Loading...
HomeMy WebLinkAboutLUA99-170 - Large Format PROPRIETARY INFORMATION = THE INFORMATION CONTAINED IN THIS SET OF = CONSTRUCTION DOCUMENTS IS PROPRIETARY BY Oo NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO VOICESTREAM WIRELESS < Il CORP. SERVICES IS STRICTLY PROHIBITED. = _t azul uJ T fe O ra oiceStream WIihREtLES § OLD RENTON TOWN HALL 200 MILL AVENUE SOUT RENTON, WASHINGTON 98055 Fr —-2ZOO05S—-A VoiceStream 19807 NORTH CREEK PARKWAY NORTH, bet Thu Dec 09 413: 38: 46 1999 W. nox race I VICINITY MAP GENERAL LOCATION MAP PROJECT INFORMATION SHEET INDEX ee Lake Union Clyde Hill 55, uy a 4 a a OPrvster Ai : 3 = Bo mie es 4 NETWORK SYSTEM OWNER: LANDLORD: = TITLE SHEET "7 ey 4 a Pe x pa ied : asi = ‘ae con 3 a : & Medina _ , yo € 4 | Gi *% -* | VOICESTREAM WIRELESS Ill CORPORATION CITY OF RENTON h» meme 4 oy ® mood wig Tt Be es 19807 NORTH CREEK PARKWAY NORTH 1055 SOUTH GRADY WAY gl GENERAL NOTES, SYMBOLS & ABBREVIATIONS “7 - % L - sO i or = ao = @ “of. BOTHELL, WA. 98011 RENTON, WA. 98055 W. Knox Fitzpatrick lll, Eiiod & dk My Bellevue Oe, So wm... ord. St bi i CONTACT: MIKE JANSSEN PH: (425) 430-6606 Architect & Associates - es ws st SITE a ss D a 2 PH:(425) 829-0056 CONTACT: DENNIS CULP Wood Creek Business Park : a tke Se gs 12810 N.E. 178th Street x Roanoke st = . x = o ont a~1 SITE PLAN Suite 230 os = 5 oe nrore é rc Aimart Hua a = PROJECT DESCRIPTION: Woodinville, WA 98072 . b 2 | S " = ad ee aM. 2h St _ VOICESTREAM WIRELESS lll CORP. PROPOSES TO CONSTRUCT AN UNMANNED RADIO a-2 ENLARGED ROOF PLAN ph: (425) 415-0746 = ap Mercer Island) ppataoss i DM ey v. B® - TELECOMMUNICATIONS FACILITY CONSISTING OF A THREE-SECTOR ANTENNA ARRAY fax: (425) 415-0799 2 * 2 fee Mebrex f i Dt reresed oe o Way N * WITH (3) ANTENNAS PER SECTOR (9 ANTENNAS TOTAL) SKID-MOUNTED ON THE a~3 CONSTRUCTION PLAN & ELEVATION . 8 ye | Hewport S } es nih St vw < - ROOF OF AN EXISTING BUILDING WITH INTRATALK EQUIPMENT RACKS LOCATED WITHIN DATE: 11-16-99 % 3 | Island : Actota ws ; De ey ee / EXISTING MECHANICAL AREA OF THE SEVENTH FLOOR. aranid CONSTRUCTION DETAILS ATE: 11—16— ee Py fn a 2 a= cee ve a e = ca Ay BER 3 anc DRAWN BY: JBK ey 39 18? : vat aed wm = { BAGS E it ia §. = Lt fi 6 io [ fi CHECKED BY: WKF : § oe ee eee E Say Penis, gage tora | ZONING: a “ARCELNIMBER(S): | e-1 GROUNDING PLAN, DETAILS & NOTES REVISIONS Pi e = mo 2nd ot 9 20 32 1900 _ y han CD +£3.91 ACRES 000 720 0050 TELEPHONE /ELECTRICAL DETAILS iB os ae = . i. +4 fe Gd i Refiton 7 DATE) DESCRIPTION | INITIAL : baking Fiettrcing , ™ poneAR MC g 8 = ie ss JURISDICTION: PROJECT AREA: | SLO i hat! rity nt y PAS AA Pope. apes ab. od a —_ ya 1 RE F ° , : Auper : : Se (7 a 900 2 CITY OF RENTON +1500 s.f. PORES PRE aA Raa Be ee White Center |. " S ITE : P ry = = oe ee =_—— Coalfield Bap > & in GEN INE N-2-9IFINAL CD’S|JBK Southern aan bei ieee 4 | pre ooo = 3 ENERAL ORMATION: Heights | " yn > \g, Will Rogers miley Post Memorial Airport y Sle ag a 1. PARKING REQUIREMENTS ARE UNCHANGED. 12-7-9|REV. FINAL CD’S|JFO Seola Beach Allentown % Sicway, : ; & a ee 0 " 2. TRAFFIC IS UNAFFECTED. | . ‘ a 7 ee | == a Boulevard | Renton Municipal SE 12 as) Aes A oy * 3. NO SIGNAGE IS PROPOSED. erocd - Park Fier . ahs et = to Ot 4. UBC CLASSIFICATION (1997 ED.) Inglesea_ riecseae aC 900 we sane eee ee roe a Lf 5. OCCUPANCY GROUP: B CONSTRUCTION TYPE II F.R. : % Faeter ; ; W SSURSE ss me fb « 6. SEISMIC ZONE #3 s os Burien : AG i Eliott | » g 2 = = : Riverton “i lal e. “ ‘ pas co : = Fie ah SITE NUMBER th | Sunnydale... leights potas Maplewour * c A a We 5 Ae) Sunnydale <> eS — 5 a ie is APPROVAL SIGN OFF FOR CONSTRUCTION DRAWINGS : oe = Sethst = tc ve , Tukwil B : : au — _ Five Corners) Elustioghe 7. L 5 e = Now 1k DATE SIGNATURE SE-2905-A — pternational, oo ate (S18 SE Ay ; fai : 2 G : By Aupot— 18!) ovintia Probie | E oe Fy LANDLORD’S REPRESENTATIVE OLD RENTON T.H. IA a. Rod SoH sere é ce Eo @ Tre soo) S 188th St ne mo @:1 ZONING MANAGER 200 MILL AVENUE S. “N SITE ACQUISITION REP. RT: ee PSEe R.F. ENGINEER PROJECT MANAGER A&E/CONSTRUCTION MANAGER ea NING opMENTPLAN SME-F1-/ FO bev TY OF RENTO NOTE: Kroll Maps are compiled from Official Records f 2 N TO N W v2 (7 -23 a 5 319W and Field Surveys. They are produced for reference use | aI | | | | | | | | a | only and no warranty is expressed or implied. i 4 t mee J L 4 . ee ed ° omy: ‘ 3 . . EJ 4 19 25] - Ep 194?" Li a = eS = . Ge} !7 || 10 G33 - 10 a. Se ) |) Ps Er Fa pet 268) 8 |} 3 [335] - >| 9175 re ; “fg 6 | | 2l faa ges Je | | 2150 - Bs A SE BRS GT BH? Loa | Ee TL) 2 al x if sao 7 | Mah +s fe oba| (oo seam tg’ S . G22) || 6 Gals y= $51 Ske 9, A ES} S |. Gag 9 | | [28 225) Gq 2 || 5 pal. st 8 18 x 01/2 10} [ar 7 7 i i ig] my 9 s rae O Lj heel ai: ai Lj ee afd, | [aes EB 1S | |b = miele?) | Ste qi SbB2/[SBiNe 1S Eas NX Cy Ui aly vy) A FS] 6 ww a BS) 6 Gay i) 7 J} f 38g] fea Lies) |p (8 (3). Varies MET b> b aad ; 3 Ba 4 | | 7 Bel - 5 6 7 yg 2 ‘ pas rick Ww fs (228)20 | foijez3 ( 1A - eh 2! 22 [E) - S : a = = > El} 22 v5) Hoe ry / ; S 24 [277] : p ; dpe? P7520 ine § Ss) ea ne’ Sh rs Bre af Fig tet 10 [lis} - Rs Q 3 i Lg peg iol) rT 67] | |i (8) 9 LIBERTY PARK; [pg eal | i t Cedar River oe | | ~@-)« cl val { i in i 7 8 es 9 LDLD) yo ae met BE a ig 3 7 KP pet? | E * 6. ou SLA! ae Leek | te 1 4e y| i) AY. Le a N 6? 2, K = 3RD ST™ : Pa ie ae TL. 197 - G a “(ETE ee er oe 00 Fe Gi B > Wik | IEEE By KS. oe. 2 tA 25, ee See Cee x 3 A i ee eS ; Sf 3| 18 pa er hee al ES ee jee Sf = 4\a SS 7 $y * De! ent * fod Qa S 5 SAN MH fw 2 Bs a ee a 3 : \ EO | | 319 als ep 0 ‘A Govt ras ‘ ‘ oO £80 awd hee : SY Ege te | | B2Qaeres ¢ ww a4 _, : ie << eames t : 8 s xl E aI i = } 5 g * = Cre& ST 8 7 5, id ‘ ug 5 ‘ oo ay & \Tonkin P 21 {" — fe ok S. t 7E 30 5 ae S : | {44 1 fe i FO a) S W229 pf ipie 9 Be we. 4 —_ = Biz ; bey) 9 By) E ee 71 Ig a aT oa ae 31} Bis Gp 3]| 18 . Ga 3) 8-4. ! pe LFF oh ‘ee mn ee EX es La — F ne Sout ThE OREN +} JORIN q fe a , - ee eee i Piet 6 BOs) beet” Sal ais Gl F J4102 glelPyoh A Y f " tt Y) 19 1 ecH0 t 61] 5 B® . > ‘ oifis 3} i er, M5? a eee 3 7) was fee | doy ET Tay , a ee wie? si re ack ari oes: This ha pole} St ie SE ll Bia Sb 0 wm AS Re : : 4 ! | [20 ole to ‘ga « = & A ot Z. ! ] ; q ge ro QO 3 2 |e) | Boa | fai igdeels ] ft } - —2lfe bal Roe OS ok = apfe te vl 3} 1B of - BE 3] 8 gay] faGeTs Hara $80 3 fi fem ile yom] | y aS ; 2 YF 3 5 oy S a af se | foe ape | Weel ei . a alla y may g q ‘4 R 1 ais : 4 : Xi be | | OB Sg BA} + RA Shee ko a | 5shie bol f B _! : a t ww he tba xq i ii ae rag See Sea BI} fd of Bl] bey ois iS pe epee: a5" = : cS a" <j = 25) | 2 = 1) 4 Bo} -e 7) 4 gy +B? & : Y | Ga) 7/| 4 Be- - a S ‘ ’ Bp 4 : f 8 ee J 18 j958)| 3 1 ims = ‘ : 536 MILL | [2 . Ge «4 e] j oo RE St eH OE | ‘ hy ‘ . ACOND.BUNITS! |) fie q | i x : S$ F6THESTIM O ee s : ca Bee. eB tae gaee : Eire k J : R g al, | ébs) q . Se -— 1. “HS q 5 K § : Sy ; 2 a q ly : ] x a. ir pees 1 Ia § u ess fas Re) : 40 Is Po Ya, |§ F010 36: P 028Ac. 722 of PugéT | Sound 32 q 232,46 F Reine Mee ere Bay POWER [g_&IGMT COs: . : q i HEIMT, | eo ’ fren ila preerw: TTLE ee ee HE oT City MENT p | ATL AS OF SE A LE short plats, condominiums, and ccrporate limits. Addressing and structural information is | 337W LEGEND OF REN CANNING in "COPYRIGHTED & PUBLISHED BY | Scat ote ainsi | County Tax LotNo (2) —_ House Number D TON KROLL MAP COMPANY, INC., SEATTLE ee Building Co sPrivate Road ce te EC 0) 194 SCALE: 1 INCH = 200 FEET App’ox Stories (2 © Short Piat SP.178144 REc 9 QME-979-1 2p SIVED 's | N | AL NOTES DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS : NOTED OTHERWISE. THE GENERAL CONTRACTOR’S SCOPE OF WORK SHALL INCLUDE Pao: FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS AND OWNER’S , PROJECT MANUAL. DRAWINGS WERE PREPARED FROM STANDARDIZED DETAILS DEVELOPED AND PROVIDED BY ~W. KNOX FITZPATRICK Ill AND ASSOCIATES, AND VOICESTREAM WIRELESS Il CORPORATION. STANDARDIZED DETAILS ARE TO BE CONFIRMED AND CORRELATED AT THE SITE BY THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR ALL DIMENSIONS. STANDARDIZED DETAILS THAT REQUIRE MODIFICATIONS DUE TO ACTUAL FIELD CONDITIONS AND REQUIREMENTS MUST BE SUBMITTED TO, AND APPROVED BY, VOICESTREAM WIRELESS ll CORPORATION PRIOR TO START OF WORK. : PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION /CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. . THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE 3 CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. . THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL - CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER S/VENDOR’S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES: OR ORDINANCES TAKE PRECEDENCE. . ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THES PERFORMANCE OF THE WORK. GENERAL CONTRACTOR. SHALL PROVIDE, Al THE “PROJECT SITE, -A FULL -SET OF CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. THIS SET IS A VALID CONTRACT DOCUMENT ONLY IF THE TITLE SHEET IS STAMPED IN RED INK “FOR CONSTRUCTION’ AND EACH SUCCESSIVE SHEET BEARS THE ARCHITECT’S SIGNED WET STAMP... # THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. SEAL ALL PENETRATIONS THROUGH FIRE—RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2—A OR 2—A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF bee PRO AREA DURING CONSTRUCTION. ee 13: 14, vO; 16. Lae CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, CASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. ‘CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH. CONTRACTOR SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR’S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER’S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. THE CONTRACTOR SHALL PROVIDE VOICESTREAM WIRELESS lll CORPORATION PROPER INSURANCE CERTIFICATES NAMING VOICESTREAM WIRELESS Ill CORPORATION AS ADDITIONAL INSURED, AND VOICESTREAM WIRELESS Ill CORPORATION PROOF OF LICENSE(S) AND PE & PD INSURANCE. CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATING SPECIAL AND BUILDING DEPARTMENT INSPECTIONS. ESS WIREL 19807 NORTH CREEK PARKWAY NORTH, BOTHELL, WA. 98011. YT UD) Vv EP SS ma aed 4 as W. Knox Fitzpatrick Ill, Architect & jates Wood Creek Business Park — 12810 N.E. 178th Street — Suite 230- Woodinville, WA 98072 ph: (425) 415-0746 fax: (425) 415-0799 DATE: 11-16-99 DRAWN BY: JBK CHECKED BY: WKF REVISIONS DATE] DESCRIPTION | INITIAL N-6-SIPRELIM CD’S|JBK N-2-9 FINAL CD'S} JBK 12-7-9IREV. FINAL CD’S|JFO SITE NUMBER SE-2505—-A OLD RENTON T.H. 200 MILL AVENUE S. RENTON, WA. 98055 g-1 Q A-99- ['F 0 ove OF FENTON 0 88 34.108 | 19807 NORTH CREEK PARKWAY NORTH, BOTHELL, WA. 98011 be fs. ee eee, —— —— —— — — e, ——_ — ac — a, _——— —— ee oe, oe a ae eee aoe ee me we eee oe ASSUMED ORDINARY HIGH WATER MARK (NOT SURVEYED) WIRELESS INTRATALK EQUIPMENT RACKS IN FENCED OFF PORTION OF 6TH FLOOR PCS ANTENNA ARRAY W/ SKID—MOUNT SUPPORT FRAME MOUNTED ON ROOF OF gh Roy Rene. 1 SHEET g=2Z & FOR ENLARGED SITE PLAN Rog bas! Ean a ee lal aa i eRe ‘ Ny AA RAOTT, ine W. KNOX FTAPATRICK i : STATE OF WASHINGTON es . oe x aN < \ E] PARKINGN > v Eyer ye VE 5 Pg : LEGAL DISCRIPTION oP. ve) 4 Re vA \ ly ae a» dm od a ‘ y oe J £ LOTS 1 THROUGH 13, INCLUSIVE, BLOCK 2, TOWN OF RENTON, ACCORDING TO THE PLAT W.- Knox. Fazpatrick: i, ‘or 7 ; / y Ss THEREOF RECORDED IN VOLUME 1 OF PLATS, PAGE 135. Architect & Associates SS 7 é e = * oe. Wood Creek Business Park : i § ‘ " ] EXCEPT THOSE PORTIONS OF SAID LOTS 6, 7, 8, AND 9, CONVEYED TO THE CITY OF RENTON 12810 NE. 178th Street , re / BY DEEDS RECORDED UNDER RECORDING NOS. 3055297, 3055761 AND 3069040. , ule 20 \ Woodinville, WA 98072 ~ ALSO THAT PORTION OF THE HENRY H. TOBIN DONATION CLAIM MO. 37 IN SECTION 17, ph: (425) 415-0746 | TOWNSHIP23 NORTH, RANGE 5 EAST, WILAMETTE MERIDIAN, RECORDING OF KING COUNTY, fax: (425) 415-0799 WASHINGTON, WHICH LIES EASTERLY OF SAID BLOCK 2 AND THE NORTHERLY PRODUCTION 7 , | THEREOF OF THE PLAT OF THE TOWN OF RENTON, SOUTHERLY OF THE SOUTHERLY SHORE DATE: 11-16-99 E OF CEDAR RIVER AND NORTHERLY OF THE NORTHERLY LINE OF HOUSER WAY AS DEEDED TO | THE CITY OF RENTON BY DEED RECORDED UNDER RECORDING NO. 3069040, RECORDS OF DRAWN BY: JBK KING COUNTY. CHECKED BY: WKF ALSO, THAT PORTION, IF ANY, OF THE BED OF CEDAR RIVER ADJOINING THE ABOVE REVISIONS DESCRIBED PORTION OF SAID DONATION CLAIM, WHICH LIES BETWEEN THE SOUTHERLY SHORE Ss: . OF SAID STREAM AND THE MEANDER LINE OF SAID DONATION CLAIM, EXCEPTING THEREFROM DATE} DESCRIPTION | INITIAL GAT BORTON oF SAID RIVER BED, IF ANY, LYING WITHIN THE RIGHT—OF—WAY COMMERCIAL CBE E ET orl ates N-2-WIFINAL CD’ S|JBK SITUATED IN THE COUNTY OF KING, STATE OF WASHINGTON. 12-7-9JREV. FINAL CD'S} JFO SITE NUMBER: SE-2503-A OLD RENTON T.H.. 200 MILL AVENUE S. |. RENTON, WA. 98055 >. 2, Sag Beye | al " — | as ARCHITECTURAL SITE PLAN 24"x36” SCALE: 1”=40’—0” 11"x17” SCALE: 1”=80’—0” | NEW EQUIPMENT LOADSPREADER PLATFORM AND VISUAL SCREENING, a & TO MATCH EXISTING BUILDING. i & INTRATALK EQUIPMENT RACKS . WITH BATTERY BACK-UP UNIT (BBU) —PROVIDED BY VPCS. a > FUTURE INTRATALK EQUIPMENT RACKS ak (PROVIDED BY VPCS). a [ sa aad c Eten Caxias hae a eS aoe Bae ac nce ee ee ee Bae eee on ROO OF TEL EULDING: SEE DETALS SHEET OA at g el Y Y al , Y i x= C3 ae /) OL EAM A aS £3 ei > 6’-0" HIGH GALVANIZED CHAIN LINK FABRIC FENCE Zz % (E] COLUMN a “a ! } H 8’-0" POST TO POST TYPICAL. @ (BEYOND — TYP.) ed 4 : o a meee Set me ee a ree en Pe a, = A = a ra | CI 1) # <> PCS ANTENNAS — PROVIDED BY VPCS. << 3 ‘ 4 SEE SCHEDULE -— SHEET e-1. ae 4 : ‘ PROVIDE CLEARANCE © [Ef] WA | L PLUMBING VALVES AND MBITER re : ip gees oe ee o <> ROOF PENETRATION DOGHOUSE . Z ew ; SEE DETAIL ON SHEET 13/a-4. ee : ‘ i: || Pog 1 iY = [E] WALL TO BE qq Be, i Y O ee REMOVED 22S pee es y « é Zz. = eee | Ss ae aoe meno} i oe i Y ie Onna i | 4 ts Cael ae * Y ELECTRICAL EQUIPMENT STANDARD — SEE SHEET e—1 FOR DETAILS. oO | | z 00 . : 21 < Xe | \ : 24x24” INTERCONNECT PANEL ANTENNA — PROVIDED BY VPCS. fe>) : | i omme : oa eae =| | . | (TYP) Cp , : . 7 ee | tae ee & Fh > igri BLOCKS AND CABLE TRAY COVER | | isEsED = i oF : e 4) A geese meet, ee tla enn Vrewlge aslid i ne deg She NA f} nT BS A } g 2 idee bt 1) bi |__ NX S ox Fre, 1 y ; SITE NOTES es c se naa e eur v ‘ : l40°-0" > y, 1. VERIFY AZIMUTH WITH FINAL SITE —. /- oh | si PROPOSED ANTENNA ARRAY CONFIGURATION SHEET FROM R.F. ENGINEER. (BY OTHER CARRIER) és 9. toe ere . PROPOSED SPRINT FENCED Wand teach. Bupha Park EQUIPMENT COMPOUND 12810 NE. 178th Street Suite 230 8 Woodinville, WA 98072 ph: (425) 415-0746 | fax: (425) 415-0799 [E] iy VENT [os ag = LLL | DATE: 11-16-99 2 Mf ftA “ay [E] 4’x8’ FLOOR Z DRAWN BY: JBK | Be Se ena ee =-—--1 . Ca y ACCESS PANEL 4 CHECKED BY: WKF to Y . : g REVISIONS [E] RAISED a a Z DATE] DESCRIPTION | INTIAL PLATFORM . 1-1-9/PRELIM CD’S|JBK & io fa Z MIFINAL CO’S|JBK wea oi DI Le YffA 12-7-9REV. FINAL CD’S|JFO a Ld 9 O J t+ - u u a) LI LJ LJ : : LJ LI LJ LI L] LJ J Ul LJ 2 SITE NUMBER OLD RENTON T.H.— | 200 MILL AVENUE S. RENTON, WA. 98055 — LAN = WEST HALF = “MECH FLOOR PLAN — WEST HALF Toon i QaeNSB™: SCALE: 3/16" =. : 24"x36" SCALE: 3/16"=1' | Ea: SCALE: 3/32"=1' ; : 3 pests | 11°x17” SCALE: 3/32”=1' a | 6 CONSTRUCTION PLAN KEYED NOTES S| 12 3 2) 3 O} & INTRATALK EQUIPMENT RACKS Fags = ROOF 4a 1 a “Tr | | oy WITH BATTERY BACK-UP UNIT (BBU) —PROVIDED BY VPCS. im 5 oe ee 5 31.60 VARIES aia a oh re Hej ie T_T 1 |p| A | | FUTURE INTRATALK EQUIPMENT RACKS sees ee: : i : > (PROVIDED BY VPCS). wy mek ’ ; i ‘ Lu g\MECH. ROOM rain BS : | 119.00" ti ~ 5] ’ — eed Ez NEW ANTENNA SUPPORT STRUCTURE (PROVIDED BY VPCS) e) E Sie Se aS | SESE | PRR | RE | Me | Ree ye | ae | ee |S | a | a | ee | es © SKID MOUNTED ON ROOF OF [E] BUILDING. SEE DETAILS SHEET a-4 wy (ea) RA. : SIXTH FLOOR iy se ae (up A TL a en, ae | 107.001" | Pe eee e He EHH — ees ‘ : eg» PEsak 4 Pt | PY | SS | ARSE | | ee | See | AS | Bes Son § ea | Bee mes ase | ac | ee | a me | a ia | Pen ane es | Ga Hes ek FITH FLOOR ene ~S 7 FOURTH FLOOR |e ||| Ot oO HESAEeSeee BS ae iso IW Z2a6 eo FREQUENCY:1850-—1990 MHz ARE Ee & WEIGHT: 18.4 LBS. 3 THIRD FLOOR sie) |S 1 HA | | | | ss Cs | Oe ac foes, | Due ema | Bs goa | oes aes | | mee | | eae | | my PCS ANTENNAS — PROVIDED BY VPCS. < WIND SURVIVAL: 125 MPH ~ 71.00" 4 UY Pe ey eee eae a ARITA AR SEE SCHEDULE - SHEET e-1. ae é “ U U U U U U U U U U u U U U U U U j : i I wv - tJ 3 : " ra ANTENNA DETAIL SECOND FLOOR IANA A w oe ~ 94"%36" SCALE: 1/2°=1'-0" 7 sie | | se re ete j ” ” y ” ’ ” : LH cof caeen yee 11x17” SCALE: 1/4”=1'-0O — ae Bere eS Pde r aca sae cae s FIRST FLOOR S Ll 0 | oe % 3 & Bp a fe ate egg ae Teams rc eps Son nd Seen << POLICE FLOOR ; “ N a RECTIFIER ie ac — = Oh os ros RACKS. cS “RADIO. eee ee RADIO ee | 24"x24” INTERCONNECT PANEL ae. gest na = Masta) anions wr ee aS) See ae on pie Oo rec Et Ups tS Tae Naat ROWA = EQUIP. EQUIP. Fair ona ig Dt a auatag NS nee RACKS RACKS he a | | (EXPANSION) | RaGISTENED Sg EAST ELEVATION 3 WEST ELEVATION ny VA ac. Sere gh MRSS re Citas MAR drt aor an animes aati 24x36" SCALE: 3/32” =1'—0” 5 24"x36” SCALE: 3/32” =1'—0” 5 WA ee ai es ey 11°x17” SCALE: Aye 4ran ‘6° 11°x17" SCALE: 3/64”=1'—0" Dak = S S SYMBOLS & ABBREVIATIONS ‘gave cf 12> - (9 (> — T— TELEPHONE SoS oe : oS G— GROUND WIRE kok ee ees eye es cao ————— COAXIAL CABLE W. Knox Fit tick eed eee oe Ee | 70.2” ib | Bee pe ; Bae : # : a ROOF () ds ANTENNA Wood Creek Business Park ; a tte 6 31.60" VARIES A1 ANTENNA MARK NO. bate eo eat Woodinville, WA 98072 3 : uct ROOM ¢ CENTERLINE ph: (425) 415-0746. EQUIPMENT ELEVATION 4 , 119,00 [E] EXISTING fax: (425) 415-0799 2 Tina” SCALE: ert Zo" E SOU Ayent FLOOR [N] NEW DATE: 11-16-99 oa 2'-0 3/8" 4 107.001" W/ WITH DRAWN BY: JDK % aay pee sre | | |Get S| Laas CHECKED BY: WKF S Bx tw cd Ets DETAIL NUMBER REVISIONS oS eg RECTIFIER é a XJ SHEET NUMBER DATE! DESCRIPTION _| INTIAL ae ; 7 = ee ea, See ee eit a FOURTH FLOOR ‘ 2 Be. 3 z oa ei Pe eee kale 83.00° V.LF. VERIFY IN FIELD N-6-9/PRELIM CD'S|JBK | : a e: “is ‘ona | war | age | ser © sem | gps Ogg: | ean | atic" omc | RES} tes | emren dea | Amen 4 at | come} once | ee NW-2-WIFINAL CD’S|JBK | ge Ss | Pach ae | | SS |S | | | | | | A Ay FLOOR Be : , | ae . ¥___[E] WALL (OR OTHER OBSTRUCTION) Poe woe eee a ee 71.00 )2-PIREN. « FAL ee Coa SECOND FLOOR WwW WwW Wy 58.00" | : LAY gi TLRS SITE NUMBER | K } | FIRST FLOOR SP a 4 OLD RENTON T.H. | ‘ ge POLICE FLOOR fs i : 33.00° 200 MILL AVENUE S. RENTON, WA. 98055 (ee BaSSB" SCALE. 3/49" st'—0" , 7 24"x36” SCALE: 3/32” =1'—0” { a x17" SCALE: 3/64"=1'—-0 | 11°x17” SCALE: 3/64”=1'—0 i, J et WA._9801 se idan ode» - NCE NOTES; BATTERY CABINET SPECIFICATIONS } e @ evo OR CORNER POST, 2 1/2"6 STD. PPE , : . @ une Post, 2° sto. PRE ee e-0" . HEIGHT 57.5 in (1460mm) fi © TENSION BAR, 1/4713/4" " oe: TP. —_e WIDTH 30.3 in (770mm) ; ‘ ; : ro CUT MUSHROOM CATCH TO | Ox sen. ss ro w/mex % . | S RS dl sper ae St AC ee Sis e 3” LENGTH & EPOXY INTO ee wet On : RS MAXIMUM WEIGHT 880 Ib (400 KG) =v # be Se Peels * 18 GA GALV. CAP & BASE CORE CUT HOLE IN ANCHOR ENDS & GATE POSTS. [es oo ae ES. 6 ip spc Gi PPR IRN ER rel FLASHING CONSTRUCTED TO eee © 1 1/48 S10, PPE TO RAL : ‘l Ths fasisblainc : ee = eae W/18 FORM BOX. SOLDER ALLS SEAMS | 1 meNS WRUN FOR PE © reson wre 6 A cay, EO | l@/ ses eee ee eve 440 Ib (200 kg) Ps|| OR 15/8. CABLE W/36" ~~ /4” THICK NEOPRENE ee eee csiea O11 O55 sls Ox @ AR “naka ey ; s Bid 1/8°x3/4" STRETCHER BANDS @ 12" 0c. [IS p Tr MIN. | fo Se 3 BS Sk MAX, POWER (240V ) | = RCTS BIN "MIRCOFLECT” WAVE GUIDE ENTRY Ld Not USED gre fe OO) ed Rs NORMAL POWER <I CLS oe oa OS BETS #8576 NOT USED : MAIN CIRCUIT PROTECTION iy : 1 (© NO. 9 GA TE wRE © 14° MAX. HEAT DISSIPATION e) e ie (D) 7° MESH x NO. 9 GA GAY. NORMAL HEAT DISSIPATION 2 5 ae ‘ CHAIN LINK FABRIC. < Sa OPERATING TEMPERATURE Pe : . Pe ee MUSHROOM CENTER STOP) ) |orwmmean FENCE DETAIL 4 oh “ee NOT TO SCALE ANCHORS, & ENDS. NOT TO SCALE 1 5 MAXIMUM OPERATING 4 : < Bees ROOFING 6’ HIGH GATE / FENCE NOTES: —. OF ACOUSTIC NOISE = REMOVE ALL GRAVEL & DEBRIS seb | PRIOR TO APPLICATION OF ROOF Fer SO ee GROUND CABLE a rit rut ae pons ee |_TOP RAIL Tie i 2. CA Lam Brana ANTENNA CONNECTORS er iiegnt QOS a : CABINET OUTPUT i rit v4 tit | ae ’ | 22 GA. GALVANIZED STEEL CAP NAIL TREATED 2"x6" TO 6x4” — : —_ RECEIVE SENSITIVITY ae Siu Fee FLASHING OVER ROOFED IN W/12"8 NAILS © 6” O.C . 5 UT recerererererere,§| 5 jebe FABRIC. 9—GUAGE O itt tt | ae CONTINUOUS BENEATH FLASHING STAGGERED. pe iy TH Hy SET MESH OUTPUT POWER AT CABINET “ : | / RIBS ANTENNA CONNECTOR (H2D ct | ! | | ! SEAL PENETRATIONS WITH : KER | eee eseseer aan x oY ~ Sateaeyig Fs tai Lab Wt : "oy7" | Hl Reve. Vere eee a STRETCHER BAR s 3 fH H i H ! APPROVED ONE HOUR FIRE EPOXY ANCHOR IN’ CONCRETE dlc Se “4 rsacons we eceseee | piselaes nek pe hours of battery backup is provided for full TRX operation. . O os How | :HHt STOP. MATERIAL ; SLAB (3 1/2" EMBED) e\= Saal | vetatates Caterers Meestatel Catatets Lin “ores An additional 0.5 hours is provided for the BCF without oom , aie i WI : CANT ae Hl] oSeseceronscoceces 11H] teectee ea etetete [I see : - eee foe , gare esp | Hessen cecertanees |] fl Neecesr steer tatees IIH hee TRX. operation. S Tt tw La 4 Weees donetonarenes Meee doneease ces Ne _— es. 2. Maximum is defined as batteries charging and heaters active. m™ ei ru a PRL Ue Cera et, Auxilliary 110V outlet power must be added to this figure. oO fe re ae ee NOTE: PAINT ALL EXPOSED SURFACES s 4 ~ eed f ne Ni 3. Normal is defined as batteries not charging and heaters 00 put pnd ys ve a 3 Ht En CORE DRILL CONCRETE DECK PROVIDE : Vit | buut ONE HOUR RATED PENETRATION SLEEVE CALMED 'STER. ; NOTE: REFER TO SHEET 3 thd thw — SEE DETAIL 7/a—4 Sore) MS : a" ROOF PENETR TI a D 3 Wray Sp he To Ase FOR EQUIPMENT DETAILS te 24°x36" SCALE: 1 1/2°=1'—0" 1 NOT TO SCALE 1 0 Q . \/ MA ENATAIART - 3 ee any | y tina pa? NOT TO SCALE , iY He ; oak ee aie oa VASHIN On| | ee ay Pa ee ieee NOTE; NUMBER OF COAXIAL CABLES VARIES BTS CABI N ET SPECIFICATIONS e- ata ia EXISTING WALL SHEET e-1 FOR MODEL # TYP. APPLICATION IS ONE COAX. PER —— ee ti ae 3 | a ee ; cue eee En ALL SAWCUTS TO BE TREATED : , yr UV NUY ay SEALAN CELL FRAME ROOF MOUNT HEIGHT 57.5 in (1460mm) | 57.5 in (1460mm) fe, " ° oy | “ ; GROUND AT EACH CONNECTION WIDTH 30.3 in (770mm) | 30.3 in (770mm) | - NEW COAX CABLE Ps i y ee (WEATHERSEALED) ET ae: DEPTH 42.3 in (1150mm) | 42.3 in (1150mm) pee a — S 7 ee MAXIMUM WEIGHT 760 Ib (345 kg) | 760 Ib (345 kg) Wood Creek Business Park : se WEIGHT w/o BATTERIES 12810 cigs Street NEW THREADED GALVANIZED TREATED 6x6 S , PIPE INSERTED THRU HOLE : ROOFED OVER, SREFER EMPTY WEIGHT 495 Ib (225 kg) | 495 Ib (225 kg) Woodinville, WA 98072 : DRILLED THRU EXISTING WALL. | , VE VOLTAGE 187-222V AC 207-264V AC ph: (425) 415-0746 | eee oe eee <— ee 60 Hz 60 Hz “fax: (425) 415-0799 | AS SHOWN. CONTRACTOR TO 2 ie DETERMINE SIZE OF PIPE AND MAX. POWER a ) 2500 W 2500 W SME. 71 cisese : i ee msi SECTION | ee GUARD AY BOTH ENDS 10-2" ae DRAWN BY: JBK | m N \ és NOTE: INSTALL ANTENNA MOUNTS ELEVATION Sadie Fa gh MAX, HEAT DISSIPATION CHECKED BY: WKF ee AS PER MANUFACTURER'S RECOMMENDATIONS. TO ANTENNA NORMAL HEAT DISSIPATION REVISIONS OPERATING TEMPERATURE —27T° to 122° F | -27° to 122° F ANTENNA SUPPORT g ANTENNA SUPPORT 7 COAX SUPPORT BLOCKS (38 to 50" Cc) | (33 to 50" ©) wel cekcnienbe mad : NOT TO SCALE NOT TO SCALE NOT TO SCALE 5 TEMPERATURE VARIATION : IH6e-SIPRELIM CD’S|JBK cohen a OPERATING 95% 95% is N-2-WIFINAL CD’S|JBK sie ee (3) 1/26 THREADED RODS EA. y 18.7 P FULL OPERATING , 1 hrs 1 hrs MTS. FRAME SIDE, EMBED 2 1/2” INOT | 1 BATTERY BACKUP 2-7-9|REV. FINAL CD’S| JFO EXIST. CONC. FLOOR SLAB AND NEW BTS EQUIPMENT ADDITIONAL PARTIAL OPERATING ci Nene (4) LS. 3/8"@x3" ATTACH W/ HILTI HY 150 eg fas Past | Wa Po INJECTION ADHESIVE ANCHOR s MC 6x15.1 FRAME 10’-0” dB cella = , eR [E] SHEATHING oe ye EXTERNAL T1 CABLE * Multiple Lengths | None : “x LONG x 18.7. WIDE ; ' @ + EXTERNAL ALARM CABLE 25 Pin Connector | Use Main Cabinet SITE NUMBER 2 Es * , ae EXIST. 3” CONC. SLAB POWER CABLE 6B AWG 6 AWG eae ae | | | GROUND CABLE 1/0 AWG 170 AWG SE-2503-—A ae oe : : ANCHORING HOLE. DIA. 0.55 in (14 mm) | 0.55 in (14 mm) OLD RENTON T wot Ba a Ee 1/2" THREADED ROD EMBEDDED 2 1/2” INTO EXISTING CONCRETE ; er _ SY Eee MES Ce FUSES WITHIN CABINET 15 A 15A | eae ; CONCRETE ROOF SLAB AND ADHERED W/ HILT) —s- ROOF. SLAB ; g ANTENNA CONNECTORS Coaxial, Female | Coaxial, Female 200 MILL AVENUE S. | 12x12x3/8 — |HY 150 INJECTION ADHESIVE ANCHOR nee oe . N=type N-type eee NOTES os: NOTES: RENTON, WA. 98055. = ALL PARTS TO BE GALVANIZED . << :; eee 3 : : - i 15h f battery backup ided for full TRX tion. An , ne * so a ighee | TACK WELD INSTALLATION TO cane ; 4 additional 05 pours is feos d for the BCF without TRX pendon | gas Pico eee a ay es Faber SS is no ae Orie a ke ag bey is Rios as a oan oh pene? active. = “A BAGEL. CENCE SRATE 4 eee ara croc —T At aa uxilliary outlet power must be added to this figure. - ee © BASE Fel ICE. é GATE POST A SLE EPER D ETAIL EQU IPMENT DETAI o 3. Normal is defined as batteries not charging and heaters not active. ry hie de, OMe oo ge 4A eae ALES 8 as bey - : / 24°x36" SCALE: 3/4°=1'—0” 5 X36. "= 1'—0" | te a SS eee ages ea oe Le aa 24°x36" SCALE: 3/4°=1/-07 | 24°x36" SCALE: 1/2°=1'—-0 . Peal ee a Ft, * a {2"=1'-0"} 11°17" SCALE: 3/8"=1'—0" ; 11°x17” SCALE: ara yao" | ey ENT PLANNIIOS 2 ote Fi | SINVES "4D OES OF RENTON ip Ae ee a : wi Ss +c ra eines 5s Speas” Be ANTENNA AND COAXIAL CABLE SCHEDULE COAXIAL CABLE IDENTIFICATION GROUNDING KEYED NOTES 3 | Oger ee Oke Oe ee | | 9 NOTE! b> ad USE ANTI~CORROSION GREASE ? Shag Dee eed Gee ‘ 2 oO) : ANTENNA MARK SECTOR : ANTENNA ay AGL CABLE LENGTH (+/ —) AZIMUTH COAX SIZE A. To provide easy identification and uniform marking of antenna ae Ry ae NEW COAXIAL GROUND KITS W/ LONG BARREL : et PE aa ! : cabling, the following shall apply WM < -\, COMPRESSION LUGS, ATTACH TO SRCUNG BAR er ALPHA | PCSAOQ65—13-0 | 105 FEET | +50 FEET 40" 7/8” ree MAIN GROUND CONNECTION POINT. 7 Se ee soa aa WPE-G) Sneath : A2 ALPHA PCSSO65-—13-0 | 105 FEET +50 FEET 40° 7/8" 1. LOCATION: Markings shall be made by use of 3M colored, 2—inch w ea A NEW 4% 24% 1/4" thk COPPER | BPE os BETA __|_ PCSAO90—13-0 | 105 FEET +50 FEET. 180° 7/8” ee affixed at typically four places on the coax cable run as <> BOND ANTENNA SUPPORT & ANTENAA COAX VIA BUS BAR TO 7, ae Abe. GROUND BAR. SUPPLIED AND es. 2 he -} BEIA’ PCSAO90—13-—0 | 105 FEET +50 FEET 180° 7/8” : CONTINUOUS #2 WIRE TO MGB. eg ae ae fuses haanecgarnald ear haste el Basen C1 CHARLIE | PCSAO90-13—-0 | 105 FEET +50 FEET 270° 7/8” bist oj location is Fy the coax at the sit reas nearest the antenna uy a sf : ° C2 CHARLIE PCSAO90—13-0 | 105 FEET £50 FEET 270° 7/8” eee eee. See: OTR. CONNRE YEN, ead Dae Eres £ <> GROUND FROM INTERNAL BTS GROUND BAR TO MGB. a | 5 ae C0000000 0200 ) mea i Sone cutee tw FS. structure. (For towers only). nD Ae * 68,9090 00 Mer TO he 7 a e | ik Lele eee Satine t & Eee NOTE: REFER TO “FINAL” SITE CONFIGURATION SHEET AND/OR CONDITIONAL USE PERMIT APPROVAL AND Fourth — at connection point inside BTS. <> RUN 500MCM GROUND WIRE TO BUILDING STEEL. + x 24" {Tol} PONTTONS E. ete oeee Ehay, 1 CORTE ICTON. 2. SECTOR Identification. Normally o site will hove up to three & i ee FIELD VERIFY > X 7 **DO NOT USE COAXIAL CABLE LENGTHS FOR CUT LENGHTS; FOR ESTIMATES ONLY, oan Sectors sip ee Pegs i vs set cules a in a ‘ 5 es clockwise manner: the first sector is the one closest to zero degrees ae ¥ SCPE GL Ss R : PROPRIETARY INFORMATION (North), the second and third follow clockwise in sequence. <> MASTER GROUND BUSS BAR (MGB). er > ag MASTER "GROUND BA THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR Sector #1 coax will have one bond of a red colored tape for the > . NOT TO SCALE 6 DISCLOSURE OTHER THAN THAT WHICH RELATES TO WESTERN PCS Il CORP. SERVICES IS STRICTLY PROHIBITED. principal coax run and 2 red for the diversity coax run. Normally » #2/ 0 GROUND WIRE FROM “GROUND. HALO a sites will initially go on the air with as few as two antennas per = sector and as the system grows, an additional two antennas will be G9. OO. added. cae oO Pat = eae ate Lee =, Sector #2 coax will have es band of green colored tape for the Ps principal coax and 2 green for the diversity coax. DOUBLE BOLT MECHANICAL / - SCH NINES Sector #3 coax will have one band of blue colored tape for the x _4 4 P principal coax and 2 blue for the diversity coax. ie 2 TO SURGE a 2 SpPRESSON ) TYPE TA STE SS TYPE GR 3. For more than one antenna per site the following will be adhered Y #2 TO TELCO GROUND to: Facing the back of the antenna, starting from your left antenna, © C2638. 0. OO. OD 6 mark it with one band, moving right on the same sector to the next Pesloes) ¢, seen. fo antenna, mark it with two bands of colored tape. Continue with the Bee ses : ree sige tsaim s NOTE: -CADWELD “TYPES” SHOWN ABOVE ARE EXAMPLES — CONSULT WITH PROJECT MANAGER FOR SPECIFIC =~ iia Gace Oe - TYPES OF CADWELDS TO BE USED FOR THIS PROJECT. ts POWER CO. GROUND es 4. In addition to the colored tape apply permanent markings as GROU N DING NOTES & LEGEN D S af follows: ae 1 inch brass round tags marked with Principal 1 (P1), Principal 2 GENERAL GROUNDING NOTES me ; (P2), Principal 3 (P3), Diversity 1 (D1), Diversity 2 (D2), and Diversity fo) O20) O60. 0 O56 9 0 3 (D3) to be attached by a fourteen (14) gouge black electrical wire. 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION 0 Or MASTER BUSS BAR O AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. re) Bk QO eS Os On ® eee o shi tas f (TO. GROUND saa 2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER Monee - #2 (P80) TYPE GT ae a Ere XA TYPE GL LUG METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO : | he COMBECT AT’ GROUNG OOS SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS | MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS. : 7207 GROUNDING SCHEMATIC 5 CADWELD 2h 4 GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR % : , POLE USING MFR’S PRACTICES. ] TIE INTO EXISTING 60 AMP SUB FED . W ee pl Re te NOTE: : SWEEP TEST PROCEDURE 3. ALL GROUND CONNECTIONS SHALL BE CADWELD. ALL WIRES SHALL Winox Frat 4 : WASHI vg ate IF SURGE SUPPRESSER IS AN EXTERIOR MOUNT, RUN | PCS 1900 ANTENNAS AND FEEDERS BE COPPER THHN/THWN. ALL GROUND WIRE SHALL BE GREEN =e TENANT CHECK METER A #2 CU GROUND WIRE IN A 1” SCHED 40 PVC re INSULATED WIRE ABOVE GROUND. Be 3 M #V204 BASE & METER CONDUIT TO SIDE SPLICE CADWELD @ GROUND RING. eS re ee ee ee eS : OR EQUAL HEAT RADIUS CONDUIT TO PRODUCE LARGE RADIUS Aecae 4. CONTRACTOR TO VERIFY AND TEST GROUND: TO SOURCE TO A e b | a nee 2 a BO AVON REG: UT NER. AU BENDS. STRAP TO SLAB AT 2 POINTS (MIN). Test equipment should consist of a sweep oscillator set to run MAXIMUM OF 5 OHMS. IF THE GROUND TEST DID NOT ACHIEVE THE .* a Rec BS dewcairy ‘ond. acclee etek ensues GAR assstion af baliae rc Saba eared Bia Fan Wl Sel OA shel aol cp leg aA it oe W. K Fit : 0.2 d : tee ‘nati PROVIDE ADDITIONAL GROUNDING TO MEET 5 OHM. MAX. nox : th 0.2 dB. A tched 50 Ohm load d short circuit t inati ba hie ‘suseiiaee ore also required. Be ee REQUIREMENT. GROUNDING AND OTHER OPERATIONAL TESTING WILL Paige ay oy by pee ‘ 2.Set up the return loss measuring set as per the manufacturers BE WITNESSED BY THE WESTERN WIRELESS REPRESENTATIVE. 12810 N.E. 178th Street instructions and calibrate with the short (OdB return Loss VSWR = 5 REFER TO DIVISION 16 GENERAL ELECTRIC: GENERAL ELECTRICAL Wood; nig a one: : infinity.) ; invi oe s ey ees ee ames Be oe a PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING oh: (425) 415-0746 a 1 h i a e ite at swee sts are ae pars ¢ - bear te this site pa tee rt eatié, orenviosion to avoid J STANDARDS. fax: (425) 415-0799 : : te ee ee ee 6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF , 100 AMP DIST. . > me =e | lane | PHL W/ MAIN SCALING RANI OO a eas GROUNDING SYSTEM, AND RECEIVE APPROVAL OF DESIGN BY re Se ACT eel 7 Wah oak ae elas ee AUTHORIZED WESTERN WIRELESS REPRESENTATIVE, PRIOR TO DRAWN BY: JBK $472-120-304 : neta loss of the composite jumpers, feeder and antenna should INSTALLATION OF GROUNDING SYSTEM. CHECIEE: Gee ee - . vYZ e ‘ ee ON eo | BER ad tate Ol gL eet Bre ld a a 7. NOTIFY ARCHITECT/ENGINEER IF THERE ARE ANY DIFFICULTIES c EXTENSION BTS CABINETS | REVISIONS 5.Feeder Return Loss: INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. a POWER ONELINE DIAGRAM J : i | | . geno ond Sonne en per ith @ ON N : GROUNDING ROD NOTES | PROPRIETARY INFORMATION id Sora NOT TO SCALE ~ dummy load to the end of the top jumper with a DIN — N adapter. . ee | Power up the N-6-MIPRELIM CD’S|JBK t d the return loss looking into the bott (WHERE APPLICABLE) | : jepes tha reer lem ee ee tre ELECTRICAL CONTRACTOR SHALL ORDER De Ne Soe WeelFINAL co’s|yBK | PITEINA : should not exceed —18dB (VSWR>1.3:1) between 1800 and 2000 a IN THIS SET OF WL MHZ. LAB TEST 10, DETERMINE” GROUND RE CONSTRUCTION DOCUMENTS {S ates P —— ANTENNA SUPPORT _ | OG 6.Feeder Insertion loss: SISTANCE AND REPORT RESULT TO PROPRIETARY BY NATURE. ANY -7-9REV. FINAL CD'S} JFO] a Replace the load with a short circuit termination and measure the WESTERN WIRELESS REPRESENTATIVE. i maximum and USE OR DISCLOSURE OTHER SUPERFLEX JUMPER minimum return loss between 1800 and 2000. Add these together IF RESISTANCE EXCEEDS 5 OHMS, ELEC— THAN THAT WHICH RELATES : and divide by 4 to TRICAL CONTRACTOR SHALL DETERMINE, TO VOICESTREAM PCS II - COAXIAL CABLE — SEE: ANTENNA give the average 1 way insertion loss which should be < 3 dB. leg RESULTS, NUMBER OF RODS CORP. SERVICES IS STRICTLY = = yy ogee Ness ra tate eres 7.1f the conditions in 4,5 and 6 ore met then the test is complete. 3 ; FORMED WHILE GROUND PROHIBITED. SITE: NUMBER —- CADWELD #2/0 STRANDED VM f 4 is hod but 5 & 6 are OK then replace the antenna and retest. TEST SHALL BE. PREFORME L GROUND WIRE TO SUPPORT 5 or 6 are bad then measure RL of main feeder only. If return GRID IS ISOLATED FROM A/C SYSTEM GRD. ride Ct eS og ge Loss improves to —20 or better or insertion loss improves by more SE- 2503- A. —— GROUNDING KIT than 2dB then replace or reterminate the bottom and top jumper. SYM BOL DESCRIPTION erie gs Otherwise replace the main feeder run. Notify Project management OLD RENTON Be H. NOTE: and RF Engineering of any faulty hardware. — CADWELD GROUNDS TO GROUND— yo ith site, PPER GROUND ROD | 200 MILL AVENUE S._ BUS BAR AT EQUIPMENT LOCATIONS. | ali GROUNDING WIRE RUNS AND CONNECTIONS, i eal ee ee eee e Et whic site Gee | fees: BOTH ABOVE AND BELOW GRADE, SHALL BE LOCATED mie petit : Tae NOTE: ; A ~ SADWELD GROUNDING BUS TO INSIDE OF THE LEASE AREA LINE. A CADWELD CONNECTION 4. 4 0 STRANDED GROUNDING WIRE | oA, : ! in L TO WAVE GUIDE BRIDGE &; ? | — . | I? Se ee, t Be Bee ~ SCHEMATIC GROUNDING PLAN 4 ; aL To SoA ome, Aa ee eR ae, NOT _TO SCALE 3 :