Loading...
HomeMy WebLinkAboutHighlands Elect Tennis Court E2 01 12.16.02120/240 V. 1 4) 3W PANEL P I Z� � a t4 �2 24,_ NEUT UTILITY COMPANY TRANSFORMER DATA SIZE: IMPEDANCE: FAULT CURRENT: MAIN BREAKER - BRANCH BREAKER- 1 $ 2 3 4 TC 0 0 zz TENNIS COURT SPARE SPARE SPARE - POLES TI & T3 SECURITY LIGHTS POLES T2 & T4 PROVIDE THREADED INSERT TO ATTACH BRACKET TO POLE. SEE SHEET E4 FOR BRACKET DETAILS 12.2 m LEVEL POLE WITH DOUBLE NUTS. COAT ANCHOR PLATE & EXPOSED BOLTS WITH CARBONLASTIC. GROUT PROVIDE DUPLEX UNDER ANCHOR PLATE FESTOON OUTLET AND FINISH TO MATCH ON POLE T3. EXISTING GRADE. 120V. 20A. GFCI 6' H 10 6A H 10 +A H I0 •A H 10' CONNECT TO P-1 CONTACTOR COIL P-5 P-1 P-5 OFF DELAY RELAY DELAY RELAYS TO BE IDEC ICE CUBE. SOCKET TYPE, 30 TO 60 MINUTE RANGE. MOUNTED ON RAILS ON DELAY AND INSTALLED IN NEW CONTROL CABINET. RELAY IDEC TYPE RTEL OR APPROVED EQUAL. �R\Wxo ^ • . °� �— HANDHOLE. INSTALL 24�a oo �eo ON 6' FREE DRAINING GRAVEL 6 I" X 60" X 4" _ J-BOLTS h — 30'—►i TENNIS COURT LIGHTING STANDARD DETAIL SCALE - NONE BUSSED CT COMPARTMENT PER PSE REQUIREMENTS GASKET ' ;PANEL SCREEN[ WIRE GLASS ® , P TOP & E WINDOW TIME -a CLOCK LIGHTING CONTACTORS & RELAYS 5 it It, 24- 11 ;�t� 6x6in-IOi1v VVIVU INCOMING CONDUITS OUTGOING CONDUITS. INCLUDE SPARES SHOWN FRONT r — 30' MIN. SIDE ONE LINE DIAGRAM NO SCALE ROTATING BEACON, PIPE MOUNTED. EDWARDS #52 OR APPROVED EQUAL. PUSH BUTTON AT EXTEND PUSH BUTTON CONDUIT TENNIS COURTS. AND MOUNT BEACON. TEST SWITCH INSTALL IN NEW CONTROL CABINET. KEY SHIELDED CONVENTIONAL FLOODLIGHT. NEMA V. 1000 WATT D METAL HALIDE. 240 VOLT ❑ 12.2 METER SQUARE PRESTRESSED CONRETE POLE (BUFF CEMENT) B ROTATING BEACON. PIPE MOUNTED. EDWARDS #52 OR PRIOR 0 APPROVED EQUAL. PUSHBUTTON MOUNTED ON CAST ALUMINUM BOX. PB REES #0137-012 ® TYPE I JUNCTION BOX. SEE SPECS 0 TYPE II JUNCTION BOX. SEE SPECS DUPLEX RECEPTACLE, 20A. 120 VOLT (WEATHERPROOF WP-GFi COVER. GROUND FAULT INTERRUPTER) TC ELECTRONIC TIME CLOCK - #Z400 PE PHOTOCELL 105-285 V. 1800 VA. MOUNT ON SWITCHBOARD. PROVIDE PROTECTIVE SCREEN $ SWITCH 15A. 120V. LC -I 3P3OA ELECTRICALLY HELD LIGHTING CONTACTOR WITH 120 VOLT COIL LC-2 SAME EXCEPT 4P6OA 0 sA H \ HOA SWITCH - SQUARE D MINIATURE TYPE CLASS 9001 ID 4' C. 3 #4/0 O2 2' C. WITH NPS - FUTURE OR SPARE O 2" C. 3 #8 (POLES TI & T3) 3 #8 (POLES T2 & T4) 4 #10 (RECEPTACLES) / 1 4 #10 (PUSH BUTTON\BEACON) 1 #10 (GROUND) ® 2" C. 3 #8. 4 #10. 1 #10 GRND. O5 2" C. 3 #8. 1 #10 GRND. © 75" C. 2 #10. 1 #10 GRND. / O7 .75' C. 4 #12. 1 #12 GRND. / PANEL SCHEDULE NO ., P LOCATION:...STORAGE....BUILDING 120/240 .._ VOLTS I PHASE 3 WIRE SERVING: ELECTRICAL 100 AMP WITH MAIN BREAKER CKT LOAD DESCRIPTION KVA TRIP TRIP KVA LOAD DESCRIPTION N0. AMPS �—}- AMPS NO. POLES, TI & ,,T3 .,,, .. 7.2 30 __ 30 0.4 SECURITY_ LIGHTS 2 4 5 P,OLES,, T2 . T4 .... 7.2 30 .. _ �_ .20 0.4 RECEPTACLE - COURT 6 0.4 RECEPTACLE - PEDESTAL 8 9 _ ,20 O.4 RECEPTACLE - POLE T3_ 10 SPACE ONLY 12 13 SPACE ONLY............... SPACE ONLY 14 15 SPACE ONLY _ _ SPACE ONLY 16 17 SPACE ONLY _ _ . SPACE ONLY 18 19 SPACE ONLY ,,. _ _ _ SPACE ONLY 20 21 SPACE ONLY _ _ SPACE ONLY 22 23 SPACE ONLY, .,,. ., 6.4 TIME CLOCK 24 REMARKS: .. CONNECTED LOAD: 8.4_ KVA 35 AMPS DEMAND LOAD: 100% KVA AMPS 60' EXISTING PSE SECONDARY PULLING VAULT N� EoM�N�s 5 TI NEW PEDESTAL ' PANEL LIGHT READING POINT (TYPICAL) 30 0 60 FEET L_. RECORD DRAWING DATE: 16 DEC 2002 FROM DATA PROVIDED BY CONTRACTOR tt SPAKLING ELECTRICAL ENGINEERINO I TEGMIDLOGY CONSULTING 720 Olive Way 206-667-0555 Suite 1400 800-887--0610 Seattle, Washington Fay 206-667-0554 90101-1853 www$parling.com ARIVISTROM ENGINEERS 1840 - 13 + AVENUE N.E. SUTE m BELLEVUE. WASFNGTON 98005-22 425.8852 S FAX: 425556.9351 COPYRIGHT 0 J. DELVIN ARMSTRONG 200 Oro.? H E °F RAsgl�c � joy � v - � 31353 '� +4�IS N�►L � ���' EXPIRES 16 JULY 2003 REVISION DATE DESCRIPTION ASO • SCALE: I' - 30' DESIGNED BY: C. B. F. DRAWN BY: R. D. L. DATE: 27 AUG 01 PROJECT NO: 1780 FILE NAME: B10970 E2 REC.Vcd PEDESTAL PANEL DETAIL NO SCALE SHEET: