Loading...
HomeMy WebLinkAboutMFP24001935.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP24001935 IVR Number: 24001935 Permit Information Permit Name: Puget Sound Energy - Electric Address/Location:04/15/2024Application Date:1823059253Parcel Number: 300 SW 7TH ST Permit Type:04/25/2024Issue Date:Franchise Permit Work Class:04/25/2025Expiration Date:Minor Utility Job Number: 101130455Franchise Type:Electric Description: Puget Sound Energy Electric REMOVING 3 PRIMARY CABLES FROM J01 TO V02. TRENCHING FROM IP01 TO V02 PARTIALLY IN THE ROW(TRENCHING 5FT IN SIDEWALK IN THE ROW ONLY). CREW TO PARK IN ROW FOR WORK ON PVT PROPERTY. Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031ApplicantX Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: 5109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08 Bellevue, WA 98009 B: (888) 225-5773Emergency Contact CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering PLEASE SEE ATTACHED POTELCO, INC 6905 S 228TH ST KENT, WA 98032 101130455 300 SW 7TH ST CHRISTIAN DOYLE 253-308-5903 MFP24001935 Scott Warlick CED Monday - Friday 8:00AM - 3:00PM 4/25/2024 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) CORRIE RYDBERG 300 SW 7th St Renton WA 98057 USA100'12 11 12 11 12 12 11 12 11 12 100'100'100'ARRW-BRD RIGHT LANE CLOSED AHEAD W20-5RW4-2RROAD WORK AHEAD W20-1ROADWORKAHEADW20-1X'X'PLACE W20-1 SIGNS ON ALLADJACENT STREETS WITHIN300 FEET OF WORK AREAROADWORKAHEADW20-1 ROADWORKAHEADW20-1V02SW 7TH STHARDIE AVE SWLIND AVE SWRESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSURENSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVMatlock Highbarger(808) 375-4152Matlock.Highbarger@PSE.com1 OF 1300 SW 7th St, Renton, WA0 11700912 02/05/2024Notes:1. All signs and spacing to conform to theMUTCD and City of RENTON standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hoursas per jurisdictional requirements. (Generallybetween 9 a.m. and 4 p.m. on non-arterials andfrom 9 a.m. to 3 p.m. on arterials. If night timework is approved, Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPUG/BOX/VAULTVAULTMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. ES2 000299Card Exp. 09/30/2027gregory.harwood@pse.com(425)424-6425MFP24001935 SW 7TH ST P# 1823059038 150 P# 1923059072 333 P# 1923059104 225 P# 1823059253 300 AØ4566 BØ4567 CØ4568 TO BE REMOVED AØ4563 BØ4564 CØ4565 TO BE REMOVED AØ4560 BØ4561 CØ4562 TO BE REMOVED AØ4557 BØ4558 CØ4559 TO BE REMOVED 4-4" - L______' NEW CONDUIT 180 lbs 197 lbsSW 7TH ST 1-4" EXISTING CONDUIT EJF472 - AØ EJF473 - BØ EJF474 - CØ 1-4" EXISTING CONDUIT 1-4" EXISTING CONDUIT 1-4" EXISTING CONDUIT 101130455Potelco, Inc.DESIGNED BY No No No Yes Yes Yes "Flagging Required" "Outages Required" "Locates Required" MAKE NO CHANGES TO THIS JOB WITHOUT PRIOR APPROVAL Notify Customers and Service Area 48 HRS Prior To Planned Outages ORDER#NOTIF#PROJECT PHASE MAINTENENCE O & M SUPERIOR FAILED SILICONE REMOVAL EXPENSE 11700912 101130455 N/A 108122050 584050950 594157991 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. SITE PLAN SCALE: 1:50 EXISTING OH MAP: # . SCALE: 1:880 2305E076 EXISTING UNDERGROUND MAP: # . SCALE: 1:100 2305E071 VAULT & EQUIPMENT TABLE SITE GRID NUMBER VAULT SIZE & COVER TYPE & SIZE EQUIPMENT IN VAULT PRIMARY BUSHINGS TRANSFORMER ID NUMBERS (COMPANY ID) REMARKS LB DC S01 317610 165745 EXISTING SWITCH EXISTING SWITCH -- REMOVE SWITCH & PSE EQUIPMENT S02 317611 165745 EXISTING SWITCH EXISTING SWITCH -- REMOVE SWITCH & PSE EQUIPMENT S03 317587 165753 EXISTING SWITCH EXISTING SWITCH -- J01 317588 165754 EXISTING JUNCTION BOX J-BOX BELOW GRADE W/ 3-4 POS. J-BUS EXISTING 3 - J02 317587 165754 EXISTING JUNCTION BOX J-BOX BELOW GRADE W/ 3-4 POS. J-BUS EXISTING -3 V01 317612 165745 EXISTING VAULT 3x250kVA TUT XFMR 277/480v EXISTING -- REMOVE XFMRS & PSE EQUIPMENT NEW V02 317602 165754 NEW 7' X 7' X 4' HH W/ 5' X 2' ACCESS & 8' SQ COVER (MID: 7917901) NEW 750kVA PM XFMR 277/480v MATID: 6259300 3 - INSTALL NEW PM XFMR PER STD 6045.5000 REPLACE ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS TOTALS :6 3 JOB SITE SITE SPECIFIC NOTES V02 (317602-165754) -CUSTOMER TO EXCAVATE HOLE & LAY CRUSHED ROCK FOR NEW VAULT -INSTALL NEW 774 VAULT W/ 8' SQ LID & 5' X 2' ACCESS HOLE (PM3P15M) PER STD 6045.5000 -INSTALL NEW 750kVA PM XFMR (MID: 6259300) PER STD 6045.5000 J01 (317588-165754) TO V02 (317602-165754) -REMOVE CABLES AØ4560, BØ4561, CØ4562 -CUSTOMER TO TRENCH FROM V02 TO IP01 APPROX. 15' -INSTALL NEW 4-4" SCH80 CONDUIT FROM V02 TO IP01 APPROX. 15' -INSTALL NEW 1/0 PRI CABLE TO V02 APPROX. 120' J02 (317587-165754) TO S02 (317611-165745) -REMOVE CABLES# AØ4557, BØ4558, CØ4559 -INSTALL (2) CONDUIT PLUGS (MID: 7643200) -INSTALL (3) DUST CAPS @ J02 (MID: 7630600) S02 (317611-165745) TO S01 (317610-165745) -REMOVE CABLES# AØ4563, BØ4564, CØ4565 S01 (317610-165745) TO V01 (317612-165745) -REMOVE CABLES# AØ4566, BØ4567, CØ4568 J01 (317588-165754) TO S01 (317610-165745) -REMOVE CABLES# AØ4560, BØ4561, CØ4562 -INSTALL (1) CONDUIT PLUG @ S01 (MID: 7643200) V01 (317612-165745) -REMOVE EXISTING (3) 250kVA 277/480V TUT XFMRS S01 (317610-165745) -REMOVE EXISTING SWITCH #U0214 S02 (317611-165745) -REMOVE EXISTING SWITCH #U0215 NOTE -CUSTOMER TO INSTALL NEW SERVICE TO METER UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP C. DOYLE 253-308-5903 1/23/24 L. NEELY 253-569-2523 1/23/24 N/A N/A N/A C. DOYLE 253-308-5903 1/23/24 RW-133103 RENTON EAR-16 CREW2 300 SW 7TH ST RENT REMOVE (2) SWITCHES & (3) TUT XFMRS, INSTALL PM XFMR 300 SW 7TH ST, RENTON, WA 98057 N/A N/A N/A 101130455 AS NOTED 1/1 KING N/A N/A QCSOKE SW 18-05-23 N/A N/A 2305E071 2305E076 2305E071 EAR-16 N/A N/A N/A N/A N/A N/A N/A N/A N/A Installed at site: Grid Number: kVA Rating: TRANSFORMER INSTALLATION (PM) Company ID#: Primary phase connected to: Tested Secondary Voltage Material ID#: Foreman to redline the following information V02 317602-165754Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage V01 317612-165745 250kVA Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage V01 317612-165745 250kVA Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage V01 317612-165745 250kVA 750kVA 6259300 PRIMARY CABLE & CONDUIT DIAGRAM NOT TO SCALE CIVIL CREW NOTE: ALL 4" - 90° BENDS MIN 60" RADIUS SCH-80 PVC ALL 4" - 45° BENDS SCH-80 PVC - ALL CONDUITS SHALL BE CAPPED AT EACH END UNTIL CABLE IS INSTALLED PRIMARY CABLE & CONDUIT TABLE (FOREMAN TO COMPLETE) LOCATION CONDUIT PRIMARY CABLE QTY OF LUBE (gal.)REMARKS FROM TO SIZE (in)QTY DESIGN LENGTH (ft) ACTUAL LENGTH (ft) TYPE BENDS PULL (lbs) PULL REV (lbs) SIZE DESIGN LENGTH (ft) ACTUAL LENGTH (ft) CABLE NUMBERS MANUFACTURING INFORMATION For Feeder Cable Only Check applicable box DB120 HDPE SCH 80 90 45 22 11 A B C MANUFACTURER COMPOUND YEAR TAPE CN #4/0 NEU DESIGN AS BUILT J01 V02 4 1 15 197 180 1/0 AL JKT 120 EJF472 EJF473 EJF474 0.1 TOTAL 4"15'TOTAL 3Ø 120'TOTAL LUBE 0.1 ABANDONED / REMOVE / REPLACED CABLE SCHEDULE CABLE NO. SAP EQUIP LOCATIONS CABLE (LF) EST EXISTING CABLE MFG. NAME EXISTING CABLE MFG. DATE ABANDONED CABLE LEFT IN PLACE ABANDON CIRCUITRYFROMTO 4557 10603532 J02 S02 192 NO NO 4558 10603549 J02 S02 192 NO NO 4559 10603565 J02 S02 192 NO NO 4563 10603629 S02 S01 68 NO NO 4564 10603645 S02 S01 68 NO NO 4565 10603657 S02 S01 68 NO NO 4566 10603668 S01 V01 74 NO NO 4567 10603680 S01 V01 74 NO NO 4568 10603700 S01 V01 74 NO NO 4560 10603589 J01 S01 231 NO NO 4561 10603602 J01 S01 231 NO NO 4562 10603616 J01 S01 231 NO NO TOTAL CIRCUIT FEET 565' 2" Excavation - 20 cubic yards 8'-0" or 10'-0" 7'-0" 8'-0"8" 4'-2" SIDE VIEW 4'-6"Crushed 6" Rock 11' 11' TOP VIEW 3'-6" 7'-0" 6045.5000Not to scale VAULT & EXCAVATION DETAIL L. NEELY 253-569-2523 1/23/24 MFP24001935 RESTORATION PER CITY OF RENTON STANDARDS