINIMUM 3" CLEARANCE IN ALL DIRECTIONS PIPE AND FITTINGS SIZE AND MATERIALS AS REQUIRED PER UPC REQUIREMENTS ELECTRICAL OUTLET 120-VOLT OUTDOOR ELECTRICAL OUTLET WITH COVER, INSTALL HEAT TAPE FOR FREEZE PROTECTION ELECTRICAL CONDUIT RIGID CONDUIT PER ELECTRICAL PERMIT REQUIREMENTS ENCLOSURE INSULATED ENCLOSURE SIZE TO FIT RPBA, ASSE 1060 CERTIFIED, SAFE-T-COVER OR EQUAL DRAIN ENCLOSURE DRAIN SIZED IN ACCORDANCE WITH AWWA CROSS CONNECTION CONTROL MANUAL STANDARDS: ≤1" RPBA = 3" DRAIN, 1 1 2" & 2" RPBA = 4" DRAIN CONCRETE SLAB CONCRETE SLAB SIZED TO FIT RPBA AND ENCLOSURE PER MANUFACTURER BOLTS 3/8"X4" ANCHOR BOLTS PER MANUFACTURER GRAVEL 1 1 4" WASHED GRAVEL 4" MIN FINISHED GRADE A C B D E F G IPROPERTY LINEA MATERIALS B C D E F G H I 6" MIN H PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 3/4" TO 2" RPBA HEATED ENCLOSURE INSTALLATION DOMESTIC AND IRRIGATION SERVICES STD. PLAN - 360.1 6/28/2023 REDUCED PRESSURE BACKFLOW ASSEMBLY LINE-SIZED WASHINGTON STATE-APPROVED RPBA WITH TWO (2) RESILIENT-SEATED SHUT-OFF VALVES AND FOUR (4) RESILIENT-SEATED TEST COCKS. RPBA SHALL BE INSTALLED CENTERED IN THE HEATED ENCLOSURE WITH MINIMUM 3" CLEARANCE TO ALL SIDES AND MINIMUM 3" CLEARANCE TO CEILING WHEN VALVES ARE FULLY OPEN PIPE SUPPORT ADJUSTABLE PIPE SADDLE SUPPORT, GRINNELL FIG 264 OR EQUAL, WITH BASE, BOLTED TO FLOOR ADAPTER RESTRAINED FLANGE ADAPTER, EBAA IRON SERIES 2100 MEGAFLANGE OR EQUAL WATER MAIN CLASS 53 DI PIPE (PExFL OR FLxFL) BEND 90° BEND (FLxFL OR FLxMJ WITH RESTRAINED JOINTS) PIPE PENETRATION SEAL PIPE PENETRATION WITH WATER-TIGHT GROUT ENCLOSURE INSULATED ENCLOSURE SIZED TO FIT RPBA, ASSE 1060 CERTIFIED, SAFE-T-COVER OR EQUAL (NOTE: BURIED VAULT IS NOT PERMITTED FOR RPBA) DRAIN ENCLOSURE DRAIN SIZED IN ACCORDANCE WITH AWWA CROSS CONNECTION CONTROL MANUAL ELECTRICAL CONDUIT RIGID CONDUIT PER ELECTRICAL PERMIT REQUIREMENTS ELECTRICAL OUTLET 120-VOLT OUTDOOR ELECTRICAL OUTLET WITH COVER, INSTALL HEAT TAPE FOR FREEZE PROTECTION CONCRETE SLAB CONCRETE SLAB (MINIMUM 2,000 PSI) SIZED TO FIT RPBA AND ENCLOSURE PER MANUFACTURER, REINFORCED WITH 6x6 W2.9x2.9 WELDED WIRE FABRIC BLOCKING CONCRETE BLOCKING PER STD PLAN 330.1 A B C D E F G H I MATERIALS NOTES: 1.ALL RPBAs MUST BE LISTED ON THE LATEST VERSION OF "BACKFLOW ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY THE STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2.THE RPBA MUST BE TESTED BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER. ASSEMBLY TO BE MAINTAINED BY PROPERTY OWNER. A COPY OF THE TEST REPORT SHALL BE SENT TO THE CITY OF RENTON WATER UTILITY CROSS CONNECTION CONTROL SPECIALIST, FAX 425-430-7207, EMAIL BACKFLOW@RENTONWA.GOV. 3.RPBA AND ENCLOSURE SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. 4.PROVIDE MINIMUM 24" LEVEL, UNOBSTRUCTED AREA AROUND ENCLOSURE. 5.EACH VALVE SHALL BE MARKED WITH MODEL NUMBER AND DESIGNATION OF RESILIENT SEAT, SUCH AS "RS" OR "R", WHICH MUST BE CAST, MOLDED, OR AFFIXED ONTO THE BODY OR BONNET OF THE VALVE. ALL FERROUS-BODIED VALVES SHALL BE COATED WITH A MINIMUM OF 4 MILS EPOXY OR EQUIVALENT POLYMERIZED COATING. J K L 6" MIN A J SERVICE FROM METER SERVICE TO BUILDING D TO OWNER'S ELECTRICAL PANEL 4" MIN 2"FINISHED GRADE K E D L G H12" MIN C B IPROPERTY LINEF PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 3" TO 10" RPBA HEATED ENCLOSURE INSTALLATION DOMESTIC AND IRRIGATION SERVICES STD. PLAN - 360.2 6/28/2023 NOTES: 1.THE RPBA MUST BE LISTED ON LATEST VERSION OF "BACKFLOW ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY THE STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2.THE RPBA MUST BE TESTED BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER. ASSEMBLY TO BE MAINTAINED BY PROPERTY OWNER. A COPY OF THE TEST REPORT SHALL BE SENT TO THE CITY OF RENTON WATER UTILITY CROSS CONNECTION CONTROL SPECIALIST, FAX 425-430-7207, EMAIL BACKFLOW@RENTONWA.GOV. 3.PROTECT AGAINST FREEZING OR DAMAGE. USE HEAT-TAPE IF AREA IS SUBJECT TO FREEZING. 4.RPBA INSTALLATIONS THAT DIFFER FROM THE STANDARD PLAN MUST BE APPROVED BY THE CITY OF RENTON WATER UTILITY AND WILL BE REVIEWED ON A CASE-BY-CASE BASIS TO ENSURE THEY MEET CURRENT MINIMUM REQUIREMENTS FOR INSTALLATION AND FREEZE PROTECTION. 5.EACH VALVE SHALL BE MARKED WITH MODEL NUMBER AND DESIGNATION OF RESILIENT SEAT, SUCH AS "RS" OR "R", WHICH MUST BE CAST, MOLDED, OR AFFIXED ONTO THE BODY OR BONNET OF THE VALVE. ALL FERROUS-BODIED VALVES SHALL BE COATED WITH A MINIMUM OF 4 MILS EPOXY OR EQUIVALENT POLYMERIZED COATING. 6.INTERIOR WATER APPURTENANCES MUST CONFORM TO UPC REQUIREMENTS. MATERIALS A REDUCED PRESSURE BACKFLOW ASSEMBLY LINE-SIZED WASHINGTON STATE-APPROVED RPBA, INCLUDES (2) RESILIENT-SEATED SHUT-OFF VALVES AND (4) RESILIENT-SEATED TEST-COCKS, BRASS PLUGS INSTALLED ON TEST-COCKS PIPE SUPPORT ADJUSTABLE PIPE SADDLE SUPPORT, GRINNELL FIG 364 OR EQUAL, WITH BASE, BOLTED TO FLOOR ADAPTER RESTRAINED FLANGE ADAPTER, EBAA IRON SERIES 2100 MEGAFLANGE OR EQUAL WATER MAIN CLASS 53 DI PIPE (PExFL OR FLxFL) BEND 90° BEND (FLxFL OR FLxMJ WITH RESTRAINED JOINTS) PIPE PENETRATION PVC SLEEVE THROUGH SLAB WITH WATER-TIGHT GROUT DRAIN FLOOR DRAIN FOR RELIEF PORT WITH APPROVED AIR GAP BLOCKING CONCRETE THRUST BLOCKING PER STD PLAN 330.1 B C D E F G SERVICE FROM METER E H 12" MIN 1' TO 5' EXTERIOR BUILDING WALL FINISHED FLOOR SERVICE TO BUILDING D E C B F A H G PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 3" TO 10" RPBA INTERIOR INSTALLATION DOMESTIC AND IRRIGATION SERVICES STD. PLAN - 360.3 6/28/2023 M PLAN ELEVATION DCB A F G 24" MIN 12" MIN 6" MIN A L SERVICE FROM METER SERVICE TO BUILDING G TO OWNER'S ELECTRICAL PANEL 4" MIN 2"FINISHED GRADE M H H N I J I12" MIN F E KPROPERTY LINEH J PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 3" TO 10" RPDA HEATED ENCLOSURE INSTALLATION FIRE SPRINKLER SYSTEMS STD. PLAN - 360.4 Sht. 1 of 2 6/28/2023 REDUCED PRESSURE DETECTOR ASSEMBLY LINE-SIZED WASHINGTON STATE-APPROVED RPDA WITH TWO (2) RESILIENT-SEATED SHUT-OFF VALVES AND FOUR (4) RESILIENT-SEATED TEST COCKS. RPBA SHALL BE INSTALLED EQUIDISTANT FROM ENDS OF CONCRETE VAULT; TWO (2) VALVE SUPERVISORY SWITCHES (ONE PER VALVE) PER RRFA REQUIREMENTS BYPASS 3/4" DETECTOR BYPASS, ALL MATERIALS TO BE BRASS OR COPPER BYPASS METER 3/4" AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BY THE CITY DOUBLE CHECK VALVE ASSEMBLY 3/4" WASHINGTON STATE-APPROVED DCVA WITH TWO (2) RESILIENT-SEATED SHUT-OFF VALVES AND FOUR (4) RESILIENT-SEATED TEST COCKS PIPE SUPPORT ADJUSTABLE PIPE SADDLE SUPPORT, GRINNELL FIG 264 OR EQUAL, WITH BASE, BOLTED TO FLOOR ADAPTER RESTRAINED FLANGE ADAPTER, EBAA IRON SERIES 2100 MEGAFLANGE OR EQUAL WATER MAIN CLASS 53 DI PIPE WITH RESTRAINED JOINTS BEND 90° BEND (FLxFL OR FLxMJ WITH RESTRAINED JOINTS) PIPE PENETRATION SEAL PIPE PENETRATION WITH WATER-TIGHT GROUT ENCLOSURE INSULATED ENCLOSURE SIZED TO FIT RPDA, ASSE 1060 CERTIFIED, SAFE-T-COVER OR EQUAL (NOTE: BURIED VAULT IS NOT PERMITTED FOR RPDA) ELECTRICAL CONDUIT RIGID CONDUIT PER ELECTRICAL PERMIT REQUIREMENTS ELECTRICAL OUTLET 120-VOLT OUTDOOR ELECTRICAL OUTLET WITH COVER, INSTALL HEAT TAPE FOR FREEZE PROTECTION CONCRETE SLAB CONCRETE SLAB (MINIMUM 2,000 PSI) SIZED TO FIT RPDA AND ENCLOSURE PER MANUFACTURER, REINFORCED WITH 6x6 W2.9xW2.9 WELDED WIRE FABRIC BLOCKING CONCRETE BLOCKING PER STD PLAN 330.1 A B C D E F G H I MATERIALS J K L NOTES: 1.THE RPDA AND DCVA MUST BE LISTED ON THE LATEST VERSION OF "BACKFLOW ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE," PUBLISHED BY THE STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2.THE RPDA AND DCVA MUST BE TESTED BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER. ASSEMBLY TO BE MAINTAINED BY PROPERTY OWNER. A COPY OF THE TEST REPORT SHALL BE SENT TO THE CITY OF RENTON WATER UTILITY CROSS CONNECTION CONTROL SPECIALIST, FAX 425-430-7207, EMAIL BACKFLOW@RENTONWA.GOV. 3.EACH VALVE SHALL BE MARKED WITH MODEL NUMBER AND DESIGNATION OF RESILIENT SEAT, SUCH AS "RS" OR "R", WHICH MUST BE CAST, MOLDED, OR AFFIXED ONTO THE BODY OR BONNET OF THE VALVE. ALL FERROUS-BODIED VALVES SHALL BE COATED WITH A MINIMUM OF 4 MILS EPOXY OR EQUIVALENT POLYMERIZED COATING. 4.RPDA AND ENCLOSURE SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. 5.PROVIDE MINIMUM 24" OF LEVEL, UNOBSTRUCTED AREA AROUND HATCH. M N PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator 3" TO 10" RPDA HEATED ENCLOSURE INSTALLATION FIRE SPRINKLER SYSTEMS STD. PLAN - 360.4 Sht. 2 of 2 6/28/2023 INSIDE BUILDING INSTALL FOR 3" AND LARGER DETECTOR DOUBLE CHECK VALVE ASSEMBLY 360.5 50' MAX NOTES: 1.FIRE SPRINKLER SYSTEM SHALL BE LOCATED ON DEDICATED FIRE SERVICE SEPARATE FROM DOMESTIC SERVICE TO THE BUILDING. 2.PIV MUST BE LOCATED ON THE FIRE SERVICE BETWEEN THE ROW AND THE FDC. 3.FIRE MARSHAL SHALL APPROVE FDC AND/OR PIV LOCATION IF LESS THAN 50' FROM BUILDING. 4.THE DCVA OR RPBA MUST BE TESTED BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER. ASSEMBLY TO BE MAINTAINED BY PROPERTY OWNER. A COPY OF THE TEST REPORT SHALL BE SENT TO THE CITY OF RENTON WATER UTILITY CROSS CONNECTION CONTROL SPECIALIST, FAX 425-430-7207, EMAIL BACKFLOW@RENTONWA.GOV. 1 1 2" OR 2" WATER SERVICE PER STD PLAN 320.2 OR 320.3 APPROVED DCVA OR RPBA PIV SEE NOTE 2 FLOOR FLANGE CONCRETE BLOCKING MECHANICAL ROOM ROW PRIVATE PROPERTY FIRE HYDRANT ASSEMBLY W W 50' MAX FDC ASSEMBLY TO BE LOCATED DOWNSTREAM OF BACKFLOW ASSEMBLY 50' MIN SEE NOTE 3 BUILDING PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator COMMERCIAL FIRE SPRINKLER SYSTEM 1 1 2" AND 2" DCVA OR RPBA OUTSIDE INSTALLATION STD. PLAN - 370.1 6/28/2023 50' MAX NOTES: 1.FIRE SPRINKLER SYSTEM SHALL BE LOCATED ON DEDICATED FIRE SERVICE SEPARATE FROM DOMESTIC SERVICE TO THE BUILDING. 2.PIV MUST BE LOCATED ON THE FIRE SERVICE BETWEEN THE ROW AND THE FDC. 3.FIRE MARSHAL SHALL APPROVE FDC AND/OR PIV LOCATION IF LESS THAN 50' FROM BUILDING. 4.THE DCDA OR RPDA MUST BE TESTED BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER. ASSEMBLY TO BE MAINTAINED BY PROPERTY OWNER. A COPY OF THE TEST REPORT SHALL BE SENT TO THE CITY OF RENTON WATER UTILITY CROSS CONNECTION CONTROL SPECIALIST, FAX 425-430-7207, EMAIL BACKFLOW@RENTONWA.GOV. 5.THE FDC AND PIV MAY BE LOCATED WITHIN THE VAULT WITH THE BACKFLOW ASSEMBLY PER STD PLAN 370.3. CONNECTION TO WATER MAIN (1) TEE (FLxFL) (3) GATE VALVES (FLxMJ) WITH CONCRETE BLOCKING APPROVED DCDA OR RPDA PER STD PLAN 350.3 OR 360.4 PIV SEE NOTE 2 FLOOR FLANGE CONCRETE BLOCKING MECHANICAL ROOM ROW PRIVATE PROPERTY FIRE HYDRANT ASSEMBLY W W 50' MAX FDC ASSEMBLY TO BE LOCATED DOWNSTREAM OF BACKFLOW ASSEMBLY 50' MIN SEE NOTE 3 BUILDING PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator COMMERCIAL FIRE SPRINKLER SYSTEM 3" TO 10" DCDA OR RPDA OUTSIDE INSTALLATION STD. PLAN - 370.2 6/28/2023 NOTES: 1.WHERE PIV IS LOCATED INSIDE THE VAULT, THE VAULT LID SHALL BE CORE DRILLED WITH LINK SEAL OR GROUT TO SEAL THE PIPE PENETRATION. ALTERNATIVE PIV LOCATION SHALL BE APPROVED BY THE FIRE MARSHAL. 2.MINIMUM CLEARANCE OF 6" SHALL BE MAINTAINED BETWEEN VALVES, FITTINGS, AND VAULT WALL. 3.ALL PIPE JOINTS SHALL BE RESTRAINED AND CONCRETE BLOCKING IS REQUIRED AT CHANGES IN DIRECTION. 4.CORE DRILL (O.D. +2") CONCRETE VAULT IF KNOCK-OUTS ARE NOT PROVIDED. 12" MINPROPERTY LINE12" MIN24" MIN 6" MIN 12" MIN 6" MIN O O A B F C DB G E H K I OR B B F MATERIALS A BACKFLOW ASSEMBLY DCDA PER STD PLAN 350.3, POSITIONED WITHIN ACCESS HATCH TO ALLOW FOR VERTICAL REMOVAL PIPE CLASS 53 DI PIPE (PExFL OR FLxFL) POST INDICATOR VALVE PIV BETWEEN LAST VALVE ON BACKFLOW ASSEMBLY AND FDC, IN ONE OF TWO POSITIONS SHOWN TEE TEE (FLxFL) ADAPTER ADAPTER (FLxMJ) BEND 90° BEND (FLxFL) VALVE CHECK VALVE (FLxFL) FIRE DEPARTMENT CONNECTION FDC PER RRFA REQUIREMENTS, LOCATED DOWNSTREAM OF BACKFLOW ASSEMBLY, INSTALLED ON THE SIDE OF THE VAULT WITH THE LARGEST AVAILABLE SPACE AS SHOWN CONCRETE VAULT OLDCASTLE PRECAST VAULT OR EQUAL, SIZED TO ACCOMMODATE FDC, PIV, AND CHECK VALVE INSIDE THE VAULT AND MAINTAIN REQUIRED MINIMUM CLEARANCES ACCESS HATCH TWO LOCKING HINGED ALUMINUM DOORS, TRAFFIC-RATED, WITH SLIP RESISTANT TREATMENT, MARKED "WATER", LW PRODUCTS OR EQUAL LADDER GALVANIZED STEEL LADDER SECURED TO VAULT PER STD PLAN 370.5 WALL FLANGE MIDSPAN PIPE RESTRAINT WITH CONCRETE BLOCKING PER STD PLAN 370.4, SEAL PIPE PENETRATIONS WITH WATER-TIGHT GROUT PIPE PENETRATION SEAL PIPE PENETRATION WITH WATER-TIGHT GROUT DRAIN FLOOR DRAIN, MINIMUM 6" PVC, SLOPED TO STORM SEWER OR DAYLIGHT TO DRAINAGE DITCH WITH WIRE MESH RODENT SCREEN AT DRAIN OUTLET, SEAL PIPE PENETRATION WITH WATER-TIGHT GROUT BLOCKING CONCRETE BLOCKING PER STD PLAN 330.1 B C D E F G H I J K N 6" MIN L M N J L M O M L PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator FDC AND CHECK VALVE ROUTED THROUGH BACKFLOW ASSEMBLY VAULT STD. PLAN - 370.3 6/28/2023 PROFILE 24" MIN 6" MIN WALL FLANGE MIDSPAN PIPE RESTRAINT, EBAA IRON SERIES 1100SDB MEGALUG OR EQUAL, WRAP WITH POLYETHYLENE ENCASEMENT PRIOR TO PLACEMENT OF CONCRETE BLOCKING BLOCKING CONCRETE THRUST BLOCKING, CAST-IN-PLACE CONCRETE (MINIMUM 3,000 PSI), TO BE SIZED BY DESIGN ENGINEER (MINIMUM 24"x24"x6") PIPE PENETRATION CORE DRILL (O.D. +2") VAULT IF KNOCKOUTS ARE NOT PROVIDED, SEAL PIPE PENETRATION WITH WATER-TIGHT GROUT GRAVEL FOUNDATION GRAVEL PER WSDOT STANDARD SPECIFICATIONS, 12" MINIMUM ALL DIRECTIONS A MATERIALS B C D D B A C PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator CONCRETE BLOCKING ADJACENT TO VAULT STD. PLAN - 370.4 6/28/2023 12" (TYP.) PLAN PROFILE HINGE HINGE FIRST STEP 8" TO 12" BELOW TOP OF COVER CONCRETE MECHANICAL ANCHOR BOLT, GALVANIZED OR STAINLESS STEEL (TYP.) SIDE RAIL AND BRACKET 11 2" x 1 4" GALVANIZED STEEL (TYP.) RUNG, NO. 8 DEFORMED REINFORCING BAR CONFORMING TO ASTM A615 4" MIN PVC DRAIN TO DAYLIGHT OR STORM DRAIN SYSTEM, WIRE MESH RODENT SCREEN OVER DRAIN NOTES: 1.VAULTS SHALL ONLY BE INSTALLED IN SHOULDERS, SIDEWALKS, OR LANDSCAPED AREAS. VAULTS SHALL NOT BE INSTALLED IN AREAS WITH VEHICULAR TRAFFIC. VAULT COVER SHALL READ "WATER". 2.LADDER TO BE SECURED TO VAULT WALL AT THREE LOCATIONS: TOP, MIDDLE, AND BOTTOM. 3.ALL LADDER PARTS TO BE GALVANIZED CONFORMING TO ASTM A123. 4.ACCESS HATCH SHALL BE LOCKING ALUMINUM DOUBLE DOORS, LW PRODUCTS CO. MODEL HHD-1C OR HHD-2D AS REQUIRED, RATED FOR H-30 LOADING WITH A SLIP RESISTANT TREATMENT AS FOLLOWS: -THERMION, SAFTRAX TH604 GRADE #2 MODERATE TEXTURE -SLIPNOT, GRIP PLATE GRADE 2 (MEDIUM) STEEL -HARSCO IKG, MEBAC #1 -GRATING PACIFIC, ALGRIP SLIP-RESISTANT FLOOR PLATE 5.HATCHES SHALL INCLUDE RECESSED PADLOCK HASP SIZED FOR CITY OF RENTON WATER UTILITY PADLOCKS (CONTACT LW PRODUCTS). 6.LADDER-UP ATTACHMENT REQUIRED ON ALL VAULT LADDERS, BILCO LADDERUP TYPE LU-2. 3" MIN 16" 1" MAX ACCESS HATCH (SEE NOTES 4 & 5) PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator VAULT LADDER STD. PLAN - 370.5 6/28/2023