Loading...
HomeMy WebLinkAboutBid Plans - Vol II of IICALL 48 HOURS BEFORE YOU DIGONE CALL 1-800-424-5555REPORT ALL SPILLSDEPT. OF ECOLOGY 1-800-258-5990CONTACT INFORMATIONCONTACTCOMPANYPOSITIONPHONEMICHAEL BENOITCITY OF RENTONPROJECT MANAGER(425) 430-7206MARINE BEHRRH2 ENGINEERINGCONSULTANT(425) 439-4008RH2 ENGINEERINGEDWIN HALIM(425) 951-5332CONSULTANTLIFT STATION AND FORCE MAIN IMPROVEMENTSPHASE 3PROJECT NO. WWP-27-4223SUMMER 2023CITY OF RENTONVICINITY MAPMCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-COV.DWGSHOWNCOVCOV73DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:COVERCOVERDISCLAIMER: VICINITY MAP WAS OBTAINEDFROM GOOGLE MAPS ON JUNE 16, 2023CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3KENSINGTON CRESTXLAKE WA BEACH X X X XLIBERTY X XLAKE WA NO. 2XLONGXTALBOT CRESTXX XWEDGEWOODXXTOTAL4738LOCATIONSITEWORKMECHANICALCOATINGREMOVALELECTRICAL/TELEMETRYXXXXXXXLAKE WA BEACHXXXXXXXXLAKE WA NO. 2XXTALBOT CRESTXXXXXXXWESTVIEWCOTTONWOODXXXKENSINGTON CRESTLIBERTYLONGWEDGEWOODLOCATION ADDRESS3000 SE 8TH STLAKE WA BEACHLAKE WA NO. 2TALBOT CRESTWESTVIEWCOTTONWOOD1201 LAKE WASHINGTON BLVD N1201 LAKE WASH16655 SE 136TH ST3903 LAKE WASHINGTON BLVD N3903 LAKE WAS2702 UNION AVE NE2511 TALBOT CREST DR S2511 TALBOT CR5401 NE 10TH ST1149 MONTEREY AVE NE1149 MONTEREY2101 MAPLE VALLEY HWYLIFT STATION ADDRESSESSHEET INDEXSHEET NO.DESCRIPTIONDWG NO.PUGETSOUNDTALBOT CREST LSKENSINGTON CREST LSCOTTONWOOD LSLIBERTY LSWEDGEWOOD LSWESTVIEW LSLAKE WASHINGTON BEACH LSLONGLSLAKE WASHINGTON NO. 2 LSLAKEWASHINGTON MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-G01.DWGSHOWNG001 173DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:VACTOR PIPE IMPROVEMENTS ANDGENERAL DETAILS IAVACTOR SUCTION PIPING AND SUPPORT#5 EPOXY-COATED REBAR WITH4" EMBEDMENT INTO WET WELLWALL OR BOTTOM OF LID AND 4"MIN HEIGHT SHOP-BENT TO 90°BEND OR U SHAPE AS NEEDEDPROVIDE 14" THICK,3" WIDE NEOPRENEPAD BETWEENSTRAP AND PIPE5"2" WIDE, 18" THICKSTAINLESS STEEL PIPESTRAP, BENT TO PROVIDECLEARANCE AS SHOWNØ" ALUMINUM FLAT FLANGE X Ø" HOSEFITTING WITH MOUNTING HOLES.DIAMETER VARIES PER STATION. BOLT TOPVC PIPE. TOP OF FLANGE TO BEINSTALLED APPROX. 3" BELOW BOTTOMOF ACCESS HATCH OR SAFETY GRATING.Ø" PVC PIPE, DIAMETERAND APPROX. LENGTHVARIES PER STATION.VARIESSTAINLESS STEELBOLT, MINIMUM12"DIAMETER, TYP. OF 4NOTES:1. ENSURE THAT PIPE INSTALLATION LOCATIONIS ACCESSIBLE FOR CONNECTION TO VACTORTRUCK WHEN ACCESS HATCH IS OPEN.LOCATION MUST NOT INTERFERE WITH LADDERACCESS.2. PROVIDE ALUMINUM WELD-ON CROWN ATLOWER END OF PVC. BOLT TO PVC.3. ENSURE ALL BOLT HOLES ARE SEALED.3"112"BOLTED CONNECTIONLIFT STATIONPROPOSED VACTORPIPE LENGTHSLIFT STATIONAPPROX. PIPE LENGTH(S)(FT)LAKE WASHINGTON BEACH7.5, 7.5LIBERTY14.5LONG 14.0TALBOT CREST9.5, 12.0WEDGEWOOD9.0, 11.0WESTVIEW14.0KENSINGTON CREST6.0, 6.0COTTONWOOD6.0, 6.0LAKE WASHINGTON NO. 2 19.5CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3LIBERTYWEDGEWOODTALBOT CRESTWESTVIEWLONGLAKE WASHINGTON BEACHDRILL AND EPOXY PIPEREBAR SUPPORTSINTO EXISTING WETWELL, SEE DETAIL ONTHIS SHEETPROPOSED 8" PVC PIPE,SEE TABLE ON THIS SHEETPROPOSED 8" PVC PIPE, TYP. OF2, SEE TABLE ON THIS SHEET.DRILL AND EPOXYPIPE REBARSUPPORTS INTOEXISTING WETWELL, TYP. OF 2.SEE DETAIL ONTHIS SHEETPROPOSED 8" PVC PIPE, SEETABLE ON THIS SHEETDRILL AND EPOXYPIPE REBARSUPPORTS INTOEXISTING WET WELL,SEE DETAIL ON THISSHEETPROPOSED 8" PVCPIPE, TYP. OF 2, SEETABLE ON THIS SHEETDRILL AND EPOXY PIPEREBAR SUPPORTS INTOEXISTING WET WELL,TYP. OF 2, SEE DETAILON THIS SHEETPROPOSED 8" PVC PIPE, TYP. OF 2,SEE TABLE ON THIS SHEETDRILL AND EPOXY PIPEREBAR SUPPORTS INTOEXISTING WET WELL,TYP. OF2, SEE DETAIL ON THIS SHEETKENSINGTON CRESTPROPOSED 8" PVC PIPE, TYP. OF2. SEE TABLE ON THIS SHEETDRILL AND EPOXYPIPE REBARSUPPORTS INTOEXISTING WETWELL, TYP. OF 2.SEE DETAIL ONTHIS SHEETCOTTONWOODPROPOSED 8" PVC PIPE, SEETABLE THIS SHEET. STORE ATLIFT STATION SITE ALONG FENCE.REMOVE HOOK ASNEEDED FORINSTALLATION OFVACTOR STRAWLAKE WASHINGTON NO. 2PROPOSED 6" PVCPIPE, SEE TABLEON THIS SHEETDRILL AND EPOXY PIPEREBAR SUPPORTS INTOEXISTING WET WELL, SEEDETAIL ON THIS SHEETPROPOSED 8" PVCPIPE, SEE TABLEON THIS SHEETDRILL AND EPOXY PIPEREBAR SUPPORTS INTOEXISTING WET WELL, SEEDETAIL ON THIS SHEETNOTE:1. FINAL LOCATION OF VACTOR STRAW(S) TO BECOORDINATED IN THE FIELD WITH OWNER .2. SET VACTOR STRAW(S) BELOW SAFETYGRATINGS. DO NOT DISTURB EXISTING GRATING.VACTOR STRAW LOCATIONSHALL MAINTAIN ACCESSTO VALVE NUTHMA, 3" COMPACTED DEPTH PG 64-22GRAVEL TOP COURSE, 6"COMPACTED DEPTH (MIN.)NATIVE SUBGRADE, TRENCH BACKFILLOR STRUCTURAL BACKFILL. PROOFROLL PRIOR TO GRAVEL PLACEMENT.PAVEMENT SURFACE RESTORATION DETAILNOTE:WHERE ASPHALT PAVEMENTREPAIR IS DIRECTED BY THECITY FOR EXISTING DAMAGEDPAVEMENT, EXISTING PAVEMENTSHALL BE SAW CUT ANDREPLACED WITH COMPACTED PG64-22 ASPHALT, DEPTH PERRESTORATION DETAIL.NON-PAVED SURFACE RESTORATION DETAILHMACONCRETE6" CONCRETE6" CRUSHEDSURFACINGBASE COURSEGRASS SEEDING ORSODDING AS SPECIFIEDNATIVE SUBGRADE, TRENCHBACKFILL OR STRUCTURALBACKFILL. PROOF ROLL PRIOR TOGRAVEL AND TOP SOIL PLACEMENT.COMPACTED GRAVEL TOP COURSE.DEPTH TO MATCH EXISTING, 6" MIN.GRAVEL AREALANDSCAPED AREACOMPACTEDTOP SOIL, 6" MIN. * BEDDINGMATERIAL SHALL NOT BE RECYCLEDCONCRETE.*MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-G01.DWGSHOWNG002273DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:GENERAL DETAILS IICITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3ABBREVIATIONSAPPROXAPPROXIMATELYATSAUTOMATIC TRANSFER SWITCHCBCATCH BASINCLRCLEARANCECMPCORRUGATED METAL PIPECORCITY OF RENTONCPPCORRUGATED POLYETHYLENEDIDUCTILE IRONDIA DIAMETERDWGDRAWINGECOECOLOGYELELEVATIONFCAFLANGED COUPLING ADAPTERFLFLANGEFMFORCE MAINFTFEETHMAHOT MIX ASPHALTIEINVERT ELEVATIONLF LINEAR FEETLSLIFT STATIONMCCMOTOR CONTROL CENTERMHMANHOLEAPPROX.MINIMUMNO. NUMBERO.C.ON CENTEROHPOVERHEAD POWEROPOPERATIONPEPLAIN ENDPVCPOLYVINYL CHLORIDERERIM ELEVATIONREQDREQUIREDRFCARESTRAINED FLANGED COUPLINGADAPTERSSSANITARY SEWERSSFMSANITARY SEWER FORCE MAINSTSTORMSQ. FT.SQUARE FEETTBM TEMPORARY BENCHMARKTP TEST PITTYP. TYPICALVERTVERTICALW/WITHLAKE WASHINGTON BEACHWETWELL COATING REMOVALTALBOT CREST WETWELL COATING REMOVALREMOVE EXISTING COATING WITHIN THEOPERATING BAND AROUND THE FULLCIRCUMFERENCE OF THE WET WELL, ANDTAKE MEASURES TO PROTECT ALLAPPURTENANCES, APPROX 150 SQ. FT.REMOVE EXISTING PEELING COATINGBETWEEN THE BANDS SHOWN AROUNDTHE FULL CIRCUMFERENCE OF THE WETWELL ABOVE THE LANDING AND IN ALLOTHER LOCATIONS WHERE THE EXISTINGCOATING IS PEELING, AND TAKEMEASURES TO PROTECT ALLAPPURTENANCES, APPROX. 200 SQ. FT.KENSINGTON CRESTWETWELL COATING REMOVALREMOVE EXISTING COATING WITHIN THEOPERATING BAND AROUND THE FULLCIRCUMFERENCE OF THE WET WELL, ANDTAKE MEASURES TO PROTECT ALLAPPURTENANCES, APPROX 200 SQ. FT.TYPE A - FLANGE SUPPORTTYPE C - SADDLE CLAMP SUPPORTPIPE SUPPORT DETAIL1" MIN.PIPE STANCHION DETAILPIPE STANCHION BASE PLATE,SIZE AS REQUIRED.PIPE STANCHION,SIZE AS REQUIRED CONCRETE ANCHOR, SIZEAND QUANTITY ASREQUIRED BY THEMANUFACTURERLEVELING NUT, TYP.GROUT AFTERLEVELINGFINISHEDFLOORNOTES:xCONTRACTOR SHALL PROVIDE SUPPORTS AS NEEDED TO SECUREPIPING SYSTEM IN NORMAL AND TEST OPERATING CONDITIONS.CONTRACTOR IS RESPONSIBLE FOR DESIGN OF THE NECESSARYPIPE SUPPORTS, HANGERS AND SEISMIC BRACING. SEESPECIFICATIONS FOR ADDITIONAL INFORMATION. SUBMIT DESIGNWITH PIPING PLAN.xSADDLE AND SADDLE CLAMP SUPPORTS SHALL BE "STANDON" BRANDAS MANUFACTURED BY MATERIAL RESOURCES OR EQUAL. BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-GEN-E01.DWGSHOWNE001 373DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:ELECTRICAL LEGENDCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3GENERAL NOTESGENERAL NOTESLADDER LOGIC SYMBOL LEGENDLADDER LOGIC SYMBOL LEGENDINSTRUMENT METERINSTRUMINDICATE TYPE BYTE TYPE BYLETTERVALVE SYMBOLSVALVE SYMBOLSABBREVIATIONSABBREVIATIONSONE-LINE DIAGRAM SYMBOLSE-LINE DIAGRAM SYMBOLLIGHTING FIXTURES/DEVICESLIGHTING FIXTURES/DEVICESPANELBOARDS, SWITCHES, AND EQUIPMENTLBOARDS, SWITCHES, AND EQUIPMEGROUNDING SYSTEM SYMBOLSOUNDING SYSTEM SYMBOLELECTRICAL SITE PLAN SYMBOLSCTRICAL SITE PLAN SYMBORECEPTACLES AND JUNCTION BOX SYMBOLSCLES AND JUNCTION BOX SYMFIRE SYSTEM SYMBOLSFIRE SYSTEM SYMBOLSADDITIONAL SYMBOLSADDITIONAL SYMBOLSRACEWAY LEGENDRACEWAY LEGENDSWITCH OUTLETSSWITCH OUTLETS BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-GEN-E01.DWGSHOWNE002 473DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:ELECTRICAL DETAILSCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 33"3"3""""3333333333333333333"333333333333FINISH SURFACE PER PLANRED ELECTRICAL WARNINGTAPE CENTERED OVER EACHCONDUIT IN TRENCH (TYP)3336" MIN-48" MAX FORPRIMARY SERVICEECONDUITSMINIMUM DEPTH BELOWBOTTOM OF DEEPESTCONDUIT INSTALLED INTRENCH24" MIN (<600V)NATIVE MATERIAL COMPACTEDTO 95% PER ASTM D1557 OR ASREQUIRED PER PLAN6"9"COVER OVERHIGHEST CONDUITIN TRENCHNOTE: BURY DEPTH OF CONDUIT AND HORIZONTAL SPACING SHALLBE CONFIRMED WITH SERVING UTILITY BEFORE CONSTRUCTION.TYPICAL ELECTRICAL TRENCH DETAILELECTRICAL CONDUIT NUMBER ANDSIZE VARY AS PER SITE PLAN. MAINTAIN12" SPACING BETWEEN TELEMETRYCONDUITS AND OTHER CONDUITS.SAND BEDDINGMATERIAL PER WSDOTSPECIFICATION 9-03.132'-0" MIN.4'-0" MAX.1'-0" MIN.1"CONDUIT (TYPICAL).CONTRACTOR SHALL GROUTFILL AROUND CONDUIT FORWATER TIGHTNESS.VAULT LID.6" MINIMUM DRAIN OPENING.PROVIDE GRATE TO COVEROPENING.CABLE RACK(TYPICAL OF 4SIDES). BOLT TOHAND HOLE.6" GRANULAR FILL.5 CUBIC FEET OF DRAINGRAVEL AROUND DRAINAREA.GRADING RING ASREQUIRED (TYPICAL).HAND HOLE DETAILLENGTH VARIESWIDTH VARIESHATCH COVER. HOT DIPPEDGALVANIZED AND H-20RATED.HAND HOLE NAMEPLATECOVER. NAMEPLATE SHALLREAD ELECTRICAL.HANDLE (TYPICAL).LIFTING INSERTS (TYPICAL).12" MIN.OVER LOCKING SCREW(TYPICAL).CONDUIT (TYPICAL).FINISHED GRADE, SURFACERESTORATION PER SITE PLAN.NATIVE BACKFILL COMPACTEDTO 90% ASTM D1557. MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-KEN-C01.DWGSHOWNC101 573DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:KENSINGTON CREST LS EXISTINGSITE PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3EXISTING LIFT STATIONEXISTING SITE PLANPROPOSED PIG PORT INSIDEEXISTING VALVE VAULT, SEEDWG NO. M101EXISTING MOTOR CONTROLCENTERNOTE: REFER TO DIVISION 11 IN THE SPECIFICATIONS FOR CONSTRUCTIONPHASING, BYPASS, AND TRAFFIC CONTROL REQUIREMENTS.EXISTING MANHOLE TO BEUSED DURING BYPASS OFWET WELLEXISTING WETWELLEXISTINGVALVE VAULT MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-KEN-M01.DWGSHOWNM101 673DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:KENSINGTON CREST LS MECHANICALPLANKENSINGTON CREST LIFT STATIONEXISTING VALVE VAULT PLANKENSINGTON CREST LIFT STATIONPROPOSED VALVE VAULT PLANOBLIQUESECTIONEXISTING VALVE VAULTAACITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3ACONNECTINGROD, TYP. OF 84" FCA, TYP. OF 44" CHECK VALVE (FLxFL), TYP. OF 24" GATE VALVE(FLxFL), TYP. OF 34" 45° BEND (FLxFL)4" MAGNETIC FLOWMETER (FLxFL)PROPOSED 4" DITEE (FLxFLxFL)PROPOSED 4" DI 90°BEND (FLxFL)PROPOSED 4" DI SPOOL(FLxFL), LENGTH 1'-0"PROPOSED 4" DI BLINDFLANGE WITH THREADED TAPPROPOSED 2" STAINLESSSTEEL BALL VALVE4" WYE (FLxFLxFL)PIPE SUPPORT, TYP.SUMP PUMPPROPOSED 2" STAINLESS STEELNIPPLE AS REQUIRED, TYP. OF 2PROPOSED 4" ECCENTRICPLUG VALVE W/ HANDWHEEL ACTUATOR (FLxFL)PROPOSED PIGPORT ASSEMBLYLADDERACCESS HATCH OUTLINEREMOVE EXISTING 4"SPOOL (FLxFL)RELOCATE EXISTING SUPPORTRELOCATED PIPESUPPORTPROPOSED 4" DI SPOOL(FLxPE), APPROX. LENGTH 12"PROPOSED 4" EBAA2100 MEGAFLANGE BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-KEN-E02.DWGSHOWNE101 773DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:KENSINGTON CREST LS ELECTRICALPLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3EXISTING TELEMETRY PANEL EXTERIOREXISTING TELEMETRY PANEL INTERIOREXISTING TELEMETRY ENCLOSUREEXISTING TELEMETRY PANEL TO BEREMOVED AND RETURNED TO OWNER.INSTALL PROPOSED TELEMETRY PANELIN SAME LOCATION AS EXISTINGTELEMETRY PANEL WITH STAINLESSSTEEL MOUNTING HARDWARE.EXISTING TELEMETRY POWERENCLOSURE TO BE REMOVED ANDRETURNED TO OWNER. ALL INCOMINGAND OUTGOING CIRCUITS TO BEDISCONNECTED FROM EXISTINGTELEMETRY POWER ENCLOSURE ANDRETERMINATED INSIDE PROPOSEDTELEMETRY PANEL.EXISTING CONDUITS TO BETERMINATED AT PROPOSEDTELEMETRY PANEL, TYPICAL OFALL CONDUITS ENTERINGEXISTING TELEMETRY PANELAND POWER ENCLOSURE.ALL INCOMING AND OUTGOINGCIRCUITS TO BE DISCONNECTEDFROM EXISTING TELEMETRYPANEL AND RETERMINATEDINSIDE PROPOSED TELEMETRYPANEL.1. COORDINATE TELEMETRY PANEL REMOVAL AND NECESSARY SHUTDOWN PERIOD WITH OWNER BEFOREHAND; 5WORKING DAYS NOTICE REQUIRED. SHUTDOWN DURATION SHALL NOT EXCEED 5 CALENDAR DAYS.2. CONTRACTOR SHALL DISCONNECT ALL EXISTING CONDUCTORS AND CONDUITS FROM THE EXISTING TELEMETRYPANEL (RTU) AND REMOVE THE EXISTING RTU FROM ITS LOCATION TO MAKE SPACE FOR INSTALLATION OF THEPROPOSED RTU. EACH EXISTING CONDUCTOR SHALL BE LABELED PRIOR TO DISCONNECTING FROM THE RTU TO AID INTHE INSTALLATION OF THE PROPOSED RTU.3. OWNER SHALL BE PROVIDED OPPORTUNITY TO REMOVE AND RETAIN ANY EQUIPMENT FROM EXISTING TELEMETRYPANEL. CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING OF ALL EQUIPMENT NOT RETAINED BY OWNER.4. CONTRACTOR SHALL REVIEW TELEMETRY PANEL DRAWINGS AND LAND EXISTING AND PROPOSED CONDUCTORS INTELEMETRY PANEL.5. INSTALL PROPOSED RTU IN THE SAME LOCATION AS THE EXISTING RTU AND EXTEND ALL EXISTING CONDUITS TOTHE PROPOSED RTU. CONTRACTOR SHALL MODIFY EXISTING CONDUIT AND INSTALL NEW CONDUIT AS NECESSARY TOREROUTE CONDUIT INTO THE PROPOSED TELEMETRY PANEL BASED ON THE PANEL SIZING.TELEMETRY PANEL INSTALLATION NOTESLEMETRY PANEL INSTALLATION NOTEXISTING PANEL TO BEREMOVED. REPAIR ANDMAKE WEATHERPROOF ALLCONDUIT AND MOUNTINGPENETRATIONS.DISCONNECT EXISTING SIERRAWIRELESS MODEM FROM EXISTINGTELEMETRY PANEL AND RECONNECTTO PROPOSED TELEMETRY PANEL.SEE DWG NO.E103 FOR POWER ANDCOMMUNICATIONS CONNECTIONS. BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-KEN-E04.DWGSHOWNE102 873DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:KENSINGTON CREST LS RTU LAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3RTU PANEL LAYOUTKENSINGTON CREST LIFT STATIONCONTROL PANELOPERATOR INTERFACE.LOCATE OPERATORINTERFACE 5'-0" ABOVEFINISHED GRADE.NAME PLATEWARNING LABELWARNING120 VACKEEP OUTHANDLE1. CONTRACTOR SHALL CONFIRM ALL PANEL DIMENSIONS IN FIELD PRIOR TOFABRICATION DUE TO POTENTIAL INSTALLATION DIFFERENCES AND FIELDCONSTRAINTS.ELECTRICAL NOTESELECTRICAL NOTESNEMA TYPE 4XSTAINLESS STEEL12" DEEP ENCLOSURE BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-KEN-E04.DWGSHOWNE103 973DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:KENSINGTON CREST LS POWER ANDCOMMS LAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3COMPACTLOGIX 5370 L1 PLCMODEL NO. 1769-L18ER-BB1BOPERATOR INTERFACEETHERNET SWITCHCOMMUNICATIONS LAYOUT8 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB84 PT ANALOG INPUT MODULEMODEL NO. 1734-IE4CL44CB120P20A1CBGNDPROTECTORLINE SURGELN120N24VDCPOWER SUPPLY10CBLNN2L10120 VAC 1PH 60HZ20A3CBL3LIGHTL2L55CBSPARE+24P24NPOWER LAYOUTL1N1L2N22CBBATTERYDC OUTDC INUPS24 VDCBATTERYDC OUTDC IN++---CB BATPANEL HEATERN5AC POWER FAILN3N4N10FLOWMETER7CBL7N78CBL8N8COMPACTLOGIX 1769-L18ER12CB24P124VDC TO 24VDCPOWER SUPPLY DC OUTDC INDC OUTDC IN++--ETHERNET SWITCH24P314CBOPERATOR INTERFACE24P415CBSPARE9CBL9N924P213CBDPF CRRDPF CRRCOOLING FANSN6L66CB24P24NEXISTING WIRELESS MODEM24P5PLC INPUTS/OUTPUTS24P6BACKUP FLOATS16CB24P718CB17CBSPARE24P819CBSPARE24P920CBCOMPACTLOGIX 5370 L1 PLC BASE,MODEL NO. 1769-L18ER-BB1BCAT 5E ETHERNET CABLECAT 5E ETHERNET CABLEEXISTINGANTENNACAT 5E ETHERNET CABLEEXISTING COAXIAL CABLEEXISTING SIERRAWIRELESS MODEM(LOCATED OUTSIDERTU ENCLOSURE)11CBD BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-KEN-E04.DWGSHOWNE104 1073DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:KENSINGTON CREST LS INPUT ANDOUTPUT WIRING 1CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, BASE UNITDIGITAL OUTPUTS, BASE UNIT1. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-KEN-E04.DWGSHOWNE105 1173DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:KENSINGTON CREST LS INPUT ANDOUTPUT WIRING 2CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, SLOT 3DIGITAL INPUTS, SLOT 2DIGITAL INPUTS, SLOT 1DIGITAL INPUTS, SLOT 41. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-KEN-E04.DWGSHOWNE106 1273DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:KENSINGTON CREST LS INPUT ANDOUTPUT WIRING 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3ANALOG INPUTS, SLOT 51. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-KEN-E04.DWGSHOWNE107 1373DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:KENSINGTON CREST LS CONTROLLOGICCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3BACK-UP FLOAT AND PUMP CONTROL MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LAWB-C01.DWGSHOWNC201 1473DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON BEACH LSEXISTING & PROPOSED SITE PLANEXISTING SITE CONDITIONS AND DEMOLITION PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3EXISTING SWING ACCESS GATE TOBE REMOVED AND REPLACED, TYP.EXISTING FENCE TOREMAIN, TYP.EXISTING SWING ACCESSGATE TO REMAINEXISTING SWING ACCESS GATEEXISTING SWING ACCESSGATE TO BE REMOVED ANDREPLACED, TYP.EXISTING WET WELLEXISTING VALVEVAULTPROPOSED LIFT STATION IMPROVEMENTSPROPOSED SWING ACCESSGATE, MATCH EXISTINGLOCATION AND DIMENSIONSPROPOSED PIG PORT INSIDEEXISTINGVALVE VAULT, SEE DWGNO. M201REUSE EXISTING LOCK ONPROPOSED GATE.RELOCATE NO PARKINGRGN TO PROPOSED GATESIGNOTE: REFER TO DIVISION 11 IN THE SPECIFICATIONS FOR CONSTRUCTIONPHASING, BYPASS, AND TRAFFIC CONTROL REQUIREMENTS.FORCE MAINDISCHARGE MANHOLEEXISTING MANHOLE FORTEMPORARY STORAGEAND LEVEL MONITORING.EXISTING VALVE TOBE CLOSED DURINGCOATING REMOVALXISTING END POSTS TOEXN, TYP. OF BOTH SIDES.REMAIPROPOSED GATE COMPONENTS SHALL BE HOT DIP GALVANIZED ANDACRYLIC COATED. COLOR SHALL MATCH EXISTING FENCE. COAT CENTERPOST AND END POSTS ADJACENT TO PROPOSED SWING ACCESS GATE.REUSE EXISTINGCENTER POST11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LAWB-M01.DWGSHOWNM201 1573DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON BEACH LSMECHANICAL PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3AALAKE WASHINGTON BEACH LIFT STATION EXISTING VALVE VAULT PLANLAKE WASHINGTON BEACH LIFT STATION PROPOSED VALVE VAULT PLANOBLIQUESECTIONAEXISTING VALVE VAULT4" FCA, TYP. OF 34" CHECK VALVE(FLxFL), TYP. OF 24" PLUG VALVE W/ OPERATIONAL NUT (FLxFL), TYP. OF 34" TEE (FLxFLxFL)4" 90° BEND (FLxFL) REMOVE EXISTING4" SPOOL (FLxPE)SUMP PUMPPROPOSED 4" DI TEE(FLxFLxFL)PROPOSED 4" SPOOL(FLxPE), APPROXLENGTH 1'-6"PROPOSED 4" DI 90°BEND (FLxFL)PROPOSED 4" ECCENTRICPLUG VALVEW/ HAND WHEELACTUATOR (FLxFL)PROPOSED 4" DI SPOOL(FLxFL), LENGTH 1'-0"PROPOSED 4" DI BLINDFLANGE WITH THREADED TAPPROPOSED 2" STAINLESSSTEEL NIPPLE ASREQUIRED, TYP. OF 2PROPOSED 2"STAINLESS STEELBALL VALVEPIPE SUPPORT, TYP.PROPOSED PIGPORT ASSEMBLYLADDERACCESS HATCHOUTLINEREMOVERFCARELOCATED 4" TAPPING SADDLE ANDPRESSURE GAUGE ASSEMBLY. REUSEEXISTING FITTINGS FROM RELOCATEDPRESSURE GAUGE ASSEMBLY WHERELIKE NEW CONDITION AND PROVIDEADDITIONAL MATERIALS ASNECESSARY PER PRESSURE GAUGEASSEMBLY DETAIL THIS SHEET.LOCATE FITTINGS TO NOT CONFLICTWITH PROPOSED PIG PORT ASSEMBLY.PROPOSED ROMAC RFCAOR APPROVED EQUALRELOCATE TAPPINGSADDLE AND PRESSUREGAUGE ASSEMBLYPRESSURE GAUGE ASSEMBLY DETAIL1/2" STAINLESSSTEEL TEE1/2" STAINLESS STEEL 45°BEND. ORIENT SUCH THATGAUGE FACE IS VISIBLE FROMACCESS HATCH ABOVE.1/2" STAINLESS STEELNIPPLE AS REQUIRED,TYP. OF 4.1/2" STAINLESS STEELBALL VALVE, TYP. OF 2.1/2" STAINLESS STEELTHREADED TAP, ORRELOCATED TAPPINGSADDLEPRESSURE GAUGEWITH DIAPHRAGM SEALNOTE: IF MATERIALS FROM EXISTING PRESSURE GAUGEASSEMBLY ARE RELOCATED TO FINAL ASSEMBLY THANPROPOSED COMPONENTS SHALL MATCH EXISTING SIZE.PROPOSED PIPESUPPORT BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LAWB-E03.DWGSHOWNE201 1673DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON BEACH LSELECTRICAL PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3EXISTING TELEMETRY PANEL EXTERIOREXISTING TELEMETRY PANEL INTERIOREXISTING TELEMETRY PANEL TO BEREMOVED AND RETURNED TO OWNER.INSTALL PROPOSED TELEMETRY PANELIN SAME LOCATION AS EXISTINGTELEMETRY PANEL WITH STAINLESSSTEEL MOUNTING HARDWARE.EXISTING TELEMETRY POWERENCLOSURE TO BE REMOVED ANDRETURNED TO OWNER. ALL INCOMINGAND OUTGOING CIRCUITS TO BEDISCONNECTED FROM EXISTINGTELEMETRY POWER ENCLOSURE ANDRETERMINATED INSIDE PROPOSEDTELEMETRY PANEL.EXISTING CONDUITS TO BETERMINATED AT PROPOSEDTELEMETRY PANEL, TYPICAL OFALL CONDUITS ENTERINGEXISTING TELEMETRY PANELAND POWER ENCLOSURE.ALL INCOMING AND OUTGOINGCIRCUITS TO BE DISCONNECTEDFROM EXISTING TELEMETRYPANEL AND RETERMINATEDINSIDE PROPOSED TELEMETRYPANEL.1. COORDINATE TELEMETRY PANEL REMOVAL AND NECESSARY SHUTDOWN PERIOD WITH OWNER BEFOREHAND; 5WORKING DAYS NOTICE REQUIRED. SHUTDOWN DURATION SHALL NOT EXCEED 5 CALENDAR DAYS.2. CONTRACTOR SHALL DISCONNECT ALL EXISTING CONDUCTORS AND CONDUITS FROM THE EXISTING TELEMETRYPANEL (RTU) AND REMOVE THE EXISTING RTU FROM ITS LOCATION TO MAKE SPACE FOR INSTALLATION OF THEPROPOSED RTU. EACH EXISTING CONDUCTOR SHALL BE LABELED PRIOR TO DISCONNECTING FROM THE RTU TO AID INTHE INSTALLATION OF THE PROPOSED RTU.3. OWNER SHALL BE PROVIDED OPPORTUNITY TO REMOVE AND RETAIN ANY EQUIPMENT FROM EXISTING TELEMETRYPANEL. CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING OF ALL EQUIPMENT NOT RETAINED BY OWNER.4. CONTRACTOR SHALL REVIEW TELEMETRY PANEL DRAWINGS AND LAND EXISTING AND PROPOSED CONDUCTORS INTELEMETRY PANEL.5. INSTALL PROPOSED RTU IN THE SAME LOCATION AS THE EXISTING RTU AND EXTEND ALL EXISTING CONDUITS TOTHE PROPOSED RTU. CONTRACTOR SHALL MODIFY EXISTING CONDUIT AND INSTALL NEW CONDUIT AS NECESSARY TOREROUTE CONDUIT INTO THE PROPOSED TELEMETRY PANEL BASED ON THE PANEL SIZING.TELEMETRY PANEL INSTALLATION NOTESLEMETRY PANEL INSTALLATION NOTEREMOVE EXISTING ETHERNETRADIO AND INSTALL INPROPOSED RTU. SEE DWG NO.E203 FOR DETAILS.RECONNECT EXISTINGANTENNA TO PROPOSEDSURGE ARRESTOR USINGEXISTING COAXIAL CABLE.EXTEND EXISTING COAXIALCABLE AS NECESSARY TOREACH PROPOSED SURGEARRESTOR IN PROPOSEDRTU. BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LAWB-E04.DWGSHOWNE202 1773DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON BEACH LS RTULAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3RTU EXTERIOR PANEL DOOR LAYOUTWARNING LABELWARNING120 VACKEEP OUTNAMEPLATEPAD-LOCKABLEHANDLELAKE WASHINGTON BEACH LIFTSTATION CONTROL PANELRTU INTERIOR SWING DOOR LAYOUTPROVIDE RAIN HOOD FORINTAKE VENT AND EXHAUSTFAN, TYP.OPERATOR INTERFACE.LOCATE OPERATORINTERFACE 5'-0" ABOVEFINISHED GRADE.NEMA TYPE 4XSTAINLESS STEEL12" DEEP ENCLOSURE1. CONTRACTOR SHALL CONFIRM ALL PANEL DIMENSIONS IN FIELD PRIOR TOFABRICATION DUE TO POTENTIAL INSTALLATION DIFFERENCES AND FIELDCONSTRAINTS.ELECTRICAL NOTESELECTRICAL NOTESSUN SHADE. SMITH & LOVELESSH87A379 OR EQUAL. BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LAWB-E04.DWGSHOWNE203 1873DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON BEACH LS POWERAND COMMS LAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3COMPACTLOGIX 5370 L1 PLCMODEL NO. 1769-L18ER-BB1BEXISTING ETHERNETRADIOOPERATOR INTERFACEETHERNET SWITCHCOMMUNICATIONS LAYOUTSURGEARRESTOR8 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB84 PT ANALOG INPUT MODULEMODEL NO. 1734-IE4CL44CB120P20A1CBGNDPROTECTORLINE SURGELN120N24VDCPOWER SUPPLY10CBLNN2L10120 VAC 1PH 60HZ20A3CBL3LIGHTL2L55CBSPARE+24P24NPOWER LAYOUTL1N1L2N22CBBATTERYDC OUTDC INUPS24 VDCBATTERYDC OUTDC IN++---CB BATPANEL HEATERN5AC POWER FAILN3N4N10FLOWMETER7CBL7N78CBL8N8COMPACTLOGIX 1769-L18ER24P124VDC TO 24VDCPOWER SUPPLY DC OUTDC INDC OUTDC IN++--ETHERNET SWITCH24P3OPERATOR INTERFACE24P4SPARE9CBL9N924P2EXISTING ANTENNACOOLING FANSN6L66CB24P24NETHERNET RADIO24P5PLC INPUTS/OUTPUTS24P6BACKUP FLOATS24P7SPARE24P8SPARE24P9COMPACTLOGIX 5370 L1 PLC BASE,MODEL NO. 1769-L18ER-BB1BCAT 5E ETHERNET CABLECAT 5E ETHERNET CABLECAT 5E ETHERNET CABLECOAXIAL CABLEEXISTING COAXIAL CABLE12CB14CB15CB13CBDPF CRRDPF CRR16CB18CB17CB19CB20CB11CBD BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LAWB-E04.DWGSHOWNE204 1973DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON BEACH LS INPUTAND OUTPUT WIRING 1CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, BASE UNITDIGITAL OUTPUTS, BASE UNIT1. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LAWB-E04.DWGSHOWNE205 2073DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON BEACH LS INPUTAND OUTPUT WIRING 2CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, SLOT 3DIGITAL INPUTS, SLOT 2DIGITAL INPUTS, SLOT 1DIGITAL INPUTS, SLOT 41. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LAWB-E04.DWGSHOWNE206 2173DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON BEACH LS INPUTAND OUTPUT WIRING 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3ANALOG INPUTS, SLOT 51. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LAWB-E04.DWGSHOWNE207 2273DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON BEACH LSCONTROL LOGICCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3BACK-UP FLOAT AND PUMP CONTROL MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LIB-C01.DWGSHOWNC301 2373DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LIBERTY LS PROPOSED SITE PLAN ICITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3PROPOSED SITE PLANEXISTING WET WELL10' ØRIM = 434.00'IE IN= 421.00'BOTTOM = 416.50'EXISTINGVALVE VAULTEXISTING ELECTRICALSHELTERPROPOSED PIG PORT INSIDE EXISTINGVALVE VAULT, SEE DWG NO. M301PROPOSED FLOW METERMANHOLEN: 177481.65E: 1322459.67PROPOSED (1) - 1" CONDUIT CONTAINING:(6) - #14, (1) - #14GRD(1) - 2-CONDUCTOR SHIELDED CABLEPROPOSED HAND HOLENOTE: REFER TO DIVISION 11 IN THE SPECIFICATIONS FOR CONSTRUCTIONPHASING, BYPASS, AND TRAFFIC CONTROL REQUIREMENTS.WIDTH PER PLANDOUBLE GATE SWING DETAIL4"-6"TUBE GUIDE BASE DETAILEXISTING GATE POSTEACH SIDEPROPOSED TOPHINGE 180° SWINGPROPOSED GATELATCHBOTTOM HINGE180° SWINGPROPOSED TUBEGUIDE BASE,THIS SHEETPROPOSED DOUBLE SWING GATEPROPOSED ROD MUST EXTEND 4"-6" INTOTHE GUIDE TUBE, SEE DETAIL THIS SHEETPROPOSED FENCING RODPROPOSED FENCING GUIDETUBE FOR ROD SUPPLIED BYFENCING MANUFACTURERPROPOSED CONCRETEBASE, 12" Ø, 12" DEEPEXISTING ACCESS GATERESTORE PAVEMENT ANDCONCRETE SURFACE TO EXISTINGOR BETTER CONDITION PERDETAIL ON DWG NO. G001.STRAW WATTLEREMOVE EXISTING SLIDE GATE ANDSEGMENT OFSTRAIGHT FENCEONNORTH SIDE OF SITE. REPLACEWITH PROPOSED DOUBLESWINGGATE, DETAIL THIS SHEET.1222'2APPROX. 10'.CONTRACTOR TO FIELDCVERIFY LENGTH.EXISTING SLIDE GATE TOBE REMOVED6'-0"EXISTINGFOOTINGS,TYP. OF 2PROPOSED 3/8"TIE RODPROPOSED 2-3/8"O.D. GATE POSTSPROPOSED 2-3/8"O.D. TOP RAILPROPOSED 2-3/8" O.D. RAIL, CENTER IN PANEL.PROPOSED 6 GAGE BANDS AT14" O.C.PROPOSED 2-3/8"O.D. BOTTOM RAILSWING GATE PATH, TYP.EXISTING GATE POST, DO NOTDISTURB, TYP. BOTH SIDES.EXISTING POST TOBE REMOVED.EXISTING STRAIGHTSEGMENT OF FENCETO BE REMOVED1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LIB-C02.DWGSHOWNC302 2473DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LIBERTY LS PROPOSED SITE PLAN IICITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3PROPOSED FLOW METER MANHOLE SECTIONPROVIDE 8" DI COUPLING (RJxRJ)ROMAC 501 OR EQUAL WITH ROMAC 611PIPE RESTRAINING SYSTEM, TYP. OF 2.PROPOSED FLOW METER MANHOLE PLANAAAPROPOSED 8" GATEVALVE W/ HAND WHEELACTUATOR (FLxFL)PROPOSED 8" FLOWMETER (FLxFL)12" MINAPPROX. 3.5'CONTRACTOR TOVERIFY DEPTHPROVIDE 12" CRUSHED ROCKCOMPACTED TO A UNIFORMLY DENSEAND UNYIELDING CONDITIONPROPOSED 72" INSIDE DIAMETERSADDLE MANHOLE WITH 6'-0"MINIMUM INSIDE HEIGHT. 6"DIAMETER CORE AT BOTTOM INCENTER OF MANHOLE.LOCATION OF EXISTING 8" FORCEMAIN MATERIAL TRANSITION FROMDI TO PVC IS UNKNOWN, TYP.CUT APPROX. 9'-6" OF PIPE FOR FLOWMETER MANHOLE INSTALLATION ANDINSTALL TRANSITION COUPLINGS,TYP. OF 2.12" MIN,TYP. BOTHSIDES.FILL PIPE PENETRATION WITHCONCRETE, SEE DETAIL THIS SHEET.LW PRODUCTS HHD-2 (42"x42")HATCH OR APPROVED EQUALPROPOSED ACCESS HATCHOUTLINE (4'-0"x4'-4")PROPOSED 8" DI SPOOL(FLxPE), APPROX.LENGTH 3'-2"PROPOSED ACCESSHATCH CLEAR OPENING8" DI WALL RING THRUSTCOLLAR, CENTERED IN BLOCKTYPTYP3/16"7"7" MIN.18"12"NOTES:1. LADDERS SHALL BE ALUMINUM.2. LADDER SHALL MEET CONSTRUCTIONREQUIREMENTS OF ANSI A14.3LADDER DETAILACCESS HATCH LIMITSPLANPROFILEPROVIDE ADDITIONALDIAGONAL/BRACKETS ATTOP CONNECTIONHATCH CURB OPENING58" CONCRETEANCHORS, (TYP.)IN LIEU OF TOP DIAGONAL,EXTEND RAILS AND BEND 3"AT FLOOR. SECURE WITH58"CONCRETE ANCHORSSTRINGERS, FB 2122"X1X2" LADDER RAILS,PUNCH TO RECEIVE RUNGSSST LADDER SAFETY POST, BILCOLADDER-UP OR EQUAL, INSTALLPER MANUFACTURER'SRECOMMENDATIONS.BAR 3",2122"x1x2" BRACKETS T&B, 8'O.C. MAX. VERTICALSPACINGCONCRETEWALL/RISER1" DIA. RUNGS, EQUALLYSPACED VERTICALLY @ 12" O.C.204(2) RINGS OF CONTINUOUS SWELLSTOPBETWEEN WALL AND PIPE BLOCKPIPE PER PLAN#5 CONCRETE ANCHORS EA.CORNER EMBED 3" INTOMANHOLE. HOOK INTO BLOCKPIPE O.D. + 6"MANHOLE(2) RINGS OF CONTINUOUS SWELLSTOPBETWEEN PIPE AND PIPE BLOCK#5 @ 12" O.C. EACH WAYSTRUCTURE INTERIORSTRUCTURE EXTERIOR2" CLR, TYP.NOTES:1.CONCRETE BLOCK SHALL BE PER SECTION 7-09.3(21) OF THE WSDOT STANDARD SPECIFICATIONS.2.MAINTAIN 18" MINIMUM COVER OVER THE TOP OF BLOCK.3.PROVIDE 3" CLEARANCE BETWEEN SWELLSTOP AND EDGE OF BLOCK IN ANY DIRECTION.4. TIGHTLY BUTT COIL SWELLSTOP ENDS TOGETHER TO FORM CONTINOUS WATERSTOP.DI WALL RING6" CLR, TYP.THRUST BLOCKPROPOSED LADDER,SEE DETAIL THIS SHEETMANHOLE THRUST BLOCK,SEE DETAIL THIS SHEET1'-8"10"PROPOSED 8" DI SPOOL (FLxPE),APPROX. LENGTH 4'-4"CLCC1'-3"3" CLR MIN., TYP.PROPOSED 8" DISMANTLINGJOINT (FLxFL)12" DIAMETER OF12"DEEP GRAVELBACKFILL FOR DRAINS, COMPACTED TOA FIRM AND UNYIELDING CONDITION.NOTES: ALL DUCTILE IRON PIPE AND FITTINGSSHALL BE POLYETHYLENE WRAPPED PERANSI/AWWA C105/A21.5-93 STANDARDS.FILL PIPE PENETRATIONWITH NON-SHRINK GROUT.PROPOSED PIPE SUPPORT, TYP. OF2. SEE DETAIL ON DWGN0. G002. MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LIB-M01.DWGSHOWNM301 2573DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LIBERTY LS MECHANICAL PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3LIBERTY LIFT STATION EXISTING VALVE VAULT PLANLIBERTY LIFT STATION PROPOSED VALVE VAULT PLANEXISTING VALVE VAULTOBLIQUESECTIONAAACONNECTING ROD, TYP. OF 46" FCA, TYP. OF 26" PLUG VALVE WITH OPERATIONNUT (FLxFL), TYP. OF 26" CHECK VALVE (FLxFL), TYP. OF 2REMOVE 6" 45° BEND (FLxFL)SUMP PUMPAIR VACUUM ASSEMBLY6"x6"x6" TEE (FLxFLXFL)PROPOSED 6" DITEE (FLxFLxFL)PROPOSED 6" DI90° BEND (FLxFL)PROPOSED 6" DI SPOOL(FLxFL), LENGTH 1'-0"PROPOSED 6" DI BLINDFLANGE WITH THREADEDTAPPROPOSED 2" STAINLESSSTEEL BALL VALVEPIPE SUPPORT,TYP.PROPOSED 2" STAINLESS STEELNIPPLE AS REQUIRED, TYP. OF 2PROPOSED 6" ECCENTRIC PLUGVALVE W/ HAND WHEELACTUATOR (FLxFL)PRESSURE GAUGE, TYP. OF 2PROPOSED PIGPORT ASSEMBLYLADDERACCESS HATCH OUTLINEPROPOSED PIPESUPPORT BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LIB-E03.DWGSHOWNE301 2673DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LIBERTY LS ELECTRICAL PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3EXISTING TELEMETRY PANEL EXTERIOREXISTING TELEMETRY PANEL TO BEREMOVED AND RETURNED TO OWNER.INSTALL PROPOSED TELEMETRY PANELIN SAME LOCATION AS EXISTINGTELEMETRY PANEL WITH STAINLESSSTEEL MOUNTING HARDWARE.EXISTING CONDUITS TO BETERMINATED AT PROPOSEDTELEMETRY PANEL, TYPICAL OFALL CONDUITS ENTERINGEXISTING TELEMETRY PANEL.1. COORDINATE TELEMETRY PANEL REMOVAL AND NECESSARY SHUTDOWN PERIOD WITH OWNER BEFOREHAND; 5WORKING DAYS NOTICE REQUIRED. SHUTDOWN DURATION SHALL NOT EXCEED 5 CALENDAR DAYS.2. CONTRACTOR SHALL DISCONNECT ALL EXISTING CONDUCTORS AND CONDUITS FROM THE EXISTING TELEMETRYPANEL (RTU) AND REMOVE THE EXISTING RTU FROM ITS LOCATION TO MAKE SPACE FOR INSTALLATION OF THEPROPOSED RTU. EACH EXISTING CONDUCTOR SHALL BE LABELED PRIOR TO DISCONNECTING FROM THE RTU TO AID INTHE INSTALLATION OF THE PROPOSED RTU.3. OWNER SHALL BE PROVIDED OPPORTUNITY TO REMOVE AND RETAIN ANY EQUIPMENT FROM EXISTING TELEMETRYPANEL. CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING OF ALL EQUIPMENT NOT RETAINED BY OWNER.4. CONTRACTOR SHALL REVIEW TELEMETRY PANEL DRAWINGS AND LAND EXISTING AND PROPOSED CONDUCTORS INTELEMETRY PANEL.5. INSTALL PROPOSED RTU IN THE SAME LOCATION AS THE EXISTING RTU AND EXTEND ALL EXISTING CONDUITS TOTHE PROPOSED RTU. CONTRACTOR SHALL MODIFY EXISTING CONDUIT AND INSTALL NEW CONDUIT AS NECESSARY TOREROUTE CONDUIT INTO THE PROPOSED TELEMETRY PANEL BASED ON THE PANEL SIZING.6. REFER TO PROPOSED SITE PLAN, DWG NO.C301, FOR FLOW METER CIRCUIT ROUTING.7.ALL INCOMING AND OUTGOING CIRCUITS TO BE DISCONNECTED FROM EXISTING TELEMETRY PANEL ANDRETERMINATED INSIDE PROPOSED TELEMETRY PANEL.8.DISCONNECT EXISTING SIERRA WIRELESS MODEM FROM EXISTING TELEMETRY PANEL AND RECONNECT TOPROPOSED TELEMETRY PANEL. SEE DWG NO.E303 FOR POWER AND COMMUNICATIONS CONNECTIONS.TELEMETRY PANEL INSTALLATION NOTESLEMETRY PANEL INSTALLATION NOTE BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LIB-E04.DWGSHOWNE302 2773DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LIBERTY LS RTU LAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3RTU PANEL LAYOUTLIBERTY LIFT STATIONCONTROL PANELNEMA TYPE 4XSTAINLESS STEEL12" DEEP ENCLOSUREOPERATOR INTERFACE.LOCATE OPERATORINTERFACE 5'-0" ABOVEFINISHED GRADE.NAME PLATEWARNING LABELWARNING120 VACKEEP OUTHANDLE1. CONTRACTOR SHALL CONFIRM ALL PANEL DIMENSIONS IN FIELD PRIOR TOFABRICATION DUE TO POTENTIAL INSTALLATION DIFFERENCES AND FIELDCONSTRAINTS.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LIB-E04.DWGSHOWNE303 2873DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LIBERTY LS POWER AND COMMSLAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3COMPACTLOGIX 5370 L1 PLCMODEL NO. 1769-L18ER-BB1BOPERATOR INTERFACEETHERNET SWITCHCOMMUNICATIONS LAYOUT8 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB84 PT ANALOG INPUT MODULEMODEL NO. 1734-IE4CL44CB120P20A1CBGNDPROTECTORLINE SURGELN120N24VDCPOWER SUPPLY10CBLNN2L10120 VAC 1PH 60HZ20A3CBL3LIGHTL2L55CBSPARE+24P24NPOWER LAYOUTL1N1L2N22CBBATTERYDC OUTDC INUPS24 VDCBATTERYDC OUTDC IN++---CB BATPANEL HEATERN5AC POWER FAILN3N4N97CBL7N78CBL8N8COMPACTLOGIX 1769-L18ER24P124VDC TO 24VDCPOWER SUPPLY DC OUTDC INDC OUTDC IN++--ETHERNET SWITCH24P3OPERATOR INTERFACE24P424P2COOLING FANSN6L66CB24P24NEXISTING WIRELESS MODEM24P5PLC INPUTS/OUTPUTS24P6BACKUP FLOATS24P7FLOW METER24P8SPARE24P9COMPACTLOGIX 5370 L1 PLC BASE,MODEL NO. 1769-L18ER-BB1BCAT 5E ETHERNET CABLECAT 5E ETHERNET CABLECAT 5E ETHERNET CABLESPARESPARE24P10EXISTINGANTENNAEXISTING COAXIAL CABLEEXISTING SIERRAWIRELESS MODEM(LOCATED OUTSIDERTU ENCLOSURE)12CB14CB15CB13CBDPF CRRDPF CRR17CB16CB18CB19CB11CBD20CBSPARE9CBL9N821CB BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LIB-E04.DWGSHOWNE304 2973DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LIBERTY LS INPUT AND OUTPUT WIRING1CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, BASE UNITDIGITAL OUTPUTS, BASE UNIT1. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LIB-E04.DWGSHOWNE305 3073DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LIBERTY LS INPUT AND OUTPUT WIRING2CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, SLOT 3DIGITAL INPUTS, SLOT 2DIGITAL INPUTS, SLOT 1DIGITAL INPUTS, SLOT 41. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LIB-E04.DWGSHOWNE306 3173DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LIBERTY LS INPUT AND OUTPUT WIRING3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3ANALOG INPUTS, SLOT 51. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LIB-E04.DWGSHOWNE307 3273DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LIBERTY LS CONTROL LOGICCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3BACK-UP FLOAT AND PUMP CONTROL BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-NO2-E01.DWGSHOWNE401 3373DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON NO. 2 LSELECTRICAL PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3EXISTING TELEMETRY PANEL INTERIOREXISTING TELEMETRY PANEL EXTERIOREXISTING TELEMETRY PANEL.PROPOSED TELEMETRY PANEL AND ELECTRICAL SHELTER ROOF IMPROVEMENTS1. COORDINATE TELEMETRY PANEL SHUTDOWN PERIOD WITH OWNER BEFOREHAND; 5 WORKING DAYS NOTICEREQUIRED. SHUTDOWN DURATION SHALL NOT EXCEED 5 CALENDAR DAYS.2. CONTRACTOR SHALL REMOVE ALL TELEMETRY COMPONENTS FROM THE EXISTING MOTOR CONTROL CENTEREXCEPT FOR FIELD WIRING TERMINAL BLOCKS. FIELD WIRING TERMINAL BLOCKS AND FIELD WIRING SHALL REMAIN INPLACE AND BE USED TO CONNECT EXISTING FIELD WIRING TO PROPOSED TELEMETRY PANEL.3. OWNER SHALL BE PROVIDED OPPORTUNITY TO REMOVE AND RETAIN ANY EQUIPMENT FROM EXISTING TELEMETRYPANEL. CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING OF ALL EQUIPMENT NOT RETAINED BY OWNER.4. CONTRACTOR SHALL REVIEW TELEMETRY PANEL DRAWINGS AND LAND EXISTING AND PROPOSED CONDUCTORS INTELEMETRY PANEL.5. INSTALL PROPOSED RTU ON UNISTRUT PEDESTAL AS SHOWN. CONTRACTOR SHALL INSTALL PROPOSED WIRINGBETWEEN PROPOSED RTU AND EXISTING RTU.TELEMETRY PANEL INSTALLATION NOTESLEMETRY PANEL INSTALLATION NOTPROPOSED TELEMETRYPANEL. SEE DWG NO.E408 FOR DETAILS.REMOVE EXISTING MCCTELEMETRY PANEL DOORAND REPLACE WITH ABLANK DOOR.REMOVE EXISTING CIRCUITBREAKERS, TYP.DO NOT DISTURB EXISTINGPOWER SUPPLIES, TYP.PROVIDE 20A 120V CIRCUITBREAKER TO PROPOSEDRTU.DO NOT DISTURB EXISTINGRADIO EQUIPMENT.DO NOT DISTURB EXISTINGINTRINSICALLY SAFEEQUIPMENT AND TERMINALBLOCKS, TYP.DO NOT DISTURB EXISTINGCONTROLS RELAYS, TYP.DO NOT DISTURB ALL FIELDWIRING TERMINAL BLOCKS, TYP.REMOVE WIRING BETWEENTERMINAL BLOCKS AND PLCMODULES. INSTALL PROPOSEDWIRING BETWEEN EXISTINGTERMINAL BLOCKS ANDPROPOSED TELEMETRY PANEL.PROPOSED 3/4" CONDUITCONTAINING:(2) - #12,(1) - #12 GRDPROPOSED 2 12" CONDUITCONTAINING:(84) - #14, (1) - #14 GRD(2) - 2-CONDUCTOR SHIELDEDCABLESPROPOSED CONDUITSCONTINUE TO EXISTINGTELEMETRY PANELSECTIONIN MOTOR CONTROL CENTER.PROPOSED 3/4" CONDUITCONTAINING:(1) CAT 5E ETHERNET CABLEREMOVE EXISTING ROOF AND PLYWOOD ANDREPLACE WITH PROPOSED PLYWOOD AND ROOF. BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-NO2-E03.DWGSHOWNE402 3473DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON NO. 2 LS RTULAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3RTU EXTERIOR PANEL DOOR LAYOUTWARNING LABELWARNING120 VACKEEP OUTNAMEPLATEPAD-LOCKABLEHANDLELAKE WASHINGTON NO. 2LIFT STATION CONTROL PANELRTU INTERIOR SWING DOOR LAYOUTPROVIDE RAIN HOOD FORINTAKE VENT AND EXHAUSTFAN, TYP.OPERATOR INTERFACE.LOCATE OPERATORINTERFACE 5'-0" ABOVEFINISHED GRADE.NEMA TYPE 4XSTAINLESS STEEL12" DEEP ENCLOSURE1. CONTRACTOR SHALL CONFIRM ALL PANEL DIMENSIONS IN FIELD PRIOR TOFABRICATION DUE TO POTENTIAL INSTALLATION DIFFERENCES AND FIELDCONSTRAINTS.ELECTRICAL NOTESELECTRICAL NOTESSUN SHADE. SMITH & LOVELESSH87A379 OR EQUAL. BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-NO2-E03.DWGSHOWNE403 3573DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON NO. 2 LS POWERAND COMMS LAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3COMPACTLOGIX 5370 L1 PLCMODEL NO. 1769-L18ER-BB1BOPERATOR INTERFACEETHERNET SWITCHCOMMUNICATIONS LAYOUTEXISTINGSURGEARRESTORT8 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB84 PT ANALOG INPUT MODULEMODEL NO. 1734-IE4CL44CB120P20A1CBGNDPROTECTORLINE SURGELN120N24VDCPOWER SUPPLY10CBLNN2L10120 VAC 1PH 60HZ20A3CBL3LIGHTL2L55CBSPARE+24P24NPOWER LAYOUTL1N1L2N22CBBATTERYDC OUTDC INUPS24 VDCBATTERYDC OUTDC IN++---CB BATPANEL HEATERN5AC POWER FAILN3N4N10FLOWMETER7CBL7N78CBL8N8COMPACTLOGIX 1769-L18ER24P124VDC TO 24VDCPOWER SUPPLY DC OUTDC INDC OUTDC IN++--ETHERNET SWITCH24P3OPERATOR INTERFACE24P4SPARE9CBL9N924P2EXISTINGANTENNACOOLING FANSN6L66CB24P24NETHERNET RADIO24P5PLC INPUTS/OUTPUTS24P6BACKUP FLOATS24P7SPARE24P8SPARE24P94 PT ANALOG OUTPUT MODULEMODEL NO. 1734-OE4CCOMPACTLOGIX 5370 L1 PLC BASE,MODEL NO. 1769-L18ER-BB1BCAT 5E ETHERNET CABLECAT 5E ETHERNET CABLECAT 5E ETHERNET CABLEEXISTING COAXIAL CABLEEXISTING COAXIAL CABLEEXISTING ETHERNETRADIO(LOCATED IN EXISTINGRTU ENCLOSURE)12CB14CB15CB13CBDPF CRRDPF CRR16CB18CB17CB19CB20CB11CBD BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-NO2-E03.DWGSHOWNE404 3673DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON NO. 2 LS INPUT ANDOUTPUT WIRING 1CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, BASE UNITDIGITAL OUTPUTS, BASE UNIT1. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-NO2-E03.DWGSHOWNE405 3773DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON NO. 2 LS INPUT ANDOUTPUT WIRING 2CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, SLOT 3DIGITAL INPUTS, SLOT 2DIGITAL INPUTS, SLOT 1DIGITAL INPUTS, SLOT 41. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-NO2-E03.DWGSHOWNE406 3873DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON NO. 2 LS INPUT ANDOUTPUT WIRING 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3ANALOG INPUTS, SLOT 51. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-NO2-E03.DWGSHOWNE407 3973DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON NO. 2 LS CONTROLLOGICCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3BACK-UP FLOAT AND PUMP CONTROL MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-NO2-E04.DWGSHOWNE408 4073DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LAKE WASHINGTON NO. 2 LS PEDESTALDETAILSCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3TELEMETRY PANEL PEDESTAL DETAIL6'-0"FINISHEDGRADEWIDTH AS NECESSARY1-5/8" SST UNISTRUT. ATTACH UNISTRUT ASNECESSARY TO SUPPORT ELECTRICALEQUIPMENT. SECURE ELECTRICALEQUIPMENT TO UNISTRUT.3" STD GALV STEELPOST WITH CAP, TYP.TELEMETRY PANELNOTE: INSTALL IN EXISTING CONCRETE SURFACE ANDPROVIDE MINIMUM 4" CONCRETE SIDE COVER FOR BOLTS. IFNECESSARY, POSTS CAN BE INSTALLED CLOSER TOGETHERWITH THE UNISTRUT EXTENDING BEYOND THE POSTS.4"TYPA36 PL 6"x6"x38"SIMPSON SET-3G WITH 3/8" F1554GR.36 ANCHOR, TYP 4. EMBED MIN4" INTO CONCRETE. SECURE WITHPLATE WASHER AND HEX NUT, TYP.PEDESTAL BASE PLATE DETAILEDGE OF CONCRETE4" MIN, TYP. FROMCONCRETE CURBAND ASPHALTSTEEL POST, TYP.PEDESTAL BASE PLATE. SEETHIS SHEET FOR DETAILS. UNION AVE NEUUUU MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LNG-C02.DWGSHOWNC501 4173DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LONG LS EXISTING SITEPLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3EXISTING SITE PLANPROPOSED PIG PORT INSIDE EXISTING VALVEVAULT, SEE DWG NO. M501 MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-LNG-M01.DWGSHOWNM501 4273DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:LONG LS MECHANICAL PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3LONG LIFT STATION EXISTING VALVE VAULT PLANLONG LIFT STATION PROPOSED VALVE VAULT PLANSECTIONEXISTING VALVE VAULTOBLIQUEAAACONNECTING ROD,TYP. OF 84" CHECK VALVE (FLxFL), TYP. OF 24" GATE VALVE (FLxFL), TYP. OF 34" 45° BEND (FLxFL)4"WYE(FLxFLxFL)SUMP PUMP4" FCA,TYP. OF 24" 90° BEND(FLxFL)REMOVE EXISTING SPOOL (FLxFL)4" SPOOL, LENGTH1'-4" (FLxFL)PROPOSED 4" DITEE (FLxFL)PROPOSED 2" STAINLESSSTEEL BALL VALVEPROPOSED 2" STAINLESSSTEEL NIPPLE AS REQUIRED,TYP. OF 2PROPOSED 4" ECCENTRICPLUG VALVE W/ HAND WHEELACTUATOR (FLxFL)PROPOSED 4" DI 90°BEND (FLxFL)PROPOSED 4" DI SPOOL(FLxFL), LENGTH 1'-0"PROPOSED 4" DI BLINDFLANGE WITH THREADED TAPPIPE SUPPORT,TYP.PROPOSED PIGPORT ASSEMBLYLADDERACCESS HATCHOUTLINEPROPOSED 4" DIROMAC FIELD FLANGEOR APPROVED EQUALPROPOSED 4" DISPOOL (FLxPE),APPROX. LENGTH 5"PROPOSED PIPESUPPORT CREST DR SCREST DR SBOT BTALBBMCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-TLB-C02.DWGSHOWNC601 4373DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:TALBOT CREST LSEXISTING SITE PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3EXISTING SITE PLANPROPOSED PIG PORT INSIDE EXISTINGROPVALVE VAULT, SEE DWG NO.M601INVESTIGATE SOURCE OF LEAKAGE POINT IN WETWELL. COORDINATE FINDINGS WITH OWNER. IFLEAK REPAIRS ARE REQUIRED, REFER TOSPECIFICATION SECTION 13.63.NHOLE TO BE USEDNEXISTING MANNASS OF WET WELLADURING BYPAANOTE: REFER TO DIVISION 11 IN THE SPECIFICATIONS FOR CONSTRUCTIONPHASING, BYPASS, AND TRAFFIC CONTROL REQUIREMENTS.REMOVE EXISTING DAVIT CRANE MOUNT.INSTALL PROPOSED STAINLESS STEELWALL MOUNTED DAVIT CRANE INSIDEEXISTING WET WELL PER MANUFACTURER'SRECOMMENDATIONS. COORDINATELOCATION WITH OWNER IN THE FIELD ANDDIAMETER REQUIRED FOR MAST.TALBOT CREST WET WELL DETAILEXISTING BELOW GRADESANITARY SEWER STRUCTUREABANDONED IN PLACE.PROPOSED DAVIT CRANEEDTO BE MOUNTED INSIDEMEXISTING WET WELL,STSEE DETAIL THIS SHEET.EECUT EXISTING BOLTS FLUSHWITH CONCRETE SURFACE. MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-TLB-M01.DWGSHOWNM601 4473DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:TALBOT CREST LS MECHANICAL PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3TALBOT CREST LIFT STATION EXISTING VALVE VAULT PLANTALBOT CREST LIFT STATION PROPOSED VALVE VAULT PLANEXISTING VALVE VAULTSECTIONAAAOBLIQUE4" FCA, TYP. OF 24" CHECK VALVE(FLxFL), TYP. OF 24" GATE VALVE WITH OPERATIONALNUT (FLxFL), TYP. OF 34"x4"x4" TEE (FLxFLxFL)REMOVE EXISTING 4"90° BEND (FLxFL)SUMP PUMP,TYP. OF 2CONNECTINGROD, TYP. OF 4PROPOSED 4" DITEE (FLxFLxFL)PROPOSED 2" STAINLESSSTEEL BALL VALVEPROPOSED 2" STAINLESS STEELNIPPLE AS REQUIRED, TYP. OF 2PROPOSED 4" ECCENTRICPLUG VALVE W/ HAND WHEELACTUATOR (FLxFL)PROPOSED 4" DI 90°BEND (FLxFL)PROPOSED 4" DI SPOOL(FLxFL), LENGTH 1'-0"PROPOSED 4" DI BLIND FLANGEWITH THREADED TAPPIPE SUPPORT,TYP.PRESSURE GAUGE, TYP.PROPOSED PIGPORT ASSEMBLYLADDERACCESS HATCHOUTLINE, TYP.OF 4REMOVE EXISTING 4"SPOOL (FLxFL)PROPOSED 4" FLOWMETER (FLxFL)PROPOSED 4" DISMANTLINGJOINT (FLxFL), INSTALLEDAT NOMINAL LAY LENGTHPROPOSED PIPESUPPORT, TYP. OF 2PROPOSED 4" DI SPOOL(FLxFL), LENGTH 2'-8",TYP. OF 2RELOCATE EXISTING HOSERACK IF NECESSARY OR ASREQUIRED BY OWNER BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-TLB-E03.DWGSHOWNE601 4573DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:TALBOT CREST LS ELECTRICAL PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3ALL INCOMING AND OUTGOINGCIRCUITS TO BE DISCONNECTEDFROM EXISTING TELEMETRYPANEL AND RETERMINATEDINSIDE PROPOSED TELEMETRYPANEL.EXISTING TELEMETRY PANEL INTERIOREXISTING TELEMETRY PANEL EXTERIOR1. COORDINATE TELEMETRY PANEL REMOVAL AND NECESSARY SHUTDOWN PERIOD WITH OWNER BEFOREHAND; 5WORKING DAYS NOTICE REQUIRED. SHUTDOWN DURATION SHALL NOT EXCEED 5 CALENDAR DAYS.2. CONTRACTOR SHALL DISCONNECT ALL EXISTING CONDUCTORS AND CONDUITS FROM THE EXISTING TELEMETRYPANEL (RTU) AND REMOVE THE EXISTING RTU FROM ITS LOCATION TO MAKE SPACE FOR INSTALLATION OF THEPROPOSED RTU. EACH EXISTING CONDUCTOR SHALL BE LABELED PRIOR TO DISCONNECTING FROM THE RTU TO AID INTHE INSTALLATION OF THE PROPOSED RTU.3. OWNER SHALL BE PROVIDED OPPORTUNITY TO REMOVE AND RETAIN ANY EQUIPMENT FROM EXISTING TELEMETRYPANEL. CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING OF ALL EQUIPMENT NOT RETAINED BY OWNER.4. CONTRACTOR SHALL REVIEW TELEMETRY PANEL DRAWINGS AND LAND EXISTING AND PROPOSED CONDUCTORS INTELEMETRY PANEL.5. INSTALL PROPOSED RTU IN THE SAME LOCATION AS THE EXISTING RTU AND EXTEND ALL EXISTING CONDUITS TOTHE PROPOSED RTU. CONTRACTOR SHALL MODIFY EXISTING CONDUIT AND INSTALL NEW CONDUIT AS NECESSARY TOREROUTE CONDUIT INTO THE PROPOSED TELEMETRY PANEL BASED ON THE PANEL SIZING.TELEMETRY PANEL INSTALLATION NOTESELEMETRY PANEL INSTALLATION NOTPROPOSED FLOWMETERPROPOSED 1" CONDUIT CONTAINING:(6) - #14, (1) - #14 GRD(1) - 2-CONDUCTOR SHIELDED CABLEEXISTING SPARE CONDUIT IN JUNCTIONBOX. CONNECT PROPOSED CONDUIT TOEXISTING. PROPOSED CONDUCTORSCONTINUE TO TELEMETRY PANELPEDESTAL.EXISTING SPARE CONDUITCONTINUES TO EXISTINGTELEMETRY PANEL PEDESTALROUTE CONDUIT FROMVAULT TO EXISTINGJUNCTION BOXOUTLINE OF GRADE-LEVELJUNCTION BOXREMOVE EXISTING ETHERNETRADIO AND INSTALL INPROPOSED RTU. SEE DWG NO.E603 FOR DETAILS.EXISTING CONDUITS TO BETERMINATED AT PROPOSEDTELEMETRY PANEL, TYPICAL OFALL CONDUITS ENTERINGEXISTING TELEMETRY PANEL.RECONNECT EXISTINGANTENNA TO PROPOSEDSURGE ARRESTOR USINGEXISTING COAXIAL CABLE.EXTEND EXISTING COAXIALCABLE AS NECESSARY TOREACH PROPOSED SURGEARRESTOR IN PROPOSEDRTU.EXISTING TELEMETRY PANEL TO BEREMOVED AND RETURNED TO OWNER.INSTALL PROPOSED TELEMETRY PANELIN SAME LOCATION AS EXISTINGTELEMETRY PANEL WITH STAINLESSSTEEL MOUNTING HARDWARE. VALVE VAULT ELECTRICAL PLAN BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-TLB-E04.DWGSHOWNE602 4673DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:TALBOT CREST LS RTU LAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3RTU EXTERIOR PANEL DOOR LAYOUTWARNING LABELWARNING120 VACKEEP OUTNAMEPLATEPAD-LOCKABLEHANDLETALBOT CREST LIFT STATIONCONTROL PANELRTU INTERIOR SWING DOOR LAYOUTPROVIDE RAIN HOOD FORINTAKE VENT AND EXHAUSTFAN, TYP.OPERATOR INTERFACE.LOCATE OPERATORINTERFACE 5'-0" ABOVEFINISHED GRADE.NEMA TYPE 4XSTAINLESS STEEL12" DEEP ENCLOSURE1. CONTRACTOR SHALL CONFIRM ALL PANEL DIMENSIONS IN FIELD PRIOR TOFABRICATION DUE TO POTENTIAL INSTALLATION DIFFERENCES AND FIELDCONSTRAINTS.ELECTRICAL NOTESELECTRICAL NOTESSUN SHADE. SMITH & LOVELESSTH87A379 OR EQUAL.U BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-TLB-E04.DWGSHOWNE603 4773DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:TALBOT CREST LS POWER AND COMMSLAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3COMPACTLOGIX 5370 L1 PLCMODEL NO. 1769-L18ER-BB1BOPERATOR INTERFACEETHERNET SWITCHCOMMUNICATIONS LAYOUT8 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB84 PT ANALOG INPUT MODULEMODEL NO. 1734-IE4CCOMPACTLOGIX 5370 L1 PLC BASE,MODEL NO. 1769-L18ER-BB1BCAT 5E ETHERNET CABLECAT 5E ETHERNET CABLEEXISTING ETHERNETRADIOSURGEARRESTOREXISTING ANTENNACAT 5E ETHERNET CABLECOAXIAL CABLEEXISTING COAXIAL CABLEL44CB120P20A1CBGNDPROTECTORLINE SURGELN120N24VDCPOWER SUPPLY10CBLNN2L10120 VAC 1PH 60HZ20A3CBL3LIGHTL2L55CBSPARE+24P24NPOWER LAYOUTL1N1L2N22CBBATTERYDC OUTDC INUPS24 VDCBATTERYDC OUTDC IN++---CB BATPANEL HEATERN5AC POWER FAILN3N4N97CBL7N78CBL8N8COMPACTLOGIX 1769-L18ER24P124VDC TO 24VDCPOWER SUPPLY DC OUTDC INDC OUTDC IN++--ETHERNET SWITCH24P3OPERATOR INTERFACE24P424P2COOLING FANSN6L66CB24P24NETHERNET RADIO24P5PLC INPUTS/OUTPUTS24P6BACKUP FLOATS24P7FLOW METER24P8SPARE24P9SPARESPARE24P1012CB14CB15CB13CBDPF CRRDPF CRR17CB16CB18CB19CB11CBD20CBSPARE9CBL9N821CB BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-TLB-E04.DWGSHOWNE604 4873DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:TALBOT CREST LS INPUT AND OUTPUTWIRING 1CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, BASE UNITDIGITAL OUTPUTS, BASE UNIT1. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-TLB-E04.DWGSHOWNE605 4973DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:TALBOT CREST LS INPUT AND OUTPUTWIRING 2CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, SLOT 3DIGITAL INPUTS, SLOT 2DIGITAL INPUTS, SLOT 1DIGITAL INPUTS, SLOT 41. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-TLB-E04.DWGSHOWNE606 5073DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:TALBOT CREST LS INPUT AND OUTPUTWIRING 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3ANALOG INPUTS, SLOT 51. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-TLB-E04.DWGSHOWNE607 5173DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:TALBOT CREST LS CONTROL LOGICCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3BACK-UP FLOAT AND PUMP CONTROL NE 10TH STPROPOSED PIGPORT INSIDEEXISTING VALVEVAULT, SEE DWGNO. M701E MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WED-C01.DWGSHOWNC701 5273DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WEDGEWOOD LS EXISTINGSITE PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3EXISTING SITE PLAN MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WED-M01.DWGSHOWNM701 5373DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WEDGEWOOD LS MECHANICAL PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3AAWEDGEWOOD LIFT STATION EXISTING VALVE VAULT PLANWEDGEWOOD LIFT STATION PROPOSED VALVE VAULT PLANOBLIQUEASECTIONEXISTING VALVE VAULT6" FCA, TYP. OF36" GATE VALVE (FLxFL), TYP. OF 36" CHECK VALVE(FLxFL), TYP. OF 26" 45° BEND (FLxFL),TYP. OF 2 REMOVE EXISTING 6"SPOOL(FLxFL)6" MAGNETIC FLOWMETER (FLxFL)6" TRUE WYE(FLxFLxFL)SUMP PUMPPROPOSED 6" DITEE (FLxFLxFL)PROPOSED 2"STAINLESSSTEEL BALLVALVEPROPOSED 2" STAINLESSSTEEL NIPPLE ASREQUIRED, TYP. OF 2PROPOSED 6" ECCENTRICPLUG VALVE W/ HANDWHEEL ACTUATOR FLxFL)PROPOSED 6" DI 90°BEND (FLxFL)PROPOSED 6" DI SPOOL(FLxFL), LENGTH 1'-0"PROPOSED 6" DI BLINDFLANGE WITH THREADED TAPPIPE SUPPORT, TYP.PROPOSED PIGPORT ASSEMBLYLADDERACCESS HATCH OUTLINEPROPOSED 6"EBAA 2100MEGAFLANGEPROPOSED 6" DISPOOL (FLxPE),APPROX. LENGTH 12"PROPOSED PIPESUPPORT BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WED-E03.DWGSHOWNE701 5473DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WEDGEWOOD LSELECTRICAL PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3EXISTING TELEMETRY PANEL EXTERIOREXISTING TELEMETRY PANEL TOBE REMOVED AND RETURNED TOOWNER. INSTALL PROPOSEDTELEMETRY PANEL IN SAMELOCATION.ALL INCOMING AND OUTGOINGCIRCUITS TO BE DISCONNECTEDFROM EXISTING TELEMETRYPANEL AND RETERMINATEDINSIDE PROPOSED TELEMETRYPANEL PER TELEMETRYDRAWINGS.1. COORDINATE TELEMETRY PANEL REMOVAL AND NECESSARY SHUTDOWN PERIOD WITH OWNER BEFOREHAND; 5WORKING DAYS NOTICE REQUIRED. SHUTDOWN DURATION SHALL NOT EXCEED 5 CALENDAR DAYS.2. CONTRACTOR SHALL DISCONNECT ALL EXISTING CONDUCTORS AND CONDUITS FROM THE EXISTING TELEMETRYPANEL (RTU) AND REMOVE THE EXISTING RTU FROM ITS LOCATION TO MAKE SPACE FOR INSTALLATION OF THEPROPOSED RTU. EACH EXISTING CONDUCTOR SHALL BE LABELED PRIOR TO DISCONNECTING FROM THE RTU TO AID INTHE INSTALLATION OF THE PROPOSED RTU.3. OWNER SHALL BE PROVIDED OPPORTUNITY TO REMOVE AND RETAIN ANY EQUIPMENT FROM EXISTING TELEMETRYPANEL. CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING OF ALL EQUIPMENT NOT RETAINED BY OWNER.4. CONTRACTOR SHALL REVIEW TELEMETRY PANEL DRAWINGS AND LAND EXISTING AND PROPOSED CONDUCTORS INTELEMETRY PANEL.5. INSTALL PROPOSED RTU IN THE SAME LOCATION AS THE EXISTING RTU AND EXTEND ALL EXISTING CONDUITS TOTHE PROPOSED RTU. CONTRACTOR SHALL MODIFY EXISTING CONDUIT AND INSTALL NEW CONDUIT AS NECESSARY TOREROUTE CONDUIT INTO THE PROPOSED TELEMETRY PANEL BASED ON THE PANEL SIZING.TELEMETRY PANEL INSTALLATION NOTESELEMETRY PANEL INSTALLATION NOTEXISTING TELEMETRY PANEL INTERIORALL INCOMING AND OUTGOINGCIRCUITS TO BE DISCONNECTEDFROM EXISTING TELEMETRYPANEL AND RETERMINATEDINSIDE PROPOSED TELEMETRYPANEL.REMOVE EXISTING ETHERNETRADIO AND INSTALL INPROPOSED RTU. SEE DWG NO.E703 FOR DETAILS.RECONNECT EXISTINGANTENNA TO PROPOSEDSURGE ARRESTOR USINGEXISTING COAXIAL CABLE.EXTEND EXISTING COAXIALCABLE AS NECESSARY TOREACH PROPOSED SURGEARRESTOR IN PROPOSEDRTU. BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WED-E05.DWGSHOWNE702 5573DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WEDGEWOOD LS RTULAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3RTU PANEL LAYOUTWEDGEWOOD LIFT STATIONCONTROL PANELNEMA TYPE 4XSTAINLESS STEEL12" DEEP ENCLOSUREOPERATOR INTERFACE.LOCATE OPERATORINTERFACE 5'-0" ABOVEFINISHED GRADE.NAME PLATEWARNING LABELWARNING120 VACKEEP OUTHANDLE1. CONTRACTOR SHALL CONFIRM ALL PANEL DIMENSIONS IN FIELD PRIOR TOFABRICATION DUE TO POTENTIAL INSTALLATION DIFFERENCES AND FIELDCONSTRAINTS.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WED-E05.DWGSHOWNE703 5673DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WEDGEWOOD LS POWER &COMMS LAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3COMPACTLOGIX 5370 L1 PLCMODEL NO. 1769-L18ER-BB1BOPERATOR INTERFACEETHERNET SWITCHCOMMUNICATIONS LAYOUT8 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB84 PT ANALOG INPUT MODULEMODEL NO. 1734-IE4CL44CB120P20A1CBGNDPROTECTORLINE SURGELN120N24VDCPOWER SUPPLY10CBLNN2L10120 VAC 1PH 60HZ20A3CBL3LIGHTL2L55CBSPARE+24P24NPOWER LAYOUTL1N1L2N22CBBATTERYDC OUTDC INUPS24 VDCBATTERYDC OUTDC IN++---CB BATPANEL HEATERN5AC POWER FAILN3N4N10FLOWMETER7CBL7N78CBL8N8COMPACTLOGIX 1769-L18ER24P124VDC TO 24VDCPOWER SUPPLY DC OUTDC INDC OUTDC IN++--ETHERNET SWITCH24P3OPERATOR INTERFACE24P4SPARE9CBL9N924P2COOLING FANSN6L66CB24P24NETHERNET RADIO24P5PLC INPUTS/OUTPUTS24P6BACKUP FLOATS24P7SPARE24P8SPARE24P9COMPACTLOGIX 5370 L1 PLC BASE,MODEL NO. 1769-L18ER-BB1BCAT 5E ETHERNET CABLECAT 5E ETHERNET CABLEEXISTING ETHERNETRADIOSURGEARRESTOREXISTING ANTENNACAT 5E ETHERNET CABLECOAXIAL CABLEEXISTING COAXIAL CABLE12CB14CB15CB13CBDPF CRRDPF CRR16CB18CB17CB19CB20CB11CBD BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WED-E05.DWGSHOWNE704 5773DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WEDGEWOOD LS INPUT ANDOUTPUT WIRING 1CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, BASE UNITDIGITAL OUTPUTS, BASE UNIT1. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WED-E05.DWGSHOWNE705 5873DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WEDGEWOOD LS INPUT ANDOUTPUT WIRING 2CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, SLOT 3DIGITAL INPUTS, SLOT 2DIGITAL INPUTS, SLOT 1DIGITAL INPUTS, SLOT 41. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WED-E05.DWGSHOWNE706 5973DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WEDGEWOOD LS INPUT ANDOUTPUT WIRING 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3ANALOG INPUTS, SLOT 51. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WED-E05.DWGSHOWNE707 6073DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WEDGEWOOD LS CONTROLLOGICCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3BACK-UP FLOAT AND PUMP CONTROL MCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WST-E03.DWGSHOWNE801 6173DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WESTVIEW LSELECTRICAL PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3EXISTING TELEMETRY PANEL EXTERIOREXISTING TELEMETRY PANEL EXTERIOREXISTING TELEMETRY PANEL INTERIORALL INCOMING AND OUTGOINGCIRCUITS TO BE DISCONNECTEDFROM EXISTING TELEMETRYPANEL AND RETERMINATEDINSIDE PROPOSED TELEMETRYPANEL.EXISTING TELEMETRY POWERENCLOSURE TO BE REMOVED ANDRETURNED TO OWNER. ALL INCOMINGAND OUTGOING CIRCUITS TO BEDISCONNECTED FROM EXISTINGTELEMETRY POWER ENCLOSURE ANDRETERMINATED INSIDE PROPOSEDTELEMETRY PANEL.EXISTING TELEMETRY PANEL TO BEREMOVED AND RETURNED TO OWNER.INSTALL PROPOSED TELEMETRY PANELIN SAME LOCATION AS EXISTINGTELEMETRY PANEL WITH STAINLESSSTEEL MOUNTING HARDWARE.EXISTING CONDUITS TO BETERMINATED AT PROPOSEDTELEMETRY PANEL, TYPICAL OFALL CONDUITS ENTERINGEXISTING TELEMETRY PANELAND POWER ENCLOSURE.1. COORDINATE TELEMETRY PANEL REMOVAL AND NECESSARY SHUTDOWN PERIOD WITH OWNER BEFOREHAND; 5WORKING DAYS NOTICE REQUIRED. SHUTDOWN DURATION SHALL NOT EXCEED 5 CALENDAR DAYS.2. CONTRACTOR SHALL DISCONNECT ALL EXISTING CONDUCTORS AND CONDUITS FROM THE EXISTING TELEMETRYPANEL (RTU) AND REMOVE THE EXISTING RTU FROM ITS LOCATION TO MAKE SPACE FOR INSTALLATION OF THEPROPOSED RTU. EACH EXISTING CONDUCTOR SHALL BE LABELED PRIOR TO DISCONNECTING FROM THE RTU TO AID INTHE INSTALLATION OF THE PROPOSED RTU.3. CONTRACTOR SHALL REVIEW TELEMETRY PANEL DRAWINGS AND LAND EXISTING AND PROPOSED CONDUCTORS INTELEMETRY PANEL.4. INSTALL PROPOSED RTU IN THE SAME LOCATION AS THE EXISTING RTU AND EXTEND ALL EXISTING CONDUITS TOTHE PROPOSED RTU. CONTRACTOR SHALL MODIFY EXISTING CONDUIT AND INSTALL NEW CONDUIT AS NECESSARY TOREROUTE CONDUIT INTO THE PROPOSED TELEMETRY PANEL BASED ON THE PANEL SIZING.5. INSTALL OWNER PROVIDED RADIO IN PROPOSED RTU. SEE TELEMETRY PANEL DRAWINGS FOR DETAILS.TELEMETRY PANEL INSTALLATION NOTESLEMETRY PANEL INSTALLATION NOTRECONNECT EXISTINGANTENNA TO PROPOSEDSURGE ARRESTOR USINGEXISTING COAXIAL CABLE.EXTEND EXISTING COAXIALCABLE AS NECESSARY TOREACH PROPOSED SURGEARRESTOR IN PROPOSEDRTU.REMOVE EXISTING ETHERNETRADIO AND INSTALL INPROPOSED RTU. SEE DWG NO.E803 FOR DETAILS. BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WST-E04.DWGSHOWNE802 6273DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WESTVIEW LS RTULAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3RTU EXTERIOR PANEL DOOR LAYOUTWARNING LABELWARNING120 VACKEEP OUTNAMEPLATEPAD-LOCKABLEHANDLEWESTVIEW LIFT STATIONCONTROL PANELRTU INTERIOR SWING DOOR LAYOUTPROVIDE RAIN HOOD FORINTAKE VENT AND EXHAUSTFAN, TYP.OPERATOR INTERFACE.LOCATE OPERATORINTERFACE 5'-0" ABOVEFINISHED GRADE.NEMA TYPE 4XSTAINLESS STEEL12" DEEP ENCLOSURE1. CONTRACTOR SHALL CONFIRM ALL PANEL DIMENSIONS IN FIELD PRIOR TOFABRICATION DUE TO POTENTIAL INSTALLATION DIFFERENCES AND FIELDCONSTRAINTS.ELECTRICAL NOTESELECTRICAL NOTESSUN SHADE. SMITH & LOVELESSH87A379 OR EQUAL. BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WST-E04.DWGSHOWNE803 6373DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WESTVIEW LS POWERAND COMMS LAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3COMPACTLOGIX 5370 L1 PLCMODEL NO. 1769-L18ER-BB1BOPERATOR INTERFACEETHERNET SWITCHCOMMUNICATIONS LAYOUTSURGEARRESTOR8 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB88 PT DIGITAL INPUT MODULEMODEL NO. 1734-IB84 PT ANALOG INPUT MODULEMODEL NO. 1734-IE4CL44CB120P20A1CBGNDPROTECTORLINE SURGELN120N24VDCPOWER SUPPLY10CBLNN2L10120 VAC 1PH 60HZ20A3CBL3LIGHTL2L55CBSPARE+24P24NPOWER LAYOUTL1N1L2N22CBBATTERYDC OUTDC INUPS24 VDCBATTERYDC OUTDC IN++---CB BATPANEL HEATERN5AC POWER FAILN3N4N10FLOWMETER7CBL7N78CBL8N8COMPACTLOGIX 1769-L18ER24P124VDC TO 24VDCPOWER SUPPLY DC OUTDC INDC OUTDC IN++--ETHERNET SWITCH24P3OPERATOR INTERFACE24P4SPARE9CBL9N924P2COOLING FANSN6L66CB24P24NETHERNET RADIO24P5PLC INPUTS/OUTPUTS24P6BACKUP FLOATS24P7SPARE24P8SPARE24P9COMPACTLOGIX 5370 L1 PLC BASE,MODEL NO. 1769-L18ER-BB1BCAT 5E ETHERNET CABLECAT 5E ETHERNET CABLECAT 5E ETHERNET CABLECOAXIAL CABLEEXISTING ETHERNETRADIOEXISTING ANTENNAEXISTING COAXIAL CABLE12CB14CB15CB13CBDPF CRRDPF CRR16CB18CB17CB19CB20CB11CBD BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WST-E04.DWGSHOWNE804 6473DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WESTVIEW LS INPUT ANDOUTPUT WIRING 1CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, BASE UNITDIGITAL OUTPUTS, BASE UNIT1. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WST-E04.DWGSHOWNE805 6573DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WESTVIEW LS INPUT ANDOUTPUT WIRING 2CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3DIGITAL INPUTS, SLOT 3DIGITAL INPUTS, SLOT 2DIGITAL INPUTS, SLOT 1DIGITAL INPUTS, SLOT 41. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WST-E04.DWGSHOWNE806 6673DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WESTVIEW LS INPUT ANDOUTPUT WIRING 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3ANALOG INPUTS, SLOT 51. EXISTING EQUIPMENT OR CONNECTION.2. PROPOSED EQUIPMENT OR CONNECTION.3. FUTURE EQUIPMENT OR CONNECTION.ELECTRICAL NOTESELECTRICAL NOTES BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-WST-E04.DWGSHOWNE807 6773DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:WESTVIEW LS CONTROLLOGICCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3BACK-UP FLOAT AND PUMP CONTROL CEDARRRR RIVEVEVERVERAPLMAPAPPLAPAPALLVAVALLPLE VAALLVAVAPLEYLEYEYEYEYEYLEALLELELEALLEY HIGHWAYEYPROPOSED SITE PLANJDEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-CWD-C01.DWGSHOWNC901 6873DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:COTTONWOOD LS PROPOSED SITEPLANABANDONEDWET WELLPROPOSED 1" CONDUITCONTAINING:(6) -#14,(1) - #14 GRD(1) - 2-CONDUCTORSHIELDED CABLECITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3NOTES:1. REFER TO DIVISION 11 IN THE SPECIFICATIONS FOR CONSTRUCTION PHASING, BYPASS, ANDTRAFFIC CONTROL REQUIREMENTS.2. ANY LIMITED ACCESS, LANE OR ROAD CLOSURES DURING CONSTRUCTION ACTIVITIES REQUIRETHE CONTRACTOR TO PROVIDE 48-HOUR WRITTEN NOTICE TO THE OWNER AND RESIDENTS.3. OPEN CUT WORK SHALL BE DILIGENTLY COMPLETED TO LIMIT DRIVEWAY CLOSURE DOWNTIME.OPEN TRENCHES SHALL BE SECURED WITH STEEL PLATES AT THE END OF EACH WORKING DAY.COTTONWOOD WET WELL EXISTINGDAVIT CRANE MOUNT DETAILREMOVE EXISTING DAVIT CRANE MOUNT.COMPONENTS BELOW THE TOP OF THE WETWELL LID MAY BE ABANDONED IN PLACE TOMINIMIZE IMPACT TO THE CONCRETE LID.FINISHED SURFACE SHALL BE RESTORED WITHGROUT AND FLUSH WITH THE EXISTING LID.RESTORE PAVEMENT ANDCONCRETE SURFACE TO EXISTINGOR BETTER CONDITION PERDETAIL ON DWG NO. G001.EXISTING MANHOLE TOBE USED DURINGBYPASS OF WET WELLRESTORE LANDSCAPED SURFACETO EXISTING OR BETTER CONDITIONPER DETAILON DWG NO. G002.REMOVE EXISTING PANELAND INSTALL PROPOSEDPANEL IN THE SAME PLACE.PROPOSED 3/4" CONDUIT CONTAINING:(1) - CAT 5E ETHERNET CABLEPROPOSED 1 12" SPARECONDUIT CONTAINING:(1) NYLON PULL CORDEXISTING DAVIT CRANE MOUNT TO BEREMOVED, SEE DETAIL THIS SHEET.PROPOSED DAVITCRANETO BEMOUNTED INSIDE EXISTING WETWELL, SEE DETAIL THIS SHEET.COTTONWOOD WET WELL PROPOSEDDAVIT CRANE MOUNT DETAILINSTALL PROPOSEDSTAINLESS STEEL WALLMOUNTED DAVIT CRANEINSIDE EXISTING WET WELLPER MANUFACTURER'SRECOMMENDATIONS.COORDINATE LOCATIONWITH OWNER IN THE FIELDAND DIAMETER REQUIREDFOR MAST.1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111INSTALL OWNERPROVIDEDTELEMETRY PANEL. EXISTING LIFT STATION MECHANICAL PLANEXISTING MECHANICAL OBLIQUEMECHANICAL ELEVATIONAAAMCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-CWD-M01.DWGSHOWNM9016973DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:REMOVE EXISTING4" FCA, TYP. OF 4REMOVE EXISTING 4" CHECKVALVE (FLxFL), TYP. OF 2REMOVE EXISTING 4" GATEVALVE (FLxFL), TYP. OF 2REMOVE EXISTING 4"90° BEND (FLxFL)REMOVE EXISTING4" TEE (FLxFL)REMOVE EXISTING PIPESUPPORTEXISTING WETWELLEXISTING VALVE VAULTREMOVE EXISTINGSUBMERSIBLE PUMP,TYP. OF 2REMOVE EXISTINGPUMP RAILS, TYP. OF 2REMOVE EXISTING 4" VERTICALDISCHARGE PIPING, COUPLING,AND (2) BENDS, TYP. OF BOTHPUMPS.CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3REMOVE EXISTING SPOOL ANDSHACKLE RODS APPROX LENGTH 0'-9"COTTONWOOD LS EXISTINGMECHANICAL PLANACCESS HATCH OUTLINE(5'-0"x6'-8")ACCESS HATCHCLEAR OPENINGEXISTING SPOOL AND SHACKLERODS TO BE CUT AS NECESSARYTO BE RE-PURPOSED FORREVISED PIPING, TYP. OF 3. PROPOSED LIFT STATION MECHANICAL PLANPROPOSED MECHANICAL OBLIQUEAAMCCBEHAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-CWD-M02.DWGSHOWNM9027073DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:PROPOSED 4"FCA, TYP. OF 4PROPOSED 4" CHECKVALVE (FLxFL), TYP. OF 2PROPOSED 4" GATEVALVE (FLxFL), TYP. OF 2PROPOSED 4" DI90° BEND (FLxFL)PROPOSED 4" DITEE (FLxFL)PROPOSED PIPESUPPORT, TYP. OF 2CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3PROPOSEDSUBMERSIBLEPUMP, TYP. OF 2PROPOSED 4" FLOWMETER (FLxFL)PROPOSED 4" DI SPOOL (FLxPE), APPROXLENGTH 0'-9" WITH PROPOSED SHACKLE RODSPROPOSED PUMPGUIDE RAILS, TYP. OF 2MECHANICAL ELEVATIONAPROPOSED 4" 90° BEND(FLxFL), TYP. OF 2PROPOSED 4" DI SPOOL(FLxFL), LENGTH 9'-4",TYP. OF 2FILL BOTTOM OF EXISTING WETWELL WITH 6" OF CONCRETEPUMP ANCHOR BOLTSPER MANUFACTURERRECOMMENDATIONSCOTTONWOOD LS PROPOSEDMECHANICAL PLANACCESS HATCHCLEAR OPENING2'-5"CLCCPUMP GUIDERAILBRACKET,MOUNTPER MANUFACTURER'SRECOMMENDATIONS. BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-CWD-E01.DWGSHOWNE901 7173DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:COTTONWOOD LSELECTRICAL PLANCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3EXISTING LEVEL CONTROLPANEL, TO BE REMOVED.INSTALL PROPOSED LEVELCONTROL PANEL IN SAMELOCATION.EXISTING LEVEL CONTROL PANELRELOCATE EXISTING LEVELTRANSMITTER EQUIPMENTTO PROPOSED LEVELCONTROL PANEL.MODIFY EXISTING CONDUITS ANDINSTALL NEW CONDUIT ASNECESSARY TO REROUTECONDUIT TO THE PROPOSEDLEVEL CONTROL PANEL.EXISTING MOTOR CONTROL CENTEREXTERIOR1. COORDINATE TELEMETRY PANEL SHUTDOWN PERIOD WITH OWNER BEFOREHAND; 5 WORKING DAYS NOTICEREQUIRED. SHUTDOWN DURATION SHALL NOT EXCEED 5 CALENDAR DAYS.2. CONTRACTOR SHALL REMOVE ALL TELEMETRY COMPONENTS FROM THE EXISTING MOTOR CONTROL CENTEREXCEPT FOR FIELD WIRING TERMINAL BLOCKS AND POWER SUPPLIES. FIELD WIRING TERMINAL BLOCKS AND FIELDWIRING SHALL REMAIN IN PLACE AND BE USED TO CONNECT EXISTING FIELD WIRING TO OWNER PROVIDEDTELEMETRY PANEL.3. OWNER SHALL BE PROVIDED OPPORTUNITY TO REMOVE AND RETAIN ANY EQUIPMENT FROM EXISTING TELEMETRYPANEL. CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING OF ALL EQUIPMENT NOT RETAINED BY OWNER.4. CONTRACTOR SHALL REVIEW TELEMETRY PANEL DRAWINGS AND LAND EXISTING AND PROPOSED CONDUCTORS INOWNER PROVIDED TELEMETRY PANEL.TELEMETRY PANEL INSTALLATION NOTESELEMETRY PANEL INSTALLATION NOTREPLACE DOOR WITHBLANK DOOR.DO NOT DISTURB EXISTINGPOWER SUPPLIES, TYP.REMOVE EXISTING CIRCUITBREAKERS, TYP.REMOVE EXISTING RADIOAND INSTALL IN OWNERPROVIDED TELEMETRYPANEL.PROVIDE 20A 120V CIRCUITBREAKER TO OWNERPROVIDED TELEMETRYPANEL.DO NOT DISTURB ALL FIELDWIRING TERMINAL BLOCKS, TYP.REMOVE WIRING BETWEENTERMINAL BLOCKS AND PLCMODULES. INSTALL PROPOSEDWIRING BETWEEN EXISTINGTERMINAL BLOCKS AND OWNERPROVIDED TELEMETRY PANEL.OWNER PROVIDEDTELEMETRY PANELREMOVE EXISTINGCONTROL RELAYS, TYP.INTRINSICALLY SAFE EQUIPMENT,TO BE REMOVED. REPLACE WITHTERMINAL BLOCKS TO FACILITATEEXTENDING CIRCUITS TO OWNERPROVIDED TELEMETRY PANEL.EXISTING TELEMETRY PANELEXISTING MOTOR CONTROL CENTERINTERIORPROPOSED 3/4" CONDUIT CONTAINING:(1) COAXIAL CABLESPLICE PROPOSED COAXIALCABLE FROM OWNERPROVIDED TELEMETRYPANEL TO EXISTING CABLE.PROPOSED 1 1/2" CONDUIT CONTAINING:(80) - #14, (1) - #14 GRD(1) - 2-CONDUCTOR SHIELDED CABLEPROPOSED 3/4" CONDUIT CONTAINING:(2) - #12, (1) - #12 GRDPROPOSED 1" CONDUIT CONTAINING:(12) - #14, (1) - #14 GRD(1) - 2-CONDUCTOR SHIELDED CABLEEXISTING TELEMETRYPANELPENETRATE MCC EXTERIORAND PROVIDE CONDUIT ASNECESSARY TO REACHEXISTING TELEMETRY PANEL. BPCBPCAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-CWD-E02.DWGSHOWNE902 7273DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:COTTONWOOD LS PANELLAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3LEVEL CONTROL PANEL EXTERIOR LAYOUTCOTTONWOOD LIFT STATIONLEVEL CONTROL PANELNEMA TYPE 4XSTAINLESS STEEL12" DEEP ENCLOSUREOPERATOR INTERFACE.LOCATE OPERATORINTERFACE 5'-0" ABOVEFINISHED GRADE.NAME PLATEWARNING LABELWARNING120 VACKEEP OUTPAD-LOCKABLEHANDLELEVEL CONTROL PANEL INTERIOR SWING DOOR LAYOUTPUMP 1 HOA SWITCHWET WELL LIGHTSSWITCHPUMP 2 HOA SWITCHYARD LIGHTSSWITCHSUMP PUMPHAND-AUTO SWITCHALLOCATE SPACE INSIDEPROPOSED PANEL FORRELOCATED LEVELTRANSMITTER EQUIPMENT.RECONNECT LEVELTRANSMITTER EQUIPMENTTO EXISTING FIELD WIRING.1. CONTRACTOR SHALL CONFIRM ALL PANEL DIMENSIONS IN FIELD PRIOR TOFABRICATION DUE TO POTENTIAL INSTALLATION DIFFERENCES AND FIELDCONSTRAINTS.ELECTRICAL NOTESELECTRICAL NOTESSUN SHADE. SMITH & LOVELESSH87A379 OR EQUAL. BPCMWBAug 10, 2023Aug 10, 2023REN117-037RENLS3-D-CWD-E02.DWGSHOWNE903 7373DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"DRAWING IS FULL SCALE WHENBAR MEASURES 2"SCALE:COTTONWOOD LS POWERAND COMMS LAYOUTCITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3CITY OF RENTONLIFT STATION AND FORCE MAINIMPROVEMENTS - PHASE 3OPERATOR INTERFACEETHERNET SWITCHCOMMUNICATIONS LAYOUTL54CB120P20A1CBGNDPROTECTORLINE SURGELN120N24VDCPOWER SUPPLY7CBLNL8120 VAC, RECONNECTTO EXISTING WIRING24P24NPOWER LAYOUTL1L22CBL3SPARE6CBL724P24NCAT 5E ETHERNET CABLECAT 5E ETHERNET CABLEFROM TELEMETRY PANEL3CBL4SPARE5CBL6OPERATOR INTERFACE9CB24P2ETHERNET SWITCH8CB24P1SPARE10CB24P3SPARE11CB24P4N3N4N5N6N7N8N1N2WET WELL LIGHTS(RECONNECT TO EXISTING WIRING)YARD LIGHTS(RECONNECT TO EXISTING WIRING)RECONNECT TOEXISTING PUMP 1HOA WIRINGRECONNECT TOEXISTING PUMP 2HOA WIRINGRECONNECT TOEXISTING SUMP PUMPHAND-AUTO WIRING