Loading...
HomeMy WebLinkAboutCA_Parking_Analysis_220812_v1 TENW Transportation Engineering NorthWest Transportation Planning | Design | Traffic Impact & Operations 11400 SE 8th Street, Suite 200, Bellevue, WA 98004 | Office (425) 889-6747 MEMORANDUM DATE: August 8, 2022 TO: Jill Ding, Senior Planner City of Renton FROM: Amy Wasserman TENW SUBJECT: Parking Analysis for the proposed Seattle Sounders FC Headquarters and Training Facility PRE21-000410 / TENW Project No. 2022-073 This memorandum documents the parking analysis for the proposed Seattle Sounders FC Headquarters and Training Facility located in and around Building 25-20 on a portion of the Longacres Office Park („LOP‰) in the City of Renton (see Attachment A vicinity map). The purpose of this memo is to provide justification for and request approval of the proposed parking supply to accommodate the proposed project. This parking analysis includes a project description and parking supply summary, documentation of minimum code required parking, and estimated peak parking demand forecasts based on code requirements and user specific information provided by the owner. Project Description Based on information provided by the owner, the existing Building 25-20 on the LOP site consists of 284,044 square feet (SF) of net building floor area. The proposed Seattle Sounders FC Headquarters and Training Facility project encompasses 52,990 square feet (SF) in the existing Building 25-20. The Sounders will retain 21,660 SF as office use while converting 31,330 SF of existing office use to indoor recreational facilities use. The indoor recreational facilities will provide team services space, which is intended to be accessory to the office and outdoor recreation facilities uses and would include locker rooms, training space, classrooms and workspaces, and medical treatment rooms. The proposed project will also establish an outdoor recreational facility use with five outdoor soccer fields, a goalkeeper training area, and a maintenance shed. Vehicular access to the site would remain the same as existing conditions, with one signalized access and one unsignalized access driveway on Oakesdale Ave SW that provide access to the main parking lot on the south side of the building, and one unsignalized access roadway on the north side of the building that provides access to a visitor parking lot. A preliminary conceptual site plan is provided in Attachment B. Project buildout and occupancy is expected by 2024. Parking Supply As field verified by TENW in July 2022, there are a total of 929 existing on-site surface parking stalls at Building 25-20 as follows (see also Attachment C): · North Lot (north side of building) = 26 stalls · Main Lot (south of building) = 748 stalls · West Lot (southwest of building) = 155 stalls Parking Analysis Seattle Sounders FC Headquarters and Training Facility (Renton) TENW August 8, 2022 Page 2 The proposed outdoor improvements and parking lot improvements associated with the Seattle Sounders FC Headquarters and Training Facility project will result in a decrease of 165 on-site surface parking stalls as follows: · The proposed outdoor soccer training facility will replace the existing West Lot (loss of 155 stalls) · The existing westernmost drive aisle in the Main lot will be reconfigured to remove a total of 68 existing stalls but add 60 new stalls (net loss of 8 stalls) Therefore, a total of 766 on-site surface parking stalls would be provided for Building 25-20 and the Seattle Sounders FC Headquarters and Training Facility project. City of Renton Code-Required Parking The CityÊs requirements for off-street parking are based on Renton Municipal Code (RMC) section 4-4- 080.F.10.d (Parking Spaces Required Based on Land Use) depending on the specific land use category. The minimum code-required off-street parking for the Building 25-20 office use is 2.0 stalls per 1,000 SF of net building floor area based on the requirements for offices (general). Based on a total of 284,044 NSF of building area (including the proposed Sounders FC office use), the minimum parking supply required for Building 25-20 is 568 stalls (2.0 stalls/1,000 NSF X 284,044 NSF). The outdoor soccer training facility proposed as part of the Seattle Sounders FC Headquarters and Training Facility project is not consistent with any of the land uses included under the „recreational and entertainment‰ category in RMC 4-4-080.F.10.d. Therefore, the parking demand associated with the outdoor soccer training facility was estimated based on the detailed project-specific trip generation data and forecasts provided by the owner. Parking Demand Estimate for Outdoor Soccer Training Facility To estimate the peak parking demand of the outdoor soccer training facility on a typical weekday, the detailed entering and exiting trip generation estimates provided by the owner were assigned to 15-minute periods and the entering minus exiting volume was then used to estimate the weekday parking accumulation. The trip generation estimates for the proposed project include players/field use trips, spectators trips (media and public sessions), summer camp/clinic trips, and weekly soccer program trips. Assuming that the parking demand associated with the fields is 0 vehicles at midnight, the estimated peak parking demand for the outdoor soccer training facility use is 164 stalls on an average weekday (occurring from 9:45 AM to 12:00 PM). The trip generation memorandum prepared for the proposed project and the detailed user-specific trip generation forecasts from the applicant are included in Attachment D. It should be noted that the project-specific trip generation forecasts provided in Attachment D for the soccer training facility on a typical weekday are reflective of the peak summer period (June through August) when summer camps/clinics are anticipated to be conducted at the site. The peak parking demand for the soccer training facility is expected to be less than 164 stalls during non-summer months. Parking Analysis Seattle Sounders FC Headquarters and Training Facility (Renton) TENW August 8, 2022 Page 3 Conclusion Based on results of this parking analysis, the total proposed future on-site parking supply of 766 stalls for Building 25-20 and the Seattle Sounders FC outdoor soccer training facility would accommodate the estimated weekday peak parking demand of 732 stalls (568 code-required stalls for the Building 25-20 office use + 164 stalls for the outdoor soccer training facility use). If you have any questions regarding the information presented in this memo, please contact me at (425) 466- 7072 or amy@tenw.com. Attachments: A. Vicinity Map B. Conceptual Site Plan C. Existing Parking Supply D. Seattle Sounders FC Headquarters and Training Facility Trip Generation Memo Parking Analysis Seattle Sounders FC Headquarters and Training Facility (Renton) ATTACHMENT A Vicinity Map Parking Analysis Seattle Sounders FC Headquarters and Training Facility (Renton) ATTACHMENT B Conceptual Site Plan UPSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDx SDx SDx SDx SDx SDx SDx SDx SDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxWxWxWxWxWxWxWxWxWxWxWxWxWx WxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDx C:\Users\Jared Hagedorn\Desktop\21032_SoundersFC-wheelchair_symbol_clip_art_17750-4428995.jpg AS111 A1 75x116 (225x348) 75x116 (225x348) 75x116 (225x348) 75x116 (225x348) 75x116 (225x348) P9 P10 P11 P12 P1 P2 P3P4P5P6 T1T2 T3 P8 T4 P7 A2 A1 12 3 FIELD 1 NATURAL GRASS 97,360 SF FIELD 2 NATURAL GRASS 97,360 SF FIELD 3 SYNTHETIC TURF 97,360 SF 12'x12' BULK STORAGE (2)4 FIELD 4 SYNTHETIC TURF 97,360 SF 5FUTURE FIELD 5 SYNTHETIC TURF 97,360 SF WASH RACK CONDITIONING / UTILITY SPACE NATURAL GRASS 51,492 SF 20 18 19 21 201718192120 19 21 21032 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A 4/4/2022 5:40:59 PM 21032 SEATTLE SOUNDERS FC HEADQUARTERS & TRAINING CENTER 1901 OAKESDALE AVENUE SW RENTON, WA 98057 REV DESCRIPTION DATE SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER HENDERSON ENGINEERS 8345 LENEXA DRIVE, #300 LENEXA, KS 66214 816.663.8700 HENDERSONENGINEERS.COM MEP ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER E R I C J . GOL D NO. 6 90 EX P . 1 0 /2 3 /2022STATE O F W A SHI N GTONLANDSC A P E A R C H ITECTF100 REF EJG COLOR LAYOUT PLAN 07.22.2022 CONDITIONAL USE PERMIT 0 SCALE: 1" = 100' 50' 50' NORTH COLOR LAYOUT LEGEND Parking Analysis Seattle Sounders FC Headquarters and Training Facility (Renton) ATTACHMENT C Existing Parking Supply Parking Analysis Seattle Sounders FC Headquarters and Training Facility (Renton) ATTACHMENT D Seattle Sounders FC Headquarters and Training Facility Trip Generation Memo TENW Transportation Engineering NorthWest Transportation Planning | Design | Traffic Impact & Operations 11400 SE 8th Street, Suite 200, Bellevue, WA 98004 | Office (425) 889-6747 MEMORANDUM DATE: June 27, 2022 TO: Nathan Janders City of Renton FROM: Amy Wasserman TENW SUBJECT: Trip Generation Memo for the proposed Seattle Sounders FC Headquarters and Training Facility PRE21-000410 TENW Project #2022-073 This memorandum summarizes the preliminary traffic information for the proposed Seattle Sounders FC Headquarters and Training Facility located in and around Building 25-20 on a portion of the Longacres Office Park („LOP‰) property in the City of Renton (see Attachment A vicinity map). This memo includes a project description and trip generation estimate. We are requesting your review and approval of this information. Background The approximately 108-acre LOP is composed of 18 parcels located west of Oakesdale Ave SW in Renton, Washington. The Sounders „Site‰ is located within seven of these parcels. Building 25-20 is an existing five-story office building located within the LOP at on parcel no. 088670- 02220 and is approximately 237,532 square feet (net). Building 25-20 has an established headquarters office use with 2,100 average daily trips approved and fully mitigated.1 As background, the City of Renton has conducted extensive environmental review, including traffic analysis for the full buildout of LOP. The Environmental Impacts Statement („EIS‰) Mitigation Document for the LOP was issued in May 1995 and included a Transportation Mitigation Conditions Agreement that, among other conditions, required Boeing to pay the City transportation mitigation fee based on 27,000 average daily trips to be generated by full development of the LOP. The City and the former site owner later established a Reserved Account that contains „Prepaid Trips‰ for future development at LOP. This memorandum supplements the previous LOP transportation review. 1 King County Recording No. 20060420001031, Recital D. Trip Generation Memorandum Seattle Sounders FC Headquarters and Training Facility (Renton) TENW June 27, 2022 Page 2 Project Description The proposed Seattle Sounders FC Headquarters and Training Facility project encompasses 52,990 square feet (SF) in the existing Building 25-20. The Sounders will retain 21,660 SF as office use while converting 31,330 SF of existing office use to Recreation Facilities, Indoor use. The indoor recreational facilities will provide team services space, which is intended to be accessory to the office and outdoor recreation facilities uses and would include locker rooms, training space, classrooms and workspaces, and medical treatment rooms. The proposed project will also establish an outdoor recreational facility use with five outdoor soccer fields, a goalkeeper training area, and a maintenance shed. The proposed outdoor improvements and parking realignment associated with Sounders secure parking will remove 166 parking stalls. A supplemental parking study will be provided. Vehicular access to the site would remain the same as existing conditions, with one signalized access and one unsignalized access driveway on Oakesdale Ave SW that provide access to the main parking lot on the south side of the building, and one unsignalized access roadway that provides access to a visitor parking lot on the north side of the building. Secondary vehicular access will be provided via an existing full access driveway on 384th Ave SE. A preliminary conceptual site plan is provided in Attachment B. Project buildout and occupancy is expected by 2024. Trip Generation The weekday trip generation estimates for the proposed and existing office use were based on methodology documented in the Institute of Transportation Engineers (ITE) Trip Generation Manual, 11th Edition for Land Use Code (LUC) 710 (General Office Building). Based on information provided by the applicant and preliminary discussions with the City of Renton, the proposed outdoor soccer training facility is not consistent with a specific land use category established in the Institute of Transportation Engineers (ITE) Trip Generation manual. ITE LUC 488 (Soccer Complex) was considered, but was determined to not be appropriate to forecast trip generation for the proposed Seattle Sounders soccer training facility. As such, project-specific information was used for the average weekday trip generation estimates. To estimate trip generation for the proposed Sounders training facility, the owner provided detailed forecasts of trips anticipated to occur on a typical weekday based on their operational plan. These weekday trip estimates are provided in Attachment C and described in the following categories: Players/Field Use Trips – The fields are anticipated to be used daily from approximately 8:00 AM to 10:00 PM, however not all fields will be used at the same time. The peak usage of the fields and training facility is anticipated to occur between 10:00 AM and 1:00 PM. Spectators Trips (Media and Public Session) – On a daily basis, it is anticipated that media and a select number of visitors may view team practices on an invitation only basis. Summer Camp/Clinic Trips – Summer camps run June through August and would consist of a maximum attendance of 120 students per week, with camp/clinic hours generally between 9:30 AM and 4 PM Monday through Thursday and between 9:30 AM and 12:00 PM on Friday. Trip Generation Memorandum Seattle Sounders FC Headquarters and Training Facility (Renton) TENW June 27, 2022 Page 3 Weekly Soccer Program Trips – The weekly soccer program consists of a skills class that would have a maximum attendance of 50 students attending class 3 times per week during off peak hours (i.e. 5:30 PM to 7:00 PM). It should be noted that the project-specific trip generation forecasts for the soccer training facility on a typical weekday are reflective of the peak summer period (June through August) when summer camps/clinics are anticipated to be conducted at the site. The resulting new weekday daily, AM peak hour, and PM peak hour trip generation estimates associated with the proposed Seattle Sounders FC Headquarters and Training Facility development are summarized below in Table 1. The detailed trip generation estimates are included in Attachment C. Table 1 Project Trip Generation Summary Net New Trips Generated Time Period In Out Total Weekday Daily 73 74 147 Weekday AM Peak Hour -2 -7 -9 Weekday PM Peak Hour 56 -42 14 It should be noted that trips associated with the proposed 31,330 SF of building area for team services space are assumed to be included in either the office use or outdoor recreation facility use trip generation estimates and were therefore not estimated separately. Next Steps The proposed Seattle Sounders FC Headquarters and Training Facility project would generate less than 20 net new trips during the AM and PM peak hours, therefore we believe no additional traffic analysis is required for this development pursuant to the CityÊs direction in PRE21-000398 (Transportation, Item #5). We look forward to your review and approval of our trip generation estimates and consensus that no additional traffic analysis is necessary. Please contact me at (425) 466-7072 or mailto:amy@tenw.com if you have any questions regarding the information included in this memorandum. Attachments: A. Vicinity Map B. Preliminary Site Plan C. Trip Generation Forecasts and Calculations Trip Generation Memorandum Seattle Sounders FC Headquarters and Training Facility (Renton) ATTACHMENT A Vicinity Map Trip Generation Memorandum Seattle Sounders FC Headquarters and Training Facility (Renton) ATTACHMENT B Preliminary Site Plan XXXSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDx SDx SDx SDx SDx SDx SDx SDx SDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxWxWxWxWxWxWxWxWxWxWxWxWxWxWxWxWxWx WxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSD x SDx SDx SDx SDxSDxSDx SDx SDxSDxSDxSDxSDxSDxSDx SDxSDxSDxSDx75x116 (225x348) 75x116 (225x348) 75x116 (225x348) 75x116 (225x348) 75x116 (225x348) P9 P10 P11 P12 P1 P2 P3P4P5P6 T1T2 T3 P8 T4 P7 A2 A1 NEW OPENING INEXISTING CURTAINWALLFOR OH SECTIONAL DOORNEW DOORS IN EXISTINGCURTAINWALLNEW DOORS IN EXISTINGCURTAINWALL42" DRINK RAIL30" DRINK RAIL (ADA)30" DRINK RAILEXISTING CARPORT CANOPY CUT BACKTO ALIGN WITH WEST BUILDING EDGEUPUPUP12 3 FIELD 1 NATURAL GRASS 97,360 SF FIELD 2 NATURAL GRASS 97,360 SF FIELD 3 SYNTHETIC TURF 97,360 SF 12'x12' BULK STORAGE (2)4 FIELD 4 SYNTHETIC TURF 97,360 SF 5FUTURE FIELD 5 SYNTHETIC TURF 97,360 SF WASH RACK FUTURE RESTROOM CONDITIONING / UTILITY SPACE NATURAL GRASS 51,492 SF 21032 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A 4/4/2022 5:40:59 PM 21032 SEATTLE SOUNDERS FC HEADQUARTERS & TRAINING CENTER 1901 OAKESDALE AVENUE SW RENTON, WA 98057 REV DESCRIPTION DATE SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER HENDERSON ENGINEERS 8345 LENEXA DRIVE, #300 LENEXA, KS 66214 816.663.8700 HENDERSONENGINEERS.COM MEP ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER F110 REF EJG LAYOUT PLAN 05.23.2022 SCHEMATIC DESIGN 50% NORTH 0 SCALE: 1" = 80' 40' 40' Trip Generation Memorandum Seattle Sounders FC Headquarters and Training Facility (Renton) ATTACHMENT C Trip Generation Calculations Land Use Size / Units ITE LUC 1 Trip Rate or Equation 1 Enter Exit Enter Exit Total DAILY Proposed: General Office Building 21,660 SF 710 Ln(T) = 0.87 Ln(X) + 3.05 50%50%153 154 307 Soccer Training Facility 2 ------50%50%254 254 508 Less Existing: General Office Building 52,990 SF 710 Ln(T) = 0.87 Ln(X) + 3.05 50%50%-334 -334 -668 Proposed Gross Daily Trips Generated =407 408 815 Less Existing Trips =-334 -334 -668 Total Proposed New Daily Trips =73 74 147 AM PEAK HOUR Proposed: General Office Building 21,660 SF 710 Ln(T) = 0.86 Ln(X) + 1.16 88%12%40 5 45 Soccer Training Facility 2 ------100%0%43 0 43 Less Existing: General Office Building 52,990 SF 710 Ln(T) = 0.86 Ln(X) + 1.16 88%12%-85 -12 -97 Proposed Gross AM Peak Hour Trips Generated =83 5 88 Less Existing Trips =-85 -12 -97 Total Proposed New AM Peak Hour Trips =-2 -7 -9 PM PEAK HOUR Proposed: General Office Building 21,660 SF 710 Ln(T) = 0.83 Ln(X) + 1.29 17%83%8 39 47 Soccer Training Facility 2 ------100%0%65 0 65 Less Existing: General Office Building 52,990 SF 710 Ln(T) = 0.83 Ln(X) + 1.29 17%83%-17 -81 -98 Proposed Gross PM Peak Hour Trips Generated =73 39 112 Less Existing Trips =-17 -81 -98 Total Proposed New PM Peak Hour Trips =56 -42 14 Notes: 1. Land Use Codes, trip rates, and directional splits from Institute of Transportation Engineers (ITE) Trip Generation Manual (11th Edition, 2021) unless otherwise noted. 2. Trip generation for the soccer training facility/team services based on user-specific trip generation forecasts provided by the Client. Sounders FC Office & Training Facility Weekday Trip Generation Estimates Directional Split 1 Vehicle Trip Generation 6/17/2022 Sounders FC Office & Training Facility Trip Generation Forecasts - Average Weekday during Summer Outdoor Recreational Facility Use Time Period Entering Exiting Comment Entering Exiting Comment Entering Exiting Comment Entering Exiting Comment Entering Exiting Comment Entering Exiting Total Hour Entering Exiting Total 12:00 - 1:00 AM 0 0 0 0 0 0 0 0 0 0 0 0 0 12:00-1:00 AM 0 0 0 1:00 - 2:00 0 0 0 0 0 0 0 0 0 0 0 0 0 1:00-2:00 AM 0 0 0 2:00 - 3:00 0 0 0 0 0 0 0 0 0 0 0 0 0 2:00-3:00 AM 0 0 0 3:00 - 4:00 0 0 0 0 0 0 0 0 0 0 0 0 0 3:00-4:00 AM 0 0 0 4:00 - 5:00 0 0 0 0 0 0 0 0 0 0 0 0 0 4:00-5:00 AM 0 0 0 5:00 - 6:00 0 0 0 0 0 0 0 0 0 0 0 0 0 5:00-6:00 AM 0 0 0 6:00 - 6:30 0 0 0 0 0 0 0 0 0 0 0 0 0 6:00-7:00 AM 0 0 0 6:30 - 7:00 0 0 0 0 0 0 0 0 0 0 0 0 0 6:30-7:30 AM 0 0 0 7:00 - 7:30 0 0 0 0 0 0 0 0 0 0 0 0 0 7:00-8:00 AM 0 0 0 7:30 - 8:00 0 0 0 0 0 0 0 0 0 0 0 0 0 7:30-8:30 AM 4 0 4 8:00 - 8:30 4 0 0 0 0 0 0 0 0 0 4 0 4 8:00-9:00 AM 43 0 43 8:30 - 9:00 4 0 0 0 0 0 35 0 0 0 39 0 39 8:30-9:30 AM 98 0 98 9:00 - 9:30 9 0 0 0 0 0 50 0 0 0 59 0 59 9:00-10:00 AM 121 0 121 9:30 - 10:00 20 0 12 0 30 0 0 0 0 0 62 0 62 10:00 - 11:00 0 0 0 0 0 0 0 0 0 0 0 0 0 10:00-11:00 AM 0 0 0 11:00 - Noon 0 0 0 0 0 0 0 0 0 0 0 0 0 11:00-12:00 PM 0 0 0 12:00 - 1:00 0 0 0 12 0 30 0 0 0 0 0 42 42 12:00-1:00 PM 0 42 42 1:00 - 2:00 0 20 0 0 0 0 0 0 0 0 0 20 20 1:00-2:00 PM 0 20 20 2:00 - 3:00 0 17 0 0 0 0 0 0 0 0 0 17 17 2:00-3:00 PM 0 17 17 3:00 - 3:30 10 0 0 0 0 0 0 20 0 0 10 20 30 3:00-4:00 PM 20 85 105 3:30 - 4:00 10 0 0 0 0 0 0 65 0 0 10 65 75 3:30-4:30 PM 15 65 80 4:00 - 4:30 5 0 0 0 0 0 0 0 0 0 5 0 5 4:00-5:00 PM 10 0 10 4:30 - 5:00 5 0 0 0 0 0 0 0 0 0 5 0 5 4:30-5:30 PM 65 0 65 5:00 - 5:30 10 0 0 0 0 0 0 0 50 0 5:30-7 camp 60 0 60 5:00-6:00 PM 60 0 60 5:30 - 6:00 0 0 0 0 0 0 0 0 0 0 0 0 0 5:30-6:30 PM 0 15 15 6:00 - 6:30 0 15 0 0 0 0 0 0 0 0 0 15 15 6:00-7:00 PM 0 20 20 6:30 - 7:00 0 5 0 0 0 0 0 0 0 0 0 5 5 7:00 - 8:00 0 5 0 0 0 0 0 0 0 50 0 55 55 7:00 -8:00 PM 0 55 55 8:00 - 9:00 0 15 0 0 0 0 0 0 0 0 0 15 15 8:00-9:00 PM 0 15 15 9:00 - 10:00 0 0 0 0 0 0 0 0 0 0 0 0 0 9:00-10:00 PM 0 0 0 10:00 - 11:00 0 0 0 0 0 0 0 0 0 0 0 0 0 10:00-11:00 PM 0 0 0 11:00 - 12:00 0 0 0 0 0 0 0 0 0 0 0 0 0 11:00 PM - 12:00 AM 0 0 0 TOTAL TRIPS 77 77 12 12 30 30 85 85 50 50 254 254 508 TRIP GENERATION SUMMARY Entering Exiting Total Daily Trip Generation 254 254 508 AM Peak Hour 43 0 43 8:00-9:00 AM PM Peak Hour 65 0 65 4:30-5:30 PM Hourly Trip Totals Trip Totals Summer Camps (June - August) 120 max attendance Soccer Program - Weekly Class 50 max attendance 3x/week - 24 weeksField Use (Players/Coaches) Spectators - Media 100 max attendance Spectators - Public Session 6/17/2022