Loading...
HomeMy WebLinkAboutMFP17004738DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP17004738 IVR Number: 17004738 Permit Informa!on Permit Name:Comcast Cable Franchise Permit Address/Loca!on:09/25/2017Applica!on Date:8011100077Parcel Number:3303 NE 7TH ST Permit Type :10/13/2017Issue Date:Franchise Permit Work Class:10/13/2018Expira!on Date :Minor U#lity Job Number:258935Franchise Type :Cable Descrip!on:INSTALL 2" CONDUIT IN JOINT TRENCH. Contacts Name Address PhoneTypeBilling Comcast Cable Communica#on Management & Comcast Cable Holding B: (215) 665-1700Applicant Tom Donnelly Comcast Business Communica#ons LLC 1701 J9 Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Brian Hoback Comcast B: (253) 864-4663Contact Akisha Brown Prince Telecom Inc 551A Mews Dr New Castle, DE 19720 B: (302) 482-8893 C: (302) 482-8892 Contractor Business License Number: BL.029850Electrical Contractor : PRINCTL834BF Construc!on Contractor : PRINCTL862PS CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 Specialized Billing X General Condi!ons & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT -----~ItentOil ® Planning Division I 1055 South Grady Way, 61h Floor I Renton, WA 98057 I 425-430-7200 Email: franchisepermits@rentonwa .gov Website: rentonwa .gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov . Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Comcast of WA IV Inc Franchise Job Number: 258935 Phone: 253-864-4663 --------------~ Contact Name: Brian Hoback Email: brian_hoback@comcast.com --------------~ Job Site Address: 3303 NE 7th ST Project Name: Description of Work: Installation of 2" conduit in joint trench for CATV service line. Please check all that apply: I!!!!! New Construction D Repair/Relocate D Underground D Open Trench D Bore # of feet: _8_0_' ______ _ Contractor Name: Prince Telecom LLC State Contractors License#: EC PRINCTL834BF D Overhead D Sidewalk Phone: 253-891-2899 City of Renton Business License#: 29850 D Street --------- "I certify that I am the owner or applicant's authorized agent and do hereby agree to abide to the terms and conditions set forth under this permi and shall co ly with the City of Renton's Trench Restoration and Street Overlay Requirements ." Date 09/23/2017 Signature ------------------------~ INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Site Construction Inspector Development Engineering Manager Date Date Date D Approved as submitted O Pre-Construction Meeting required O Approved with comments or redlines O Camera inspection of utilities required Page 1 I Publ ished: 3/30/2017 Bernasconi @ 3303 NE 7th MFP17004738 Holly Powers 10/10/2017 Justin Johnson 10-12-2017 Print Form I I Reset Form ---oc~filiU:@IDl ® CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME : 3303 NE 7th ST Comcast Job 258935 PERMIT# CONSTRUCTION COMPANY: Prince Telecom LLC PHONE#: 253-891-2899 CONTACT NAME : Ryan Wilkerson PHONE#: 253-261-1882 ADDRESS: 2205 West Valley Hwy E Sumner, WA 98390 CELL#: E-MAIL ADDRESS: ryan.wilkerson@princetelecom.com FAX#: PROJECT LOCATION)303 NE 7th ST Comcast Job 258935 N/E/S/W OF: WORK TIME : 8:30AM -4:30PM APPROVED BY : WORK DATE : 10/02/2017 APPROVAL DATE: Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington . • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices . • Notify emergency services (253 -852-2121) twenty-four (24) hours before any street or lane closures . • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47 .36.200 through 47 .36.220, 9A .36.050 Reckless Endangerment, and other applicable State and City codes . • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney's fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder's agents and employees . • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid , including the City's reasonable attorney's fees and litigation costs incurred resulting from such claim. . In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same . . Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements . PRINT NAME: me DATE:{Y1~(ft OFFICE COPY T· CONT RACTOR DEV . SERVICE , INSPECTION P. MILLER DEV . SERVICE, PLAN REVIEW B. BANNWARTH SIGNATURE: PO LI CE CHA RLE S KARLEWICZ FIR E FI RE M AR SHALL FS #13 MFP17004738 Justin Johnson 10-12-2017 NOTES : • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT . The plan must be submitted to the City's PW/Transportation Div ision for review and/or approval at least three working days prior to work. Approved Temporary Traffic Control Plan must be at the work site during work hours. Contractor or entity must call Renton School District (425 -204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded . • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits ofTemporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone w ith at least two signs per block 72 hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on . If deemed abandoned, City crews will remove and store them at the City's maintenance shop (3555 NE 2"d Street). SKETCH NORTH -- LRC : l l !iA I %V. Drop: 2.!l"A> 56 F Ucker: 3.5% '• ... '\_ ______ _ 1 --·--- :~ ... : : . _';~--:(·~ • .l SITE PLAN I I ! ~~'A i'.' I""·· .. , ...• , .. '. ', -~. :'.-. 1· '· I ~ -~-_J @ 3 18343-166880 25kVA 120!240v ---oH TRESPASS MFP17004738 9/22/2017 3303 NE 7th St -Google Maps 3303 NE 7th St Imagery ©2017 Google , Map data ©2017 Google United States 100 ft https ://www.google .com/maps/place/3303+NE+ 7th+St, +Renton , +WA+98056/@4 7.4944566 ,-122.17 4 7864 ,21Om/data=!3m1!1e3!4m5!3m4!1 s0x54906 ... 1/1 MFP17004738 SIGN SPACING • X (1) MINIMUM SHOULDER TAPER LENGTH • Ul (feet) CHANNELIZATION DEVICE BUFFER DATA RURAL ROADS & URBAN ARTERlALS 35 /40 MPH JSO'• SPACING fleet\ RURAL ROADS, URBAN ARTERIALS, SHOULDER Posted Speed (mph) MPH l TAPER I TANGENT LONGITUDINAL BUFFER SPACE • B 25 130 MPH 200'.t (2) Vv'IOTH J5140 l JO I 60 RESIOENllAL & BUSINESS DISTRICTS ,, I JO I JS I ., I 50 I ss I 60 l 6S l I 2s I JO I JS I •O I 45 I 50 I 5S I 60 I 65 I 70 ( ... t) 40 70 25/JO I 20 I 40 SPEED (MPH) URBAN STREETS 25 MPH OR LESS 100'i (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE 8' 40 I 40 I 60 I 90 -I -I -I -I I LENGTH (feel) I 155 I 200 I 250 I J05 I I I I I I INTERSECTIONS ANO DRIVEWAYS. 1Cl' 40 I 60 I 90 I 90 -I I -I -I I (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT BUFFER VEHICLE ROLL AHEAD DISTANCE • R ROADWAY CONDITIONS. USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8' TRANSPORTABLE ATIENUATOR 30 FEET MIN MINIMUM HOST VEHICLE 1.M:IGHT 15,000 LBS. THE MAXIMUM TO '¥\EIGHT SHALL BE IN ACCORDANCE WTH THE MANUFACTURERS 100 FEET MAX. RECOMMENDATION. PROTECTIVE VEHICLE NO SPECIFIED MAY BE A 'AQRK VEHICLE STRATEGICALLY LOCATED TO SHIELD otSTANCE THE \'VQRK AREA. REQUIRED 1~ - - ------- -----!l --- ------1 & 7 -7 D D D D D D D D 0 T ~ WORK AREA~ Q Kl Kl 0 033 () I I 0 () .... ,, I x I x I UJ B I ~ I SO' I I I I l 411" 48" ROAO WORK SHOULDER AHEAO WORK 411" 48" W20-1 W21-5 LEGEND Kl TEMPORARY SIGN LOCATION SHOULDER CLOSURE -LOW SPEED D NOTES: CHANNELIZING DEVICES (40 MPH OR LESS) CJ33 PROTECTIVE VEHICLE 1. DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL BE 20'(FT). NOT TO SCALE 2. All SIGNS ARE BLACK ON ORANGE. FILE NAME S:\DHkln R P& S\4-Sbndards\2-Ptan Stlfft Ubnlrv\01-Pubhh.c:I PSLVTC Work Zont Ttlf'ftc Control\ W C-5 ShOulder Clo.Ure • Low S .... H Of l.Hs)\TC-5.dgn ~ TIME 1:20:14 PM •::-i1 ITAill: FED.AID PROJ.ND. ..... ~-~ DATE 911812U14 jwAS~ w TCS PLOTTED BY FtetcCo ,____ DESIGNED BY ---ENTERED BY Washington State -CHECKED BY ~ ... LQC.\1ElllMO. Department of Transportation ~ PROJ. ENGR. ~ ----....--TRAFFIC CONTROL PLAN ~ REGIONAL ADM. REVISION DATE BY ..... " ..... _ ..... 11 ..... -0• MFP17004738