Loading...
HomeMy WebLinkAboutP_A3.1_ELEVATIONS_191018_v2NO.DATEDESCRIPTION1THIS DOCUMENT REPRESENTS A PROPRIETARY DESIGN OWNED BY THE ARCHITECT AND SHALL NOT BE USED ON OTHER PROJECTS OR ADDITIONS TO THIS PROJECT OR FOR COMPLETION OF THIS PROJECT BY OTHERS EXCEPT BY PRIOR ARRANGEMENT IN WIRTING COPYRIGHT © 4:24 PM ON Monday, July 25, 2022 BY BRODERICK ARCHITECTS, PLLC21.039 PLOT DATE: 7/25/22 Shawn Keenan 21.039 Duvall Ave NE Office Building_211101_Alt Scheme_AC241625 DUVALL AVENUE NE • RENTON, WA 98059DUVALL OFFICE BUILDINGNEW COMMERCIAL BUILDINGDEDICATED APPROVAL STAMP SPACEA3.1 ELEVATIONS SCHEMATIC DESIGN 10/18/19 00/00/00 PERMIT CORRECTIONS 01F DE C B A X 8'-0"T.O. CAP ELEV. +423'-10 1/2" T.O. CAP ELEV. +422'-6 1/2" T.O. CAP ELEV. +427'-10 1/2" ±3' 4":12" H GGAA G H. TRIM BAND CONT. AROUND CORNER WEST PROP LINEWASTE/RECYCLING ENCLOSURE DRIVEWAY, GARAGE ENTRANCE RPPA ELEV. +419'-0" ELEV. +429'-8" ELEV. +439'-8" 2.93 2 1543.6 03.4 3.2 ±0" GROUND FLOOR +10'-8" 2ND FLOOR +20'-8" ROOF +5'-2 1/8" (ELEV.+424'-2 1/8") +26'-4 11/16" (ELEV. +450'-6 7/8")26'-4 11/16"10'-8"10'-0"10'-10 7/8"10'-0"8'-0"±8'-6"±5'-8" T.O. CAP ELEV. +420'-6 1/2" T.O. CAP ELEV. +427'-10 1/2" 11'-0"1'-6 1/2"4":12"4":12" 3":12" C 100 ELEV. +424.18' AVE. FIN. GRADE (RMC) TYPICAL BUILDING FINISHES: STANDING SEAM METAL ROOFING GALV GUTTERS & DOWNSPOUTS & MISC GALV COPING & FLASHING, FACTORY COLOR TO MATCH ROOF COLOR 2x8 BORAL TRUEXTERIOR FASCIA, WOOD GRAIN, PTE-1, INSTALL OVER SUBFASCIA BORAL TRUEXTERIOR TRIM, WOOD GRAIN, SIZE AS NOTED, PTE-1, PROVIDE CONT Z-FLASHING ABV UNO HARDIEPLANK LAP SIDING, SELECT CEDARMILL, 7" EXPOSURE, PTE-2 DS, TYP FREESTANDING CMU COLUMN LOW SLOPE ROOF BEYONDPARAPET BEYOND 5/4x6 5/4x6 5/4x85/4x85/4x45/4x6 5/4x6 5/4x85/4x45/4x45/4x41x4 5 /4 x 6 BUILDING NUMBER SIGN H. TRIM BAND EXTENDS AROUND CORNER, TYP TYP CONC CAP, COLOR TO MATCH CMU SOUTH PROP LINE NORTH PROP LINE CMU SITTING WALL w/ CONC CAP, TYP (E) CMU BLOCK WALL RECONTOUR TOP IN FRONT OF SITE TO FOLLOW NEW GRADES ±EXIST. GRADE CYLINDRICAL SCONCE, TYP 26.39' PROPOSED BUILDING HEIGHT (RMC)PL. D FBCEA APPROX. LOCATION OF CONC. RET. WALL ON NEIGHBOR'S PARCEL ADJACENT TO SOUTH PROPERTY LINE 1 2 3 4 52.9 3.603.2 3.4 T.O. CAP ELEV. +426'-6 1/2" 4":12" H E E E E SOUTH PROP LINENORTH PROP LINE FLUSH PANEL STEEL DOORS, PAINT GRAY TO MATCH CMU CEDAR TRELLIS w/ CLEAR COAT, TYP T.O. CAP ELEV. +427'-10 1/2" PARKING BEYOND ROOF WELL BEYOND B D E FC E H. TRIM BAND CONT. AROUND CORNER 1 3/16" = 1'-0" 5 A3.1 NORTH ELEVATION - NE 17TH STREET 0 4'8'12' 3/16" = 1'-0" 2 A3.1 EAST ELEVATION - DUVALL AVENUE NE 0 4'8'12' 3/16" = 1'-0" 3 A3.1 SOUTH ELEVATION 0 4'8'12'3/16" = 1'-0" 4 A3.1 WEST ELEVATION 0 4'8'12' 3/16" = 1'-0" 1 A3.1 SOUTH ELEVATION AT ELEVATOR 0 4'8'12' EXTERIOR MATERIALS (PHOTO OF SIMILAR PROJECT) CMU BLOCK. COMBINATION OF STANDARD AND GROUND FACE BLOCK IN NATURAL GRAY COLOR IN RANDOM PATTERN LAP SIDING HARDIE LAP SIDING W/ 7" EXPOSURE, PTE-2 PAINT COLOR FASCIA 2X8 CEDAR FASCIA PTE-1 PAINT COLOR TRIM & BANDING: 2X HARDIE TRIM PTE-1 PAINT COLOR CMU CAP. NATURAL GRAY COLOR ALUM STOREFRONT WINDOWS & DOORS ANNODIZED ALUM. GRAY COLOR STANDING SEAM METAL ROOFING & FLASHING GRAY COLOR